Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com 3
1.6 500 and 690 Volts range - aM
1
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57
1 Catalogue numbers summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58
Size 000 Time-current characteristics and technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59
1 Size 00 Time-current characteristics and technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60
1 Sizes 1 Time-current characteristics and technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61
Sizes 2 Time-current characteristics and technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62
1 Sizes 3 Time-current characteristics and technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63
1 1.7 NH Bases
1 NH Fuse bases and accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64-69
1 1.8 NH Gear
NH Fuse rails - vertical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70-73
1 NH Fuse switch disconnectors - vertical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74-79
NH Fuse switch disconnectors - horizontal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80-92
1
1.9 Index 93-94
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
4 Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com
NH Fuse links overview
Introduction and NH Fuse links’ selection criteria
1.1
1.1
Introduction 1
®
Eaton’s Bussmann series NH fuse links use the latest technology to provide class leading fuse link
performance and reliable indication. With a unique patented dual indicator design capable of operating a 1
microswitch for remote fuse indication, Eaton provides one of the most reliable solutions available.
1
The range is fully compliant with IEC 60269-1 and 2 standards, with VDE 0636-2 third party approval and
complies with the dimensional requirements of DIN 43620 for ease of use. 1
In order to help select the correct product for an application, Eaton provides the following application notes. 1
1
1
1
1
NH Fuse links’ selection criteria 1
Selecting the correct Full load current and should never be used Any fuse link line lying to
product
on a system where the the right of this point will 1
In accordance with IEC maximum short-circuit withstand the motor start
Before making a fuse link standards, Eaton’s Bussmann
series NH fuse links are
current exceeds this level.
Please refer to the time-
current (allowing for a +/-10%
tolerance on each fuse link
1
selection the following
tested to carry full load current curves in the curve). If the fuse link curve
information should be known
about the system or circuit to current. The current of a fuse catalogue. falls to the left of this point, 1
be protected. link should be equal or greater then the fuse link will not
than the operational current Time-current curves withstand the motor start 1
of the circuit and equal or current and will inadvertently
Type of application
(cable protection/
smaller than the continuous The time-current curve is
probably the most useful
operate when the motor is 1
current carrying capacity of started.
the conductor. piece of all fuse link data
motor protection) available. It allows you to In summary, the rule for 1
The standard gG (general determine how quickly time-current curves is that
For general applications or
cable protection, the standard
purpose) NH fuse link with a
conventional fusing current
the fuse link will operate any point on or to the right
of a fuse link curve would
1
gG (general purpose) NH fuse under fault conditions and
of 1.6 times current will give indicate the fuse link has
link should be considered.
assured cable protection
which fuse link will not
operated in the given time. 1
For Motor protection operate under non-fault
against the effects of overload currents. Any point to the left of the
applications, the aM (motor
protection) NH fuse link
overcurrents. curve would indicate the fuse 1
To use the curve simply plot link has not operated.
should be considered. Motor
Protection (aM) fuse links Non-fault overload the prospective Root Mean
Square (RMS) fault current
1
have partial range breaking currents (motor inrush along the X axis and draw a
ability and cannot clear low currents etc) line vertically upwards from 1
overload faults. They should this point. Where this point
only be applied to circuits To prevent nuisance operation intersects the fuse curve 1
also protected by a motor of the fuse link, the fuse line, plot a line across to the
protection relay or where link rating selected for the
only high short-circuit faults application should take
Y axis for the relevant rating. 1
The Y axis shows the nominal
could occur. into account any non-fault operating time for the fuse
Note: Please note that overload currents. Please in seconds. Hence, it shows
1
misapplication of a fuse link can refer to the time-current how quickly the fuse link will
be problematical, consult Eaton if curves in the catalogue. operate under different fault 1
there is any doubt over fuse link currents.
selection. Possible fault The graph can be used 1
System voltage conditions and to check if a fuse link can
maximum withstand an overload 1
Eaton’s Bussmann series condition that is not
NH fuse links are available in short-circuit current considered to be a fault such 1
three voltage ratings, 400 V, This information is essential as a direct-on-line (DOL)
500 V and 690 V. These are
maximum voltage ratings and
in order to select the fuse motor start. For example, if
a motor starts and the inrush
1
link that would provide the
should not be used where current is six times the full
the nominal system voltage
best possible protection
under all fault conditions. load current for 10 seconds, 1
could exceed the fuse link’s Eaton’s Bussmann series NH the exact point can be plotted
maximum rating. fuse links have a maximum onto the time-current curve. 1
breaking capacity of 120 kA
1
Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com 5
NH Fuse links overview
1.1 NH Fuse links’ selection criteria
1.1 Cut-off curves current along the X axis. If current the fuse link will allow the same procedure above.
this point only intersects the to pass before operating. Instead of plotting the point
The graph consists of an A-B A-B line then the prospective The peak asymmetrical of intersection with the
1 line running diagonally from fault current is too low to let-through current is the fuse link current-limiting line
bottom left to top right, see benefit from the current- absolute worst case peak over to the Y axis, it should
drawing below. This is known
1 as the non current-limiting
limiting effect of the fuse link. current the fuse link will allow
to pass through, taking into
only be plotted as far as
the A-B line. At this point,
However, if this point
line. Branching from this account the DC offset seen a line can be drawn back
1 A-B line you can see each
intersects the relevant fuse
under short-circuit conditions down to the X axis to show
link line, plot a line across
individual fuse link rating line and low power factor. a RMS symmetrical value of
to the Y axis. This point on
1 running diagonally left to
the Y axis shows the peak The RMS let-through current let-through current. This is
right. To read the graph, plot known as the “up, over and
asymmetrical let-through is read from the graph using
1 the RMS prospective fault down method”.
1
1 B
1 Fuse rating
1
1
1 Cut-off
current
(KA peak)
1
1
1
1
1
1 A
1
RMS prospective fault current
1
Shows peak let through current
1
Shows RMS let through current
1
1
1
1
1
1
1
1
1
1
1
1
6 Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com
NH Fuse links overview
NH Fuse links’ selection criteria
1.1
1.1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
I²t values • The total clearing I²t is total clearing I²t value of the DC applications 1
the yellow and green area fuse link downstream should
I²t values are measured at the under the first half cycle be less than the pre-arcing Eaton’s Bussmann series 1
time of testing the fuse link at from the start of the short- I²t value of the fuse link NH fuse links can be used
their rated breaking capacity on DC applications. In all
and voltage. I²t is effectively
circuit current flow to the
point where the fuse link
upstream. This ensures
the smaller fuse link, in the cases the fuse links can be
1
the amount of heating energy has become an insulator, system operates well before used at half of their AC rating
the fuse link will allow to pass completely isolating the the larger upstream fuse link. with a time constant of no 1
during fault clearing at high flow of current. more than 10mS. The time
short-circuit faults. I²t values The diagram here shows a NH discrimination constant is the rate of rise of 1
relevant for short-circuit faults representation of I²t during a fault current and should be as
Eaton’s Bussmann series
cannot be calculated from
the time-current or cut-off
half cycle of fault current. NH fuse links are easy to
close to a 50Hz AC half cycle
as possible.
1
I²t values give a good use on distribution networks
curves.
representation of the speed where discrimination Power loss 1
The published I²t figures of operation of a fuse link. between large and small
always show two values,
pre-arcing/total clearing and
A small I²t value would fuse links are required. This
can be achieved by applying
Every effort is made to
ensure the power loss of
1
indicate a very fast-acting
are representative of the area a discrimination factor of the fuse link is kept to a
under the first half cycle of
fuse link whereas a large I²t
value would indicate a fairly 1 to 1.6 without the need to minimum. Eaton provides 1
the fault current. slow operating fuse link. In check the fuse link data. For fuse links with some of the
all cases the total clearing example, by using a 100 A lowest power losses in the 1
• The pre-arcing value is fuse link downstream from industry. Power loss of the
I²t value of the fuse link
the area under the first
half cycle of fault current
must be smaller than the the main 160A fuse link, in fuse link is given off as heat
and this should be taken into
1
I²t value of the device to be the event of a fault condition,
showing on the graph in account when fitting fuse
yellow to the point just
protected in order for the the smaller 100A fuse link
is sure to operate before links into unventilated areas.
1
fuse link to provide adequate
before an arc occurs within the 160A fuse link, ensuring It is preferable that a fuse
protection against short-
the fuse link. This is due to
circuit faults. For fuse link discrimination. link has good airflow around 1
the element material being the body of the fuse link
discrimination (see definition
vaporised by the very high
of discrimination below) in to ensure cool running and 1
short-circuit current. prevent nuisance operation
distribution systems, the
of the fuse link due to
thermal stresses.
1
1
Should further information be required please contact Eaton’s application engineers: 00 44 (0) 1509 882 699 or buletechnical@eaton.com
Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com 7
NH Fuse links overview
1.1 NH Fuse links applications
1
1
1 Industrial
1 NH fuse links can be used
for protection of cables
1 and distribution circuits
1
1
1
Motor
1 NH fuse links can be
1 used for industrial
motor applications
1
1
8 Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com
NH Fuse links overview
Features of the NH DIN range
1.1
NH Dual indicator system from Eaton 1.1
• High breaking capacity • Insulated tag variants option Lug is voltage free
• 400, 500 and 690 V a.c.
available 1
• IEC 60269-1 and 2, DIN
• Dual indication 43620, VDE 0636-2, CE 1
Mark.
1
1
Lug is live part
1
1
1
Metal Gripping Lugs Insulated Metal Gripping Lugs 1
Features of the NH DIN range 1
Dual indicator system 1
Eaton’s patented dual indicator system provides clear indication,
ensuring extremely reliable local and remote* signalling, 1
decreasing fuse link replacement time and costs.
*with the use of an optional microswitch accessory
1
1
Low power loss
Eaton’s Bussmann series “low watts loss” fuse links reduce
1
overall operating costs and carbon footprint through lower
energy consumption and heat transfer to equipment. To find 1
out how much you can save, please contact our technical
applications department: buletechnical@eaton.com. 1
Globally compliant 1
Eaton’s Bussmann series NH fuse links are tested and comply 1
with IEC 60269-1 and 2, DIN 43620, VDE, CE, CCC (China),
RoHS and can be recycled, ensuring global acceptance.
1
Lead and cadmium free 1
Cd/Pb-free
Eaton is the world’s first true manufacturer of a complete
range of Lead and Cadmium free NH fuse links. Negating
1
any legislation concerns regarding the amount of hazardous
materials permissible within the fuse links. 1
Recycling 1
Eaton is dedicated to produce recyclable products and is a 1
member of an industry recognised recycling scheme. The
“HRC” symbol on Eaton’s Bussmann series NH fuse links
define the product suitable for recycling, limiting disposal cost.
