SIPROTEC 5 - Configuration 22.06.

2022 , 05:14:07 AM
________________________________________________________________________________________________

Device: 7UT85 Transf. Prot (2 Wind.)

Product code

Short: P1F705516
Long: 7UT85DAAAAA00AAAA0AF011113111BBAA000000AC0CC1BA1CC1CG0CG0

Technical Data:

Firmware: Current version


Binary inputs: 43
Binary outputs: 27 Relays (19 Standard, 8 Fast, 0 High-Speed, 0 Power)
Current transformers: 16 for protection
Voltage transformers: 0 standard
Measuring-transducer inputs: 0 (20 mA or 10 V, fast)
0 (20 mA, standard)
0 (temperature)
Housing width: 5/6 x 19''
Housing type: Flush mounting
Modules in 19" row 1: IO203, PS201, IO203, IO207, IO207
LEDs/Push-buttons: 16 LEDs
Operation Panel: Integrated
Key switch: Without
Display type: Large display
Front Design: Standard
Power Supply: DC 60 V-250 V, AC 100 V-230 V
Redundant Power Supply: No

________________________________________________________________________________________________
1/8
SIPROTEC 5 - Configuration 22.06.2022 , 05:14:07 AM
________________________________________________________________________________________________

Communication/Plug-in modules:

Communications encryption: Normal


Integrated Ethernet port J: for DIGSI 5
Plug-in module position E: ETH-BB-2FO: 2x optical Ethernet 100 Mbit/s, 1300 nm, duplex LC
connector
, 2 km over 50/125 um or 62.5/125 um multimode optical fiber
Communication Protocols: applicable for DIGSI 5, IEC 61850-8-1
MMS and
GOOSE, IEC 60870-5-104, DNP3 TCP, Modbus TCP,
Synchrophasor (IEEE
C37.118 - IP), Profinet IO, SUP, DHCP, SNTP, SNMP, etc.
Redundancy protocols: Line Mode, RSTP, HSR, PRP

Plug-in module position F: Port is available but not assembled

Functions:

Function points class: Base + 50 function points

Note on function-points class


The function-points class results from the sum of the function points of the selected functions. You can
apply these functions according to the selected function-points class. The device also allows each other
selection of functions if the sum of the required function points is within the selected function-points
class.

From Version V9.3 on the function-points class "1400+" is withdrawn. With this class function-points
exceeding the limit of 1400 were free of charge. The maximum function-points class is now 1400. If a
function-points budget of more than 1400 points is required for a device the application
Function-Point-Manager need to be applied. All function points are liable to cost.
In the engineering phase DIGSI 5 checks that the selected configuration is suitable (capable of running
in the device) before loading it to the device.

Miscellaneous:

Warranty: 5 years
Special Approvals: Without
Firmware: Current version

________________________________________________________________________________________________
2/8
SIPROTEC 5 - Configuration 22.06.2022 , 05:14:07 AM
________________________________________________________________________________________________

7UT85 Transformer Differential Protection - Overview Function points calculation

(P1F705516)

Included Functions

ANSI Function Abbr. Included


Hardware quantity structure expandable I/O

37 Undercurrent I<

38 Temperature supervision θ>

49 Thermal overload protection θ, I²t

49 Thermal overload protection, user-defined characteristic θ, I²t

50HS Instantaneous high-current tripping I>>>

50/51 TD Overcurrent protection with positive-sequence current I1 I1> 20 X


(from V7.9)

50N/ 51N Overcurrent protection, ground IN>


TD
50N/ 51N Overcurrent protection, 1-phase IN>
TD
74TC Trip-circuit supervision TCS

74CC Closed-circuit supervision (from V7.9) CCS

85/21 Universal teleprotection scheme for distance protection


(from V9.20)
85/27 Weak or no infeed: echo and tripping WI

85/67N Universal teleprotection scheme for directional ground


fault protection (from V9.20)
86 Lockout

87T Transformer differential protection ΔI

87T Node Differential protection (Node protection for auto ΔI Node


transformer)
87M Motor differential protection ΔI

AFD Arc-protection (only with plug-in module ARC-CD-3FO)

