ENGINEERING
HUH RAWING
Q RACTICE
HUB ODE
Engineering Group
Design Team
November,2007
DOC.No.EG-DO-C-001 PAGE 1 OF 109 REV.O
Engineering Group
Design Team
TABLE OF CONTENTS
1.0 INTRODUCTION
2.0 SCOPE
3.1 Presentation
3.2 General Piping Guidelines
3.3 General Dimensioning Guidelines
3.4 Colour Coding for checking
3.5 Dimensioning Samples
3.6 Drawing Scales
3.7 Graphic Scales
3.8 Location Plan
3.9 Key Plan
3.10 Section Indicators
3.13 Piping and Civil Drawings (Other than those for Buildings)
3.17.1 Plan
3.17.2 Elevation
4.1 General
4.2 KOC P8JD Numbering System
4.3 Equipment Numbering System
4.4 Line Numbering System
DOC.No.EG-DO-C-001 PAGE 3 OF 109 REV.O
TABLE OF CONTENTS
TABLE OF CONTENTS
8.1.12 Miscellaneous
8.1.13 Level Instruments
8.1.14 Temperature Instruments
8.1.15 Pressure Instruments
8.1.16 Flow Instruments
b) Filters
c) Tanks
d) Heat Exchangers
e) Pumps
f) Mixing Devices
h) Drivers
i) P&ID Abbreviations
k) Instrument identification letters
TABLE OF CONTENTS
8.7.1 General
8.7.2 Doors
8.7.3 Windows
8.7.4 Kitchen & Toilet
8.7.5 Materials
8.7.6 Walls
8.7.7 Miscellaneous
TABLE OF CONTENTS
9.0 PRINT ROOM OPERATING PROCEDURES
9.1 Introduction
1.0 INTRODUCTION
1.1 The Engineering Drawing Practice Code (EDPC) amalgamates and updates
the various requirements covered in various existing documents.
1.3 This code is for use by Kuwait Oil Company (KSC) and its Contractor.
1.4 This issue of Engineering Drawing Practice Code (EDPC) supersedes the
following existing KOC documents :
• Engineering Drawing Office Practice Code, issued earlier.
2.0 SCOPE
3.1 Presentation
e) Nominal pipe sizes and valve bores should be given in Imperial units
unless otherwise requested.
131.20
100
(REF.)
ID ID
o o
a) The Following metric scales are preferred in laying out the drawing contents.
1:1 1:10 1:50 1:500 1:2500 1:40
1:2 1:20 1:100 1:1000 1:5000 1:33 1/3
1:5 1:25 1:200 1:2000
b) All layout and general arrangement drawings shall be drawn to scale. The
scale shall be indicated in the scale section of the title block.
c) If for reason of clarity more than one scale is used, the scale used will be
clearly indicated below each view or detail and the text as 'AS SHOWN'
shall be printed in the scale section of the title.
d) For schematic drawings (e.g. P & ID's), the word 'NONE' shall be printed in
the scale section of the title block.
e) On scaled drawings where for reasons of clarity the physical dimensions are
drawn "Not To Scale" the dimension shall be annotated below the dimension
text thus '(NTS)'.
3.10 Section I n d i c a t o r s
a) A North point shall appear on every plan and shall be designated True, Refinery
or Plant Grid.
T
25
in
TRUE/x _ 0|
43 25
a) The true or Grid North shall point to the top of the sheet see Option 1 & 2.
b) Double arrows giving the relationship between True and Site or Plant Grid
Norths shall be used on layouts and Surveys only see Option 3; for surveys,
the angle of variation should be added.
DOC.No.EG-DO-C-001 PAGE 12 OF 109 REV.O
The orientation of all piping plans and civil arrangement plans shall be the
same as Plant Layout. Plans for sub-assemblies and Layout part plans must
have the same orientation as the main plan layout.
3 . 1 4 A r c h i t e c t u r a l a n d Associated Plans
a) On building plan the main entrance is normally shown towards the bottom
of the drawing sheet. The north arrow shall be added to the plan showing
its true position, i.e. North arrow may be shown towards the bottom of
the drawing sheet.
b) All other plans relating t o t h e same building should have t h e same
orientation e.g. RC foundation, drainage, plumbing and power and lighting.
The directional symbol on the pipeline isometric sheet /detail shall be shown
as in Option 1 or 2
TOP RIGHT HAND CORNER OF ISOMETRIC SHEET / DETAIL
Option-1 Option-2
3.16 Nozzle O r i e n t a t i o n
The north arrow on vessel drawings contains designation of 0 ° for " N " ,
90 ° for "E", 180° for "S" , 270° for "W" and the orientation of a nozzle in
plan is determined by this method.
DOC.No.EG-DO-C-001 PAGE 13 OF 109 REV.O
3.17 O r t h o g r a p h i c Projection
/ EXISTING \
/ TANK "E"
13000 HIGH
TANK "A"
TANK "C"
TANK "D"
a. The full line of Tank C is taken through the future extension of Block F and the Existing Tank E.
c. Tank C is shown in a short-dash line behind Tank D but not behind both Block F and Tank D.
This convention sets a limit to the extent of the hidden edges and in certain cases gives
added information in the view, e.g. from the elevation alone Tank B is seen to be directly
behind Block F and also behind Tank C.
d. Tank A is stopped at Tank C and at the outline of Tank E since A is behind in each case.
e. Edges of future or existing items that are behind other outlines should not be shown.
DOC.No.EG-DO-C-001 PAGE 14 OF 109 REV.O
000-00-000
-DISCIPLINE CODE
DISCIPLINE DRAWING
CODE TYPE DESCRIPTION
407-5-316
FACILITY/AREA CODE
DISCIPLINE CODE |
SEQUENTIAL NUMBER
25-G-l 0 1 A
PLANT NUMBER ^
EQUIPMENT IDENTIFICATION PREFIX
TRAIN = 1,2,3, ETC. (COMMON=0)
SEQUENTIAL NO. |
PARALLEL/STANDBY/SPARE UNITS(A,B,C,ETC.)
16"-PL-1090-C15A-HC
LINE SIZE |
FLUID DESIGNATION
LINE NUMBER
LINE CLASS (REFER PIPING MATERIAL SPEC.)