1
1
1
1
1
1
1
1
Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com 9
NH Fuse links overview
1.1 Product range overview
Size
2 4 6 10 16 20 25 32 35 40 50 63 80 100 125 160 200 224 250 300 315 355 400 425 450 500 630 800 1000 1250 Page
1 000
00
10 16 25 35 50
63 80 100 125 160
23
24
gFF
gG
gG
1 02
2
35 40 50 63 80 100 125 160 200 224 250
250 300 315 355 400 425 450 500
44
45
1 03 250 315 355 400 46
3 315 355 400 425 450 500 630 800 47
1 4 500 630 800 1000 1250 48
000 2 4 6 10 16 20 25 32 35 40 50 63 51
1 00 50 63 80 100 125 160 52
1 50 63 80 100 125 160 200 224 250 53
690
gG
00 63 80 100 60
aM
1
Ordering key
1
Current rating 100
1 NH fuse link NH
1 Utilisation class G
Body size 000
1 Eaton’s Bussmann series B
10 Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com
NH Fuse links overview
Dimensions - mm
1.1
NH Fuse links dimensions - mm 1.1
41 Max
1
1
1
9
1
1
15.1 1
35±0.8 1
1
1
Indicator shown in 21 Max 1
operated position
1
7.5
1
1
1
1
Indicator
1
1
49.4 Max
78.7±1.2
49.7±0.7
1
1
1
1
1
1
1
1
Size 000
1
1
1
1
1
1
1
Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com 11
NH Fuse links overview
1.1 Dimensions - mm
1
1
1 15.1
1 35±0.8
1
1
1
1 29.55 Max
Indicator shown in
1 operated position
1
1
7
1
Indicator
1
1
49.4 Max
78.5±1.5
49.7±0.7
1
1
1
1
1
1
1
1
Size 00
1
1
1
1
1
1
12 Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com
NH Fuse links overview
Dimensions - mm
1.1
NH Fuse links dimensions - mm 1.1
47.8 Max
1
1
1
1
6
1
1
15.1 1
35±0.8
1
1
29.55 Max
1
1
Indicator shown in
operated position
1
1
6
1
1
1
1
Indicator
1
1
63.5 Max
66.5±0.5
125±1.3
1
1
1
1
1
1
1
1
1
Size 0
1
1
1
1
Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com 13
NH Fuse links overview
1.1 Dimensions - mm
1
1
15.1
1
40±0.8
1
1
1 29.55 Max
1
1 Indicator shown in
operated position
1
1
7
1
1
1
Indicator
1
67.7 Max
67.5±1.2
135±2.0
1
1
1
1
1
1
1
1
1 Size 01
1
1
1
1
1
1
14 Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com
NH Fuse links overview
Dimensions - mm
1.1
NH Fuse links dimensions - mm 1.1
52.9 Max
1
1
1
1
9
1
1
1
20.1
1
40±0.8 39.65 Max
1
Indicator shown in
operated position
1
1
1
1
7
1
Indicator 1
1
67.7 Max
67.5±1.2
135±2.0
1
1
1
1
1
1
1
1
1
Size 1
1
1
1
1
1
1
1
Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com 15
NH Fuse links overview
1.1 Dimensions - mm
1
1
1
6
1
1
1
20.1
1 48±0.8
39.65 Max
1
1
1 Indicator shown in
operated position
1
1
7
1
1 Indicator
1
1
67.7 Max
67.5±1.2
150±2.0
1
1
1
1
1
1
1
1
1
1
Size 02
1
1
1
1
1
16 Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com
NH Fuse links overview
Dimensions - mm
1.1
NH Fuse links dimensions - mm 1.1
61 Max 1
1
1
1
9
1
1
1
25.1
48±0.8
53.9 Max 1
1
1
Indicator shown in
operated position
1
1
7
1
Indicator 1
1
67.5±1.2
67.7 Max
150±2.0
1
1
1
1
1
1
1
1
1
Size 2 1
1
1
1
1
1
1
1
Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com 17
NH Fuse links overview
1.1 Dimensions - mm
1
1
1
1
25.1
1 53.9 Max
60±0.8
1
1
1
Indicator shown in
1 operated position
1
7
1
1 Indicator
1
1
67.7 Max
67.5±1.2
150±2.0
1
1
1
1
1
1
1
1
1
1 Size 3
1
1
1
1
18 Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com
NH Fuse links overview
Dimensions - mm
1.1
NH Fuse links dimensions - mm 1.1
76 Max
1
1
1
6
1
1
1
1
1
32.1
1
60±0.8
1
71.2 Max
1
1
Indicator shown in
operated position
1
1
6.5
1
1
Indicator
1
1
68.7 Max
68.5±1.2
150±2.0
1
1
1
1
1
1
1
1
Size 3
1
1
1
1
1
1
Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com 19
NH Fuse links overview
1.1 Dimensions - mm
1
1
1
1
1
1 49.3±0.3
1 87±0.8
1
1
1 105 Max
1
1
1 Indicator
1
1
1
200.0±3.0
150.0±2.0
62.0±2.5
68.0±2.5
80 Max
1
1
1
1
1
1
16.0±0.5
1 32.0+0.5
0.0
1
1
1
1
1
1
Size 4 NH 690 V a.c. only.
1 Please contact buletechnical@eaton.com for dimensions of size 4 500 Volts
Data sheet 10623
20 Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com
NH Fuse links - 400 V a.c. - class gFF
Overview
1.2
400 V a.c. - class gFF - 2 to 630 amps - sizes 000 to 3 1.2
Description Catalogue numbers Class of operation Technical data 1
Eaton’s Bussmann series structure • gFF • Sizes: 000, 00, 1, 02, 2
NH 400 V a.c. gFF fuse links (amp)NHFF(size)BI-400 e.g. Standards / approvals and 3 1
have been designed for the 50NHFF000BI-400 with • Voltage: 400 V a.c.
protection of low voltage
installations where expected
insulated metal gripping lugs • IEC 60269 part 1 • Current: 2 to 630 A 1
• Dimensionally in • Rated breaking capacity:
short circuit currents are low. accordance to IEC 60269 120 kA, 80 kA for NH00 80 1
part 2 and DIN 43620 part A and 160 A
1 and 3 • Rated frequency: 50Hz 1
Optional microswitch 1
NH Fuse
body size
Suitable
microswitch
1
Size 000 170H0236 1
Size 00 170H0236
Size 1 170H0236
1
Size 02 BVL50 1
SIze 2 170H0235 or 170H0236
Size 3 170H0235 1
Compatible fuse holders
1
Description Type
Data sheet
number
1
Fuse bases 1-pole DIN-Rail mounting SD-D 10163 1
Screw mounting SD-S 10163
Fuse bases 3-pole DIN-Rail mounting TD-D 10163 1
Fuse bases accessories IP20, Shroud and phase barriers kits 10163
1
Fuse rails Vertical - EBF 10240
Fuse switch disconnectors Vertical - EBV 10275 1
Horizontal - EBH Size 000 10292
1
Horizontal - EBH Size 00 to 4 10293
1
1
Environmental Packaging Features: 1
• Recyclable • All fuse links are packed in • Reliable dual indicator 1
• RoHS compliant threes. system
• Lead and cadmium free. • Ideal for utility network 1
protection, especially in
large rural areas 1
• Low temperature rise
1
1
1
1
1
1
1
1
Data sheet 10623
Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com 21
NH Fuse links - 400 V a.c. - class gFF
1.2 Catalogue numbers
22 Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com
NH Fuse links - 400 V a.c. - class gFF
Time-current characteristics and technical data
1.2
400 V a.c. - class gFF - 10 to 50 amps - size 000 1.2
Time-current characteristics 1
10000
1
1
1
1000 10A 1
16A
25A 1
35A
50A 1
100
1
1
Pre-arcing Time (s)
1
1
10 1
1
1
1
1
1
1
1
0.1
1
1
1
0.01 1
10 100 1000 10000
Prospective current (A)
1
Technical data
I²t (Amps² seconds)
1
Catalogue numbers
with insulated metal
gripping lugs
Fuse link
size
Current
(amps)
Voltage
(V a.c.)
Minimum
Pre-arcing
*I1 120 kA at
400 V a.c.
Watts
loss (W)
Net weight
per fuse (kg) 1
10NHFF000BI-400 000 10 400 44 180 1.7 0.113
16NHFF000BI-400 16 160 600 2.3
1
25NHFF000BI-400 25 1000 3200 2.3 1
35NHFF000BI-400 35 2700 8300 2.7
50NHFF000BI-400 50 3100 8800 5.4 1
* I1 is the maximum breaking capacity test at voltage according to IEC 60269-1 and 2 requirements 1
1
1
1
Data sheet 10623
Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com 23
NH Fuse links - 400 V a.c. - class gFF
1.2 Time-current characteristics and technical data
1
1
63A
1 100
80A
100A
1 125A
Time in seconds (s)
1 160A
1
1 10
1
1
1 1
1
1
1
0.1
1
1
1
1 0.01
10 100 1000 10000
Current in Amps (A)
1
Technical data
1 I²t (Amps² seconds)
Catalogue numbers
1 * I1 is the maximum breaking capacity test at voltage according to IEC 60269-1 and 2 requirements
1
1
1
Data sheet 10623
24 Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com
NH Fuse links - 400 V a.c. - class gFF
Time-current characteristics and technical data
1.2
400 V a.c. - class gFF - 35 to 250 amps - size 1 1.2
Time-current characteristics 1
10000
1
1
35A
50A 1
63A
1000
80A 1
100A
125A
1
160A 1
200A
224A 1
100
250A
1
Time in seconds (s)
1
1
10
1
1
1
1
1
1
1
1
0.1
1
1
1
0.01 1
10 100 1000 10000
Current in Amps (A) 1
Technical data 1
I²t (Amps² seconds)
Catalogue numbers
with insulated metal Fuse link Current Voltage Minimum *I1 120 kA at Watts Net weight
1
gripping lugs size (amps) (V a.c.) Pre-arcing 400 V a.c. loss (W) per fuse (kg)
35NHFF1BI-400 1 35 400 1600 4400 5.5 0.348 1
50NHFF1BI-400 50 3200 9900 6
63NHFF1BI-400 63 6400 18,700 7.1 1
80NHFF1BI-400 80 14,600 39,400 7.4
100NHFF1BI-400 100 23,700 72,300 11
1
125NHFF1BI-400 125 35,100 92,400 11.5 1
160NHFF1BI-400 160 75,600 187,000 14
200NHFF1BI-400 200 109,000 260,000 18 1
224NHFF1BI-400 224 130,000 310,000 22
250NHFF1BI-400 250 186,000 425,000 24 1
* I1 is the maximum breaking capacity test at voltage according to IEC 60269-1 and 2 requirements 1
Data sheet 10623
Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com 25
NH Fuse links - 400 V a.c. - class gFF
1.2 Time-current characteristics and technical data
1
1
1 100
1
Time in seconds (s)
1
1
1 10
1
1
1 1
1
1
1
0.1
1
1
1
1 0.01
100 1000 10000 100000
Current in Amps (A)
1
Technical data
1 I²t (Amps² seconds)
Catalogue numbers
26 Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com
NH Fuse links - 400 V a.c. - class gFF
Time-current characteristics and technical data
1.2
400 V a.c. - class gFF - 315 to 400 amps - size 2 1.2
Time-current characteristics 1
10000
1
1
1
1000
315A 1
355A
400A
1
1
100
1
1
Time in seconds (s)
1
1
10
1
1
1
1 1
1
1
1
0.1
1
1
1
0.01
100 1000 10000 100000
1
Current in Amps (A)
1
Technical data
I²t (Amps² seconds)
1
Catalogue numbers
with insulated metal Fuse link Current Voltage Minimum *I1 120 kA at Watts Net weight
gripping lugs size (amps) (V a.c.) Pre-arcing 400 V a.c. loss (W) per fuse (kg) 1
315NHFF2BI-400 2 315 400 152,000 472,000 33 0.515
355NHFF2BI-400 355 242,000 726,000 33 1
400NHFF2BI-400 400 354,000 1,070,000 34
1
* I1 is the maximum breaking capacity test at voltage according to IEC 60269-1 and 2 requirements
1
1
1
1
1
Data sheet 10623
Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com 27
NH Fuse links - 400 V a.c. - class gFF
1.2 Time-current characteristics and technical data
1
450A
1
500A
1 100
630A
1
Time in seconds (s)
1
1
10
1
1
1
1 1
1
1
1
0.1
1
1
1
1 0.01
100 1000 10000 100000
Current in Amps (A)
1
Technical data
1 I²t (Amps² seconds)
Catalogue numbers
with insulated metal Fuse link Current Voltage Minimum *I1 120 kA at Watts Net weight
1 gripping lugs size (amps) (V a.c.) Pre-arcing 400 V a.c. loss (W) per fuse (kg)
450NHFF3BI-400 3 450 400 325,000 980,000 46 0.904
1 500NHFF3BI-400 500 456,000 1,370,000 47
630NHFF3BI-400 630 1,230,000 3,700,000 48
1
* I1 is the maximum breaking capacity test at voltage according to IEC 60269-1 and 2 requirements
1
1
1
1
1
Data sheet 10623
28 Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com
NH Fuse links - 400 V a.c. - class gG/gL
Overview
1.3
400 V a.c. - class gG/gL - 2 to 630 amps - sizes 000 to 3 1.3
Description Catalogue numbers Class of operation Technical data 1
A square bodied range of structure • gL/gG. • Sizes 000 to 3
industrial fuse links for a wide • (amp)NHG(size)B-400 • Voltage: 400 V a.c. 1
variety of applications. e.g. 100NHG02B-400 Standards / approvals • Current: 2 to 630 A
with conducting metal • IEC 60269-1 and 2, VDE • Rated breaking capacity: 1
gripping lugs 0636, DIN 43620 and CE. 120 kA AC
• (amp)NHG(size)BI-400 • Rated frequency: 50Hz 1
e.g. 100NHG000BI-400 • Operating frequency:
with insulated metal
gripping lugs
45-62Hz. 1
1
Optional microswitch
1
NH Fuse body Suitable
size microswitch
1
Size 000 170H0236
Size 00 170H0236 1
Size 01 170H0235
Size 1 170H0236 1
Size 02 BVL50
SIze 2 170H0235 or 170H0236 1
Size 03 BVL50
Size 3 170H0235
1
Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com 29
NH Fuse links - 400 V a.c. - class gG/gL
1.3 Catalogue numbers
1
1
1
1
Data sheet 720099
30 Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com
NH Fuse links - 400 V a.c. - class gG/gL
Time-current characteristics and technical data
1.3
400 V a.c. - class gG/gL - 2 to 100 amps - size 000 1.3
Time-current characteristics 1
10000
6 1
4
100 1
2 80
63
1
1000
6
50 1
40
4
35
1
2
32
1
100 25
6 20 1
4 16
1
10
2
1
Time in seconds (s)
10
6
1
4 1
2
1
1
6
1
4
1
2
1
0.1
6
1
6
4
4 1
2 2
1
0.01
2 4 6 8 10 2 4 6
Current in Amps (A)
8 100 2 4 6 8 1000 2 1
Technical data 1
Catalogue
numbers with
Catalogue
numbers with
I²t (Amps² seconds) 1
metal gripping insulated metal Fuse link Current Voltage Minimum *I1 120 kA at Watts loss Net weight
lugs gripping lugs size (amps) (V a.c.) Pre-arcing 400 V a.c. (W) per fuse (kg) 1
2NHG000B-400 2NHG000BI-400 000 2 400 3.5 5.5 0.8 0.133
4NHG000B-400 4NHG000BI-400 4 6 10.5 1.4 1
6NHG000B-400 6NHG000BI-400 6 14 19 2.2
10NHG000B-400 10NHG000BI-400 10 60 175 1.5
1
16NHG000B-400 16NHG000BI-400 16 240 710 2.3
1
20NHG000B-400 20NHG000BI-400 20 584 1800 2.2
25NHG000B-400 25NHG000BI-400 25 1000 2800 3.1 1
32NHG000B-400 32NHG000BI-400 32 2400 9600 2.8
35NHG000B-400 35NHG000BI-400 35 2900 11,300 2.8 1
40NHG000B-400 40NHG000BI-400 40 4000 16,400 3
50NHG000B-400 50NHG000BI-400 50 4000 12,000 3.4 1
63NHG000B-400 63NHG000BI-400 63 6000 20,400 4.5
80NHG000B-400 80NHG000BI-400 80 9900 35,700 4.7
1
100NHG000B-400 100NHG000BI-400 100 18,100 39,800 5.2
1
* I1 is the maximum breaking capacity test at voltage according to IEC 60269-1 and 2 requirements
1
Data sheet 720099
Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com 31
NH Fuse links - 400 V a.c. - class gG/gL
1.3 Time-current characteristics and technical data
1.3 400 V a.c. - class gG/gL - 125 and 160 amps - size 00
1 Time-current characteristics
10000
1 6
1 4
160
1 2 125
1 1000
6
1
4
1
2
1
100
1 6
1 4
1 2
Time in seconds (s)
1 10
1 6
4
1
2
1
1
1 6
1 4
1 2
1 0.1
1 6
4
1
2
1
0.01
1 6 8 10 2 4 6 8 100 2 4 6 8 1000 2 4 6
1 * I1 is the maximum breaking capacity test at voltage according to IEC 60269-1 and 2 requirements
1
1
1
1
Data sheet 720099
32 Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com
NH Fuse links - 400 V a.c. - class gG/gL
Time-current characteristics and technical data
1.3
400 V a.c. - class gG/gL - 35 to 250 amps - sizes 01 & 1 1.3
Time-current characteristics 1
10000
6 1
250
4
224 1
2 200
1
160
1000
6
125 1
4 100
80
1
2
63 1
100 50
6 40
1
4 35 1
2
1
Time in seconds (s)
6
1
4 1
2
1
1
1
6
4 1
2
1
0.1
1
6
4 1
2 1
0.01
10 2 4 6 8 100 2 4 6 8 1000 2 4 6 1
Current in Amps (A)
1
Technical data
Catalogue Catalogue
1
I²t (Amps² seconds)
numbers with numbers with
metal gripping insulated metal Fuse link Current Voltage Minimum *I1 120 kA at Watts Net weight 1
lugs gripping lugs size (amps) (V a.c.) Pre-arcing 400 V a.c. loss (W) per fuse (kg)
35NHG01B-400 35NHG01BI-400 01 35 400 2400 7600 4.9 0.269 1
40NHG01B-400 40NHG01BI-400 40 3300 10,600 5
50NHG01B-400 50NHG01BI-400 50 4200 10,400 4.7 1
63NHG01B-400 63NHG01BI-400 63 6600 16,300 5.6
80NHG01B-400 80NHG01BI-400 80 9600 33,600 5.6 1
100NHG01B-400 100NHG01BI-400 100 16,000 56,000 6.8
125NHG01B-400 125NHG01BI-400 125 24,000 86,400 8.8
1
160NHG01B-400 160NHG01BI-400 160 53,000 111,300 8.9 1
200NHG1B-400 200NHG1BI-400 1 200 400 89,000 232,000 12 0.387
224NHG1B-400 224NHG1BI-400 224 119,000 322,000 12 1
250NHG1B-400 250NHG1BI-400 250 171,000 479,000 14
* I1 is the maximum breaking capacity test at voltage according to IEC 60269-1 and 2 requirements
1
1
1
Data sheet 720099
Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com 33
NH Fuse links - 400 V a.c. - class gG/gL
1.3 Time-current characteristics and technical data
1 6 400
4 355
1 315
2
1 1000
250
224
1 6
200
4
1 2
160
125
1 100
100
6
1 4
80
63
1 2
50
Time in seconds (s)
1 10 40
6 35
1 4
1 2
630
1 1
1 4
1 2
0.1
1 6
1 4
2
1
0.01
6 8 100 2 4 6 8 1000 2 4 6 8 10000 2
1 Current in Amps (A)
1 Technical data
Catalogue Catalogue I²t (Amps² seconds)
1 numbers with numbers with
*I1 120 kA at
metal gripping insulated metal Fuse link Current Voltage Minimum Watts Net weight
lugs gripping lugs size (amps) (V a.c.) Pre-arcing 400 V a.c. loss (W) per fuse (kg)
1 35NHG02B-400 35NHG02BI-400 02 35 400 2400 7600 4.4 0.402
34 Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com
NH Fuse links - 400 V a.c. - class gG/gL
Time-current characteristics and technical data
1.3
400 V a.c. - class gG/gL - 250 to 630 amps - sizes 03 & 3 1.3
Time-current characteristics 1
10000
6
1
4
1
2 630 1
500
1000 1
400
6
355 1
4
315 1
2
250
1
100
6
1
4 1
1
Time in seconds (s)
10 1
6
1
4
1
2
1
1
6
1
4 1
2 1
0.1 1
6
1
4
1
2
1
0.01
2 4 6 8 100 2 4 6
Current in Amps (A)
8 1000 2 4 6 8 10,000
1
Technical data 1
Catalogue
numbers with
Catalogue
numbers with
I²t (Amps² seconds) 1
metal gripping insulated metal Fuse link Current Voltage Minimum *I1 120 kA at Watts Net weight
lugs gripping lugs size (amps) (V a.c.) Pre-arcing 400 V a.c. loss (W) per fuse (kg) 1
250NHG03B-400 250NHG03BI-400 03 250 400 115,000 379,500 18 0.634
315NHG03B-400 315NHG03BI-400 315 280,000 924,000 19 1
355NHG03B-400 355NHG03BI-400 355 350,000 1,155,000 22
400NHG03B-400 400NHG03BI-400 400 504,000 1,663,000 24
1
500NHG3B-400 500NHG3BI-400 3 500 400 686,000 2,605,000 30 1.043
1
630NHG3B-400 630NHG3BI-400 630 1,590,000 6,201,000 36
* I1 is the maximum breaking capacity test at voltage according to IEC 60269-1 and 2 requirements 1
1
1
Data sheet 720099
Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com 35
NH Fuse links - 500 V a.c. - class gG/gL
1.4 Overview
1 Size 02 BVL50
SIze 2 170H0235 or 170H0236
1 Size 03 BVL50
Size 3 170H0235
1
Size 4 Not available
1
Compatible fuse holders
1 Data sheet
Description Type number
1 Fuse bases 1-pole DIN-Rail mounting SD-D 10163
1
1
1
1
1
1
Data sheet 10164
36 Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com
NH Fuse links - 500 V a.c. - class gG/gL
Catalogue numbers
1.4
500 V a.c. - class gG/gL - 2 to 1250 amps - sizes 000 to 01 1.4
Catalogue numbers 1
gG/gL Dual indicator
Current Voltage Voltage conducting metal Insulated metal Pack 1
Size (amps) (V a.c.) gripping lugs gripping lugs quantity
000 2 500 2NHG000B 2NHG000BI 3 1
4 4NHG000B 4NHG000BI
6 6NHG000B 6NHG000BI 1
10 10NHG000B 10NHG000BI
16 16NHG000B 16NHG000BI
1
20 20NHG000B 20NHG000BI
1
25 25NHG000B 25NHG000BI
32 32NHG000B 32NHG000BI 1
35 35NHG000B 35NHG000BI
40 40NHG000B 40NHG000BI 1
50 50NHG000B 50NHG000BI
63 63NHG000B 63NHG000BI 1
80 80NHG000B 80NHG000BI
100 100NHG000B 100NHG000BI
1
00 50 500 50NHG00B 50NHG00BI* 3
1
63 63NHG00B 63NHG00BI*
80 80NHG00B 80NHG00BI* 1
100 100NHG00B 100NHG00BI*
125 125NHG00B 125NHG00BI 1
160 160NHG00B 160NHG00BI
0 6 500 6NHG0B - 3 1
10 10NHG0B -
16 16NHG0B -
1
20 20NHG0B -
1
25 25NHG0B -
32 32NHG0B - 1
35 35NHG0B -
40 40NHG0B - 1
50 50NHG0B -
63 63NHG0B - 1
80 80NHG0B -
100 100NHG0B -
1
125 125NHG0B -
1
160 160NHG0B -
01 6 500 6NHG01B 6NHG01BI 3 1
10 10NHG01B 10NHG01BI
16 16NHG01B 16NHG01BI 1
20 20NHG01B 20NHG01BI
25 25NHG01B 25NHG01BI 1
32 32NHG01B 32NHG01BI
35 35NHG01B 35NHG01BI
1
40 40NHG01B 40NHG01BI
50 50NHG01B 50NHG01BI
1
63 63NHG01B 63NHG01BI 1
80 80NHG01B 80NHG01BI
100 100NHG01B 100NHG01BI 1
125 125NHG01B 125NHG01BI
160 160NHG01B 160NHG01BI 1
* Available upon request 1
1
1
Data sheet 10164
Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com 37
NH Fuse links - 500 V a.c. - class gG/gL
1.4 Catalogue numbers
1 63 63NHG02B 63NHG02BI
80 80NHG02B 80NHG02BI