Measured values - standard

Switching statistic counters

________________________________________________________________________________________________
3/8
SIPROTEC 5 - Configuration 22.06.2022 , 05:14:07 AM
________________________________________________________________________________________________

PQ-Basic measured values: THD (Total Harmonic


Distortion) and harmonics (from V8.01) THD voltage
aggregation values (from V8.40)
CFC (Standard, control)

Inrush current detection

External trip initiation

Control

Fault recording of analog and binary signals

Monitoring and supervision

Protection interface, serial

Frequency-tracking groups (from V7.8) 6X

Temperature acquisition via communication protocol

Optional Functions

ANSI Function Abbr. Included Quantity Value Points


IEC 61850-9-2 Merging Unit MU 0 200 0
function (Note: Max. 2 streams
per MU function, each MU
function requires a
ETH-BD-2FO plug-in module)
Process Bus Client function PB client 0 100 0
(Note: This function requires a
ETH-BD-2FO plug-in module)
IEC 61850-9-2 Merging Unit MU (7SS85 0 295 0
function for 7SS85 CU (Note: CU)
Only for communication with a
7SS85 with Significant
properties: "CU: ...". This
function requires a
ETH-BD-2FO plug-in module)
IEEE 1588v2/PTP Grandmaster GMC 0 200 0
Clock (Note: This function
requires a ETH-BD-2FO, with
V9.20)
21/21N Distance protection Z<, V< 0 100 0
/I>/∠(V,I)
21GT Impedance protection for Z< 0 25 0
transformers
24 Overexcitation protection V/f 0 25 0

________________________________________________________________________________________________
4/8
SIPROTEC 5 - Configuration 22.06.2022 , 05:14:07 AM
________________________________________________________________________________________________

25 Synchrocheck, synchronization Sync 0 50 0


function
27 Undervoltage protection: V< 0 5 0
"3-phase" or
"positive-sequence system V1"
or "universal Vx"
27R, 59R Rate-of-voltage-change dV/dt 0 5 0
protection (from V8.30)
Undervoltage-controlled Q>/V< 0 5 0
reactive power protection
32, 37 Power protection P<>, Q<> 0 10 0
active/reactive power
32R Reverse-power protection - P< 2X 0 5 0

37 Power-plant disconnection -dP 0 50 0


protection
46 Negative-sequence I2> 0 5 0
overcurrent protection
46 Unbalanced-load protection I2² t> 0 5 0
(thermal)
47 Overvoltage protection, V2> 0 5 0
negative-sequence system
47 Overvoltage protection, V2/V1> 0 5 0
negative-sequence/positive-se
quence system
49H Hot spot calculation θh, I²t 0 20 0
50/51 Overcurrent protection, phases I> 3X 0 30 0
TD

Instantaneous tripping at SOTF 0 10 0


switch onto fault
50Ns/ Sensitive ground-current INs> 0 5 0
51Ns detection for systems with
resonant or isolated neutral
systems incl. a) 3I0>, b)
admittance Y0>, c) 3I0-harm>
(from V7.8)
Ground-fault detection via IN-pulse 0 15 0
pulse pattern detection; Note:
this stage additionally requires
the function 50Ns/51Ns or
67Ns "Sensitive ground-fault
detection for systems with
resonant or isolated neutral"
Intermittent ground-fault Iie> 0 20 0
protection
50BF Circuit-breaker failure CBFP 0 5 0
protection, 3-pole
________________________________________________________________________________________________
5/8
SIPROTEC 5 - Configuration 22.06.2022 , 05:14:07 AM
________________________________________________________________________________________________