INSULATION DESIGNATION
DOC.No.EG-DO-C-001 PAGE 16 OF 109 REV.O
ALL 210
AO
A4
oo rM
-<£ ARROW
15
TITLE
15_
±1
210
TITLE
25 25
1189
ALL210
A1 +
rM A3
00 rj»
ID
i^MJI-^t
rji
rM 15 15
_—
TITLE 420 '
15 15
970
ALL 210
210 210
1
Al —\ 1
LnT
A2
[ O
rM
r H LT)
TITLE
i
i TITLE ■ ~k
i N—1
15 L~ 15
594 ^
15 15
841
DOC.No.EG-DO-C-001 PAGE 17 OF 109 REV.O
AO
841x1189
33"x 47"
Al +
686 x 970
27"x 38"
Al
594 x 841
23"x 33"
A2
420 x 594
16.5" x 23"
A3
297 x 420
11.7" x 16.5"
A4
210x297
8.3" x 11.7"
DOC.No.EG-DO-C-001 PAGE 18 OF 109 REV.O
EQUIPMENT EQ 7 BLACK
MISCELLANEOUS MISC 21 21
HYDRAULIC SIGNAL HS 40 40 -b b b-
6.2 Piping
DESCRIPTION CAD LAYER COLOUR No. COLOUR NAME LINE TYPE
EQUIPMENT EQ 7 BLACK
LPGAS LP 40 40
HP GAS HP 40 40
CONDENSATE COND 30 30
DOC.No.EG-DO-C-001 PAGE 19 OF 109 REV.O
MISCELLANEOUS MISC 21 21
NITROGEN N2 46 46
6.3 Electrical
DESCRIPTION CAD LAYER COLOUR No. COLOUR NAME LINE TYPE
EQUIPMENT EQ 7 BLACK
6.4 Civil/Architectural
DESCRIPTION CAD LAYER COLOUR No. COLOUR NAME LINE TYPE
GRIDS GR 8 GRAY
7.2 Piping and Instrument Diagrams, Process Flow Diagrams & Signal Lines
WIDTH
DESCRIPTION (mm) LINE TYPE SYMBOL
PUMPS (DRIVERS:GM=MOTOR,
G SU SUMP
GT TURBINE, GE=ENGINE)
XA METHANOL XN POLYELECTROLITE
CSA COLD & SPECIAL ACOUSTIC HSA HOT & SPECIAL ACOUSTIC
X X X CAPILLARY TUBING
ELECTRICAL
$ TELEMETRY SIGNAL
^ ^ ELECTROMAGNETIC/SONIC SIGNAL
o™
B
LOCALLY MOUNTED FOUNDATION FILEDBUS
COMPLIANT INSTRUMENT
u
PLC-YYY
PILOT LIGHT LOCAL
r^ f
rr\ >
<
DCS LOGIC NORMALLY ACCESSIBLE TO OPERATOR
\xxx/ (XXX LOGIC DIAGRAM SHEET NUMBER)
PLC-YYY
PROGRAMMABLE LOGIC OR SEQUENCE CONTROL ACCESSIBLE
r TO OPERATOR (YYY PLC NUMBER)
(XXX LOGIC DIAGRAM SHEET NUMBER)
8.1.12 Miscellaneous
/-"-N FUNCTION
INSTRUMENT RELAY
&\ — /
SQUARE ROOT
z ADD OR TOTALISE
A SUBTRACT
+ BIAS
X INTEGRAL FUNCTION
^ ^ v RATIO
j RATIO PROPORTION FUNCTION
DOC.No.EG-DO-C-001 PAGE 28 OF 109 REV.O
Q 1 11 MiQrpllanpmic: f P n n f ' r n
OR GATE
^
AND GATE
LEVEL SWITCH
^ CHEMICAL/DIAPHRAGM SEAL
DOC.No.EG-DO-C-001 PAGE 29 OF 109 REV.O
FT
FLOW TRANSMITTER (VENTURI, DALL OR FLOW NOZZLE)
RESTRICTION ORIFICE
XXX "IN LINE" TYPE FLOW METERS (TARGET - TGT) (MAGNETIC FLOW -MAG)
FE
(CORIOLIS - COR) (THERMAL MASS FLOW -TMF)
(ULTRASONIC FLOW - ULT) (VORTEX FLOW - VOR)
TURBINE METER
AG - U G ABOVEGROUND/UNDER
BLIND FLANGE (BOLTED) GROUND DEMARCATION
) INSULATION AND
INSULATING FLANGE (i ELECTRICAL TRACING
ET
i INSULATION.
REMOVABLE SPOOL _D (e.g. PERSONNEL PROTECTION)
PP
-0 WELD CAP
1 SPECTACLE BLIND (OPEN)
HAMMER/PADDLE
HZ SCREW CAP BLIND OR SPADE
6"x4"
-o CONCENTRIC REDUCER
•V Y-TYPE STRAINER
0 INSTRUMENT FILTER
2% LINE ( 2 % SLOPE MINIMUM)
_|WW|_
SIGHT GLASS HAAAAT
EXPANSION BELLOWS
TIE-IN NUMBER
(XXX TIE-IN NUMBER) V VENDOR TIE-IN POINT
(YYY PLANT NUMBER)
PULSATION DAMPER
o DUPLEX STRAINER
CONE TYPE
T-TYPE STRAINER (TEMP.) STRAINER (TEMP.)
