Professional Documents
Culture Documents
UTAX CD 1218
UTAX CD 1222
TA DC 2118
TA DC 2218
TA DC 2222
TOPIC:
The part number of the key counter and the installation parts.
No. 1 No. 2
No. 3
1/1
Technical Bulletin UTAX CD 1118
UTAX CD 1218
UTAX CD 1222
TA DC 2118
TA DC 2218
TA DC 2222
TOPIC:
The firmware was upgraded as follows.
Content of Changes
1 Measures against “Memory full” was displayed if the Start key was pressed for scanning job after 390627 MAIN
JAM05 changing the function to (Copy) screen and setting original to the DP when
memory was nearly full. Then, if the function was changed to (Scan) and
returned to (Copy), “Memory full”, “Continue?” and “Cancel?” were displayed.
If “Continue” was selected, JAM05 occurred. Therefore, the following change
was made.
<Change>
Change of functions is prohibited when memory full is displayed.
2 Measures against Once changing to (Send) screen and sending data to PC when paper cassette 396067 MAIN
abnormal image when became empty during printing, abnormal image might be printed if copy was
paper cassette resumed by refilling papers. Therefore, this was corrected.
became empty during
printing
Example of
abnormal image
Paper feeding
direction
1/2
Only J CD 1218, CD 1222 / DC 2218, DC 2222
* The above is the plan at the present moment. / Please note that this is subject to change.
2/2
Technical Bulletin UTAX CD 1118
UTAX CD 1218
UTAX CD 1222
TA DC 2118
TA DC 2218
TA DC 2222
TOPIC:
The firmware was upgraded as follows.
Content of Changes
1 Measures against lock- The toner information detected while data was received during sleep mode 396921 PRI
up after sleep mode could not be processed and the data was not output wile “Waiting” was
displayed. Therefore, this was corrected.
2 New flash memory Change was made in order to support the flash memory of Numonyx which will PRI
device be used in the future.
* The above is the plan at the present moment. / Please note that this is subject to change.
1/1
Technical Bulletin UTAX CD 1118
UTAX CD 1218
UTAX CD 1222
TA DC 2118
TA DC 2218
TA DC 2222
TB 04 / Firmware Upgrade
SB-9250/M
Date: 11-01-2010
TOPIC:
The firmware was upgraded as follows.
Content of Changes
1 Measures against the The original on the DP may not be detected and not be fed from the DP, but the 423847 MAIN
failure to detect the platen may be scanned to copy in case copy is started with <Start> button when
copying original on the restarting from sleep mode. This is corrected.
DP
- This does not occur in case of restart from sleep by print job and manual
restart.
- This does not occur in FAX mode.
- This can be reset by power off/on.
<Change>
The DP connection information may be cleared (initialized) when restarting from
sleep mode. Therefore, the step to check the DP connection is added.
1/2
Classification Entire Stock Rework In-Field modification at next visit
In-Field modification by case No modification necessary
Field Measure: Please upgrade the firmware to the latest version when the phenomenon described
above arises.
Serial Nos. of Affected Machine: From the production in December, 2009 on*
* The above is the plan at the present moment. / Please note that this is subject to change.
2/2
Technical Bulletin UTAX CD 1118
UTAX CD 1218
UTAX CD 1222
TA DC 2118
TA DC 2218
TA DC 2222
TOPIC:
The torque limiter (No.1) is changed as below for preventing the abnormal noise.
According to the change, attention is required when replacing the torque limiter (No.1) at the paper feed
section (the paper feed section of the main machine or PF-420) and please refer to <Field Measure> below.
CONTENT OF CHANGES:
The torque limiter (No.1) and the shaft (No.2) in the paper feed section
B
Before After
Old No.1: 14mm parts as New No.1: 18mm parts as
external diameter external diameter
X
X
A
New No.2: Length of X section is 6.3mm
Old No.2 (Extended by 2mm toward the torque
: Length of X section is 4.3mm limiter.)
* Convex sections (X) are in two places of both sides of the shaft.
Matching condition: view from A of above figure Matching condition: view from B of above figure
X
* Convex section (X) of the old shaft (No.2) matches to * Convex section (X) of the new shaft (No.2) matches to
the U-shape notch section of the old torque limiter the bump at the inside diameter of the new torque limiter
(No.1). (No.1).
1/2
1) The insulation External diameter of the torque limiter (No.1) in the paper feed and the drive section is
changed from 14mm to 18mm.
