Technical specifications:

CARDIAC MARKER INFECTIOUS DISEASE THYROID INFLAMMATION


cTnl* HBsAg
TT3 PCT
Myo* Anti-HBs
FT3 CRP
CK-MB* HBeAg
TT4 SAA
NT-proBNP* Anti-HBe
FT4 IL-6
h-FABP Anti-HBc
TSH
MPO Anti-HCV
TG-Ab
D-Dimer Anti-TP
TPO-Ab
HBsAg HIV

iTube 3000
TUMOR MARKER ANEMIA BONE METABOLISM
AFP* HE4 FA 25-OH VD
CEA* Fer* VB12 PTH
DIABETES FERTILITY/HORMONE

Chemiluminescence Immunoassay Analyzer


NSE* tpSA

CA125* fPSA INS LH*

CA15-3* CYFRA21-1 C-P FSH

CA19-9* SCC Anti-IA2 FE3


INS-Ab E2
ProGRP CA242
ICA HCG
PGI* CA50
GAD-Ab PROGESTERONE*
PGII CA72-4
TESTOSTERONE* PAPP-A
β2 MG S100
GH
PACP PRL

HCG β-HCG
CT

AUTOIMMUNITY
Anti-Histones Anti-Jo-1

Anti-Sm Anti-PM-Scl

Anti-β2-GP1 Anti-Centromeres
Anti-Cardiolipin Anti-LKM
Anti-dsDNA Anti-Scl-70
Anti-Nucleosomes Anti-CCP

Anti-GBM Anti-nRNP/Sm Convincing performance


Anti-Keratin Anti-SS-A
Anti-RF Anti-SS-B
Anti-PF Anti-LC-1 Time to first result within 18 minutes
Anti-PR3 Anti-Sperm
Anti-MPO Anti-Ovary
Anti-M2-3E Anti-SM Acridinium Ester Chemiluminescence Technology
Anti-HCG Anti-ZP
Anti-Trophoblast Anti-FM
Highest accuracy and precision
Lepu Medical Technology (Beijing) Co.,Ltd.
Add: No. 37 Chaoqian Road,Changping District, Beijing, 102200,P.R. China
Tel:+86-13538971911
Email: ines.huang@lepu-medical.com
Website: en.lepumedical.com

The content of this brochure is for reference only. For further information on technical details, specifications and applications
please contact your local Lepu representative. The content of this brochure can be updated without prior notice. Lepu reserves
the right of final interpretation.
iTube 3000 3.Consumables 8.Software module

Fully Automated CLIA Workstation • Load 60 Reaction cuvettes & 60 Disposable tips at one time • Multi language interface can be arbitrarily switched,simple,intuitive
• No pausing loading during test and convenient.
• Real man-machine dialogue,automatic preparation of reagent
consumables,locate the sample results you need to find at any time,reasonable
interface distribution
Properties and characteristics: • Intelligent Alarm
• iTube 3000 docked with the supporting information management
• Complete independent intellectual property rights software of the laboratory to realize effective intelligent information management.
• High speed and simplify operation.Advanced Acridinium Ester Flash method.
• Random.Batch and STAT test modes,24 hours standby time. Technical specifications:
• Test Throughput up to 200 tests per hour;
• Time to first result:18 minutes. Product Specifications
4. Washing module Model iTube 3000
• Disposable pipetting tips elimate any risk of cross contamination.Permanent
reagent probe provides accurate,reliable and safe liquid transfer. Design Cabinet
• Washing 4 times with shaking function
• Barcode recognition sample function connected to Hospital LIS/HIS system to • 4 channels with frequency and time adjustment Transfer arm 1
realize data sharing. 4D Transfer arm 1
• High sensitivity PMT detection system,It can achieve fast detection with stable Throughputs 200 Test / hour
results and high sensitivity. Time to first result 18 minutes,depends on assay
• Rotating shaking washing mode effectively avoids the magnetic particles clotting Assay technology Acridinium Ester Chemiluminescence
during washing.
Sample transfer module
Sample pipetting channel 1
Functional module: Sample type Serum/Whole blood
5. Reaction module Sample position 5*24=120 samples
1.Sample transfer module Sample pipetting tips 200μl Disposable Tips
• Principle of metal and air bath heading Pipette tips precision
• Sample position:5 tube racks (with tube rack identification code), CV≤1%@50μl
• 155 reaction positions
5*24=120 sample positions,accepts samples randomly. Sample pipette range 10-200μl,Increment:1μl
• Stable incubation temperature kept at : 37℃±0.5℃
• Samples loading mode:orbital loading mode with STAT acce
• Tube specification:standard cup,cuvettes(φ12*37mm、φ14*25mm),
Reagent module
Primary tube (φ12-13mm*65-100mm).
Reagent probe channel iTube 3000
• 1 Sample pipetting channel
Reagent position Cabinet
• Sample pipetting range:10μl~200μl,Increment:1μl
• Sample barcode identification. Reagent probe pipette precision CV≤1%@100μl
• Disposable tips for Sample pipetting,with liquid level monitoring,clot 6. Reading module Luminescence curve Reagent pipette range 20μl-350μl,Increment:1μl
monitoring and tube volume monitoring.
• Read time:1S,fast and stable reading results
• Sample dilution function.Support STAT priority. Reaction module
• It can be used for Chemiluminescence Flash Technology with
Acridinium Ester as markers Sample position 155(60+50+45)
Reaction cuvettes 60
2.Reagent tray module
Time Reaction bath Air & Metal bath
• Reagent pipetting channel Reaction temperature 37℃ ± 0.5℃
• Non-contact reagent mixing mode to reduce cross-contamination
• 4*30=120 reagent positions,no-pause loading and replace reagent kit randomly
• Reagent refrigerated 2-12℃. Independent power supply,the reagent tank continues 7. Others Reaction module
keeping refrigerated after the instrument turns off. Reading time 155(60+50+45)
• Reagent pipetting range:20μl~350μl,Increment:1μl • 1 4D transfer arm Software LIS/HIS system through
• Reagent barcode identification.(support 1D & QR code). • 1 transfer arm a standardized laboratory
• The functions for permanent probe aspirates and dispenses the reagent,capacitive data exchange format.
liquid level detection,three-dimensional anti-collision,instantaneous power-off protection,
inner & outer wall washing and etc.