XP-Builder V3.

60 Improvement & Addition

1. Improvement & Addition

1) Added audit log viewer


- Provides a function to display log (record) values of XP-Runtime work log file.
- It can be executed by clicking [Main Menu]-[Tools]-[Audit Log Viewer] of XP-Builder and the
supported format is .CSVE (encrypted CSV file).

[Operation Log Setting]

1) Check Backup File(CSV) encoding


[Audit Log Viewer]

1) Specify the folder where the audit log file (.CSVE) is located.
2) When a folder is selected, a list of audit log files (.CSVE) in the folder is displayed.
3) Click the [Search] button to display the record values of the selected file in the list control.

2) [XP-Builder] Added XP-Builder execution function for each language


- Provides XP-Builder execution function for each language through the menu (No need to
reinstall XP-Builder).
3) Improved history alarm view object
- Added sort function for accumulated time of unrecovered alarm.

4) [XP-Builder] Improved graphic user library thumbnail image display ratio


- Thumbnail images are displayed in the original image horizontal and vertical size ratio.
5) Special switch - improved FTP client
- Added download path designation function in FTP client object.

6) Improved device synchronization


- Added bit device data size to device sync settings
- Added a function to enable two-way synchronization when synchronizing devices.

7) [XP-Builder] Addition of batch change function such as extended file recipe size and format
(AutoFill function)

8) [XP-Runtime] When the custom encryption keypad is displayed, the security level is displayed in
the screen title area

9) [XP-Manager] Improved XP-Manager Autoscan


2. Error Correction
1) [XP-Builder] Fixed the problem that “Import XG5000 symbol” in XGB-XBMH2 and XGB-XBMH
models could not be done.
2) [XP-Builder] Fixed a phenomenon in which some characters were increased in a numeric way
when copying object strings continuously.
3) [XP-Builder] Fix abnormal termination when double-clicking on an empty area in “Screen List
Small View”.
4) [XP-Builder] Fix abnormal termination when the number of multi-line character strings exceeds
32 in the character string table.
5) [XP-Builder] Fixed the phenomenon that the tab style was vertically aligned when other tool
windows were combined with the script tool window.
6) [XP-Builder] Fix abnormal termination when opening device synchronization setting window in
Windows English OS.
7) [XP-Runtime] Fixed the phenomenon that the graph is drawn before the set time when the trend
graph acquisition cycle exceeds a certain period of time.
8) [XP-Runtime] Fixed Runtime crash when using LS Ethernet/IP communication.
9) [wXP] Fix screen capture image storage location error
10) [wXP] Fixed the problem that a message stating that wXP is not installed when downloading
after checking project execution in local wXP

3. Communication Driver

1) New communication driver


(1) eMOTIONTek: MCST-80 (Ethernet)
(2) eMOTIONTek: MCST-80 (Serial)

2) Communication driver improvement

(1) Program monitor improvement


- LS: GM (Ethernet)
- LS: MASTER-K (200,300,1000)S (Ethernet)
- LS: XGI / XGR (Ethernet)
- LS: XGK (Ethernet)
- LS: XEC (Ethernet)
- LS: XGB (Ethernet)
- LS: XGI (CPU Ethernet)
- LS: XGK (CPU Ethernet)

(2) Support XGI-CPUZ (GEN3)


- LS: XGI / XGR (CPU Ethernet)
- LS: XGI / XGR (Ethernet)
- LS: XGI / XGR (Ethernet/IP)
- LS: XGI / XGR (LINK)
(3) Optimization of read/write communication frame
- OMRON: CS/CJ Series HOST Link

(4) Troubleshooting when using “Use monitor table”


- MITSUBISHI: MELSEC-QnA,Q(LINK)

(5) Troubleshooting when bit inversion switch is pressed


- Siemens: SIMATIC S7 1200/1500 Ethernet

(6) Added error detection “CRC” mode


- Rockwell: ControlLogix/CompactLogix Series (DF1)

(7) Troubleshooting intermittent anomalies in logging data


- Siemens: SIMATIC S7 300/400 Ethernet
- Siemens: SIMATIC S7 1200/1500 Ethernet

(8) Serial communication added a function to manually control whether communication is


performed by station number
- LS: XGI / XGR (LINK)
- LS: XEC (LINK)
- LS: XMC (LINK)
- LS: XGK (LINK)
- LS: XGB (LINK)
- MODBUS ASCII Master
- MODBUS RTU Master
- MODBUS STANDARD ASCII Master
- MODBUS STANDARD RTU Master
- OMRON: CS/CJ Series HOST Link

Manually control whether or not communication of individual station number of serial communication
is performed. When the value of HS217.1 is (0), it is controlled automatically, when it is (1), it is
controlled manually. This function works only when the “Communication error handling” option is
“Stop” or “Disconnect”
※ For details, refer to “2.6 Serial communication, common functions” communication manual.