+DC 15A
-DC 15A
+DC 15A
SURGE 4mm² PV
4mm ² x 4 Solar LIGHTNING WIRE
ARRESTOR
cable 1000VDC
Cable run in plastic
conduit outside and
1 2 3 4 12 13
buried unground to
RJ46 Port Garage Flexible
RS485 METER conduit used for 10mm² Earth
Meter COM underground
ACR10R-D16TE
5 6 7 8 9 10 21 22 23
MAXIMUM
White Black CAT 6a Ethernet Cable 2 cores used for CT coil Run
1000M in separate conduits for the protection and EMF
screening a distance of 7 M
PV2 ISOLATOR
DISTANCE
FOR CABLE
BACKUP LOADS CONSUMER UINT EXISTING CONSUMER UINT
BETWEEN
1.mm² Brown
+DC
-DC
AC By Pass Change
PV ISOLATOR
over Switch 100A
Break Before Make
RCD RCD
Used to Switch
+DC
-DC
MANUAL ISOLATOR
MPPT 1
DRM 5
RJ45 6
AC OUTPUT ISOLATOR
SOLIS HYBRID INVERTER
RHI-(3-6)K-48ES-5G AC OUTPUT 10mm SWA
3CORE
AC OUT ISOLATOR
G99 TYPE TEST SOLIS/02107/V1 L OUT
CB 32A BACKUP 3KW
N OUT
CT Direction
toward the
AC INPUT ISOLATOR Grid
10mm SWA 25mm² Double
AC IN ISOLATOR insulated tails
AC IN 3CORE
L IN L
BATTERY BATTERY
N IN N GRID
BMS 16mm² Earth
CAN - + E E
E/STUD
TN-C-S PMES
EARTH
AC INPUT
Note Battery leads (+) & (-)
From Isolator from Inverter (GRID) 6KW
and to the batteries to be INVERTER
the same length
LOCATION
HOUSE
CAN LNK
- +
LNK
CAN LNK
- +
48VDC BATTERY LNK
CAN LNK
- +
LNK