REVISION LOG
Revision Changes Date Author
~ All 05/18/2017
A 8.4, 9.1.2 06/21/2017
B 1.2.2, 5A.7 07/03/2017
C 5A.6, Added Section 9.1.3 08/07/2017
D 3.3.2 & 3.3.3 12/21/2017
E 1.3, 5A.3, 5A.5, 9.1.3, 9.2 07/17/2018
F Update 1.2.2, 3.3.2 09/05/2019
G Updated 1.2.2 & 5A.5 11/26/2019
Updated Title Page, 1.2.1, 1.2.2, 1.2.3, 3.2.1, 3.2.1.1, 3.2.1.2, 3.2.1.3,
H 3.2.1.4, 3.3.1, 4, 5B.2, 9.1.1, 9.1.2, 08/11/2020
Added 3.3.4, 3.3.5, 3.3.6, 5A.8, 5B.5, 6.5, 6.6, 9.4, 9.5, 9.6
J Updated 5A.8.14 10/07/2020
Updated 1.1, 3, 3.1.1, 3.3.3, 3.3.6, 5A, 5A.8.14, 6.2, 7.1, 7.2, 9, 9.1.1,
K 9.1.2, 10, 10.1, 10.4, & Appendix I 12/03/2020
Added 3.3.7, 3.4, 6.7, 6.8, 9.7, 9.8, & Appendix II
Updated title page layout to the template rev AZ.
Updated the Revision Log to the template rev AZ.
L Section 3.3.4: Update inspection to have receiving send a sample to 5/17/2022 MPG
as we do not have Color Matching samples. This is
performed by
Acceptance Criteria: Leather must not have visual imperfections, be uniform in color, and
approved by .
Specifications: 14 CFR Part 23.853 (a), Appendix F Part I (e) and FAA Materials Fire
Test Handbook, DOT/FAA/AR-00/12
Defect Classification: Critical
Method of Inspection: Check the files located at O:\Receiving\Silicone Burn Tests. Files
are to be saved as P/n_date-of-report.pdf
Date on test to be less than three years previous. If no test is present or the date is older
than listed, send samples to lab capable of doing the 2.5 IPM Horizontal Test per
associated specifications. Move old test report to “Obsolete” folder and save new test
report in this location using the above naming convention.
Acceptance Criteria: The averaged sample burn rate of the three samples to be less
than, 2.5 inches/minute
Instructions: Record the file name of the test report and list the category as burn rate on
form QC-210.
CONFIDENTIAL AND PROPRIETARY
This document contains confidential and proprietary information and may not be
disclosed without the express written consent of McFarlane Aviation Products.
Page 12
McFarlane Aviation, Inc.
Production Specification 118, Rev L
05/17/2022
3.4 Hardware (Terminals, Clevis, Caps, Safety Wire, etc.)
Sampling Method: ANSI/ASQ Z1.4, Level S-2. Use an acceptance number of zero rejects.
Specifications: applicable standard, Customer Drawing, or McFarlane Drawing
Defect Classification: Major
Method of Inspection: Using calibrated equipment measure the dimensions listed on the
drawing or standard.
Acceptance Criteria: All dimensions must fall within the listed tolerance ranges.
Instructions: Record each dimension as its own line on form QC-210.
4. Storage Requirements
All cable in storage must be protected from dust and other shop contamination. Work areas
must be clean. The standard storage requirements of the McFarlane Aviation, Inc. Quality
Assurance Manual are applicable.
All tubing in storage must be protected from dust, oil, solvents, direct sunlight, and other shop
contamination. Work areas must be clean.
Leather and associated wrapping materials in storage must be protected from dust, oil,
solvents, direct sunlight, and other shop contamination. Work areas must be clean.
Figure I
Figure II
Place the cable beside the fitting shank and have mark (A)
placed flush with the bottom of the shank. Mark the shank at
point (B) using the end of the cable as shown in Figure II.
Figure III
Place the cable next to the mark (B) and mark the shank at point
(C) as shown in Figure III. (One cable diameter). Re-insert the
cable fully into the terminal, until mark A (Figure I) is flush with the
end of the terminal.