1 100 100NHG02B 100NHG02BI
125 125NHG02B 125NHG02BI
1 160 160NHG02B 160NHG02BI
200 200NHG02B 200NHG02BI
1 224 224NHG02B 224NHG02BI
250 250NHG02B 250NHG02BI
1 2 250 500 250NHG2B 250NHG2BI 3
1
1
1
Data sheet 10164
38 Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com
NH Fuse links - 500 V a.c. - class gG/gL
Time-current characteristics and technical data
1.4
500 V a.c. - class gG/gL - 2 to 100 amps - size 000 1.4
Time-current characteristics 1
10000
6
1
4
100 1
2 80
1
63
1000
50
1
6
4
40
1
35
2
32
1
100 25 1
6 20
4
1
16
2
10 1
Time in seconds (s)
10
1
6 1
4
1
2
1
1
6
1
4 1
2 1
0.1
1
6 6
4 1
4
2 2 1
0.01 1
2 4 6 8 10 2 4 6 8 100 2 4 6 8 1000 2
Current in Amps (A) 1
Technical data 1
Catalogue Catalogue I²t (Amps² seconds)
numbers with
metal gripping
numbers with
insulated metal Fuse link Current Voltage Minimum *I1 120 kA at Watts Net weight
1
lugs gripping lugs size (amps) (V a.c.) Pre-arcing 500 V a.c. loss (W) per fuse (kg)
2NHG000B 2NHG000BI 000 2 500 3.5 6 3.9 0.130 1
4NHG000B 4NHG000BI 4 6 12 1.8
6NHG000B 6NHG000BI 6 14 21 2 1
10NHG000B 10NHG000BI 10 58 290 1.5
16NHG000B 16NHG000BI 16 234 1200 2.3 1
20NHG000B 20NHG000BI 20 490 2500 2.2
25NHG000B 25NHG000BI 25 920 4600 3.1 1
32NHG000B 32NHG000BI 32 1800 9000 3.4
35NHG000B 35NHG000BI 35 2400 11,800 3.7 1
40NHG000B 40NHG000BI 40 3300 16,500 4
50NHG000B 50NHG000BI 50 5900 29,500 4.9 1
63NHG000B 63NHG000BI 63 6300 24,900 4.6
80NHG000B
100NHG000B
80NHG000BI
100NHG000BI
80
100
9800
18,100
38,900
72,300
6.3
7.4
1
* I1 is the maximum breaking capacity test at voltage according to IEC 60269-1 and 2 requirements 1
Data sheet 10164
Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com 39
NH Fuse links - 500 V a.c. - class gG/gL
1.4 Time-current characteristics and technical data
1 6 80
4 63
1
2 50
1 100
1 6
4
1
Time in seconds (s)
1 10
6
1 4
1 2
1 1
6
1 4
1 2
1 0.1
6
1 4
1 2
0.01
1 10 2 4 6 8 100 2 4 6 8 1000 2 4 6
1
1
1
1
1
Data sheet 10164
40 Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com
NH Fuse links - 500 V a.c. - class gG/gL
Time-current characteristics and technical data
1.4
500 V a.c. - class gG/gL - 6 to 160 amps - size 0 1.4
Time-current characteristics 1
10 000
6
160
125
1
4
100 1
2
1
1 000
6 1
4
80
1
2 63
50
1
100
6
40
1
4 35
32
1
2
25
1
Time in seconds (s)
20
10
6
16 1
4 10
1
2
1
1
6 1
4
1
2
6 1
0.1
6 1
4
1
2
1
0.01
6 8 10 2 4 6 8 100 2 4 6 8 1000 2 4 6
1
Current in Amps (A)
Technical data 1
Catalogue
I²t (Amps² seconds) 1
numbers with Fuse link Current Voltage Minimum *I1 120 kA at Watts Net weight
metal gripping lugs size (amps) (V a.c.) Pre-arcing 500 V a.c. loss (W) per fuse (kg) 1
6NHG0B 0 6 500 14 21 2 0.260
10NHG0B 10 58 290 2 1
16NHG0B 16 240 1200 3
20NHG0B 20 490 2500 3.5
1
25NHG0B 25 1200 5600 3.2
1
32NHG0B 32 1800 9000 4.8
35NHG0B 35 2400 11,800 4.7 1
40NHG0B 40 3300 16,500 5
50NHG0B 50 5600 27,800 6.3 1
63NHG0B 63 6600 26,100 5.6
80NHG0B 80 9800 38,900 7.1 1
100NHG0B 100 20,600 82,300 7.5
125NHG0B 125 25,000 125,000 11.8
1
160NHG0B 160 62,000 310,000 12.3
1
* I1 is the maximum breaking capacity test at voltage according to IEC 60269-1 and 2 requirements
1
Data sheet 10164
Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com 41
NH Fuse links - 500 V a.c. - class gG/gL
1.4 Time-current characteristics and technical data
1 6
4
1
2
1 1 000
1 6 160
4 125
1 2
100
80
1 100
63
1 6
4
50
40
1 2 35
Time in seconds (s)
1 10
32
25
6
1 4
1 2
1 1 20
6 16
1 4 10
1 2
0.1
1 6 6
1 4
2
1
0.01
1 4 6 8 10 2 4 6 8 100 2 4 6 8 1000 2 4
42 Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com
NH Fuse links - 500 V a.c. - class gG/gL
Time-current characteristics and technical data
1.4
500 V a.c. - class gG/gL - 50 to 355 amps - size 1 1.4
Time-current characteristics 1
10000
6
355 1
315
4
250 1
2 224
1
200
1000
160
1
6
4 125
1
2
100
1
80
100
63 1
6
4
50 1
1
Time in seconds (s)
10 1
6
1
4
2
1
1
1
6 1
4
1
2
1
0.1
6
1
4
1
2
1
0.01
4 6 8 100 2 4 6 8 1000 2 4 6 8 10000 2 4 1
Current in Amps (A)
1
Technical data
Catalogue Catalogue I²t (Amps² seconds)
1
numbers with numbers with
metal gripping
lugs
insulated metal
gripping lugs
Fuse link
size
Current
(amps)
Voltage
(V a.c.)
Minimum
Pre-arcing
*I1 120 kA at
500 V a.c.
Watts
loss (W)
Net weight
per fuse (kg)
1
50NHG1B 50NHG1BI 1 50 500 6350 18,000 6.4 0.390 1
63NHG1B 63NHG1BI 63 6800 23,000 5.6
80NHG1B 80NHG1BI 80 10,500 31,200 7.7 1
100NHG1B 100NHG1BI 100 22,000 68,200 8.2
125NHG1B 125NHG1BI 125 29,000 82,000 13 1
160NHG1B 160NHG1BI 160 62,000 310,000 12.3
200NHG1B 200NHG1BI 200 97,000 368,600 15 1
224NHG1B 224NHG1BI 224 124,000 471,200 18
250NHG1B 250NHG1BI 250 151,300 574,900 19
1
315NHG1B - 315 440 320,000 750,000 22 1
355NHG1B - 355 320,000 750,000 32
* I1 is the maximum breaking capacity test at voltage according to IEC 60269-1 and 2 requirements 1
1
Data sheet 10164
Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com 43
NH Fuse links - 500 V a.c. - class gG/gL
1.4 Time-current characteristics and technical data
1000 224
1 6 200
1 4 160
125
1 2
100
1 100
80
6 63
1 4 50
1 2 40
1 35
Time in seconds (s)
10
6
1 4
1 2
1 1
1 6
4
1
2
1
0.1
1 6
4
1
2
1
0.01
1 6 8 100 2 4 6 8 1000 2 4 6 8 10000 2
1
Data sheet 10164
44 Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com
NH Fuse links - 500 V a.c. - class gG/gL
Time-current characteristics and technical data
1.4
500 V a.c. - class gG/gL - 250 to 500 amps - size 2 1.4
Time-current characteristics 1
10000
6
400
1
355
4
315 1
2
250
1
1000
6 1
4
1
2
1
100
6 1
4
1
Time in seconds (s)
2
1
10
6 1
300
4
425 1
2 450
1 500 1
6 1
4
1
2
0.1
1
6 1
4
2
1
0.01 1
6 8 100 2 4 6 8 1000 2 4 6 8 10000 2
Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com 45
NH Fuse links - 500 V a.c. - class gG/gL
1.4 Time-current characteristics and technical data
1 100
6
1 4
Time in seconds (s)
2
1
10
1 6
4
1
2
1 1
1 6
4
1 2
1 0.1
6
1 4
2
1
0.01
2 4 6 8 100 2 4 6 8 1000 2 4 6 10,000
1 Current in Amps (A)
1 Technical data
1 Catalogue
numbers with
Catalogue
numbers with
I²t (Amps² seconds)
metal gripping insulated metal Fuse link Current Voltage Minimum *I1 120 kA at Watts Net weight
1 lugs gripping lugs size (amps) (V a.c.) Pre-arcing 500 V a.c. loss (W) per fuse (kg)
250NHG03B 250NHG03BI 03 250 500 160,800 642,900 20 0.640
1 315NHG03B 315NHG03BI 315 361,700 1,446,500 21
355NHG03B 355NHG03BI 355 446,500 1,785,800 27
1 400NHG03B 400NHG03BI 400 642,900 2,571,500 30
1 * I1 is the maximum breaking capacity test at voltage according to IEC 60269-1 and 2 requirements
1
1
1
1
1
1
1
1
Data sheet 10164
46 Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com
NH Fuse links - 500 V a.c. - class gG/gL
Time-current characteristics and technical data
1.4
500 V a.c. - class gG/gL - 315 to 800 amps - size 3 1.4
Time-current characteristics 1
10 000
6 630
1
4
500 1
2 450
425
1
1000
6
400 1
4 355
315
1
2
1
100
6 1
4
1
Time in seconds (s)
2 800
1
10
6 1
4
1
2
1
1
6 1
4
1
2
1
0.1
6 1
4
1
2
0.01
1
2 4 6 8 100 2 4 6 8 1000 2 4 6 10,000
Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com 47
NH Fuse links - 500 V a.c. - class gG/gL
1.4 Time-current characteristics and technical data
1 5
500
0
1000
1250
800
1 2
0
0
2
630
104
1 5
1 2
1 10 3
5
1
2
1 10 2
Time in seconds (s)
1 5
2
1
101
1 5
1 2
0
10
1 5
1 2
1 10-1
5
1
2
1 10-2
1
4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8 2 3 4 5 6 8
1 100 1.000 10.000 100.000 I (A)
Technical data
1
I²t (Amps² seconds)
Catalogue
1 numbers with
metal gripping lugs
Fuse link
size
Current
(amps)
Voltage
(V a.c.)
Minimum
Pre-arcing
**I1 120 kA at
500 V a.c.
Watts
loss (W)
Net weight
per fuse (kg)
48 Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com
NH Fuse links - 690 V a.c. - class gG/gL
Overview
1.5
Description Catalogue numbers Class of operation Technical data 1.5
A square bodied range of structure • gL/gG. • Sizes 000 to 4
industrial fuse links for a wide • (amp)NHG(size)B-690 e.g. Standards / approvals • Voltage: 690 V a.c. 1
variety of applications. 2NHG000B-690. • Current: 2 to 800 A
• IEC 60269-1 and 2, DIN
43620 Part 1 and 3.
• Rated breaking capacity: 1
120 kA
• Operating frequency: 1
45-62Hz.
Optional microswitch 1
NH Fuse
body size
Suitable
microswitch
1
Size 000 170H0236 1
Size 00 170H0236
Size 1 170H0236 1
SIze 2 170H0235 or 170H0236
1
Size 3 170H0235
Size 4 Not available 1
Compatible fuse holders
1
Data sheet
1
Description Type number
Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com 49
NH Fuse links - 690 V a.c. - class gG/gL
1.5 Catalogue numbers
1 * Size 4 is a fuse link with single indication fuse link with slotted end tags
Please consult us should you wish to order 500 Volts size 4 buletechnical@eaton.com or 00 44 (0) 1509 882 699
1
1
1
1
1
1
1
1
Data sheet 720109
50 Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com
NH Fuse links - 690 V a.c. - class gG/gL
Time-current characteristics and technical data
1.5
690 V a.c. - class gG/gL - 2 to 63 amps - size 000 1.5
Time-current characteristics 1
10000
6 1
4
1
2
63 1
1000
6
50
1
40
4
35 1
2
32
1
100 25
6 20 1
4 16
10
1
2
1
Time in seconds (s)
10
6 1
4
1
2
1
1
6 1
4
1
2
1
0.1
6
6
1
4
4
1
2 2
1
0.01
2 4 6 8 10 2 4 6 8 100 2 4 6 8 1000 2
Current in Amps (A) 1
Technical data 1
Catalogue Catalogue I²t (Amps² seconds)
numbers with numbers with 1
metal gripping insulated metal Fuse link Current Voltage Minimum *I1 120 kA at Watts Net weight