-©-►
/ \
BLOWER INLET SILENCER NEW PROCESS LINE
DISTRIBUTOR/SPRAY
"A A A" FUTURE LINE
NOZZLE
UTILITY STATION
w A N W-WATER, A-AIR, SAMPLE CONNECTION
N-NITROGEN
DF-DRINKING FOUNTAIN,
DF SS-SAFETY SHOWER VESSEL INSULATOR
EW-EYE WASH
TUNDISH
DOC.No.EG-DO-C-001 PAGE 32 OF 109 REV.O
^
ANGLE VALVE t%\ 3-WAY VALVE
EQUALISING VALVE
CHOKE VALVE
% ON MAIN BODY
NC
8.1.19 Equipment
a) Vessels
r >
^ ^
SCRAPER LAUNCHER/RECEIVER
TRAY TOWER PACKED COLUMN
b) Filters
Q\ Tanks
d) Heat Exchangers
ufru \/
TT
xy [61 IX
GENERAL
T
DOUBLE PIPE PLATE HEAT SHELL & TUBE
EXCHANGER(PFD) EXCHANGER EXCHANGER EXCHANGER
^ ^
M
KETTLE TYPE ELECTRIC AIR COOLER AIR COOLER
EXCHANGER HEATER (INDUCED DRAFT) (FORCED DRAFT)
//////////D A A
3)
M □= □=
AIR COOLER HEATER HEATER
(WITH AUTOMATIC LOUVERS) (DIRECT FIRED) (INDIRECT FIRED)
e) Pumps
H
■ &
T T
r-tl
\k
CENTRIFUGAL PUMP RECIPROCATING PUMP SUBMERSIBLE PUMP
(MOTOR DRIVEN) (M DTOR DRIVEN) (MOTOR DRIVEN)
-0= =IH
INLINE CENTRIFUGAL INLINE CENTRIFUGAL BARREL PUMP
PUMP (MOTOR DRIVEN) PUMP (TURBINE DRIVEN) (AIR DRIVEN)
DOC.No.EG-DO-C-001 PAGE 34 OF 109 REV.O
e) Pumps (Cont'd)
o
^ o
M r
M
LIQUID RING, SLIDING
VANE VACUUM PUMP GEAR PUMP ROTARY SCREW PUMP
(MOTOR DRIVEN) (MOTOR DRIVEN) (MOTOR DRIVEN)
0 0 s
M
f) Mixing Devices
_Q
ii=T
o b
CHEMICAL LOADING PUMP
MIXER/AGITATOR (AIR DRIVEN)
CENTRIFUGAL
COMPRESSOR
(MOTOR DRIVEN)
M BLOWER/FAN
(MOTOR DRIVEN)
IMI
CENTRIFUGAL
COMPRESSOR (WITH EJECTOR/EDUCTOR
GEAR AND TURBINE)
CENTRIFUGAL RECIPROCATING
m^y^j COMPRESSOR
(WITH INTERSTAGE [M>
1 I i t COMPRESSOR
(MOTOR DRIVEN WITH
COOLING) INTERSTAGE COOLING)
i 1 SCREW
COMPRESSOR
(MOTOR DRIVEN)
h) Drivers
A PNEUMATIC MOTOR
E TURBINE
GE GAS ENGINE
DOC.No.EG-DO-C-001 PAGE 35 OF 109 REV.O
j) p Qt TD A h h r o \ / i n f i o n ^
EL ELEVATION MW MANWAY
NLL NORMAL LIQUID LEVEL SSLS SEQUENCING AND SHUTDOWN LOGIC SYSTEM
VDU VISUAL DISPLAY UNIT SCADA SUPERVISORY CONTROL & DATA ACCUSATION
DOC.No.EG-DO-C-001 PAGE 37 OF 109 REV.O
A ANALYSIS ALARM
D DENSITY OR DIFFERENTIAL
SPECIFIC GRAVITY
R RADIATION RECORD
OR PRINT
T TEMPERATURE TRANSMIT
DRIVER, ACTUATOR OR
Z POSITION DIMENSION Z AXIS
UNCLASSIFIED CONTROL
DOC.No.EG-DO-C-001 PAGE 38 OF 109 REV.O
M
MOTOR OPERATED VALVE
HAND CONTROL VALVE (BALL) LOCALLY OPERATED
i/p
CONTROL VALVE WITH
2-WAY SOLENOID VALVE
cfe
DIAPHRAGM ACTUATOR AND
(ENERGISE TO OPEN) ATTACHED SIGNAL CONVERTER.
TIME DELAY
XX SECONDS
2-WAY SOLENOID WITH PRESSURE-REDUCING
TIME DELAY TRIP REGULATOR WITH EXTERNAL
& MANUAL RESET PRESSURE TAP
{Xi
R 1 70 T n c l r i i m p n l - \/al\/<=»Q f n r P ft TD fPnnl-'rH
i©
RUPTURE DISC (VACUUM
BREAKER)
DOC.No.EG-DO-C-001 PAGE 40 OF 109 REV.O
SINGLE INST
PRESSURE
INSTRUMENTS
df)~—>
MULTIPLE
PRESSURE INST
3/4"
' 1/2"
3/4"
©--- -i
PG
INSTRUMENTS
\ PIPING Y3/4" }1/2"
i 1 e -i
PIPING ^ INST
2"
LEVEL M X MIXF
2"
LT LT
-t "*
PIPING. INST
1/2"
FT ■-e
FLOW 1/2" ■T?
TU
TEMPERATURE
TEMPERATURE
DOC.No.EG-DO-C-001 PAGE 41 OF 109 REV.O
VENT
Yl/2"
HMh Htxh
LEVEL SWITCH —-?
-i
2" HXh
H X INST
PIPING INST A 3 / 4 "
DRAIN PIPING
VENT
2"
i/a"
HX>|H
LEVEL GAUGE
Hx-
2"
1XI> li- IX-
INST
PIPING I INST.
3/4' X_Ef PIPING
DRAIN
VENT
1/2"
2"
IIXI-
Hx-
LEVEL CONTROLLER
OR 2
©■• ■T>
PRESSURE
LEVEL FLOW
NC NC
NOTES:
b. TYPICAL LEVEL BRIDLE SHOWING ISOLATION VALVES, VENTS & DRAINS. ALL
DETAILS TO BE MODIFIED TO MATCH TO RELEVANT PIPING SPECIFICATION.
LINE CLASS VALVES ARE INDICATED, INSTRUMENT VALVES ARE NOT SHOWN.
3. SHOW BALL VALVE FOR HYDROCARBON SERVICE. SHOW GATE VALVE FOR
NON-HYDROCARBON SERVICE.