Advance the roll dies so that there is clearance to insert the cable and terminal between
the rollers and the end of the terminal not being swaged in against the end of the stop
(item C in equipment picture above). Adjust the stop till line C marked on the terminal is
in line with the center of the roller dies (dashed line D in equipment picture above). Do
not start the swage on line B, or the swaging process may push the cable out of the
terminal.
Rotate the roll dies until they have passed over the terminal shank. When the first pass
has been completed, a longitudinal fin or "flash" on two diametrically opposite sides of
the terminal will be noticeable on the swaged portion of the shank. To eliminate the
longitudinal fin, rotate the terminal 90 degrees from the first swaging position and pass it
through the rollers again. Rotate the sample 45° and repeat the swaging process,
rotate another 90° and repeat the swaging process a final time. Do not swage terminal
more than 4 passes as it can lead to work hardening and swage cracking.
Apply 3M 467MP ½” wide adhesive transfer tape (ATT) to the full length of the skived
edges.
3M Adhesive
Fold on itself
creating seam edge
Mark center of the length of the leather at the seam eedge with a white Staedtler
Omnichrom Pencil on the finished side of the leather.
Apply 3M 9472LE 1” wide ATT on the flesh side of the strip along the full length.
5A.8.14 Start baseball stitch with one piece of thread that is at least 7’ long with a needle
threaded on each side.
Stitch down the length until you reach the center mark. Pull threads tight and tie off at the
center mark using a square knot tied off at least four times.
Apply a drop of Cyanoacrylate adhesive (Super Glue) to the knot.
Using a new length of thread, begin stitching the leather at the midpoint and continue down
the length of the silicon in the same manner as before. Finish at end and tie off and apply
adhesive to knot.
Assemble cable per McFarlane Drawing 7543 CENTER leather wrapped cable between
end terminals. Use End Cap 7542-XXX which fits snugly over the leather without
Fill voids in end caps with Silicone adhesive (Dowsil 732) until the silicon begins to
squeeze out of the end of the end cap. Wipe away excess silicone and allow to cure.
6. In-Process Inspections
Due to the low critical nature of these cables, the secondary personnel check/signoff of the in-
process inspections is waived.
6.1 60% proof load test
Sampling Method: 100% using an acceptance number of 0 defects.
Specification: 60% proof load test.
Defect Classification: Major
Method of Inspection: Pre-stretch and proof load each cable assembly to 60% of the
minimum breaking strength of the cable as per the Table XL in RR-W-410 or applicable top
level drawing.
Acceptance Criteria: Cable assembly must hold required applicable load without slipping
or failing.
Instructions: Record “pass” or “fail” as one line on form QC-210.
6.2 Cable assembly length and proper cable termination
Sampling Method: Inspection Level II with an acceptance number of 0 shall be used.
Specifications: Cable assembly length and proper cable termination
Defect Classification: Major
Method of Inspection: Methods of measuring the cable assembly lengths and the
tolerance for the cable assembly lengths shall be as specified in the McFarlane Aviation,
Inc. FAA approved design data. Visually inspect for proper cable termination and
construction (1x7, 7x7, 7x19, etc.). Construction may be determined by counting the
number of strands visible at the cut end if a visual inspection of the stranding does not yield
a definitive answer. Verify the proper type of cable has been used (Comp. A or Comp. B).
This can be accomplished visually (by experienced personnel), with a magnet, or with a
resistance test. Refer to Inspection 3.2.1.3 for details.
Acceptance Criteria: Cable assemblies shall have proper termination, cable type,
construction, and length as per FAA Approved Data.
Instructions:
• Record the range of measured lengths as one line with the category listed as
“LENGTH” on form QC-210.
• Record the cable termination as “PASS/FAIL” as one line with the category listed as
“TERMINALS” on form QC-210.
• Record the cable constructions as “PASS/FAIL” on one line with the category listed
as “CONST” on form QC-210.
• Record the cable composition as “PASS/FAIL” on one line with the category listed as
“COMP” on form QC-210.
CONFIDENTIAL AND PROPRIETARY
This document contains confidential and proprietary information and may not be
disclosed without the express written consent of McFarlane Aviation Products.