690 V a.c.
lugs gripping lugs size (amps) (V a.c.) Pre-arcing loss (W) per fuse (kg)
1
2NHG000B-690 - 000 2 690 3.5 8 4 0.118
4NHG000B-690 - 4 6 16 2 1
6NHG000B-690 - 6 14 25 2
10NHG000B-690 10NHG000BI-690 10 60 400 1.5 1
16NHG000B-690 16NHG000BI-690 16 240 1200 2.5
20NHG000B-690 20NHG000BI-690 20 500 2500 2.5 1
25NHG000B-690 25NHG000BI-690 25 920 4400 3.5
32NHG000B-690 32NHG000BI-690 32 1800 9600 3.5
1
35NHG000B-690 35NHG000BI-690 35 2800 15,000 4
40NHG000B-690 40NHG000BI-690 40 3300 15,000 4
1
50NHG000B-690 50NHG000BI-690 50 6100 26,500 5.5 1
63NHG000B-690 63NHG000BI-690 63 6500 30,500 5.5
* I1 is the maximum breaking capacity test at voltage according to IEC 60269-1 and 2 requirements 1
1
1
Data sheet 720109
Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com 51
NH Fuse links - 690 V a.c. - class gG/gL
1.5 Time-current characteristics and technical data
1 4
160
1 2 125
1 1000
100
80
1 6
4 63
1 50
2
1
100
1 6
1 4
1 2
Time in seconds (s)
1 10
1 6
4
1
2
1
1
1 6
1 4
1 2
1 0.1
1 6
4
1
2
1
0.01
1 6 8 10 2 4 6 8 100 2 4 6 8 1000 2 4 6
1
1
Data sheet 720109
52 Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com
NH Fuse links - 690 V a.c. - class gG/gL
Time-current characteristics and technical data
1.5
690 V a.c. - class gG/gL - 50 to 250 amps - size 1 1.5
Time-current characteristics 1
10000
6
250
1
4
2
224 1
200
1000 160 1
125
6
4 100 1
80
2 63 1
100
6
50
1
4
1
2
1
10
Time in seconds (s)
6 1
4
2
1
1 1
6
4 1
2
1
0.1
6
1
4
1
2
0.01
1
4 6 8 100 2 4 6 8 1000 2 4 6 8 10000 2 4
Current in amps (a) 1
Technical data 1
Catalogue Catalogue I²t (Amps² seconds)
numbers with numbers with
*I1 120 kA at
1
metal gripping insulated metal Fuse link Current Voltage Minimum Watts Net weight
lugs gripping lugs size (amps) (V a.c.) Pre-arcing 690 V a.c. loss (W) per fuse (kg)
50NHG1B-690 50NHG1BI-690 1 50 690 6350 26,500 6.4 0.380
1
63NHG1B-690 63NHG1BI-690 63 6800 36,000 5.6
1
80NHG1B-690 80NHG1BI-690 80 10,500 47,500 7.7
100NHG1B-690 100NHG1BI-690 100 22,000 105,000 8.2 1
125NHG1B-690 125NHG1BI-690 125 29,000 120,000 13
160NHG1B-690 160NHG1BI-690 160 71,000 240,000 13 1
200NHG1B-690 200NHG1BI-690 200 105,000 350,000 17
224NHG1B-690 224NHG1BI-690 224 120,000 430,000 19 1
250NHG1B-690 250NHG1BI-690 250 150,000 520,000 22
1
* I1 is the maximum breaking capacity test at voltage according to IEC 60269-1 and 2 requirements
1
1
1
1
1
1
Data sheet 720109
Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com 53
NH Fuse links - 690 V a.c. - class gG/gL
1.5 Time-current characteristics and technical data
1 1000
315
250
6
1 4 224
200
1 2
1 100
6
1 4
2
1
Time in seconds (s)
10
1 6
4
1 2
1 1
6
1 4
1 2
0.1
1 6
1 4
2
1
0.01
6 8 100 2 4 6 8 1000 2 4 6 8 10000 2
1 Current in amps (a)
1 Technical data
Catalogue Catalogue I²t (Amps² seconds)
1 numbers with numbers with
*I1 120 kA at
metal gripping insulated metal Fuse link Current Voltage Minimum Watts Net weight
lugs gripping lugs size (amps) (V a.c.) Pre-arcing 690 V a.c. loss (W) per fuse (kg)
1 200NHG2B-690 200NHG2BI-690 2 200 690 99,000 385,000 18 0.620
54 Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com
NH Fuse links - 690 V a.c. - class gG/gL
Time-current characteristics and technical data
1.5
690 V a.c. - class gG/gL - 250 to 500 amps - size 3 1.5
Time-current characteristics 1
10000
6 1
4
2
1
500
1000 425 1
6 400
4 355
1
2
315
250
1
100
1
6
4 1
2
1
Time in seconds (s)
10
6 1
4
2
1
1 1
6
4 1
2 1
0.1
1
6
4
1
2
1
0.01
2 4 6 8 100 2 4 6 8 1000 2 4 6 10000
Current in amps (a)
1
Technical data 1
Catalogue
I²t (Amps² seconds)
1
numbers with Fuse link Current Voltage Minimum *I1 120 kA at Watts Net weight
metal gripping lugs size (amps) (V a.c.) Pre-arcing 690 V a.c. loss (W) per fuse (kg)
250NHG3B-690 3 250 690 160,000 715,000 21 1.050
1
315NHG3B-690 315 375,000 1,400,000 22
1
355NHG3B-690 355 400,000 1,650,000 25
400NHG3B-690 400 475,000 1,600,000 37 1
425NHG3B-690 425 630,000 1,700,000 35
500NHG3B-690 500 856,000 2,480,000 43 1
* I1 is the maximum breaking capacity test at voltage according to IEC 60269-1 and 2 requirements
1
1
1
1
1
1
1
1
Data sheet 720109
Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com 55
NH Fuse links - 690 V a.c. - class gG/gL
1.5 Time-current characteristics and technical data
1.5 690 V a.c. - class gG/gL - 630 and 800 amps - size 4*
1 Time-current characteristics
10000
1 6
4
1 2
1 1000
6
1 4
1 2 800A
630A
1 100
6
1 4
2
1
Time in seconds (s)
10
1 6
4
1 2
1 1
6
1 4
1 2
0.1
1 6
1 4
2
1
0.01
2 4 6 8 1000 2 4 6 8 10000 2 4 6 100000
1 Current in amps (a)
1 Technical data
1 Catalogue
numbers with Fuse link Current Voltage
I²t (Amps² seconds)
Minimum *I1 120 kA at Watts Net weight
metal gripping lugs size (amps) (V a.c.) Pre-arcing 690 V a.c. loss (W) per fuse (kg)
1 630NHG4B-690 4 630 690 1,730,000 6,550,000 44 2.500
800NHG4B-690 800 3,330,000 11,000,000 61
1
*Single indication fuse link with slotted end tags
1 ** I1 is the maximum breaking capacity test at voltage according to IEC 60269-1 and 2 requirements
Please consult us should you wish to order 500 Volts size 4 buletechnical@eaton.com or 00 44 (0) 1509 882 699
1
1
1
1
1
1
1
1
1
Data sheet 720109
56 Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com
NH Fuse links - 500 and 690 V a.c. - class aM
Overview
1.6
Description Catalogue Numbers Class of operation Technical data 1.6
A range of class aM square structure • aM. • Sizes 000 to 3
bodied industrial fuse links • 500 Volts: (amp)NHM(size)B Standards / approvals • Voltage: 500 and 690 V a.c. 1
for a wide variety of motor • Current: 6 to 500 A
protection applications. 690 Volts: (amp)NHM(size)
•
B-690.
• IEC 60269-1 and 2, DIN
43620 Part 1 and 3.
• Rated breaking capacity: 1
120 kA
• Operating frequency: 1
45-62Hz.
1
Optional microswitch
1
NH Fuse body Suitable
size microswitch
1
Size 000 170H0236
Size 00 170H0236 1
Size 1 170H0236
SIze 2 170H0235 or 170H0236
1
Size 3 170H0235 1
1
Compatible fuse holders
Description Type 1
Fuse bases 1-pole SD(size)-D DIN-Rail mounted
SD(size)-S: Screw mounting
1
Fuse bases 3-pole TD(size)-D, DIN-Rail mounted 1
Fuse bases accessories: IP20, shroud and phase barrier kits
Fuse rails vertical: EBF series 1
Fuse switch disconnectors vertical: EBV series
1
horizontal: EBH series
1
1
1
Environmental Packaging Features:
• Recyclable • All fuse links are packed in • Reliable dual indicator 1
• RoHS compliant threes. system (except size 2, 315
• Lead and cadmium free. and 355 A which are single 1
indication)
• Low watts loss 1
• Metal gripping lugs.
1
1
1
1
1
1
1
1
1
1
1
Data sheet 10165
Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com 57
NH Fuse links - 500 and 690 V a.c. - class aM
1.6 Catalogue numbers
58 Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com
NH Fuse links - 500 and 690 V a.c. - class aM
Time-current characteristics and technical data
1.6
500 and 690 V a.c. - class aM - 6 to 50 amps - size 000 1.6
Time-current characteristics 1
1000
6 1
4
1
2
1
100
6
50A 1
40A
4 1
35A
2
1
32A
1
Time in seconds (s)
10
25A
6
4 20A 1
16A
2 1
10A
1
6A
1
6
4 1
2 1
0.1 1
6
4
1
2
1
0.01
1
2 4 6 8 100 2 4 6 8 1000 2 4 6 10000
Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com 59
NH Fuse links - 500 and 690 V a.c. - class aM
1.6 Time-current characteristics and technical data
1 4
1 2
100
1
6
1 4
1 2
1 10
Time in seconds (s)
6
1 4
1 2
100A
80A
1 1 63A
6
1 4
1 2
1 0.1
1 6
4
1 2
1 0.01
2 4 6 8 100 2 4 6 8 1000 2 4 6 10000
1 Current in amps (a)
1 Technical data
1 500 V a.c. 690 V a.c. I²t (Amps² seconds)
Catalogue
1 Catalogue numbers with
numbers with metal metal gripping Fuse link Current Minimum *I1 120 kA at Watts Net weight
gripping lugs lugs size (amps) Pre-arcing 690 V a.c. loss (W) per fuse (kg)
1 63NHM00B 63NHM00B-690 00 63 16,000 52,000 3.1 0.186
80NHM00B 80NHM00B-690 80 24,000 69,500 4.3
1 100NHM00B 100NHM00B-690 100 35,000 110,000 5.5
1 * I1 is the maximum breaking capacity test at voltage according to IEC 60269-1 and 2 requirements
1
1
1
1
1
1
1
1
Data sheet 10165
60 Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com
NH Fuse links - 500 and 690 V a.c. - class aM
Time-current characteristics and technical data
1.6
500 and 690 V a.c. - class aM - 50 to 160 amps - size 1 1.6
Time-current characteristics 1
1000
6
1
4
1
2
1
100
1
6
4 160A 1
125A
2 1
100A
10
1
Time in seconds (s)
80A
6
4 63A 1
50A
2 1
1 1
6
4 1
2 1
0.1 1
6
4
1
2 1
0.01
10000
1
2 4 6 8 100 2 4 6 8 1000 2 4 6
Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com 61
NH Fuse links - 500 and 690 V a.c. - class aM
1.6 Time-current characteristics and technical data
1.6 500 and 690 V a.c. - class aM - 125 to 355 amps - size 2
1 Time-current characteristics
1000
1 6
1 4
2
1
100
1
6
1 4
355A
1 2 315A
250A
1 10
Time in seconds (s)
6 224A
1 4
200A
1 2 160A
1 1 125A
6
1 4
1 2
1 0.1
6
1 4
1 2
1 0.01
2 4 6 8 1000 2 4 6 8 10000 2 4 6 100000
1 Current in amps (a)
1 Technical data
1 500 V a.c.
