You are on page 1of 39

LENZE 9400 + 8400

8. Februar 2017
Markus Prei, Oct 2014
2

LENZE 9400 + 8400

Different power, 0,37 – 370 kW


Different size
Different types

See doc: SW_E94AxHExxxx_Parametrierung_HighLine_(ab_Firmware_01-50)_v7-0_EN.pdf


http://src.lenze.com/lenze-bibliothek/en/_start.htm
3

AC Motor Y - delta

• coil resistance
• U1-U1, V1-V2, W1-W2
4

Variable speed

n = (f x 60)/p
5

Decentralized DC BUS
neg. feedback unit
6

Decentralized DC BUS
brake chopper
7

drive types 8400


8

drive types 9400


9

Feedbacksystems
TACHO

e.g. 60V / 1000 rpm


10

Feedbacksystems
RESOLVER

low cost
robust
11

Feedbacksystems
ENCODER

compatible to many
systems
square wave signal

expensive
not robust
no absolute rotorposition
steep flanks

since 2014: preset for zero pulse in


HQM (IVE 62-00002)
12

Feedbacksystems
SinCos ENCODER

sincos encoder
single turn
multi turn
13

Zeropulse
14

Speed setting
15

Speed setting: analog


16

Speed setting: analog and dig. frequ.


17

Speed setting: dig. frequ


18

Speed setting: PROFIBUS + Encoder


19

master slave
20

PROFIBUS - overview
21

System overview 9400


22

Onboard interfaces 9400


CANopen system bus

I / O´s

Diagnostic LED

Diagnostic adapter port

Feedback systems
23

Variable modules 9400

M X I 1:
Module slot for extension 1 e.g.
Profibus, Profinet, Ethernet

M X I 2:
Module slot for extension 2 e.g.
guiding frequency

M M I:
Module slot for memory module

M S I:
Module slot for safety module (SM0
= no function)
24

Profibus module 9400


25

Profinet module 9400


26

Digital frequency module 9400


27

MMI Memory module 9400

• MMI 220, 330, 440


• MMI x4x with real time clock (battery)
• baud rate (C 350), CAN address (C 351)
28

Diagnostic LED´s 9400

CAN-RUN CAN-ERROR
off = CAN not activ
= bus warning
= pre-operational
= bus off
= operational

DRIVE-ERROR
DRIVE-READY off = OK
off = initialisation active = bus warning
= device is switched on = bus off
= operation

USER
programable, e.g. reference ok
24 V
29

Diagnosis DRIVE – STATUS 9400

- Ready, except DC BUS


- Ready

cycle power!
30

System overview LENZE 8400


BaseLine
(steady movement)

StateLine
(controlled movement)

HighLine
(positioning)

TopLine
(servo function)

motec.d
(decentral on motor) TopLine C HighLine C BaseLine C

See doc: SW_E84AVTCxx_Parameterisation_TopLineC_v2-0_EN.pdf


http://src.lenze.com/lenze-bibliothek/en/_start.htm
31

KEY PAD

4 Navigation keys
2 context sensitive function button
Programable Run- and Stop button
Display of controller status

Application has to be on drive already


Save parameter C002/11
Wait 60 seconds when saving the parameterset to EPROM!

C 0183 device state (wrn, trbl, flt, …)


C 0166 error description (clear text)
C 0168 error number (decimal)
see: SW_E94AxHE__Servo Drives 9400 HighLine (from Firmware 01-50)__v10-0__EN 2013.pdf
SW_E84AVTCxx_Parameterisation_TopLineC_v2-0_EN .pdf

Hints:
Only for diagnosis & parametrisation
Storing of application into memory module
Key-Pad has no EEPROM
(no parameter transfer inbetween drives)
32

Important parameters 9400 ??


Function: Display:
C 002 device controll C 050 nominal 1 speed (rpm)
C 007 active Application C 051 act speed (rpm)
C 011 n-max C 052 act motor voltage
C 022 I-max limit C 053 act DC Bus voltage
C 0169 Logbook setting C 054 act mot current
C 586 to activate / deactivate resolver monitoring (0 = no C 059 Motor – number of pole pairs
response) C 060 rotor position
C 607 to activate / deactivate max speed reached monitoring C 061 heatsink temp
(0 = no response)
C 062 temp inside controller
C 063 temp motor
C 064 Ixt (device utilisation within last 180s)
C 065 ext. 24-V supply
C 066 I²xt (thermal motor utilisation)
C 068 capacitor temperature
C 069 CPU temperature
C 178 running time [s]
C 179 power on time [s]

C 166 error description (clear text)


C 168 error number (decimal)
C 183 device state (wrn, trbl, flt,
Faulthistory see logbook
33

Important parameters 8400 ??


Function: Display:
C 002 device controll C 050 nominal 1 speed (rpm)
C 007 active Application C 051 act speed (rpm)
C 011 n-max C 052 act motor voltage
C 022 I-max limit C 053 act DC Bus voltage
C 0169 Logbook setting C 054 act mot current
C 586 to activate / deactivate resolver monitoring (0 = no C 056 torque setpoint / actual value
response) C 058 output frequency
C 607 to activate / deactivate max speed reached monitoring C 059 nr. of motor polpairs
(0 = no response)
C 061 heatsink temp
C 062 internal temp
C 063 temp motor
C 064 Ixt (device utilisation within last 180s)
C 065 act voltage from ext. 24-V supply
C 066 I²xt (thermal motor utilisation)
C 099 firmware version
C 158 source of controller inhibit
C 178 running time [s]
C 179 power on time [s]

C 166 error description


C 168 error number
C 183 device state
Faulthistory see logbook
34

Faultdiagnostics
Display:
Note: decimal, hex, bin

C 166 fault description


C 168 fault number
C 183 device state
Faulthistory see logbook
35

Remarks 2014

BHS specific firmware since 3. Quart 2014. See type plate with BHS part nr.
(for safe BUS communication)

Faultmessage: „parameterset invalid – red fault LED flashing“


This occurs after replacing a drive using the old memory module while the new drive has a later firmware
version. This is only a message and does not influence the drive function. To overcome this message just
save the parameterset once (C 002 = 11) this will upgrade the parameterset to the new firmware
version.
Attention: after this, the memory card can not be used with an older drive anymore. Only downloading a
backup with old firmware version will help.

PROFINET address: the PROFINET address is saved on the memory module. During every boot it is
transferred to the PROFINET module. (Swapping PN modules without rebooting will cause wrong
addresses!)
36

Remarks 2015

Easy Starter features:


- OPC UA server
- free of charge download at Lenze.com
- used for service, backup, download
- also for download PLC applicatons
- to access 8400 / 9400, 8200 / 9300, ECS
37

Remarks 2015

Faultmessage: 0x014500025 „dF25 CU RCOM“ can´t be reset


This occurs only drives 8400 Top Line FW V15.01 when switching on at high ambient temperature.
Solution:
- switch off – cool down – switch on or
- upgrade to FW V15.02 or
- replace drive
see: Tech_Trainer_EL\020_Documents_Basics\3_LENZE\Documents
38

Easy Navigator
Easy Starter

Easy Starter (Application loader)

Easy Starter (Lenze smart motor)

Engineer
39

END

You might also like