Page 25
McFarlane Aviation, Inc.
Production Specification 118, Rev L
05/17/2022
6.3 Swage Quality and Dimensions
Sampling Method: Inspection Level II with an acceptance number of 0 shall be used.
Specifications: Swage quality and dimensions
Defect Classification: Major
Method of Inspection: Inspect to determine conformance to the applicable drawing and
requirements not covered by the above test and inspections. Use a 5x minimum optical
magnifying glass when visually inspecting swaged terminals.
Acceptance Criteria:
• Shank Terminals - After swaged terminal dimensions "As" must extend a minimum
distance "X" from cable end of shank terminals as per applicable terminal standards
drawings.
Note: Terminals swaged with the Kearney swaging machine will not be exactly
round and must only pass the As dimensional check in a minimum of three places
while rotating around the shank.
• Ball Terminals - After swaged terminal dimensions "As" and "Bs" must meet the
specifications for ball terminals as per applicable terminal standards drawings. The
cable must extend through the fitting and protrude no more than .062” when the
fitting is positioned at the end of a cable assembly.
• All Fittings - Swaged areas of the terminals shall have a smooth surface free from
rapid dimensional changes in cross section, shall not become brittle as a result of
cold working, and shall not contain splits, cracks, and other injurious defects.
Note: Terminals swaged with the Kearney swaging machine will not be exactly
round and must only pass the As dimensional check in a minimum of three places
while rotating around the shank.
• Cable - The cable must show no defects and the cable assembly must be free from
dirt or other contamination.
Instructions: Record as “pass or fail” one line on form QC-210.
6.4 All Cable Assemblies (Swage Minimum Dimensions& Detail)
Sampling Method: One swaged assembly per lot and for each time the swage die is
changed, accept no defects.
Defect Classification: Major
Specification: Applicable terminal drawings and Section 5 of this specification.
Method of Inspection: Using a calibrated precision micrometer, measure and record the
range of each of the applicable swaged dimensions (taper), for each terminal used in the
cable assembly.
Acceptance Criteria: Swage dimensions must fall within the applicable terminal drawing
requirements.
Taper: Taper in the O.D. of the shank may not exceed 40% of the allowed after
swaged tolerance.
Instructions: Record each of the applicable dimensions as a range on a separate line on
form QC-210.
7. Tool Calibration
When gages are used to measure finish swage dimensions and or other terminal dimensions,
the gages must be calibrated. All standard measuring equipment used to measure terminal
dimensions must be calibrated. Since the cable-testing machine must apply the specified test
load to the cable assembly, calibration of this machine is required.
7.1 When inspection gages are used, they must be calibrated when fabricated or repaired
and inspected for proper calibration at intervals as listed on the Equipment Calibration
Record, Form QC 510. Record the calibration inspection as per Section 7.1.5 of the
Quality Assurance Manual. The dimensions of any gage used shall be the limiting
dimension allowed by the terminal specification the gage is designed to measure. The
allowed gage tolerance from the specified dimension is .0005 inch. The tolerance is
unilateral from the limiting dimension allowed by the applicable approved specifications
such that any product dimension outside of the limiting specification dimensions would not
be accepted by the gage. In other words, the tolerance of the gage shall be such that a
slightly out of tolerance part or product would never be accepted by the gage.
7.2 The pull test machine uses air pressure controlled by a dead weight regulator. The
regulator system prevents excessive loads being applied to the cable assembly. This air
pressure acts upon an air cylinder piston with a low friction seal to apply the proper force to
the cable. An air pressure gage is used to monitor the process. A load cell is used to
measure the exact force being applied. The following calibrations of the cable test
machine components are required. Record the calibrations as per Section 7.1.5 of the
Quality Assurance Manual.
7.2.1 Regulator weights and shaft must be calibrated to the applicable weights listed on
Table I of this production specification titled, "Cable Test Machine Operating
Specifications".
Acceptable weight tolerance is plus or minus 3 grams. Calibration inspections of the
weights and shaft must be done every 5 years after the initial inspection or before
weights are placed in service after any repairs.