Catalogue
690 V a.c.
Catalogue
I²t (Amps² seconds)
1 * Single indication
** I1 is the maximum breaking capacity test at voltage according to IEC 60269-1 and 2 requirements
1
1
1
1
1
1
Data sheet 10165
62 Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com
NH Fuse links - 500 and 690 V a.c. - class aM
Time-current characteristics and technical data
1.6
500 and 690 V a.c. - class aM - 315 to 500 amps - size 3 1.6
Time-current characteristics 1
1000
6
1
4
1
2
1
100
1
6
4 1
2 1
Time in seconds (s)
10
1
6 500A
4
400A
1
2 355A 1
1 315A 1
6
4
1
2 1
0.1 1
6
4
1
2
1
0.01
1
2 4 6 8 1000 2 4 6 8 10000 2 4 6 100000
Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com 63
NH Fuse bases and accessories - SD and TD
1.7 Overview
1
1
1
1
Data sheet 10163
64 Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com
NH Fuse bases and accessories - SD and TD
Technical data and accessories
1.7
Technical data
1.7
SD00-D
TD00-D SD1-D SD2-D SD3-D 1
Fuse Base Catalogue Numbers TD00-DI TD1-D TD2-D TD3-D SD4-S SD4-S1600
Base Glass filled PBT 1
Contacts Silver plated copper
Screw, nuts and washers Zinc clear plated steel 1
≤ 35°C 1 1 1 1 1 1
Derating temperature factors for 40°C 0.95 0.95 0.95 0.95 0.95 0.95 1
maximum current
50°C 0.85 0.85 0.85 0.85 0.85 0.85
Maximum power acceptance 12W 32W 45W 60W 110W 145W
1
Degree of protection with covers fitted IP20 IP20 IP20 IP20 - - 1
Terminal screw M8 M10 M10 M12 M16 M16
Maximum tightening torque terminal screw 10N•m 32N•m 32N•m 32N•m 56N•m 56N•m 1
DIN-Rail
Fixing
Screw 1
With microswitch 16A/250V Fuse operated signal
Operating temperature range -20 to 70°C
1
Storage temperature range -40 to 80°C 1
Solid links catalogue numbers 1
Current Catalogue 1
Size (amps) numbers Pack quantity
NH00 160 SDL-00 3 1
NH1 250 SDL-1 3
NH2 400 SDL-2 3 1
NH3 630 SDL-3 3
Solid link 1
Accessories
1
Fuse extraction handle 1
Current Catalogue
Size (amps) numbers Pack quantity 1
NH00-3 160 - 630 FEH 1
1
1
Fuse extraction handle
Shroud kits 1
Fuse base Fuse Current Catalogue
series size (amps) numbers Description 1
SD1 NH1 250 SD12-SK
SD2 NH2 400 SD12-SK Kit includes 2 shrouds
and 1 fuse cover
1
SD3 NH3 630 SD3-SK
1
Shroud kit 1
1
1
1
1
1
1
1
Data sheet 10163
Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com 65
NH Fuse bases and accessories - SD and TD
1.7 Accessories
1.7 Current
Phase barrier kit
Catalogue Pack
Size (amps) numbers quantity Description
1 NH00 160 SD00-PB 1 2-Phase barriers
NH1 250 SD12-PB 1 2-Phase barriers and
1 NH2 400 SD12-PB 1 2 ganging links
1
Phase barrier Ganging link
1
1 IP protection kits
1
1
1 Size
Current
(amps)
Catalogue
numbers
Fuse
cover Shroud
Phase
barrier
Ganging
link
Integral
kit Description
1 NH00 160 TD00-IP20 3 6 2 Triple pole protection kit for TD00-D with shrouds,
fuse covers and phase barriers
1 Integral triple pole protection kit for TD00-DI with
1 TD00-IP20I molded shrouds and phase barriers
3 1 Integral triple pole protection kit for TD00-DI with
1 TD00-IP20IC fuse covers and molded shrouds and phase barriers
NH1 250 TD1-IP20 3 6 2 2 Triple pole protection kit with terminal shrouds, fuse
1 NH2 400 TD2-IP20
cover phase barriers and ganging links
1
1
1
1
Microswitch
1 Catalogue
Numbers Pack Quantity Ratings
1 BVL50 1 5 A 250 V a.c.
170H0235 12 2 A 250 V a.c.
1 170H0236 12 2 A 250 V a.c.
170H0238 12 2 A 250 V a.c.
1
1 NH Fuse body size - Suitable microswitch
Size 000 Size 00 Size 0 Size 01 Size 1 Size 02 Size 2 Size 03 Size 3 Size 4
1 170H0236 170H0236 170H0236 170H0235 170H0236 BVL50 170H0235 BVL50 170H0235 Not available
170H0236
1
Note: Microswitches fit onto the fuse gripping lugs and are applicable to all NH size Eaton’s Bussmann series fuse links (except size 4)
1
Data sheet 10163
66 Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com
NH Fuse bases and accessories - SD and TD
Dimensions - mm
1.7
Dimensions (mm) 1-pole, size 00
B
1.7
E
1
H
1
1
G 1
F
1
1
A 1
I
1
1
1
C D
1
1
1
J
Size Pole A B C D E F G H I J
1
NH00 1-pole 120 102 35.5 20 56 24 51 M8x20 25 8
1
Dimensions (mm) 1-pole,
p sizes 1, 2 and 3
B 1
E 1
H 1
1
G
1
F 1
1
A
1
1
1
C D
1
1
K J
1
Size Poles/Type A B C D E F G H I J K 1
NH1 1-pole 199 175 56 35 79 37 78 M10x25 25 10 30
1 pole 224 199 56 35 79 37.5 86 M10x25 25 10 30
1
NH2
1-pole double clip 223 199 56 35 82 37 79 M10x25 25 10 30
NH3 1-pole 239 209 56 36 82 37.5 88 M12x30 25 10 30
1
1
Data sheet 10163
Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com 67
NH Fuse bases and accessories - SD and TD
1.7 Dimensions
1 H
1 G
1 M
F
1
1 A
ØJ
1
1 C D
1
1 I K
1 Size Poles/Type A B C D E F G H I J K L M N
1-pole 1250A 295 255 90 52 105 47 122 M16x40 30 14 40 150 92 M12x40
NH4
1 1-pole 1600A 295 255 90 60 105 50 125 M16x40 30 14 40 150 92 M12x40
1
E
1
1
P H
1
1 G
1 F
1 B
1 A
1
1
1
M
1 D
L
1
M
1
C
1
1
I J
1
Size Poles/Type A B C D E F G H I J K L M N P
1 NH00 3-pole 120 102 35.5 20 56 24 51 M8x20 25 8 - 103.5 34 146 89
1
Data sheet 10163
68 Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com
NH Fuse bases and accessories - SD and TD
Dimensions - mm
1.7
Dimensions (mm) integral 3-pole, size 00
1.7
1
1
1
1
1
1
1
1
1
1
1
1
1
Size Poles/Type A B C D E F G H I J K L M N P
NH00 3-pole Integral 120 102 - 20 56 24 51 M8x20 - 7.5x10 63.5 97 32.3 146 90 1
Dimensions (mm) 3-pole,
p sizes 1, 2 and 3 1
1
1
1
1
1
1
1
1
1
1
1
1
1
Size Poles/Type A B C D E F G H I J K L M N P
NH1 3-pole 199 175 56 35 79 37 78 M10x25 25 10 30 188 66 245 125.5 1
3-pole 224 199 56 35 79 37.5 86 M10x25 25 10 30 188 66 245 125.5
NH2
3-pole double clip 223 199 56 35 82 37 79 M10x25 25 10 30 188 66 245 125.5 1
NH3 3-pole 239 209 56 36 82 37.5 88 M12x30 25 10 30 221 82.5 260 137.5
1
1
Data sheet 10163
Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com 69
NH Fuse rails - vertical - EBF
1.8 Overview
70 Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com
NH Fuse rails - vertical - EBF
Technical data and dimensions
1.8
Technical data
1.8
Type EBF 00 100 mm EBF 00 185 mm EBF 2 EBF3
Size 00 00 2 3 1
Rated thermal current Ith = In A 160 160 400 630
Voltage Un V 690 690 690 690 1
Rated insulation voltage UI V 1000 1000 1000 1000
Rated frequency Hz 50 - 60 50 - 60 50 - 60 50 - 60
1
Rated power dissipation W 12 12 45 60
Rated short-circuit withstand current kA 100 100 100 100
1
Mechanical durability Number of cycles 100 100 100 100 1
Weight kg 0.75 2 4.5 5
IP Degree of protection IP 00 00 201 201 1
Size of fuse links 00 00 2 3
1 With fuse links shrouds 1
Dimensions (mm) - EBF 00 100 mm busbar system
112,5
1
49,8 49,8
1
8,5x16
8,5x16
1
50
50
1
100
100
1
ø8,5
ø8,5
ø
ø
1
1
423
100
100
1
1
84.5
113,5
1
172,5
1
39,5
39,5 39,5 1
38
24 40.6 1
M8 screws V- terminals M8 screws V- terminals
1
side view side view
1
1
1
1
1
1
1
1
1
1
1
Data sheet 10240
Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com 71
NH Fuse rails - vertical - EBF
1.8 Dimensions - mm
94,5
1
94,5
8,5x1
56,5
8,5x1
1
1
1
185
1
185
8,5
1
8,5
1
705
705
185
1
185
1
1
1
1
97
97
1 15,5 15,5
1
3
39,5
39,5
1
1
40
40
1 44 45
44 45
1
1 49
141,5
49
141,5
M8 screws V-terminals
1
1
1
1
1
1
1
1
1
Data sheet 10240
72 Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com
NH Fuse rails - vertical - EBF
Dimensions - mm
1.8
Dimensions (mm) - EBF 2 and 3
150 150 1.8
99 113
113
1
83
111 111
1
1
92
1
1
1
1
185
1
ø 8,5
ø 14
1
1
1
664
1
185
185
1
1
305
30
305
1
1
1
L3 1
76,5
40
L3
1
150
112
L2
L1
L1
L2
1
52
99 18,5 53,5 52
5
67 1
150
EBF 2 and 3 150 99
178 1
EBF 2 and 3 With terminals 2V (2 x 240 mm2)
1
1
1
1
1
1
1
1
1
1
Data sheet 10240
Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com 73
NH Fuse switch disconnectors - vertical - EBV
1.8 Overview
1
1
1
1
1
1
1
1
1
1
1
Data sheet 10275
74 Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com
NH Fuse switch disconnectors - vertical - EBV
Catalogue numbers
1.8
Catalogue numbers
1.8
Compatible
Size
Current Busbar
(amps) system
Catalogue
numbers Cable terminals
Pack
quantity weight
fuse links
size 1
Vertical fuse switch disconnector for NH Size 00 for 100 mm busbar system - simultaneous 3 phase switching
Bridge terminals with bridge clamps (s) 4-70mm², screw terminals with
1
00 160 100 EBV0023TS8 1 1.3 kg 00
M8 screws
EBV00023TV1 V-terminals with V-clamps 25-120SW 1.5 kg 1
EBV0023TV0 V-terminals, without V-clamps 1.3 kg
Vertical fuse switch disconnector for NH Size 00 for 185 mm busbar system - each phase switching separately
1
00 160 185 EBV0033SS8 Bridge terminals with bridge clamps (s) 4-70 mm², screw terminals with
M8 screws 1 2.8 kg 00 1
EBV0033SV1 V-terminals with V-clamps 25-120SW 2.9 kg
EBV0033SV0 V-terminals, without V-clamps 2.8 kg
1
Vertical fuse switch disconnector for NH Size 00 for 185 mm busbar system - simultaneous 3 phase switching 1
Bridge terminals with bridge clamps (s) 4-70 mm2, screw terminals with
00 160 185 EBV0033TS8 1 2.7 kg 00
M8 screws
EBV0033TV1 V-terminals with V-clamps 25-120SW 2.8 kg
1
EBV0033TV0 V-terminals without V-clamps 2.7 kg 1
Vertical fuse switch disconnector for NH Sizes 1 and 2 for 185 mm busbar system - each phase switching separately
2 400 185 EBV233SV1 V-terminals with V-clamps 240 mm2 1 5.8 kg 1 and 2 1
EBV233SM1 Screw terminals with pressed nuts M10 5.7 kg
EBV233SW1 2V-terminals with double clamps 240 mm2 6.4 kg 1
EBV233SV0 V-terminals without V-clamps 5.5 kg
EBV233SW0 2V-terminals without double V-clamps 6.9 kg 1
Vertical fuse rail suitable for NH Sizes 1 and 2 fuses for 185mm busbar system - simultaneous 3 phase switching
2 400 185 EBV233TV1 V-terminals with V-clamps 240 mm2 1 5.8 kg 1 and 2
1
EBV233TM1 Screw terminals with pressed nuts M10 5.7 kg 1
EBV233TW1 2V-terminals with double V-clamps 240 mm2 6.4 kg
EBV233TV0 V-terminals without V-clamps 5.5 kg 1
EBV233TW0 2V-terminals without double V-clamps 6.9 kg
Vertical fuse rail suitable for NH size 3 fuses for 185mm busbar system - each phase switching separately 1
3 630 185 EBV333SV1 V-terminals with V-clamps 240 mm2 1 6.6 kg 3
EBV333SM2 Screw terminals with pressed nuts M12 6.5 kg 1
EBV333SW1 2V-terminals with double V-clamps 240mm2 7.2 kg
EBV333SV0 V-terminals without V-clamps 6.3 kg
1
EBV333SW0 2V-terminals without double V-clamps 6.7 kg 1
Vertical fuse rail suitable for NH size 3 fuses for 185 mm busbar system - simultaneous 3 phase switching
