You are on page 1of 2

BROAD ASSAY

MENU
AE-180
Tumor Markers
Infectious
Diseases
Thyroid Fertility Bone Marker TECHNICAL SPECIFICATION
CEA HBsAg (quantitative) T3 T BAP
Equipment Type Cabinet
AFP Anti-HBs T4 P PTH

Automatic Chemiluminescence
(quantitative)
PSA HBeAg (quantitative) FT3 E2 N-BGP Principle Acridinium ester direct chemiluminescence immunoassay

Immunoassay Analyzer
fPSA Anti-HBe (quantitative) FT4 LH 25-OH VD Up to 120T/h
TAT<35min
PAP Anti-HBc (quantitative) TSH PRL CT Main Features Systematic CV< 5%
cPSA Anti-HCV TG FSH Full automation
Auto-immunity MTBF>220 days
CA50 Anti-TP Anti-TG uE3
CA242 HIV Ag/Ab Anti-TPO HCG Anti-PR3 144 samples on-board
Sample Unit Random, batch and STAT available with continuous loading
CA125 Anti-HIV Anti-TSHR ß-HCG Anti-CCP Sample barcode scanning
CA19-9 Anti-HEV IgG PAPP-A Anti-MPO
Hepatic Fibrosis 20 reagent positions on-board
CA15-3 Anti-HEV IgM AMH* Anti-dsDNA IgG Temp controlled between 2-8℃
Reagent Unit Automatic magnetic beads mixing
CA72-4 SARS-CoV-2 IgM* PIII NP Reagent loading online
Glycometabolism Anemia
CYFRA21-1 SARS-CoV-2 IgG* CIV
Double needles for reagent and sample separately
NSE HA INS Fer
Cardiac Sample/Reagent Needle
SCC LN C-P VB12* Avoid carryover
Liquid-level detection, clot detection and collision protection
HE4 MYO CG FOL*
Inflammation Integrated Kit with reagent and calibration
PGI CK-MB
Hypertension -
PGII cTnl PCT Reagent Features 2 weeks working curve stability
Open stability: 60 days
ProGRP Hs cTnI ALD CRP
S100 NT-proBNP Renin IL-6
Walkaway Up to 450 tests or 4.5 hours
ß2-MG D-dimer AI
HER-2/neu AII PC System Microsoft Windows 10

TNF- α LIS Connection Mode Bilateral LIS

* In Development Size & Weight Cabinet type: 180(L)*80(W)*160(H)cm, 360kg

Power Supply 900VA, AC220V, 50/60Hz

Humidity <70%, Air Pressure 86KPa-106KPa


Work Environment Altitude 400~4000m, Temperature 10-30°C

Legal manufacturer Suzhou Hokapi Biomedical Engineering Co., Ltd.

HIGH QUALITY ASSAY performance Catalog HOKAPI™ AE-180 Automatic Chemiluminescence Immunoassay Analyzer

bioMérieux R&D QUALITY experience enhanced on the menu Cat. No. AE18-MA00-0031

Flagship tumor marker panel Please send e-mails to market@hokapi.net for further information and product availability.

Address: Block 4, No.8, Jinfeng Road, Suzhou, China


TECHNOLOGY & INSTRUMENT
ADVANTAGES CONFIGURATION SAMPLE UNIT
HOKAPI™ AE 180 System adopts the "FLASH"
HOKAPI AE-180 ™ 144 samples on-board
Direct chemiluminesence technology (CLIA) Random, batch and STAT available with continuous loading
with paramagnetic microparticle solid phase CABINET VERSION Sample barcode scanning
and offering broad test menu,
including numerous specialty tests.
CUVETTE SAMPLE/REAGENT NEEDLE
STORAGE UNIT Double needles for reagent and sample
75 cuvettes on-board separately
for 450 tests Needle with t
Cuvettes loading external cleaning , avoiding carryover
online
ARGENE available
CONNECT QUALITY
ARGENE / QUALITÉ
CONNECT QUALITY / QUALITÉ
Liquid-level detection, clot detection
DIAGNOSTICS DIAGNOSTICS
and collision protection

PRINCIPLE

Biotin labelled
Ag/Ab(R1)

Up to 120T/hARGENE CONNECT Fully


METHODS/SOLUTIONS
LAUNCH DIAGNOSTICS
LAUNCH METHODS/SOLUTIONS Automatic
PRODUCTION
QUALITY / QUALITÉ PRODUCTION Reliable
ARGENEARGENE
DIAGNOSTICS
DIAGNOSTICS CONNECT
CONNECT Robust
QUALITY
QUALITY / QUALITÉ
/ QUALITÉ
Incubate
at 37°C
Wash off
unreacted reagent
MICROBIOLOGY MICROBIOLOGY
LAB AUTOMATION AUTOMATION
LAB performance 10 -6 MTBF > 220 Days
Serum
SA coated
Magbeads(M)
AE labelled
Ag/Ab(R2)
carry-over

2
24
RLU
20
16
12
8

PRODU
4
Easy to use technology
CLIAARGENE based
Substrate PRODUCTION METHODS/SOLUTIONS
0 LAUNCH METHODS/SOLUTIONS LAUNCHLAUNCH
DIAGNOSTICS CONNECT
METHODS/SOLUTIONS PRODUCTION
QUALITY / QUALITÉ
AUTOM
MICROBIOLOGY LAB
4.5h walk-away AUTOMATION AUTOMATION
0 10 20 30
Immuno MICROBIOLOGY LAB MICROBIOLOGY LAB
Flash type Chemiluminescence Analytes concentration
Complex

CLIA ADVANTAGES INCUBATION UNIT READING ROOM


Temp controlled at 37±0.5°C Excellent PMT
INCREASED EXCELLENT SUPERIOR Mix during incubation Spectral response range: 300-650nm
SENSITIVITY REPRODUCIBILITY IA PERFORMANCE Automatic aspirating waste liquid after test,
PRODUCTION
LAUNCH METHODS/SOLUTIONS
Magnetic Beads / Biotin-Avidin System* Acridinium Ester Substrate decreasing biological contamination
MICROBIOLOGY LAB AUTOMATION
Homogeneous Immunoassay
REAGENT UNIT
• Easier Ag/Ab labelling • Very low background
• Greatly increased solid phase /
Liquid assay
• Enlarge the binding capacity
(SA : biotin = 1:4)
• Easier Ag/Ab labelling/
Good stability 20 reagent
HYBIOME positions on-board
READING KIT
All-in-one design, including
HYBIOME
• Small molecule of AE,
• Biotin-avidin high Temp controlled between 2-8°C
affinity constant not interfere Ag/Ab activity reagent kit and calibration
• Direct chemiluminescence Automatic magnetic beads mixing
(106 higher than Ag-Ab) Reagent open stability up to 60 days
Reagent loading online

HYBIOME

You might also like