Oxygen concentration one-button Self-check function when start up LED touch screen
auto-calibration
NV8
avoid incorrect operation due to human error, ensure ventilation safety, reduce medicare 8’’ LED-backlit LCD, touch screen; clear and
provide accurate and reliable oxygen providers’ waiting time and get ready to bright from multiple angles, monitoring data
concentration data. use machine . highlighted; intuitive setting design reducing
Neonatal Ventilator
human errors, enabling doctors focusing on
neonates.
Specially designed for neonates, NV8 provides the most professional and
diversified noninvasive nasal ventilation modes with advanced apnea
wakeup function and automatic leakage compensation function.
Safe and reliable Oxygen sensor: City sensor, long service life, Accurate and safe fresh gas delivered by iFlow Intelligent
Double CPUs: double protection
high precision, quick response. Closed-loop Control System to protect fragile new life;
User-friendly operating system with easy clinical practice
Electronic flow sensor: Flow sensor provided by Honeywell When setting key parameters like pressure and to facilitate medical staff;
Proximal pressure monitoring: without being affected by mechanical
dead space in the closed loop and compliance, accurately measure oxygen concentration, intelligently give out safety Integrated ventilation solutions providing SNIPPV/NIPPV,
patient’s airway pressure, the most recognizable method signs to avoid maloperation. NCPAP and HFNC modes for safe ventilator weaning.
in the industry.
Proportional valve: Norgren valve, with stable performance. Built-in lithium battery, with over 4hrs working
time, guarantee normal operation during power
failure and transportation.
NIPPV waveforms Maximum 15 seconds long inspiratory time, ensuring smooth and Incorporates with Medin company’s Medijet pressure generator;
spontaneous breathing under bilevel pressure. Patented technology using Coanda effect;Produce
proximal positive airway pressure.
Direct oxygen concentration setting Proximal pressure
The most stable respiratory waveform
sensor
rea
k
ac
l-ti
db
Traditional CPAP devices use mechanical air/oxygen
m
fee
em
e
blender, or oxygen flowmeter and air flowmeter regular CPAP facility
tim
oni
al-
gas channel pressure
tor
combination, complicated to operate, easy to affect
re
ing
accuracy due to mechanical wear. SNIPPV (synchronized nasal intermittent positive
NV8 uses electronic air/oxygen blender:with one button iFlow pressure ventilation) + backup ventilation)
pressure
to set the value of oxygen concentration and can
auto-proportionate oxygen and air flow. High-precision Flow control Synchronization with breathing: when patient inhales, its abdomen goes
Patient
flow sensor and proportional valve equipped enable module up and triggers the sensor to send out inspiratory pressure synchronically,
real-time feedback and oxygen concentration reducing man-machine confrontation and WOB, smoothing the breath.
precision within ±3%. Abdomen attached respiration sensor: accurately identify respiratory waveform,
intelligent adjustment synchronically be triggered and precisely monitor respiratory rate (RR). Exhaled air vented out proximally, reducing CO2 residual more effectively
and also reducing at most 75% WOB compared
Backup ventilation: when patient stops breathing for longer than the preset
SNIPPV+ Synchronous trigger waveforms with traditional CPAP devices.
apnea interval, NV8 will automatically switch to backup ventilation and ventilate
patient as per preset RR to prevent sleep apnea.