You are on page 1of 12

1 2 3 4 5 6 7 8

EXISTING CLARIFIER

B FOR CONCRETE DETAIL


REFER DRG:
3322.11-67-C-XXX

OVERFLOW
C TANK 01
67-TNK-XXX

6364
OVERFLOW TANK
PUMP 01
D 67-TNK-XXX

1288
OVERFLOW TANK W.P.08
PUMP 02
67-TNK-XXX

OVERFLOW EXISTING CABLE


E TANK 02 RACK
67-TNK-XXX 6364 2307

5058

PLAN VIEW
SCALE 1:100

F PRELIMINARY - NOT FOR CONSTRUCTION


UNLESS OTHERWISE STATED ALL TECHNICAL: PLOT SCALE: AS SHOWN TITLE: ADR PLANT
L2, 38 RICHARDSON ST
WEST PERTH, 6005
PT BUMI SUKSESNDO DIMENSIONS IN MILLIMETRES
TOLERANCES:
LINEAR: 1
TECHNICAL: DRAWN: DN 11/03/2022 OVERFLOW TANKS
WESTERN AUSTRALIA ANGULAR: 1
PRO MGR: CKD: GENERAL ARRANGEMENT
A 11/03/2022 DN ISSUED FOR COMMENTS +61 8 9432 0100 TUJUH BUKIT HEAP LEACH DRAWING TO AS1100-201 1992 CLIENT: ENG MGR: GENERAL ARRANGEMENT PLAN
NEITHER THIS DOCUMENT NOR ITS CONTENTS MAY BE USED OR ©COPYRIGHT SIZE
GOLD PROJECT
No: DATE: BY: DESCRIPTION: DFT: ENG: ENG: PROJ: CLIENT: DRG. No. SHT: OF: REV:
www.comoeng.com.au
REVISIONS CHECK APPROVAL REPRODUCED IN ANY MANNER WITHOUT WRITTEN AUTHORIZATION. A3 3322.11-67-G-010 1 1 A
3322.11-GAA006
1 2 3 4 5 6 7 8

EXISTING PIPE RACK OVERFLOW TANK 02 OVERFLOW TANK 01


67-TNK-XXX 67-TNK-XXX

B 9000
4500

R.L. 51.0255 T.O.S.

R.L. 46.150 T.O.C.


D R.L. 46.000 G.L.

= =
716

OVERFLOW TANK OVERFLOW TANK FOR CONCRETE DETAIL


PUMP 02 PUMP 01 REFER DRG:
67-PMP-XXX 67-PMP-XXX 3322.11-67-C-XXX

E ELEVATION VIEW
SCALE 1:100

F PRELIMINARY - NOT FOR CONSTRUCTION


UNLESS OTHERWISE STATED ALL TECHNICAL: PLOT SCALE: AS SHOWN TITLE: ADR PLANT
L2, 38 RICHARDSON ST
WEST PERTH, 6005
PT BUMI SUKSESINDO DIMENSIONS IN MILLIMETRES
TOLERANCES:
LINEAR: 1
TECHNICAL: DRAWN: DN 15/03/2022 OVERFLOW TANKS
WESTERN AUSTRALIA ANGULAR: 1
PRO MGR: CKD: GENERAL ARRANGEMENT
A 15/03/2022 DN ISSUED FOR COMMENTS +61 8 9432 0100 TUJUH BUKIT HEAP LEACH DRAWING TO AS1100-201 1992 CLIENT: ENG MGR: GENERAL ARRANGEMENT ELEVATIONS
NEITHER THIS DOCUMENT NOR ITS CONTENTS MAY BE USED OR ©COPYRIGHT SIZE
GOLD PROJECT
No: DATE: BY: DESCRIPTION: DFT: ENG: ENG: PROJ: CLIENT: DRG. No. SHT: OF: REV:
www.comoeng.com.au
REVISIONS CHECK APPROVAL REPRODUCED IN ANY MANNER WITHOUT WRITTEN AUTHORIZATION. A3 3322.11-67-G-011 1 1 A
3322.11-GAA006
1 2 3 4 5 6 7 8

UNLOADING POINT LOADING POINT

F
TECHNICAL: PLOT SCALE: TITLE:
TECHNICAL: DRAWN:
PRO MGR: CKD:
CLIENT: ENG MGR:
No: DATE: BY: DESCRIPTION: DFT: ENG: ENG: PROJ: CLIENT:
©
REVISIONS CHECK APPROVAL
1 2 3 4 5 6 7 8

UNLOADING POINT LOADING POINT

F
TECHNICAL: PLOT SCALE: TITLE:
TECHNICAL: DRAWN:
PRO MGR: CKD:
CLIENT: ENG MGR:
No: DATE: BY: DESCRIPTION: DFT: ENG: ENG: PROJ: CLIENT:
©
REVISIONS CHECK APPROVAL
1 2 3 4 5 6 7 8

FILTER FEED TANK DETOX FILTER FILTER FEED PUMP DIATOMACEUS EARTH DIATOMACEUS EARTH DETOX FILTER
N 67-TNK-XXX SUMP PUMP 67-PMP-XXX DOSING PUMP MIXING TANK 67-FIP-XXX
67-PMP-XXX 67-PMP-XXX 67-TNK-XXX
24000
A

10175
4500
3375 3125 1300

530
A
G-003

1060
3800
4000

FILTRATE PUMP
B 5490 67-PMP-XXX

4100
FILTRATE HOPPER
8500

67-HP-XXX

1800
1835
4250

C
REMOVE OLD BUND
IN THIS AREA.

