You are on page 1of 6

GE .

Power Conversion

GE FILTER RESISTORS OP1147226


Power Conversion 2021-12-22 Release 1
PART A: DATASHEET
GENERAL DATA REVISION COMMENT
1 resistor set
Quantity (items) 1
Each set composed of 1x3 single phase resistors
Cooling Air natural 1
Installation Outdoor (without solar protection) 1
Location Gijon, Spain 1
Application MMC STATCOM for EAF 1
SCOPE OF SUPPLY
Quantity of resistors (1x3)=3 single phase resistors (for 1 rank) 1
Design Included 1
Manufacturing Included 1
Factory acceptance tests Included 1
Documentation in English Included 1
Packing Included 1
Transportation Included 1
Technical support during installation & start up Included 1
Spare parts Included 1
CUSTOMER SPECIFICATIONS & SPECIFIC STANDARDS
Applicable code and standard IEC as per part B 1
1
1
ENVIRONMENT
Altitude <1000m above sea level 1
Operating temperature range min -10°C to max +35°C 1
Relative humidity 10% to 90%, no condensation 1
Storage temperature min -10°C to max +35°C 1
Maximum wind velocity 44 m/s (160km/h) 1
Seismicity
- Seismic zone
Low risk,
- Design horizontal ground acceleration 1
acceleration factor <0.16g
- Importance factor
- Soil factor
Mm x kV
Pollution class Very Heavy-polluted - class V insulation 31 phase to 1
phase, 53.7 phase to earth for outdoor equipments
Atmospheric corrosivity category C4 according EN12944 - 10 years 1
NETWORK DATA
Network rated voltage (kV) 33 1
Steady state rated voltage fluctuation -5/+5% 1
Network rated frequency (Hz) 50 1
Steady state rated frequency fluctuation +/-0.5% 1
Maximum short circuit power at rated voltage
1000 MVA 1
and rated frequency
Minimum short circuit powerat rated voltage and
500 MVA 1
rated frequency
Neutral connection to earth TBD 1
CABLE CONNECTION
Terminals for reactor
Number of line terminal 1
& resistor connection
Cable number on each terminal later 1
Cable type later 1
Cable section later 1 mm2
Cable inlet later 1
Cable termination length N/A 1 mm
Degree of protection for the terminal box (If cubicle enclosure) 1
Degree of protection for auxiliary box (If cubicle enclosure) 1

22/12/2021
Filter resistors Page 1/6
GE .
Power Conversion

TYPE OF MOUNTING
Bushings
- type To be determined by supplier
- creepage distance (mm) To be determined by supplier
Internal Insulators (per resistance)
- number To be determined by supplier
- type To be determined by supplier 1
- insulation (kV) To be determined by supplier
- creepage (mm) To be determined by supplier
DIMENSIONS & WEIGHT
Overall dimensions approx.
From supplier 1
L x W x H in mm (preliminary)
Cross section (preliminary) From supplier 1
Weight (preliminary) From supplier 1
MECHANICAL & CONSTRUCTION
Degree of protection IP23 1
Sound Pressure Level 75 dB(A) at 1m distance at full load 1
Hot dip galvanized
Enclosure finishing Adapted to the site conditions: pollution, UV (RTV 1
Silicone coating), salty air

22/12/2021
Filter resistors Page 2/6
GE .
Power Conversion

ALL FILTERS - ELECTRICAL CHARACTERISTICS


Tolerance on resistance rated value +/- 5% 1
Option 1: Less than 20% OPTION 1: Less than 20%
Variation between cold and hot value 1
Option 2: Supplier’s choice OPTION 2: Supplier’s choice
Rated voltage 33 1
Voltage variations -5/+5% 1
Rated frequency 50 1
Frequency variations +/-0.5% 1

Voltage across resistor terminals (case in short


33 / √3 x 1.1 = 21 1
circuit and during filter energization) (kV)