3 630 185 EBV333TV1 V-terminals with V-clamps 240 mm2 1 6.6 kg 3 1
EBV333TM2 Screw terminals with pressed nuts M12 6.5 kg
EBV333TW1 2V-terminals with double V-clamps 240 mm2 7.2 kg 1
EBV333TV0 V-terminals without V-clamps 6.3 kg
EBV333TW0 2V-terminals without double V-clamps 6.7 kg 1
1
1
1
1
1
1
1
1
1
1
Data sheet 10275
Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com 75
NH Fuse switch disconnectors - vertical - EBV
1.8 Technical and dimensions - mm
Technical data
1.8
Type EBV 00/ 100 mm EBV 00 EBV 2 EBV 3
1 Rated thermal current with fuse links Ith = In A 160 160 400 630
Rated thermal current with solid links Ith A N/A N/A 600 750
1 Voltage Un V 690 690 690 690
Utilisation category 690 V a.c. AC-22B AC-22B AC-22B AC-21B
1 500 V a.c. N/A N/A N/A AC-22B
AC-23B AC-23B AC-23B AC-23B
1 Rated switching current Ie
400 V a.c.
A 160 160 400 630
1 Rated short-circuit making current 690 V a.c. 25 80 100 80
500 V a.c. 25 N/A 100 100
1 400 V a.c. 25 100 100 100
Rated short-circuit withstand current 690 V a.c. 100 80 100 80
1 500 V a.c. 100 N/A 100 100
400 V a.c. 100 100 100 100
1 Rated insulation voltage Ui V 1000 1000 1000 1000
Rated impulse withstand voltage Uimp kV 8 12 12 12
1 Rated short time withstand current Icw kA N/A N/A 12 2)/ 15 3) 142)/ 16 3)
1 Rated frequency Hz 50/60 50/60 50/60 50/60
Mechanical durability No. of cycles 1600 1600 1000 1000
1 Electrical durability 200 200 200 200
IP Rating IP 30 20 30 30
1 Fuse links size 00 00 1, 2 3
1 1: fuse link gTr 630 kVA, DIN 43620, VDE 0636/2011 voltage
2 For disconnectors 1-phase disconnected
1
94,5
8,5 x 16
50 8,5 x 16
1
1
185
100
1
8,5
8,5
1
1
705
100
423
185
1
297,5
416
1 84,5
97,5
113,5
1 172,5
40 39,5
1 39,5
38
1
14,5
1 16 5
24 39,6 44 45
1 M8 screws
10 5
M10 screws
1
1
1
Data sheet 10275
76 Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com
NH Fuse switch disconnectors - vertical - EBV
Dimensions - mm
1.8
Dimensions (mm) - EBV 00 (Three phase switching simultaneously)
1.8
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Dimensions (mm) - EBV 2 (Each phase switching separately) 1
1
1
1
1
1
1
1
1
1
1
1
1
1
V-terminals
1
M12 screws
1
Data sheet 10275
Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com 77
NH Fuse switch disconnectors - vertical - EBV
1.8 Dimensions - mm
135
170
1 135
1
92 92
92 92
1
1
185 185
1 185,0000 185
14
1 14
1 665
665
1 185,0000 185
185 185
1 305 316.5
1
1
1
40
1 35
1 52
99
18,5 53.5
150
52
99
18,5 53.5
150
1
Data sheet 10275
78 Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com
NH Fuse switch disconnectors - vertical - EBV
Dimensions - mm
1.8
Dimensions (mm) - EBV 3 (Three phase)
175
1.8
135
175
1
135
92 92
1
92 92
1
1
1
185 185
1
185 185 1
1
14 14
1
1
665
665 1
185
1
185
185 185
1
316.5
305
1
1
1
1
1
35
35
1
1
52 18,5 53.5 18,5 53.5
52
1
99 150 150
99
Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com 79
NH Fuse switch disconnectors - horizontal - EBH000
1.8 Overview
80 Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com
NH Fuse switch disconnectors - horizontal - EBH000
Catalogue numbers and technical data
1.8
Catalogue numbers
1.8
Compatible
Size
Current
(amps)
Busbar Catalogue
system numbers Cable terminals
Pack
quantity
fuse links
size 1
Horizontal fuse switch disconnector for NH size 000 up to 160 A for installation on mounting plates
000 160 N/A EBH000O3TS5 for connection of round conductors - S-bridge clamps 1 000 up to 160 A
1
for connection of round conductors - S-bridge clamps, option to install on
EBH000O3TS5-D DIN rail 1
EBH000O3TM8 for connection of round conductors with lug terminals - M8 screws
for connection of round conductors with lug terminals - M8 screws, option
1
EBH000O3TM8-D to install on DIN rail
for connection of round conductors - S-bridge clamps, lengthened terminal 1
EBH000O3TS5L shrouds
EBH000O3TM8L for connection of round conductors with lug terminals - M8 screws, 1
lengthened terminal shrouds
Horizontal fuse switch disconnector for NH size 000 up to 160 A for installation on 60 mm busbar 1
Cable terminal – bottom, for connection of round conductors - S-bridge
000 160 60 mm EBH00013TBS5 000 up to 160 A
clamps 1
EBH00013TTS5 Cable terminal – top, for connection of round conductors - S-bridge clamps
EBH00013TBM8 Cable terminal – bottom, for connection of conductors with lug terminals - 1 1
M8 screws
EBH00013TTM8 Cable terminal – top, for connection of conductors with lug terminals - M8
screws
1
1
Technical data 1
Rated thermal current with solid links Ith
EBH 000
100/160
1
A
Voltage Un V 690 1
Utilisation category AC-23B AC-22B AC-21B DC-21B
Rated switching current Ie A 100 100 100 160 1
Rated switching Voltage Ue V 400 400 690 250
Rated short circuit making current 690 V 100 100 100 100 1
Rated short-circuit withstand current 690 V 25 25 25 25
Rated insulation voltage Ui V 1000 1000 1000 1000 1
Rated power dissipation 12 12 12 12
Rated impulse withstand voltage Uimp
W
8 8 8 8
1
kV
Rated frequency Hz 50-60 50-60 50-60 50-60 1
2000 2000 2000 2000
Mechanical durability Nb of cycles
300 300 300 300
1
Electrical durability Nb of cycles
IP Rating IP20 IP20 IP20 IP20
1
Fuse links size 000 000 000 000
1
1
1
1
1
1
1
1
DIN-Rail Mounting plates Busbar
1
1
1
Data sheet 10292
Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com 81
NH Fuse switch disconnectors - horizontal - EBH000
1.8 Dimensions - mm
1
1 23,3
1
1
1
1
181
111.5
159
1
1
1
1 25 25 5 50
1 89
1 On mounting plates
91,5
1
1
1
1
1
1
1
194
190
1
1
1
1
1 3
25 25 47
1 89
1
1
1 50
1
Data sheet 10292
82 Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com
NH Fuse switch disconnectors - horizontal - EBH000
Dimensions - mm
1.8
Dimensions (mm) - EBH000 (60 mm busbar mounting)
1.8
112
70
1
1
1
1
60,05
1
1
1
191
60 1
1
1
1
58
1
1
25 25
89
grubo szyny 3-10mm
1
Bottom cable terminal 1
112
1
70
1
1
1
60
1
1
1
191 1
60
1
1
1
58
1
1
25 25 1
grubosc
´ ´ szyny 3-10 mm
89
1
Top cable terminal
1
1
Data sheet 10292
Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com 83
NH Fuse switch disconnectors - horizontal - EBH00 to EBH4
1.8 Overview
1
1
1
1
1
1
1
1
1
1
1
Data sheet 10293
84 Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com
NH Fuse switch disconnectors - horizontal - EBH00 to EBH4
Catalogue numbers
1.8
Catalogue numbers
1.8
Compatible
Size
Current
(amps)
Busbar
system
Catalogue
numbers Cable terminals
Pack
quantity
fuse links
size 1
Horizontal fuse switch disconnector for NH size 00 for installation on mounting plates
00 160 N/A EBH00O3TS5 For connection of round conductors 1 00
1
EBH00O3TM8 For connection of conductors with lug terminals
1
EBH00O3TV1 For connection of sector-shaped conductors
EBH00O3TS5L For connection of round conductors, lenghtened terminal shrouds 1
EBH00O3TM8L For connection of conductors with lug terminals, lenghtened terminal shrouds
EBHOO03TV1L For connection of sector-shaped conductors, lengthened terminal shrouds 1
Horizontal fuse switch disconnector for NH size 00 for installation on 60 mm busbar
00 160 60 mm EBH0013TBM8 Cable terminal - bottom, for connection of conductors with lug terminals 1 00 1
EBH0013TTM8 Cable terminal - top, for connection of conductors with lug terminals
EBH0013TBF Cable terminal - top, for connection of conductors with bare ends
1
EBH0013TTF Cable terminal - bottom, for connection of conductors with bare ends frame
clamps 1
Horizontal fuse switch disconnector for NH size 1 for installation on mounting plates
1 250 N/A EBH1O3TS8 For connection of round conductors - S-bridge clamps 1 1
1
EBH1O3TM1 For connection of conductors with lug terminals - screws 1
EBH1O3TV1 For connection of sector-shaped conductors V-clamps
EBH1O3TVS
For connection of round conductors, top terminals, V-terminals, bottom
terminals, S-bridge terminals
1
EBH1O3TVM
For connection of round conductors, top terminals, V-terminals, bottom
terminals, screw terminals
1
For connection of round conductors, top terminals, S-bridge terminals, bottom
EBH1O3TSV terminals, V-terminals 1
For connection of round conductors, top terminal, screw terminals, bottom
EBH1O3TMV terminals, V-terminals 1
Horizontal fuse switch disconnector for NH size 1 for installation on 60 mm busbar
1 250 60 mm EBH113TTS8 Top cable terminals, for connection of round conductors, S-bridge clamps 1 1
1
EBH113TBS8 Bottom cable terminals, for connection of round conductors, S-bridge clamps
EBH113TBM1 Bottom cable terminals, for connection of conductors with lug terminals - screws
1
EBH113TTV1 Top cable terminals, for connection of sector-shaped conductors - V-clamps 1
EBH113TBV1 Bottom cable terminals for connection of sector-shaped conductors - V-clamps
Horizontal fuse switch disconnector for NH size 1 for installation on 100 mm busbar 1
1 250 100 mm EBH123TTS8 Top cable terminals, for connection of round conductors 1 1
EBH123TBS8 Bottom cable terminals, for connection of round conductors - S-bridge clamps 1
EBH123TTM1 Top cable terminals, for connection of conductors, with lug terminals - screws
EBH123TBM1 Bottom cable terminals, for connection of conductors, with lug terminals - screws
1
EBH123TTV1 Top cable terminals, for connection of sector shaped conductors - V-clamps
EBH123TBV1 Bottom cable terminals for connection
1
Horizontal fuse switch disconnector for NH size 2 for installation on mounting plates 1
2 400 N/A EBH2O3TS8 For connection of round conductors - S-bridge clamps 1 2
EBH2O3TM1 For connection of conductors with lug terminals - M10 screws 1
EBH2O3TV1 For connection of sector-shaped conductors - V-clamps
EBH2O3TW1 For connection of sector-shaped conductors - double V-clamps 1
Horizontal fuse switch disconnect for NH size 2 for installation on 60 mm busbar
Bottom cable terminals, for connection of conductors with lug terminals, M10
1
2 400 60 EBH213TBM1 screws 1 2
Top cable terminals, for connection of conductors with lug terminals, M10 1
EBH213TTM1 screws
EBH213TBV1 Bottom cable terminals, for connection of sector-shaped conductors, V-clamps 1
EBH213TTV1 Top cable terminals, for connection of sector shaped conductors, V-clamps
Bottom cable terminals, for connection of sector shaped conductors, double 1
EBH213TBW1 V-clamps
EBH213TTW1 Top cable terminals, for connection of sector shaped conductors, double 1