DOC.No.EG-DO-C-001 PAGE 43 OF 109 REV.O
2"
Xh
—Xh
VESSEL
OR \x- —Xh
TANK 4"
VESSEL /**\
—Xh OR
TANK
3/4"
—Xh
DRAIN I 1/2"
wx-
DRAIN _
O
** . IT
y////////A//////// - LS
* INSTRUMENT CONNECTION 9 2" - LG
X]—-TOD]
A. LEVEL GAUGE (LG) : 1" 4\xt
NC ! '
B. LT (D/P CELL TYPE) : 3/4"
C. LT (DISPLACEMENT TYPE) : 2"
D. LS (EXTERNAL TYPE) : 1"
(INSTRUMENT VALVES ARE NOT SHOWN)
2"
Xh
Xh
VESSEL
^**\
OR
TANK VESSEL
OR
TANK
2"
\x-
DRAIN Y 1/2" \x
* INSTRUMENT CONNECTION r>
A. LEVEL GAUGE (LG) : 1" * * _ I T
B. LT (D/P CELL TYPE) : 3/4" NC I
C. LT (DISPLACEMENT TYPE) : 2" 77777777777777777/ - LS
D. LS (EXTERNAL TYPE) : 1" ?2" - LG
(INSTRUMENT VALVES ARE NOT SHOWN)
DOC.No.EG-DO-C-001 PAGE 44 OF 109 REV.O
^AL> fALb
V J
S/D
S/D
AI -^H^khH^kh^
X VENT
X
//' //
& ^
TO ^ALb
V M
S/D
AI - ^ ^ ^ T ^ " ^
1
1H- S/D
VENT
/ / //' E ^ ^
a
* CHANGE SYMBOL FOR DCS BASED LOGIC TO SUIT
NOTE:
1. SINGLE OR DOUBLE ACTING ACTUATOR TO BE SELECTED IN ACCORDANCE WITH
REQUIRED VALVE OPENING/CLOSING SPEED AND TORQUE.
DOC.No.EG-DO-C-001 PAGE 45 OF 109 REV.O
AVAILABLE CLOSE
u n HS
^OOCAU baxByl kxxxAi/l AVAILABLE
NOTE 1
K>^
XXX = LOOP NUMBER
NOTES:
1. FOR PROCESS SHUTDOWN LOGIC REFER TO CAUSE AND EFFECT MATRIX
2. ALL BLOWDOWN VALVE & ESDVS TO BE PROVIDED WITH A DEDICATED INSTRUMENT
AIR ACCUMULATOR.
DOC.No.EG-DO-C-001 PAGE 46 OF 109 REV.O
HS
XXXC1
\ o I /
-■Or
i
CLOSE OPEN
zicN Kzio
NOTE 1
K>
XXX = LOOP NUMBER
NOTES:
1. FOR PROCESS SHUTDOWN LOGIC REFER TO CAUSE AND EFFECT MATRIX
2. ALL BLOWDOWN VALVE & ESDVS TO BE PROVIDED WITH A DEDICATED INSTRUMENT
AIR ACCUMULATOR.
DOC.No.EG-DO-C-001 PAGE 47 OF 109 REV.O
:_yt_j ' UL
<XXD/ \xxXCy
/* \/-~ TRIPPED
/ UL
\
o I /
NOTE 3
IMU I t J ,
<XXD/ \|xxc7
TRIPPED
l\\J I t J ,
^HS^ LytJ C^
^xxxci/j 5 ^ 5 \ v°2V
" " V TRIPPED
I UL ^
/
\ F = =^
XXXB
NOTE 1
MGh
NOTES:
1. FOR PROCESS SHUTDOWN LOGIC REFER TO CAUSE AND EFFECT MATRIX
2. ALL BLOWDOWN VALVE & ESDVS TO BE PROVIDED WITH A DEDICATED INSTRUMENT
AIR ACCUMULATOR.
DOC.No.EG-DO-C-001 PAGE 50 OF 109 REV.O
AVAILABLE CLOSE
ULN KHS
PROCESS
INTERRUPT
V " — y
UL
\\\J I to,
/ HS
vXXXAy
CLOSE K H S^
txxxcX
OPEN
—*!
STOP
\XXXE/
CLOSE/^s^
NOTE 1
\XXXF/
LOCAL/OFF
REMOTE fHS
r
NOTE:
1. FOR PROCESS SHUTDOWN LOGIC REFER TO CAUSE AND EFFECT MATRIX
DOC.No.EG-DO-C-001 PAGE 52 OF 109 REV.O
LOCAL/^UL
REMOTE
CLOSE
LXXXXBJ kxXXX^
NOTES:
1. DURING REMOTE OPERATION CONTINUOUS DEPRESSING OF OPEN OR CLOSE SOFT
PUSH BUTTON ON DCS OPERATOR INTERFACE CAUSE VALVE TO TRAVEL. RELEASE
OF SOFT PUSH BUTTON LEVELS VALVE IN LAST POSITION.
2. TYPE OF VALVE SHALL BE AS SHOWN ON RESPECTIVE P&ID.
DOC.No.EG-DO-C-001 PAGE 54 OF 109 REV.O
NOTE 2
RUNNING I DUTY/STANDBY
HS
o—o—o- ISELECT
<xx>
STOPPED MOTOR
START
o
AVAILABLE I
o
NOTE 1 I
o
REMOTE I
o
I
o
I
FAULT o
I STOP
o—o—o- r -o—o—o—o—
kmxM
EMERG. STOP o NOTE 1
LOGIC HARDWARE
(ESD, SSLS, OR DCS)
(x>+
i
RELAY
INTERFACE
PANEL
fr MCC
4 MOTOR
STARTER
SUBSTATION NOTES 4,5
MOTOR
NOTE 3 LOCAL CONTROL
PANEL OR STATION
(HS\
WXXD)
EMRGENCY
STOP
NOTE 1
NOTE 5
LOCAL/OFF/REMOTE STOP START
INUI fcb:
1. XXXX = LOOP NUMBER.
2. DUTY SELECT & REMOTE/LOCAL SWITCHES REQUIRED ONLY WHEN AUTO-START OF
STAND BY MOTOR IS SHOWN ON RESPECTIVE P&ID DIAGRAM
3. EACH MOTOR DOES NOT NECESSARILY NEED ALL THESE FEATURES, AND MAY REQUIRE
OTHERS. REFER ELECTRICAL DWGS. AND P&ID FOR SPECIFIC MOTOR APPLICATION DETAILS
AS WELL AS BUT NOT LIMITED TO KOC-I-001 SECTION 9.10,015-JH-1911 SECTION 5,8
4. EITHER A MOTOR LOCAL CONTROL PANEL OR A MOTOR LOCAL PUSH BUTTON STATION
MAY BE IMPLEMENTED.
5. MOTOR STATUS INFORMATION SHALL BE HARDWIRED VIA THE RELAY INTERFACE
PANEL TO THE ESD/SSLS.
DOC.No.EG-DO-C-001 PAGE 55 OF 109 REV.O
8.1.27 Sample Connection Arrangements
8.1.27.a Stream : Gas (Note-1)
■■»,
3/4" C
W
3/4"
BY LAB.
NOTE:
1. SAMPLE POINTS SHALL BE EASILY ACCESSIBLE SAMPLE LINES SHALL BE AS
SHORT AS POSSIBLE.