2) Size of the convex section (X below) of the side of the shaft (No.2) that matches with the torque limiter
(No.1) at the paper feed section (the paper feed section of the main machine or PF-420) is extended by
2mm because the shape of the torque limiter (No.1) that receives convex section of the shaft (No.2) is
changed according to the above change 1).
3) According to the above change 1), 2), the assembly of the new torque limiter section (No.3) is registered
as the service parts to improve exchange of the torque limiter and the shaft in the paper feed section in
the field.
* At the paper feed section or PF 420, please use the set of the old parts or new parts that is combination of 1pce of the
torque limiter (No.1) and the shaft (No.2).
In 1pce of the torque limiter (No.1) at the drive section, no particular problem is expected.
*1: CD 1118, CD 1218, CD 1222 / DC 2118, DC 2218, DC 2222: 2pcs (each 1pce is used at the paper feed/drive section),
PF 420: 1pce
*2: Service Parts
*3: It is supply in the state to assemble the new torque limiter (No.1) at the paper feed section, the new shaft (No.2), and the
pulley (2AR07230), the holder (2C907250) that fixed to the shaft.
2/2
Technical Bulletin UTAX CD 1118
UTAX CD 1218
UTAX CD 1222
TA DC 2118
TA DC 2218
TA DC 2222
TOPIC:
The operation board (Figure B below) may not detect switching of the cover plate when laying the cover plate
(Figure A below) to left.
CAUSE:
In case the operation board (B) warps upward toward the direction (X) due to variation of parts and the gap
between the bottom face of the cover plate sensor switch inside KEY FAX (No.2) and the leading edge of the
sensor switch on the operation board is large,
the bottom face of the cover plate that is depressed when the cover plate is laid to left, does not enough push
the leading edge of the sensor switch on the operation board and switching the cover plate is not detected.
FIELD MEASURE:
In order to securely depress the sensor switch (D) on the operation board, a Lumirror sheet (No.3: 3X10mm
t=0.275mm) is applied to the sensor face on the cover plate sensor switch (C) to increase pushing distance.
PRODUCTION MEASURE:
A convex (t=0.3mm) is added to the sensor face on the cover plate sensor switch (C) inside KEY FAX (No.2) to
extend the detecting stroke.
1/3
A: Cover plate
A B: Operation board
C: Cover plate sensor switch
(part inside KEY FAX(No.2))
D: Sensor switch
X Going down
(warpage upward)
(warpage)
Cover plate
laid to left
Tab
One touch key and function keys when KEY FAX is correctly detected
(Cover plate laid to right) One touch key: #1 to #20
Function key: Memory TX, ON-hook, Pause/Redial, Abbreviation/Directory
(Cover plate laid to left) One touch key: #21 to #32, etc.
Function key: Register, TAD/Manual TX, Status, Print report, Duplex TX,
Polling, Delayed TX, Sub address, Broadcast, Confidential, Check
current status
*The operation board may not detect the cover plate (A) is laid to left and incorrectly detect it laid to right.
(e.g. Attempting to press Register key is detected as Memory TX)
2/3
Field measure Align to edge
0mm
<Cross-section view of cover plate detection>
0mm 0.5mm
Align to bump
A
1mm
3/3
Technical Bulletin UTAX CD 1118
UTAX CD 1218
UTAX CD 1222
TA DC 2118
TA DC 2218
TA DC 2222
TB 07 / Firmware Upgrade
SB-A034/M
Date: 21-04-2010
TOPIC:
Stopping the LSU drive while waiting JOB
CONTENT OF CHANGES:
1 Stopping the LSU drive The user may feel the LSU drive noisy if it is left for a long time because the LSU 430724 MAIN
while waiting JOB keeps rotating while waiting JOB. 429214
This is changed to stop the LSU drive in the following condition.
<Content of change>
1. In case JOB is not executed
--- The LSU drive is stopped when either the following continues for ten
seconds.
- The original is set at the DP - DP jam occurs
2. In case JOB is waiting
--- The LSU drive is stopped when either of the following continues for thirty
seconds.
- The error occurs while executing the Copy Job or the Print Job or the Fax Job.
Copy: <Copy mode error> is displayed at the operation panel in the
Command Center.
Print : <Print mode error> is displayed at the Copy screen.
Fax : <FAX mode error> is displayed at the Copy screen.
- The Scan screen is displayed. - Fax is sent.
- Network Fax is received or sent. - The service call error occurs.
2 Measure against the Normally, the power is turned off when the display of LCD disappears after the 429634 MAIN
LCD horizontal line main switch is turned off.