Insulation class 36 kV 1
Standard rated power frequency withstands
70 kV 1
voltage
BIL 170 kV 1
FILTER 1 - ELECTRICAL CHARACTERISTICS
Rank 1.96 1
Rated resistance (Ohms) hot value 150.23 1
Rated Power for total resistor(kW) 83 1
Rated total RMS current for total (A) 23.53 1

22/12/2021
Filter resistors Page 3/6
GE .
Power Conversion

ACCESSORIES
Lifting lugs X 1
Cable glands X 1
Tag number identification plate (stainless steel) 1 1
SPARE PARTS
Spare parts list N/A 1
General Arrangement drawing later 1
Mechanical & electrical interfaces later 1
Material list later 1
Nameplate, rating and label drawing later 1
Painting procedure later 1
Factory test procedure with FAT Notification 1
Factory test report 1 week after FAT 1
Quality inspection and test plan later 1
Installation, maintenance & operation instruction
later 1
manual
Preliminary packing list later 1
Packing list later 1
Certificates of origin and conformity FAT 1
SPECIFIC
FCA
Incoterm 1
Option for FOB European seaport
- 1
- 1
- 1
- 1
- 1

22/12/2021
Filter resistors Page 4/6
GE .
Power Conversion

DATASHEET TO BE FILLED BY THE SUPPLIER, PER RESISTOR, FOR OPTION 1 AND FOR OPTION 2
Rated Resistance (Ohms)(cold / hot
1
temperature)
Tolerance at 20°C 1
Rated Power (kW) 1
Length (mm) 1
Depth (mm) 1
Height (mm) 1
Total weight (kg) 1
Type of active part 1
Temperature max reached by the active parts 1
Temperature coefficient 1
Resistance at maximum temperature 1
Rated Current Ir (A RMS) 1
Stray inductance 1
Insulation level (kV) 1
Noise level (dBA) 1
Enclosure degree of protection 1
Enclosing finishing 1
Bushings: 1
Type - 1
Creepage distance 1
Base Insulators (per resistance) : - 1
Number 1
Type 1
Insulation (kV) 1
Creepage (mm) 1

22/12/2021
Filter resistors Page 5/6
GE .
Power Conversion

PART B: GENERAL REQUIREMENT


STANDARDS
IEC 60071 Insulation co-ordination 1
Tests on indoor and outdoor post insulators of ceramic
IEC 60168 material or glass for systems with nominal voltages 1
greater than 1000V

Characteristics of indoor and outdoor post insulators


IEC 60273 1
for systems with nominal voltages greater than 1000V

Degrees of protection provided by enclosures (IP


IEC 60529 1
Code)
MANUFACTURING FEATURES
Electrical continuity: any metal part of the reactor, not
Cabling 1
intended to be energized, shall be earthed.
Each resistor shall be provided with a stainless steel
rating plate.
Rating Plate Indications of the rating plate, in particular the 1
reference standard, have to be transmitted in advance
to GE for approval.
FACTORY ACCEPTANCE TESTS
Notification to be provided at least 20 days before the
date of the test.
Test instruments have to be calibrated by an
1
independent body.
Calibration test reports shall be presented upon
Generals request during FAT.
Overall Dimensions & Weight(max)
Earth continuity
Painting / Coating conformity with applicable
specification
1
Marking & Cabling
Check that there are no loose parts
General compliance with relevant standards and
Visual Inspection specifications
Measurement of the rated resistance value
Dielectric test 1
Routine tests list Insulation test
1
DOCUMENTATION
Language of documents English 1
Forms of issued documents Word, Excel and Autocad. 1
To be provided in A4 size, with the original DOC and
Format of text documents 1
PDF files format.
To be provided in A3 size, with the original DWG and
Format of drawings 1
PDF files formats.
The manufacturer will have to provide the
entirety of the electronic documents provided in
1
format pdf and in their native format (for
translation)
PACKING AND TRANSPORTATION
To be defined 1
1

22/12/2021
Filter resistors Page 6/6

You might also like