DOC.No.EG-DO-C-001 PAGE 56 OF 109 REV.O
8.1.27-b Stream : Oil, Water (Note-1)
DETAIL P & I D REPRESENTATION
O
3/4"
3/4"
3/4"Xl/2"
1/2" i
3/4"
3/4"Xl/2"
f 1/2"
NOTE:
1. SAMPLE POINTS SHALL BE EASILY ACCESSIBLE SAMPLE LINES SHALL BE AS
SHORT AS POSSIBLE.
DOC.No.EG-DO-C-001 PAGE 57 OF 109 REV.O
8.1.27.d Stream : Oil
DETAIL P & I D REPRESENTATION
] 3/4"
3/4" 1/2"
i*\ O D#i
3/4"xl/2"
i
UJ
1/2" DO
<
in
U
NOTES:
1. SAMPLE POINTS SHALL BE EASILY ACCESSIBLE SAMPLE LINES SHALL BE AS
SHORT AS POSSIBLE.
2. THE PIPING MATERIAL CLASSES FOR ALL SAMPLE PIPE FITTINGS, VALVES AND
BRANCHES SHALL BE SAME MATERIAL CLASS AS THE SAMPLE LINE ORIGINATES
UNLESS OTHER WISE INDICATED IN THE DRAWING.
1/2" PIPE
FLOW
45° BEVEL
8.1.28.D Anti-Form
1 PIPE
l"xl/2" -Q^ " 1/2" PIPE
2" PIPE 2 " x l / 2 " REDUCED
SLIP-ON FLANGE
FLOW
45° BEVEL
3" PIPE
FLOW
45° BEVEL
DOC.No.EG-DO-C-001 PAGE 59 OF 109 REV.O
TANK OR VESSEL
2" FLANGE
1" OR 3/4'
PROTECTIVE COVER
NUT CC-XXX
SOLID PLUG
PRIMARY PACKING
COUPON HOLDER
FLOW
2"x3" STRIP CORROSION COUPON
DOC.No.EG-DO-C-001 PAGE 60 OF 109 REV.O
8.1.30 Typical Pump Casing Vents & Drains On Suction Discharge Lines &
Base Plate Drains
I BP|
■ 150#
3/4" Y N C ' 300#
\—cy -e
2"
3/4"
-tX"
NC
2"YNC
'300#
-150#
[DDI
-^
-DM
3/4"
rt
<tx-
NC
2
"XNC 600#
150#
DOC.No.EG-DO-C-001 PAGE 61 OF 109 REV.O
3"INLET FLANGE
CONNECTION
GRADE
12"-WF-XXXX-Q35A
FIRE WATER RING MAIN
CONCRETE FOUNDATION
GRADE
12"-WF-XXXX-Q15A
FROM 12" FIRE WATER TANK
DOC.No.EG-DO-C-001 PAGE 62 OF 109 REV.O
e-H Gt-S
r
PLAN
90° ELBOW
ELEVATION
±
PLAN C(>H OEM
45° ELBOW
ELEVATION
i
(
I
PLAN h \C\ 1 &->SHH
TEE b— fr-jHrtH
ELEVATION h o ±
PLAN h—K^H &—JHBm
LATERAL >
ELEVATION
h—H ^U \ )
CONCENTRIC L ^ L>
(PLAN/ELE.) TBE=THREAD BOTH END PBE=PLAIN BOTH END
SWAGE
ECCENTRIC
(ELEVATION) TBE=THREAD BOTH END PBE=PLAIN BOTH END
PLAN/
UNION ELEVATION 0 1 1—3 &—nln—s
PLAN/
FULL COUPLING
ELEVATION
h— —9 &—~ "—S
PLUG ELEVATION
^ ^
CAP ELEVATION E 3 E S
DOC.No.EG-DO-C-001 PAGE 63 OF 109 REV.O
PLAN G-
90° ELBOW
ELEVATION
PLAN
45° ELBOW
ELEVATION
PLAN ■h-H-H-f
TEE
ELEVATION
PLAN /
CAP
ELEVATION
SLIP-ON PLAN /
FLANGE ELEVATION h ^ = ^
WELD NECK
FLANGE
PLAN /
ELEVATION r=^
BLIND PLAN /
FLANGE ELEVATION * 3-
ORIFICE PLAN /
FLANGE ELEVATION
DOC.No.EG-DO-C-001 PAGE 64 OF 109 REV.O
STUB IN
-E3£I3
STUB IN WITH
REINFORCING PAD
-EiMza
WELD SADDLE A
SPLIT TEE X
WELDOLET
_Q_
ez+3
INSULATED PIPE 4=1
H. or—x
INSULATING FLANGE
-E 3-
4-WAY
SUCTION COLLECTION HEAD 4
4
4,
EXPANSION BELLOWS
-E i 3-
HAMMER/ PADDLE
BLIND OR SPADE 4^ td&
RING SPACER
b-HD ■E
3-
Y-TYPE STRAINER
WITH GATE VALVE
AND PLUG v
fe
<^NC NC
^
T-TYPE STRAINER
H XJIL. E*-;-3&
DOC.No.EG-DO-C-001 PAGE 66 OF 109 REV.O
T-TYPE STRAINER
(TEMPORARY)
2
^^
H3iE-T-E|&
CONICAL TYPE
STRAINER (TEMPORARY) -F^fF^gfp^
TUNDISH WITH
SAND COVER
TUNDISH
8.2.2 Valves
TYPE OF VALVES FLANGED SCREWED SOCKET
(?)
ELEVATION END ELEVATION END ELEVATION END
w PLAN
2Hl
PLAN
BALL VALVE
PLAN -w- -@- M @
ELEVATION END
ELEVATION END
N ELEVATION END
PLAN PLAN
CHECK VALVE
KD © N ® PLAN
ELEVATION END
]S[ ®
ELEVATION END
ELEVATION END
PLAN
CONTROL VALVE
PLAN
m © IXl
ELEVATION END ELEVATION END
31 83 SI
PLAN PLAN PLAN
RELIEF VALVE
k b k
ELEVATION END ELEVATION END ELEVATION END
PLAN PLAN
<m
PLAN
ANGLE VALVE
@
% % %
ELEVATION END ELEVATION END ELEVATION END
PLUG VALVE
M
PLAN
BUTTERFLY VALVE
N ©
ELEVATION END
BA1
PLAN PLAN PLAN
DIAPHRAGM VALVE
V^ © ®
ELEVATION END ELEVATION END ELEVATION END
CHOKE VALVE
ffigffl
PLAN PLAN PLAN
3-WAY VALVE
MI ]®
ELEVATION END ELEVATION END ELEVATION END
B2H K
ELEVATION END ELEVATION END ELEVATION END
DOC.No.EG-DO-C-001 PAGE 69 OF 109 REV.O
OPERATORS
PLAN
GEAR - TYPE 1
ELEVATION END
PLAN
GEAR - TYPE 2
h>.