(Only for However, the horizontal thin line may remain in the LCD if the power is turned off
CD 1218, CD 1222 / before the LCD turning off.
DC 2218, DC 2222 ) This is corrected. (The LCD tuning off is most prioritized.)
1/2
FIRMWARE CD 1118 / DC 2118
Type Program No. Check SUM VER. Remarks
MAIN ---- ---- 2KK_2000.001.027 only DIMM (No.1) New
ENGINE ---- ---- 2KK_1000.004.001 only DIMM (No.1)
LANGUAGE ---- ---- 2KK_8100.001.007 only DIMM (No.1)
Separate firmware of MAIN, ENGINE and LANGUAGE is not supplied.
When upgrading firmware or replacing board etc., please upgrade each firmware (MAIN, ENGINE, LANGUAGE, PRINTER)
to the latest version at the same time.
* The above is the plan at the present moment. / Please note that this is subject to change.
2/2
Technical Bulletin UTAX CD 1118
UTAX CD 1218
UTAX CD 1222
TA DC 2118
TA DC 2218
TA DC 2222
TOPIC:
WIRE SCANNER BLACK/GRAY (No.1, 2) are changed as below to improve the procurement.
Accordingly, marking to the terminal is changed from black to red.
And, an attention is required when replacing the parts according to this change.
Please refer to Field Measure as below.
* New outer diameter after resin coating is same as the old one.
Before After
1/1
Technical Bulletin UTAX CD 1118
UTAX CD 1218
UTAX CD 1222
TA DC 2118
TA DC 2218
TA DC 2222
TOPIC:
The sub heater or the main heater in the fuser unit may be broken when the following service call error appears.
If only either of the heaters is broken, the machine becomes usable because the service call error is reset by
operation condition or environment.
C6000 J Fuser heater break
C6050 J Abnormally low fuser thermistor temperature
Please execute the following contents because it becomes cause of reoccurring the service call error (or the
fusing failure) if using continuously with the heater broken.
CHECK:
Please check the conductivity of each of the heaters by the tester for confirming the condition of the connection.
And, please surely replace the fuser unit or the heater if it is checked that the heater is broken.
Please check the conductivity of the heater each and the fastener terminal that is connected to the right side of
the thermostat as in the photo 2.
Check of the conductivity of the heater
Below is the state that the fuser unit is installed into the machine
Photo 2
Photo 1
Main heater
Sub heater
1/1
Technical Bulletin UTAX CD 1118
UTAX CD 1218
UTAX CD 1222
TA DC 2118
TA DC 2218
TA DC 2222
TOPIC:
Following are changed for procurement ease after the torque limiter (No.2) and the shaft (No.3) at the paper feed
section were changed to prevent the abnormal noise as informed per the Technical Bulletin TB-05.
Accordingly, attention is required when replacing the torque limiter (No.2) at the paper feed section (the paper feed
section of the main machine or PF-420). Please refer to [Field Measure] as below.
CONTENTS OF CHANGE:
External diameter of the torque limiter (No.2) at the paper feed section is changed from 18mm to 14mm. And, the
claw at the internal diameter of the housing of the new torque limiter (No.2) is changed to 4 positions, the color of
the housing is changed from black to white.
Size of the convex section (X in the figure below) at the side of the shaft (No.3) that matches the torque limiter
(No.2) at the paper feed section (the paper feed section of the main machine or PF-420) is reduced by 2mm
because the shape of the torque limiter (No.2) that receives convex section (X) at the shaft (No.3) is changed
according to the above change 1). According to the above change 1), the torque limiter (No.4: It is same as the
torque limiter at the paper feed section before the last change) at the drive section is also changed. (Its claw is 4
positions and the color of its housing is white.)
The torque limiter (No.2) and the shaft at the paper feed section
(Only the torque limiter (No.4) is individually changed at the drive section of the main machine.)
A
Before After
X
X
B
New No.3: length of X is 4.3mm
Old No.3: length of X is 6.3mm
* Convex sections (X) are in two places of both sides of the shaft.
(Matching condition: view from A of above figure) (Matching condition: view from B of above figure)
X
X
* Convex section (X) at the old shaft (No.3) matches to * Convex section (X) at the new shaft (No.3) matches to
the bump at the inside diameter of the old torque the U-shape notch section of the new torque limiter
limiter (No.2). (No.2).
1/3
Old Part New Part Q’ty Compatibility
No. Description SP Remarks
No. No.
