Specifications system Function Sample Reagent Probe ‘& Mixer Reaction System Optical System calaQc Others ‘Category Rondomiaccess: uly automatic chemisty analyzer Throughput 150 testsfhour Methodology End point, Fixed Time: Kinetic: Reagent ‘Open System Reagent Position 40 Sample Position 40 Minimum Reaction Volume! 1500L ‘Canyover <0,005% Water Consumption Low tol at/Hour ‘Maximum Reaction Time 18 minutes (Single reagent), 12 minuies(Dual reagent) Maximum Reaction Volume 500.UL Principle ‘Colorimetty, Turbidimetry Testing Mode. Regular mode (singles.dual reagents}; fas! mode|single reagent) ‘Sample Mode Random access, SIAT sample priority ‘Sample Volume! 2-50UL, step by 0.1/UL ‘Sample Disk 40 posiions reer poet (One probe for somple'ard reagent with liquid level detection: vertical ang horizontal colision protection and reagent volume real fime monitoring function Sample Tube Semel ea 12x100 mii 12x75 mm), Vacuum Reagent Volume £87:150°450 UL. R2:10-300UL, step by 1ul Keoger Ose “01683 postions 24ers Molen DSHD 2 Reagent Bolties Compatibie with Olympus and Hitachi reagent bolies Mixer High poised nonomatgriel miner ‘ Reaction Cuvettes 50 cuvetles, semi:permanent rigid UV special plaslc ewveltes Wash Station éstep ago wash station — i Reaction Temperature” 3720.1 Heater Metal thifmostatt forreaction cisk aN Lamp Halogen Tungsten lamp, 12V20W, about 2000hours, water cooling system Filter FMSS(Fiisealed Matrix Spectiomelric System) Wavelength SB Wavelengths: 340/408 430,510,546 578.630.6708 Resolution = TQ) \ap.0o01Abs a_i Linearity Range: 0:3 SAbs ‘Accuracy ‘0.5A:< + O.02Abs. | 0A: <* 0.04Abs E stray Uoht 245 Stability “<0.01Abs/hour aa | cv <15% Half Band Accuracy <22nm ye Detector Photodiode detector onay LL SS "= ie ae ‘Calibration Curve Coltbration curve avto check, auto curve fiting QC Rule Wastgaittmultivule.COmmtive sum check, [win Pior ac Curve Weastgard mult-rvle. Cumulotive sum check, Twin Plot ‘QC Warning Out of contol auto waming, date Bomatic record and analysis ‘Operating System Windows 7/10 Date Storage ‘Decided by computer hard dsc capacity Us interface BiUSinterioce Print Mode Mult defauit formats, user-defined formats Real fire monitoring for sample disk, reagent disk; reaction disk Real ime monitoring for QC status. Real fime monitoring for reaction cuvettes System Monitor staius, lamp status ond temperature. Real time monitoring for reagent volume, feaction curve. calbralion curve and QC curve. linearly range imitation, substrate exhaustion judgement and prozone detecting. Abnormal status waming, User authority setting, test panel function, calculated/manual parameters programming, carryover setting, sample and reagent blank auto calculation, gether Funcien, ‘automatic failure recovery, aulomatic print, data statistic, auto/manval

You might also like