ELEVATION END
PLAN
WRENCH
ELEVATION
®
END
PLAN
MOTOR
M M
®
ELEVATION END
PLAN
ACTUATOR
®
ELEVATION END
DOC.No.EG-DO-C-001 PAGE 70 OF 109 REV.O
+
t -X-
ANCHOR
-X-
GUIDE
I -X-
SHOE
I -X-
H
HANGER
fy JJSJJS/J/JJJSJl-
JIS J J S/J
SH
IT T -X-
SPRING HANGER
70
DS
-X-
DUMMY SUPPORT
-X-
ss
f////////y///i-r '),,,it
SPRING SUPPORT
DOC.No.EG-DO-C-001 PAGE 71 OF 109 REV.O
AMERICAN
API COL COLUMN
PETROLEUM INSTITUTE
AMERICAN SOCIETY OF
ASME CHOP CHAIN WHEEL OPERATED
MECHANICAL ENGINEERS
AMERICAN NATIONAL CONNECTION
ANSI
STANDARDS INSTITUTE
CONN
AMERICAN WATER CONTINUE/CONTINUATION
AWWA WORKS ASSOCIATION
CO NT
MANUFACTURE'S
FTG FITTING MSS
STANDARD SOCIETY
H
2 S HYDROGEN SULFIDE PE PLAIN END
LEGEND DESCRIPTION
:\ GL_
GROUND LEVEL
FFL
FINISHED FLOOR LEVEL
SECTION
SLOPE
PLTF.
PLATFORM ELEVATION
^
FIELD WELD
TIE-IN POINT
(XXX TIE-IN NUMBER)
(YYY PLANT NUMBER)
EXISTING — — NEW
DOC.No.EG-DO-C-001 PAGE 75 OF 109 REV.O
8.5.1 Power
4 PIN 3 0 60A
11 1 1 RING MAIN UNIT (RMU) A SWITCH SOCKET OUTLET
15A, 1 0 , SHUTTERED
c 1 SWITCHBOARD A WITH PILOT LAMP
L
^ 1 DISTRIBUTION BOARD
H 13A, 1 GANG UNSWITCHED
SOCKET OUTLET IP56
(v VOLTMETER BUSBAR
H **
£ EXHAUST FAN ± EARTH
DOC.No.EG-DO-C-001 PAGE 76 OF 109 REV.O
THERMAL OVERLOAD
H RELAY
\ 1 CABLE CAPPED END
n FEEDER PILLAR
® POWER CABLE
REFERENCE NUMBER
CONTROL CABLE
JB JUNCTION BOX
<£> REFERENCE NUMBER
7
HEATER m FEEDER
REFERENCE NUMBER
EARTHING CABLE
111111
NEW CATHODIC
PROTECTION GROUND BED 0 REFERENCE NUMBER
WIRING CIRCUIT , SLASH
EXISTING CATHODIC //// INDICATES No. OF WIRES
PROTECTION ANODE BED
INCLUDE NEUTRAL
LPl-1,2,3,4 CIRCUIT HOME RUN,INDICATES
Y
A Y
A NEW OVERHEAD LINE ////// ^ No. OF CIRCUIT + NEUTRAL
//////
EXISTING CABLE TO BE
NEW POWER/CONTROL CABLE ////////
REMOVED/DISCONNECTED
EXISTING POWER/CONTROL SPARE CORE
3 TAPED AND COILED
CABLE
i NORMALLY OPEN
X CIRCUIT BREAKER o o CONTACT
i
n n
NORMALLY CLOSED
MCCB
<: CONTACT
J NORMALLY OPEN
7 MCB O 0 CONTACT-MANUAL RESET
NORMALLY CLOSED
I FUSE ~l CONTACT-MANUAL RESET
DOC.No.EG-DO-C-001 PAGE 77 OF 109 REV.O
Q c 9 C r h o m a f i r fL Q i n n l o I i n o h i a n r a m f f ^ r r H H ^
7 FUSE SWITCH
0 O
PUSH BUTTON NORMALLY
OPEN CONTACT
PUSH BUTTON NORMALLY
SWITCHFUSE n T r>
\ CLOSED CONTACT
V LEVEL SWITCH
1 VOLTAGE TRANSFORMER
DIRECT ON LINE
H STARTER *
VOLTAGE REGULATOR
~v TEMPERATURE SWITCH
^
CONTACTOR
^
FLOW SWITCH £ CURRENT TRANSFORMER
_L
® AMMETER
T
CAPACITOR
o
SINGLE POLE 2 POSITION
© MOTOR o—o
CHANGE OVER SWITCH
SINGLE POLE 3 POSITION
RECTIFIER OR BATTERY JMIII- BATTERY
$ CHARGER
L LOCAL/REMOTE
|VSD| VARIABLE SPEED DRIVE A SELECTOR SWITCH
S OFFLOAD ISOLATOR
3 : NUMBER OF POLE s ONLOAD ISOLATOR (AC23)
a ELECTRO-MECHANICAL
INTERLOCK
j$j STATIC SWITCH
8.5.3 Lighting
SINGLE TUBE FLUORESCENT STANCHION MOUNTED
~ ~ o-O
LAMP FIXTURE (1200mm LONG) LIGHTING FIXTURE
a BULKHEAD LIGHTING
FIXTURE 200W LAMP w EMERGENCY LIGHTING UNIT
SELF-CONTAINED BATTERY PACK
a BULKHEAD LIGHTING
FIXTURE 100W LAMP
3
WALL WASH RECESSED
MOUNTED LIGHTING FIXTURE
EMERGENCY EXIT SIGN
Nxn4
FLAMEPROOF LUMINAIRE ® DOWNLIGHT LIGHTING FIXTURE
e SURFACE MOUNTED
EMERGENCY LIGHTING ^
TRIPLE POLE
ONE WAY SWITCH
8.5.4 Telecommunication
TELEPHONE
► DUAL LAN OUTLET |TDB|
DISTRIBUTION BOARD
El
FAP
FIRE ALARM PANEL
o SMOKE DETEaOR
(IONIZATION TYPE)
*
FLASHER MOUNTED ON THE ROOF © FLAMEPROOF
8.5.6 Earthing
EARTHING ROD WITH WELDED
500mm 2 EARTHING CABLE
CONNECTION
EARTHING TEST WELL FOR
120mm 2 EARTHING CABLE
PAVED AREAS
EARTHING TEST WELL FOR
9 5 m m 2 EARTHING CABLE
UNPAVED AREAS
8.5.7 Building
(HIGHER) ^ (LOWER) CONDUIT RUN CHANGE IN INFLOOR RACEWAYS TAG No. &
ELEVATION MATERIAL ITEM No.