Old New Old New
However, the new No.2, 3 can be individually fitted for the machine before the Technical
Bulletin TB-05.
(*) Please refer to the next page for change history of the torque limiter and the shaft at the
paper feed section, the parts that can be used
And both of new and old torque limiter (No.4) at the drive section can be used.
Serial Nos. of Affected Machine: CD 1118 / DC 2118 J from the production in September, 2010 on.
CD 1218 / DC 2218 J from the production in September, 2010 on.
CD 1222 / DC 2222 J from the production in September, 2010 on.
PF 420 / PF 420 J from the production in September, 2010 on.
2/3
Change history of the torque limiter and the shaft at the paper feed section
Color of the housing: Black Color of the housing: Black Color of the housing: White
Torque limiter
2KK06051 2C907280 2KK06051
(No.2)
Shaft
2KK06080 2C907300 2KK06080
(No.3)
(*) The above (the torque limiter and the shaft at the paper feed section) in the table are the parts that can be individually
used and replaced for each of the machine when replacing the parts.
Please use the above combination because the old and new shape for matching is different between 2KK… parts and
2C9… parts of the torque limiter and the shaft at the paper feed section.
3/3
Technical Bulletin UTAX CD 1118
UTAX CD 1218
UTAX CD 1222
TA DC 2118
TA DC 2218
TA DC 2222
TB 11 / Firmware Upgrade
SB-A281/M
Date: 08-09-2010
Only CD 1118 / DC 2118
TOPIC:
The firmware is upgraded as follows.
CONTENTS OF CHANGE:
Contents Details
Preventing JAM when JAM may occur with difference from the actual paper size because the changed value is not
the setting of folio size informed to the engine and the processing is performed with the initial value even if the value
is changed at U035 <Setting folio size Length/Width>.
is changed
Therefore, this is corrected.
(The actual processing is performed with the initial value while the changed value is displayed
MAIN + ENGINE
on the panel.)
Measure against The panel may lock up due to continuing to wait for the signal that is sent from the engine
panel lock-up board to the main board when the signal is not sent depending on timing of pushing the start
key in the following setting.
- The original is scanned at the table
- Copy is executed while opening the platen cover
- Original of the second pages and after of continuous scanning
(Not occurring at the first page of the original)
- The start key is immediately pushed after setting the original
1/2
Classification: Entire Stock Rework
In-Field modification at next visit
X In-Field modification by case
No modification necessary
Field Measure: Please upgrade the main firmware in case the above phenomenon arises.
2/2
Technical Bulletin UTAX CD 1118
UTAX CD 1218
UTAX CD 1222
TA DC 2118
TA DC 2218
TA DC 2222
TOPIC:
The parts number of the cover inner left (No.1) is registered.
1 .
Serial Nos.:
1/1
Technical Bulletin UTAX CD 1118
UTAX CD 1218
UTAX CD 1222
TA DC 2118
TA DC 2218
TA DC 2222
TOPIC:
Rear part of the DP frame guide may be warped by the torque from the DP hinges in high temperature environment and the
level is higher than the original guide plate at the main machine side. Then, leading edge of the original may be caught by
the guide that may cause jam (J7*) or blurred image. - Therefore, following are changed.
CONTENT OF CHANGES:
Following are changed to improve margin for paper conveying.
5 pcs. (5 locations) of FILM PULLEY(No3) are currently affixed at the leading edge of the guide.
(Field measure) FILM BASE SP(No1) are affixed on 5 locations of FILM PULLEY(No3).
(Affixed on the current films)
(Production) 2 locations at the rear side are changed to FILM BASE(No2).
*Refer to the next page for details.
Guide
Top of guide
Film (No.1)
Original guide plate
Original guide plate
Leading edge of original may be caught by the DP guide
Original guide plate
if the level is high. Film (No.1) are added.
1/4
BEFORE:
FILM PULLEY(No.3)
(X) front side 3 locations
PRODUCTION MEASURE:
2 locations of FILM at the rear side marked (Y) are changed.
No.3 11mm
7±0.5mm
21mm (t=0.125mm)
2/4
FIELD MEASURE:
FILM (No.1) is added to 5 locations of FILM PULLEY(No.3) that are currently affixed on the DP guide.