V-clamps
1. Please contact Eaton’s Bussmann series application engineers to discuss specific requirements.
1
1
1
Data sheet 10293
Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com 85
NH Fuse switch disconnectors - horizontal - EBH00 to EBH4
1.8 Catalogue numbers and technical data
Catalogue numbers
1.8
Compatible
1 Size
Current
(amps)
Busbar
system
Catalogue
numbers Cable terminals
Pack
quantity
fuse links
size
Horizontal fuse switch disconnector for NH size 2 for installation on 100 mm busbar
1 Bottom cable terminals, for connection of conductors with lug terminals, M10
2 400 100 mm EBH223TBM1 1 2
screws
1 EBH223TTM1 Top cable terminals, for connection of conductors with lug terminals, M10
screws
1 EBH223TBV1 Bottom cable terminals, for connection of sector shaped conductors , V-clamps
EBH223TTV1 Top cable terminals, for connection of sector shaped conductors, V-clamps
1 Bottom cable terminals, for connection of sector shaped conductors, double
EBH223TBW1 V-clamps
1 EBH223TTW1 Top cable terminals, for connection of sector shaped conductors, double
V-clamps
1 Horizontal fuse switch disconnector for NH size 3 for installation on mounting plates
3 630 N/A EBH3O3TS8 For connection of round conductors, S-bridge clamps 1 3
1 EBH3O3TM2 For connection of conductors with lug terminals, M12 screws
Horizontal fuse switch disconnector for NH size 3 for installation on 60 mm busbar
1 For installation on to 60 mm busbar system, top/bottom cable terminals, M12
3 630 60 mm EBH313TM2 screws 1 3
1 Horizontal fuse switch disconnector for NH size 4 for installation on mounting plates
4a 1250 N/A EBH403TM2-12 Three phase switching simultaneously 1 4
1 1600 EBH403TM2-16 Three phase switching simultaneously
1250 EBH403SM2-12 Each phase switching simultaneously
1 1600 EBH403SM2-16 Each phase switching simultaneously
1
Technical data - sizes 00, 1 and 2
1
EBH 00 EBH 1 EBH 2
1 Rated thermal current with solid links Ith A 160 250 400
Voltage Un V 690 690 690
1 Utilisation category AC-23B DC-21B DC-22B AC-23B AC-22B DC-22B AC-23B DC-21B DC-22B
Rated switching current Ie A 160 160 160 250 250 250 400 400 400
1 Rated switching Voltage Ue V 690 440 250 400 690 250 690 440 220
Rated short circuit making current 690 V 80 20 20 80 80 25 80 15 20
1 100 20 20 100 100 25 100 15 20
400 V
1 Rated short-circuit withstand current 690 V 80 20 20 80 80 25 80
400 V 100 20 20 100 100 25 100
1 Rated insulation voltage Ui V 1000 1000 1000
Rated power dissipation W 12 32 45
1 Rated impulse withstand voltage Uimp kV 8 8 12
Rated frequency Hz 50-60 N/A N/A 50-60 50-60 N/A 50-60 N/A N/A
1 1600 1600 1000
Mechanical durability No of cycles
1 Electrical durability 200 200 200
IP Rating IP 20 30 20
1 Weight kg 0.7, 0.9 2.5 3 / 4.5
Fuse links size 00 1 2
1
1
1
1
1
1
1
1
Data sheet 10293
86 Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com
NH Fuse switch disconnectors - horizontal - EBH00 to EBH4
Technical data and dimensions - mm
1.8
Technical data - sizes 3 and 4a
1.8
EBH 3 EBH4a
Rated thermal current with solid links Ith A 630 1250 1600 1
Voltage Un V 690 500 400
Utilisation category AC-22B DC-21B AC-22B AC-21B 1
Rated switching current Ie A 630 630 1250 1600
Rated switching Voltage Ue V 690 250 500 400 1
Rated short circuit making current 690 V 100 100
100 100
1
400 V
Rated short-circuit withstand current 690 V 25 1
400 V 25 50
Rated insulation voltage Ui V 1000 800 1
Rated power dissipation W 60
Rated impulse withstand voltage Uimp kV 12 8 1
Rated frequency Hz 50-60 N/A 50-60
1000 1
Mechanical durability No of cycles
Electrical durability 200 1
IP Rating IP 20
Weight kg 5 / 5.9 1
Fuse links size 3 4a
1
Dimensions (mm) for EBH00 suitable for installation on mounting plates 1
1
1
1
1
1
1
1
1
1
1
1
Dimensions and spacing holes for installation on mounting plates 1
5 70
1
R
R
1
7
1
66 3 1
1
1
1
1
Data sheet 10293
Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com 87
NH Fuse switch disconnectors - horizontal - EBH00 to EBH4
1.8 Dimensions - mm
1 27
1 4
1
1
1
1 269
243 240 176
1
R7.5
1
1
1
1 57
180
57 41
65 3
1 Screw terminals
111
1
1 41
4
1
1
1
1 269
1 243 240
1 R7.5
1
1
1
57 57 65 3
1 180
1 V Clamps
1 6 94
11
1
50
8 100
1
1
1
1
Data sheet 10293
88 Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com
NH Fuse switch disconnectors - horizontal - EBH00 to EBH4
Dimensions - mm
1.8
Dimensions (mm) for EBH1 suitable for installation on 60 mm busbar
165
1.8
140 1
94
4 1
1
1
1
1
269
243
R7.5
1
1
1
1
3
57 57 70 1
180
1
1
Dimensions (mm) for EBH1 suitable for installation on 100 mm busbar
1
165
140
1
94 1
4
1
1
1
1
1
269
243
1
R7.5
1
1
1
3 1
57 57 70
1
1
1
1
1
Data sheet 10293
Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com 89
NH Fuse switch disconnectors - horizontal - EBH00 to EBH4
1.8 Dimensions - mm
1 80
1 31
1
1
1
ø 7.5
1 298
266
260
216
1
1
1
1
1 65 65
208
1
Screw Terminals
1 130
1
1
1
1
ø 7.5
1
325 321
1
1
1
1
1
1 65 65
208
1 V Terminals
1 6 94
1
11
1
50
8 100
1
1
1
Data sheet 10293
90 Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com
NH Fuse switch disconnectors - horizontal - EBH00 to EBH4
Dimensions - mm
1.8
Dimensions (mm) for EBH2 suitable for installation on 60 mm busbar
154
1.8
1
1
1
1
ø 7.5
1
298 1
266260
1
1
1
1
1
65 65 109.0954 1
208
1
1
Dimensions (mm) for EBH2 suitable for installation on 100 mm busbar
1
154 1
1
1
1
1
ø 7.5
1
298
266 260 1
1
1
1
1
1
65 65
208
109.1000 1
1
1
1
1
Data sheet 10293
Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com 91
NH Fuse switch disconnectors - horizontal - EBH00 to EBH4
1.8 Dimensions - mm
92 Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com
Index - by catalogue numbers
Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com 93
Index - by size
Index - by size
Size Voltage Catalogue number Class Type Page
1 0 500 NHG0B gG/gL NH Fuse - Metal 41
00 400 NHFF00BI-400 gFF NH Fuse - IMGL 24
1 00
00
400
400
NHG00B-400
NHG00BI-400
gG/gL
gG/gL
NH Fuse - IMGL
NH Fuse - IMGL
32
32
00 500 NHG00B gG/gL NH Fuse - Metal 40
1 00 500 NHG00BI gG/gL NH Fuse - IMGL 40
00 500 NHM00B aM NH Fuse - Metal 60
1 00
00
690
690
NHG00B-690
NHG00BI-690
gG/gL
gG/gL
NH Fuse - Metal
NH Fuse - Metal
52
52
00 690 NHM00B-690 aM NH Fuse - Metal 60
1 00 to 3 690 EBF N/A NH Fuse rails - vertical 70-73
00 to 4 400, 500, 690 EBH00 to 4 N/A NH Fuse disconnector - horizontal 84-91
1 000
000
400
400
NHFF000BI-400
NHG000B-400
gFF
gG/gL
NH Fuse - IMGL
NH Fuse - Metal
23
31
000 400 NHG000BI-400 gG/gL NH Fuse - IMGL 31
1 000 500 NHG000B gG/gL NH Fuse - Metal 39
000 500 NHG000BI gG/gL NH Fuse - IMGL 39
1 000
000
500
690
NHM000B
EBH000
aM
N/A
NH Fuse - Metal
NH Fuse disconnector - horizontal
59
80-83
000 690 NHG000B-690 gG/gL NH Fuse - Metal 51
1 000 690 NHG000BI-690 gG/gL NH Fuse - Metal 51
000 690 NHM000B-690 aM NH Fuse - Metal 59
1 01
01
400
400
NHG01B-400
NHG01BI-400
gG/gL
gG/gL
NH Fuse - Metal
NH Fuse - IMGL
33
33
01 500 NHG01B gG/gL NH Fuse - Metal 42
1 01 500 NHG01BI gG/gL NH Fuse - IMGL 42
02 400 NHFF02BI-400 gFF NH Fuse - IMGL 26
1 02
02
400
400
NHG02B-400
NHG02BI-400
gG/gL
gG/gL
NH Fuse - Metal
NH Fuse - IMGL
34
34
02 500 NHG02B gG/gL NH Fuse - Metal 44
1 02 500 NHG02BI gG/gL NH Fuse - IMGL 44
03 400 NHG03B-400 gG/gL NH Fuse - Metal 35
1 03
03
400
500
NHG03BI-400
NHG03B
gG/gL
gG/gL
NH Fuse - IMGL
NH Fuse - Metal
35
46
03 500 NHG03BI gG/gL NH Fuse - IMGL 46
1 1 400 NHFF1BI-400 gFF NH Fuse - IMGL 25
1 400 NHG1B-400 gG/gL NH Fuse - Metal 33
1 1
1
400
500
NHG1BI-400
NHG1B
gG/gL
gG/gL
NH Fuse - IMGL
NH Fuse - Metal
33
43
1 500 NHG1BI gG/gL NH Fuse - IMGL 43
1 1 500 NHM1B aM NH Fuse - Metal 61
1 690 NHG1B-690 gG/gL NH Fuse - Metal 53
1 1
1
690
690
NHG1BI-690
NHM1B-690
gG/gL
aM
NH Fuse - IMGL
NH Fuse - Metal
53
61
1-pole 690 SD-D N/A NH Base 64
1 1-pole 690 SD-S N/A NH Base 64
2 400 NHFF2BI-400 gFF NH Fuse - IMGL 27
1 2
2
400
400
NHG2B-400
NHG2BI-400
gG/gL
gG/gL
NH Fuse - Metal
NH Fuse - IMGL
34
34
2 500 NHG2B gG/gL NH Fuse - Metal 45
1 2 500 NHG2BI gG/gL NH Fuse - IMGL 45
2 500 NHM2B aM NH Fuse - Metal 62
1 2
2
690
690
NHG2B-690
NHG2BI-690
gG/gL
gG/gL
NH Fuse - Metal
NH Fuse - IMGL
54
54
2 690 NHM2B-690 aM NH Fuse - Metal 62
1 3 400 NHFF3BI-400 gFF NH Fuse - IMGL 28
3 400 NHG3B-400 gG/gL NH Fuse - Metal 35
1 3
3
400
500
NHG3BI-400
NHG3B
gG/gL
gG/gL
NH Fuse - IMGL
NH Fuse - Metal
35
47
3 500 NHM3B aM NH Fuse - Metal 63
1 3 690 NHG3B-690 gG/gL NH Fuse - Metal 55
3 690 NHM3B-690 aM NH Fuse - Metal 63
1 3-pole
4
690
500
TD-D
NHG4G
N/A
gG/gL
NH Base
NH Fuse - Metal
64
48
4 690 NHG4B-690 gG/gL NH Fuse - Metal 56
1 N/A 250 170H0235 N/A Microswitch 66
N/A 250 170H0236 N/A Microswitch 66
1 N/A
N/A
250
250
170H0238
BVL50
N/A
N/A
Microswitch
Microswitch
66
66
N/A 690 EBV N/A NH Fuse disconnector - vertical 74-79
1 N/A N/A FEH N/A Fuse extraction handle 65
N/A N/A SDL N/A Solid link 65
1 N/A N/A SD-PB N/A Phase barrier kit 66
N/A N/A SD-SK N/A Shroud kit 65
N/A N/A TD-IP20 N/A IP20 Protection kit 66
1
1
94 Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com
Contact details
Bussmann series NH Fuse links, bases and gear catalogue CA132063EN - October 2017 www.eaton.com 95
At Eaton, we’re energized by the challenge of powering a world
that demands more. With over 100 years experience in electrical
power management, we have the expertise to see beyond today.
From groundbreaking products to turnkey design and engineering
services, critical industries around the globe count on Eaton.
We power businesses with reliable, efficient and safe electrical
power management solutions. Combined with our personal service,
support and bold thinking, we are answering tomorrow’s needs
today. Follow the charge with Eaton. Visit eaton.com/electrical.