DOC.No.EG-DO-C-001 PAGE 80 OF 109 REV.O
© TEMPERATURE RELAY
© INVERSE DEFINITE MINIMUM TIME
EARTHFAULT RELAY
(26w)
WINDING TEMPERATURE INDICATOR
WITH ALARM &TRIP CONTACTS
© BUCHHOLZ GAS SURGE RELAY
© EXCITATION RELAY
© A-ANALOGUE CONSTANT
(SON)
INSTANTANEOUS EARTH FAULT
RELAY
© DEFINITE TIME DELAY REVERSE
POWER RELAY
©
INVERSE DEFINITE MINIMUM TIME
OVER CURRENT RELAY WITH VOLTAGE
© INTERTRIP SEND RELAY
RESTRAINT
DEFINITE TIME DELAY OVER © MOTOR STALLING RELAY
© VOLTAGE RELAY
(PQM)
POWER QUALITY
AND MAXIMUM DEMAND
($0$) DEFINITE TIME DELAY EARTH
\S2j FAULT RELAY (kWh) KILOWATT HOUR METER
^—^
® INVERSE DEFINITE MINIMUM TIME
OVER CURRENT RELAY WAR) KILOVOLT AMPERE REACTIVE
METER
INVERSE DEFINITE MINIMUM TIME
® STANDBY EARTH FAULT RELAY © POWER FACTOR METER
DOC.No.EG-DO-C-001 PAGE 81 OF 109 REV.O
8.7.1 General
SECTION TITLE
SECTION TOP - SECTION IDENTIFICATION LETTER
(SCALE TO BE SHOWN BELOW) \XX"X-XX BOT - DRAWING ON WHICH SECTION IS SHOWN
(WHEREAS A REPRESENT LETTER)
DETAIL INDICATION
DETAIL n TOP - DETAIL IDENTIFICATION NUMBER
(SCALE TO BE SHOWN BELOW) \XX"X-XX BOT - DRAWING ON WHICH DETAIL SECTION IS SHOWN
(WHEREAS n REPRESENT NUMBER)
REFRIGERATOR
DOUBLE DOOR
UNEQUAL WIDTH LAUNDRY
LJO
SINGLE DOOR URINAL
□ GT GULLY TRAP
VP
VENT PIPE
DOC.No.EG-DO-C-001 PAGE 85 OF 109 REV.O
8.7.7 Miscellaneous
4v
Vxx-x
XX
EXTERNAL ELEVATION TITLE
TOP- ELEVATION IDENTIFICATION LETTER
BOT- DRAWING ON WHICH ELEVATION IS SHOWN
ROOM NUMBER
(WHEREAS n REPRESENT NUMBER)
SUSPENDED ACOUSTIC
TILES 600mm x 600mm
LAY-IN GRID UNLESS NOTED OTHERWISE
DOC.No.EG-DO-C-001 PAGE 86 OF 109 REV.O
CB CATCH BASIN
AMERICAN SOCIETY FOR
ASTM
TESTING AND MATERIALS C/B CONCRETE BLOCKS
Cu COPPER EA EACH
PL PLATE RM ROOM
SURP SURPLUS
UNPLASTICIZED POLYVINYL
UPVC
CHLORIDE
SUSP SUSPENDED
SUPPLY OUTLET.CEILING,
20 m INCLINED DROP (D), IN
ROUND (TYPE AS SPECIFIED)
700 CFM DIRECTION OF AIR FLOW
INDICATE FLOW DIRECTION
mr 12 x12 >
700 CFM
SUPPLY OUTLET.CEILING,
SQUARE (TYPE AS SPECIFIED)
INDICATE FLOW DIRECTION f=n-f CONNECT NEW DUCT
TO EXISTING DUCT
W
W
30 X 12
I
12 X30
DUCT SECTION
(SUPPLY)
LIMIT OF DEMOLITION
W D W D
W
W
DUCT SECTION
(EXHAUST OR RETURN) FLEXIBLE DUCT
30 X 12 12 X30
W D W D
DIRECTION OF FLOW
45°-ftURETURN
DOC.No.EG-DO-C-001 PAGE 94 OF 109 REV.O
(COWL)
SPLITTER DAMPER
GOOSENECK HOOD
VOLUME DAMPER
i
cp rsiPiri—^ FAN & MOTOR WITH
t
i
VENTILATING UNIT
AP
~y
D
AD"
ACCESS DOOR (AD)
ACCESS PANEL (AP) 3 (TYPE AS SPECIFIED)
DOC.No.EG-DO-C-001 PAGE 95 OF 109 REV.O
\ I / UNIT HEATER
(CENTRIFUGAL FAN) PLAN
i }
AIR CONDITIONING
UNIT. LETTER
INDICATES UNIT SIZE
AIR COOLED
CONDENSING UNIT(CU)
CU (FOR PACKAGE TYPE-
LOUVER & SCREEN AIR HANDLING UNIT)
-V
FRESH AIR INTAKE SAND
POWER OR GRAVITY ROOF LOUVER WITH
VENTILATOR -EXHAUST 4" THICK METALLIC
(ERV) CLEANABLE FILTER.VCD &
WIRE MESH WITH END CAP
,_,
POWER OR GRAVITY ROOF
VENTILATOR -INTAKE
(SRV) LJ
X h EXHAUST FAN AIR LOUVER
MOTOR TYPE
IZZI
POWER OR GRAVITY ROOF
VENTILATOR -LOUVERED
m ELECTRIC DUCT HEATER
h
20 x12 SG
SUPPLY GRILLE (SG)
m
j\
FRESH AIR INTAKE
LOUVER WITH FILTER
& VOLUME CONTROL
DAMPER(VCD)
700 CFM
20 x12 RG
700 CFM
RETURN (RG) OR EXHAUST
(EG) GRILLE(NOTE AT FLR
OR GLG)
=£ INTAKE LOUVER
THERMOSTAT
20 x12 SR SUPPLY REGISTER (SR)
V (A GRILLE + INTEGRAL
700 CFM VOLUME CONTROL) (DO) DUCT DAMPER
20x12 GR
"VocTcFM
EXHAUST OR RETURN AIR
INLET CEILING
(INDICATE TYPE)
© FIRE DAMPER
SMOKE DAMPER
EXHAUST FAN (EF)
PROPELLER TYPE
WALL MOUNTED SPLITTER DAMPER
*
DOC.No.EG-DO-C-001 PAGE 96 OF 109 REV.O
DEGREE CELSIUS /
AS AIR SEPARATOR °C CENTIGRADE
AUTOMATIC TEMPERATURE
ATC DUC DOOR UNDER CUT
CONTROL
K U W A I T O I L CO. (K.S.C.)