(FILM (No.1) may be affixed on 3 locations at the front side to improve the margin, however, in case the DP hinge is aligned
to the maximum, front 3 locations may run over the original guide plate. Do not affix FILM if it runs over)
Affixing condition
<FILM (No.1)>
FILM (No.1)
11.5mmm
No.3 3mm
(t=0.075mm)
21mm
No.1
(shaded area : double-side tape)
GUIDE READING
2 points
1
screws
3/4
Check machine by side view if DP A) Correcting DP
has no gap or is not warped.
DP Open DP and
In case gap or warp is found, adjust
A and B. push gently
Front
Adjuster screw
Field Measure: Please affix FILM (No.1) that is a set of 5 pcs. when the above phenomenon arises.
(Refer to page 3 to affix the FILM ).
4/4
Technical Bulletin UTAX CD 1118
UTAX CD 1218
UTAX CD 1222
TA DC 2118
TA DC 2218
TA DC 2222
TOPIC:
The parts number of the PWB RFID (No.1) is registered.
1 .
1/1
Technical Bulletin UTAX CD 1118
UTAX CD 1218
UTAX CD 1222
TA DC 2118
TA DC 2218
TA DC 2222
TB 15 / Firmware Upgrade
2KH-B210/M
Date: 18-07-2011
TOPIC:
The firmware is upgraded as follows.
CONTENTS OF CHANGE:
NEW:
U166 Extend Drive Time is newly implemented to set the aging time.
Simulation U166 - TIME(S)
Value setting: 0 Aging not extended
1 Aging extended by 3sec.
2 Aging extended by 4sec.
3 Aging extended by 5sec.
4 Aging extended by 6sec.
5 Aging extended by 7sec.
6 Aging extended by 8sec.
7 Aging extended by 9sec.
FIRMWARE UPGRADE
Type Program No. Check-S VER. Remarks
MAIN ---- ---- 2KK_2000.001.030 only CD 1118 / DC 2118 (DIMM No.1) New
ENGINE ---- ---- 2KK_1000.008.001 only CD 1118 / DC 2118 (DIMM No.1) New
LANGUAGE ---- ---- 2KK_8100.001.007 only CD 1118 / DC 2118 (DIMM No.1)
1/2
FIRMWARE UPGRADE
Type Program No. Check-S VER. Remarks
MAIN (IPU) 2KH_2000.001.045 ---- 001.045 only CD 1218, DC 1222 / DC 2218, DC 1222 New
ENGINE 2KK_1000.008.001 ---- 008.001 only CD 1218, DC 1222 / DC 2218, DC 1222 New
LANGUAGE E 2KH_81XE.001.003 ---- 001.003 only CD 1218, DC 1222 / DC 2218, DC 1222
Field Measure: Please upgrade the firmware when the above problem arises.
CD 1118 / DC 2118 upgrade only be DIMM (No.1)
Serial Nos.: 1118 / DC 2118
CD
CD 1218 / DC 2218 Planned from June 2011 production.
CD 1222 / DC 2222
2/2
Technical Bulletin UTAX CD 1118
UTAX CD 1218
UTAX CD 1222
TA DC 2118
TA DC 2218
TA DC 2222
TOPIC:
SPRING REGIST SW may contact the paper and it may come off when clearing the jam, etc. Therefore, the shape of
SPRING REGIST SW is changed.
Please note that jam* occurs if SPRING REGIST SW comes off and the registration actuator does not come back.
(*The registration switch is not turned off and the multiple-sheet jam (JAM20/21/22) may be detected.)
CONTENTS OF CHANGE:
The hooking part to the actuator of SPRING REGIST SW (No1) is extended to make it hard to come off.
1/2
Old Part New Part Q’ty Compatibility
No. Description SP Remarks
No. No.
Old New Old New
Field Measure: Please replace with the new part (No.1) when the above phenomenon arises.
Serial Nos.: 1118 / DC 2118
CD
CD 1218 / DC 2218 Planned from June 2011 production.
CD 1222 / DC 2222
2/2
Technical Bulletin UTAX CD 1118
UTAX CD 1218
UTAX CD 1222
TA DC 2118
TA DC 2218
TA DC 2222
TOPIC:
The following part names listed in the parts list are changed.
3 .
2 .
WRONG CORRECT
Fig. No. Part No. Description Fig. No. Part No. Description
1/2
Classification: Entire Stock Rework
In-Field modification at next visit
In-Field modification by case
X No modification necessary
2/2
Technical Bulletin UTAX CD 1118
UTAX CD 1218
UTAX CD 1222
TA DC 2118
TA DC 2218
TA DC 2222
TOPIC:
The Parts number is set up to the parts below (No. A) in the fuser section.
A .
1/1