7.2.2 Since the air orifice size of the regulator is critical to the proper regulation of air
pressure, it must be inspected for the proper dimension, .252 inches (plus or minus
.001). This calibration check should be done every 36 months or after any repair. (The
orifice is hardened tool steel.)
7.2.3 The load cells and meters shall be calibrated for accuracy every other month, after
a cable failure during test, or after other situations that might have damaged the system.
The load cell must be calibrated at the points (in lbs.) that will be used to test cables. A
CONFIDENTIAL AND PROPRIETARY
This document contains confidential and proprietary information and may not be
disclosed without the express written consent of McFarlane Aviation Products.
Page 28
McFarlane Aviation, Inc.
Production Specification 118, Rev L
05/17/2022
calibration correction chart must be maintained that reflects the corrected indications
required for each test point. The correction chart shall reflect an average of the meter
reading when the load is increasing to the test point and the meter reading when load is
decreasing to the test point. The test bench load cell shall be accurate without
correction to a maximum of 25% of the tolerance range allowed by the proof test. The
load cell system used to calibrate the test bench load cell must be accurate to 25% of
the test bench load cell accuracy requirements.
7.2.4 Test the MIL-PRF-16173 preservative compound periodically as detailed in
Procedure Specification MCSTD-3.
7.3 The swage dies, used in the rotary swaging machines must be created and maintained
per McFarlane Procedure Document PR18.
8.5 Place the cable assembly or assemblies in a plastic bag or other protective container.
An air tight seal is not required. The minimum cable coil diameter must be at least 60
times the diameter of the cable.
8.6 Replacement Parts:
None
9. Final Inspections
Note: Inspections must be accomplished by personnel qualified by Section 5B that did not
fabricate the assembly.
9.1 Silicone Tubing Cleanliness
Sampling Method: 100% with no defects allowed.
Specification: None
Defect Classification: Minor
Method of Inspection: Visual inspection.
Acceptance Criteria: The tubing must have no grease, oil, or other dirt showing on the
outer surface. The surface of the silicone must be free of contamination, grit, splits or
lumps. If tubing is found to have defects, soiled areas may be cleaned with a mild
detergent and water on a clean rag. DO NOT USE SOLVENTS OR ALCOHOLS as it will
deteriorate the silicone surface.
Instructions: Record as “pass” or “fail” one line on form QC-210.
9.1.1 Cable assembly silicone setback length and proper trimming
Sampling Method: Inspection Level II with an acceptance number of 0 shall be used.
Specifications: Silicone coating proper setback length and trimming form
Defect Classification: Major
Method of Inspection: Using standard calibrated equipment, measure each door control
setback length (distance from terminal reference point to end of chamfer or corner of
silicone coating) and angle of taper (where applicable). Visually verify that taper cut is
uniform and clean and neat in appearance.
Acceptance Criteria: Silicone coating setback length and end taper shall meet the
requirements of the applicable top level drawing. Taper surface shall be smooth and
uniform and will not have any jagged edges or disruptions.
Instructions: Record the range of measured setback lengths as a single line and “pass” or
“fail” one line labeled “visual appearance on form QC-210.
10.4 Disposition
10.4.1 If parts meet the requirement of 10.1 and 10.2, after allowable rework of 10.3,
return parts to the Sales Department for re-stocking.
10.4.2 Unsatisfactory parts shall be dispositioned per section 8.5.5 of the McFarlane
Aviation Quality Assurance Manual.
4. Trim tube.
a. Slide tube onto mandrel to back edge of grove.
b. Turn on lathe.
• Make pilot holes in the tube at the taped areas with stiff sharp wire to aide in the insertion of
injection/vent needles.
• Place injection needle into the tube at the opposite end of the vent, insert until you just feel it touch
the cable inside the tube. Injection gun to be at an angle pointing towards the end of the
assembly with the vent needles.
• Pull the trigger on the injection handle, wait until timer has expired. Proceed to next injection point
and repeat process along entire length of cable until reaching the vent hole.
• It is ideal when completing the last injection that the silicone will seep from the vent hole.
• Once silicone has dried overnight, remove tape and clean off excess silicone from the outside of
the assembly.
• Do final inspections, clean the assembly and apply a light coat of corn starch. Place accepted