ENGINEERING GROUP
DESIGN TEAM
PRINT ROOM
DRAWING NUMBER RESERVATION REQUEST
Project Title:
i —
Issued
Chkd. Card
Snr. Operator Print Room: Registered
Collected
DOC.No.EG-DO-C-001 PAGE 99 OF 109 REV.O
Project Title
Draughtsman
Sr. No. Drawing No. Drawing Title
Name
Signature.
PRINT ROOM
H I S T O R Y (To be attached with Revision/Amendment Details)
PLEASE WRITE BLOCK LETTERS OR PRINT IN BLACK & WHITE, THE DETAILS OF LAST REVISION.
2 Rev
3 Rev
4 Rev
#UL^
5 Rev
6 Rev
7 Rev
8 Rev
9 Rev
Revised By Signature
DOC.No.EG-DO-C-001 PAGE 101 OF 109 REV.O
p&- ^
Req U e S ted Re
Actions Name Signature Tel. No. D a t e ^|eed
REQUESTED BY
AUTHORIZED BY
APPROVED BY
COLLECTED BY
— DIVIDING LINE
3/3 2/3
SECT. No.
THESE PORTIONS TO BE
FILMED AS OVERLAPS (100mm. ON DWG.)
DOC.No.EG-DO-C-001 PAGE 103 OF 109 REV.O
+1.6mm
50.8 mm-o
cutting marks
Film edge
Card aperture
Adhesive
film aperture
Centre mark
Scale
LOCATION OF MARKS AND SCALE
Notes
a. The center marks are to appear on the top and bottom of the finished film.
The original thickness of the line shall be 0.5 to 1.0 mm and as short as
practicable and should be effective in preventing cuttings errors.
c. The scale shall be positioned under the lower left corner of the drawing
and shall be 200 mm. in length.
DOC.No.EG-DO-C-001 PAGE 104 OF 109 REV.O
Density shall be 0.9 to 1.1 fills properly exposed and developed according
to standard procedure. The film based on subsequent, must be clear
and colourless.
c) Film Mounting
When mounting the film onto the aperture card, the center line of the
film and the center line of the aperture must be carefully aligned and
tolerance in this case shall be 0.5 mm.
r "\
NEGATIVE
LOCATION
V J
e) Contractor Drawing Number
ALL FILLING - IN SHALL BE DONE BY USING CAPITAL LETTERS AND BLACK COLOR.
DOC.No.EG-DO-C-001 PAGE 105 OF 109 REV.O
DRAWING LIST
PROJECT TITLE
CONTRACTOR NAME
P^^
AS BUILT
KOC APPROVAL
NAME :
DESIGNATION :
GROUP/TEAM :
SIGNATURE :
DATE :
The "As Built Drawing Approval Stamp" shall be shown above the Title Panel
and duly signed by KOC Controlling Team Senior Engineer . The Stamp should
furnish all the details as shown above.
All contractor drawing shall have the standardized As Built drawing title panel as
shown below . Electronic files in Autocad format for AO , A l , A2 & A3 sizes are
available in KOC Print/Record Room for Contractor use. Refer Drawing number as
mentioned below :-
CONTRACTOR REVISION
KOC APPROVALS
DESIGNATION - GROUP / TEAM SIGNATURE DATE
CONTRACTOR NAME
LOGO CONTRACTOR ADDRESS
DRAWN DESIGNED CHECKED
APPROVED DATE SCALE
PROJECT TITLE
CONTRACT No.
DRAWN CHECKED APPR'D DATE
AREA / LOCATION / FACILITY
PROJECT TITLE
PROJECT TITLE
DRAWING TITLE
PROJ. No. DRAWING NUMBER
CONTRACTOR DRG. No REV. KOC DRG. No. REV.
xx/xxxx xxx-xx-xxx XXX-XX-XXX
SHEET OF SHEET __OF __
DOC.No.EG-DO-C-001 PAGE 109 OF 109 REV.O
1) Master Drawings
Master As-Built Drawings in Original size in Electronic format & Hard Copy.
2) Hard Copies
Hard copies on Transparent Polyester Film in Original Size from the plotter
in specified KOC format . Photocopy in any form is not acceptable.
3) Electronic File
Electronic File Names of CAD files shall be same as Drawing Number in Autocad
Version in use with KOC on Re-writable CD (Compact Disc) / DVD (Digital
Versatile Disc)
4) C o m m o n Drawing
Common Drawings for different facilities in one project should be
numbered as separate.
5) Graphic scale
Graphic Scale shall be provided on all scaled Drawings at the right hand side
of the drawings above the title panel.
6) Key Plan
Key Plan with the location plan shall be provided on all Layout Drawings
at the right hand side of the drawings above the Graphic Scale.
7) Colour
Light colours (like yellow) shall not be used on the drawing.
8) Modifications
All Modifications carried out during Construction / Installations shall be
indicated and detailed.
9) Vendor Drawings
Vendor Drawings will not be provided with KOC Drawing number . Vendor Drawings
shall be submitted to Controlling Teams only for onward submittal to Technical
Library for Records . Print room will not handle Vendor Drawings / Documentation.
10) Specification
Drawings deviated from the above Specification shall not be accepted.