50EF End-fault protection (Note: 0 5 0


Only useable for distributed
busbar protection with 7SS85
CU with V8.40)
50RS Circuit-breaker restrike CBRS 0 20 0
protection
51V Overcurrent protection, t=f(I,V) 0 10 0
voltage dependent
59, 59N Overvoltage protection: V> 0 5 0
"3-phase" or "zero-sequence
system V0" or "universal Vx"
59 Overvoltage protection: V> 0 5 0
"3-phase" or
"positive-sequence system V1"
or "universal Vx"
60 Voltage-comparison ΔU> 0 5 0
supervision
67 Directional overcurrent I>, ∠(V,I) 0 5 0
protection, phases
67N Directional overcurrent IN>, ∠(V,I) 0 15 0
protection, ground
67N Directional overcurrent IN>, ∠(V,I) 0 30 0
protection for ground faults in
grounded systems
67Ns Dir. sensitive ground-fault 0 30 0
detection for systems with
resonant or isolated neutral
incl. a) 3I0>, b) V0>, c)
Cos-/SinPhi, d) Transient
ground-fault fct., e) Phi(V,I), f)
admittance
68 Power-swing blocking ΔZ/Δt 0 25 0
Directional stage with a ∠(V0h,I0h) 0 10 0
harmonic; Note: this stage
additionally requires the
function "67Ns Dir. sensitive
ground-fault detection for
systems with resonant or
isolated neutral"
Directional intermittent Iie dir> 0 20 0
ground-fault protection
79 Automatic reclosing, 3-pole AR 0 45 0
81 Frequency protection: "f>" or f<>; df/dt<> 0 5 0
"f<" or "df/dt"
81 AF Abnormal frequency fBand 0 15 0
protection
81U Underfrequency load-shedding f<(UFLS) 0 15 0
Vector-jump protection Δφ> 0 20 0
________________________________________________________________________________________________
6/8
SIPROTEC 5 - Configuration 22.06.2022 , 05:14:07 AM
________________________________________________________________________________________________

87T Differential protection for ΔI 0 150 0


special transformers
87T Transformer differential ΔI 0 200 0
protection for phase angle
regulating transformer (single
core)
87N Restricted ground-fault ΔIN 0 15 0
protection
87G Generator differential ΔI 0 50 0
protection
87L Differential protection for lines ΔI 0 170 0
with 2 ends for 7UT8
(communication with
7SD82,85,86, 7SL86,87)
(extendable form V8.60)
87L Differential protection for lines 0 250 0
for more than 2 ends, per
additional end (from V8.60)
Option for line differential ΔI 0 40 0
protection charging-current
compensation
87 STUB Stub-fault differential 0 35 0
protection (for
breaker-and-a-half scheme)
90V Automatic voltage controller 0 150 0
for two-winding transformer
90V Automatic voltage controller 0 180 0
for two-winding transformer
with parallel operation
Number of two-winding 0 5 0
transformers with parallel
operation (Note: only together 2X
with the function "Automatic
voltage controller for
two-winding transformer with
parallel operation")
90V Automatic voltage controller 0 200 0
for three-winding transformer
90V Automatic voltage controller 0 175 0
for grid coupling transformer
FL Fault locator, single-sided FL-one 0 25 0
FL Fault locator plus (from V7.9) FL plus 0 45 0
PMU Synchrophasor measurement PMU 0 40 0
Measured values - extended: 0 3 0
Min, Max, Avg
PQ-Basic measured values: 0 20 0
Voltage unbalance (from
V8.40)
________________________________________________________________________________________________
7/8
SIPROTEC 5 - Configuration 22.06.2022 , 05:14:07 AM
________________________________________________________________________________________________

PQ-Basic measured values: 0 30 0


Voltage variations - voltage
dips, swells and interruptions
(from V8.40)
PQ-Basic measured values: 0 10 0
TDD - Total Demand Distortion
(from V8.40)
CFC arithmetic 0 40 0
Circuit-breaker wear ΣIx, I²t, 2P 0 10 0
monitoring
Switching sequences function 0 5 0
PoW Point-on-wave switching (from PoW 0 425 0
V7.90)
Circuit-breaker 4X 0 3 0

Disconnector/Grounding 4X 0 3 0
switch

SSR Slow-scan recorder (from SSR 1X 0 40 0


V8.80)

Transformer side 7UT85 2X 0 70 0

Cyber Security: Role-Based 0 25 0


Access Control (from V7.8)
Cyber Security: IEEE 802.1x 0 10 0
based network authentication
(from V8.3)
Total: 0

________________________________________________________________________________________________