ETABS 17.0.

1 License #

ETABS Concrete Frame Design


ACI 318-14 Column Section Design

Column Element Details (Envelope)

Level Element Unique Name Section ID Length (cm) LLRF Type


N1 C1 4 C central=80*80cm 295 0.474 Sway Special

Section Properties

b (cm) h (cm) dc (cm) Cover (Torsion) (cm)


80 80 5.6 1.73

Material Properties

E c (kgf/cm²) f' c (kgf/cm²) Lt.Wt Factor (Unitless) f y (kgf/cm²) f ys (kgf/cm²)


282495.13 350 1 5000 5000

Design Code Parameters

ΦT Φ CTied Φ CSpiral Φ Vns Φ Vs Φ Vjoint


0.9 0.65 0.75 0.85 0.6 0.85

Longitudinal Check for P u - M u2 - M u3 Interaction

Column End Rebar Area Rebar D/C Ratio


cm² %
Top 73.9 1.15 0.735
Bottom 73.9 1.15 0.838

Design Axial Force & Biaxial Moment for P u - M u2 - M u3 Interaction

Column End Design P u Design M u2 Design M u3 Station Loc Controlling Combo


kgf kgf-cm kgf-cm cm
kgf kgf-cm kgf-cm cm
Top -185775.15 -87859.95 -728981.68 235 0.8(CM+Pp)+Sismo dinamico
Bottom -182884.14 -1842696.58 -1645932.23 0 0.8(CM+Pp)+Sismo dinamico

Shear Reinforcement for Major Shear, V u2

Column End Rebar Av /s Design V u2 Station Loc Controlling Combo


cm²/cm kgf cm
Top 0.0706 7542.79 235 0.8(CM+Pp)+Sismo dinamico
Bottom 0.0706 7542.79 0 0.8(CM+Pp)+Sismo dinamico

Shear Reinforcement for Minor Shear, V u3

Column End Rebar Av /s Design V u3 Station Loc Controlling Combo


cm²/cm kgf cm
Top 0.1178 22188.07 235 0.8(CM+Pp)+Sismo dinamico
Bottom 0.1178 22188.07 0 0.8(CM+Pp)+Sismo dinamico

CARLOS FAVIAN MONTAÑO


Page 1 of 2 23/9/2019
FERNANDEZ.EDB
ETABS 17.0.1 License #

Joint Shear Check/Design

Joint Shear Shear Shear Joint Controlling


Ratio V u,Tot Vc Area Combo
kgf kgf cm²
Major(V u2) 0.077 24855.91 323827.21 6400 1.3(CM+Pp)+Sismo estatico
Minor(V u3) 0.077 74678.32 323827.21 6400 1.3(CM+Pp)+Sismo estatico

Beam/Column Capacity Ratios

6/5(B/C) Column/Beam SumBeamCap SumColCap Controlling


Ratio Ratio Moments Moments Combo
kgf-cm kgf-cm
Major 33 0.163 7.366 1404446.58 10344566.45 0.8(CM+Pp)+Sismo dinamico
Minor 22 0.483 2.482 4167569.57 10344566.45 0.8(CM+Pp)+Sismo dinamico

CARLOS FAVIAN MONTAÑO


Page 2 of 2 23/9/2019
FERNANDEZ.EDB