EXISTING RAMP TO
2100

BE REMOVED
869
1175

BUND EXTENDED TO
3844

NEW RAMP

4750
D
NEW RAMP TO
BE INSTALLED
CL EXISTING
FEED TANK
67-TNK-217

E
2450
9860 1630

EXISTING FEED TANK NEW STAIR LANDING EXISTING FILTER AREA UPPER LEVEL
67-TNK-217 DRG# 3322.11-67-C-XXX DRG# 3322.07-67-G-002 LOADING BAY

PLAN VIEW
SCALE 1:100
ROOF & GRATING REMOVED FOR CLARITY NOTE:

FOR APPROVAL - NOT FOR CONSTRUCTION


NEW MCC LOCATED OPPOSITE EXISTING FILTER
F FOR DETAILS REFER DRG: 3322.11-67-G-008
A 04/03/2022 DN ISSUED FOR COMMENTS # # # # UNLESS OTHERWISE STATED ALL TECHNICAL: # PLOT SCALE: AS SHOWN TITLE: ADR PLANT
B 09/03/2022 DN ISSUED FOR APPROVAL # # # # L2, 38 RICHARDSON ST
WEST PERTH, 6005
PT BUMI SUKSESINDO DIMENSIONS IN MILLIMETRES
TOLERANCES:
LINEAR: 1
TECHNICAL: # DRAWN: DN 04/03/2022 DETOX FILTER AREA UPGRADE
C 15/03/2022 DN RE-ISSUED FOR APPROVAL # # # #
WESTERN AUSTRALIA ANGULAR: 1
PRO MGR: # CKD: # GENERAL ARRANGEMENT
D RE-ISSUED FOR APPROVAL +61 8 9432 0100 TUJUH BUKIT HEAP LEACH DRAWING TO AS1100-201 1992 CLIENT: ENG MGR: # GENERAL ARRANGEMENT PLAN
NEITHER THIS DOCUMENT NOR ITS CONTENTS MAY BE USED OR ©COPYRIGHT SIZE
GOLD PROJECT
No: DATE: BY: DESCRIPTION: DFT: ENG: ENG: PROJ: CLIENT: DRG. No. SHT: OF: REV:
www.comoeng.com.au
REVISIONS CHECK APPROVAL REPRODUCED IN ANY MANNER WITHOUT WRITTEN AUTHORIZATION. A3 3322.11-67-G-002 1 1 D
3322.11-GAA002
1 2 3 4 5 6 7 8

FILTER CONTROL CABINET


67-MCC-XXX
CL FILTER
FEED TANK
DETOX FILTER 67-TNK-XXX
67-FIP-XXX 6000 6000 6575

R.L. 52.455 T.O.S.


R.L. 52.150 T.O.S.
TANK

R.L. 49.350 T.O.S.


C R.L. 49.010 T.OS.
TANK

FILTRATE PUMP
67-PMP-XXX
R.L. 47.150

R.L. 46.400
R.L. 46.150 T.O.C.
BUND WALL
R.L. 000.000 F.G.L.
D

FILTER CHUTES DIATOMACEUOUS DIATOMACEOUS EARTH DETOX FILTER FILTER FEED TANK
67-CHU-XX1 EARTH TANK DOSING PUMP SUMP PUMP 67-TNK-XXX
67-CHU-XX2 67-TNK-XXX 67-PMP-XXX 67-PMP-XXX

E SECTION A
G-002

F PRELIMINARY - NOT FOR CONSTRUCTION


UNLESS OTHERWISE STATED ALL TECHNICAL: # # PLOT SCALE: AS SHOWN TITLE: ADR PLANT
L2, 38 RICHARDSON ST
WEST PERTH, 6005
PT BUMI SUKSESINDO DIMENSIONS IN MILLIMETRES
TOLERANCES:
LINEAR: 1
TECHNICAL: # # DRAWN: DN 09/03/2022 DETOX FILTER AREA UPGRADE
A 09/03/2022 DN ISSUED FOR COMMENTS # # # #
WESTERN AUSTRALIA ANGULAR: 1
PRO MGR: # CKD: # # GENERAL ARRANGEMENT
B ISSUED FOR APPROVAL +61 8 9432 0100 TUJUH BUKIT HEAP LEACH DRAWING TO AS1100-201 1992 CLIENT: ENG MGR: # # GENERAL ARRANGEMENT ELEVATIONS
NEITHER THIS DOCUMENT NOR ITS CONTENTS MAY BE USED OR ©COPYRIGHT SIZE
GOLD PROJECT
No: DATE: BY: DESCRIPTION: DFT: ENG: ENG: PROJ: CLIENT: DRG. No. SHT: OF: REV:
www.comoeng.com.au
REVISIONS CHECK APPROVAL REPRODUCED IN ANY MANNER WITHOUT WRITTEN AUTHORIZATION. A3 3322.11-67-G-003 1 1 B
3322.11 FA2 FILTER AREA
1 2 3 4 5 6 7 8

A
EXISTING DETOX
CLARIFIER SEE DRG:
3322.07-67-G-004
6046 24200
FLOCCULENT PLANT
SHELTER STRUCTURE 1435 6000
REFER TO DRG:
3322.11-67-S-XXX 75 5950 92

EXISTING PIPE
SUPPORT.

B CP08

4714
16059
14230

12725
C
7880

25450
CL THICKENER
1088

1250
D
FEED PIPE

12725
RAISED WALKWAY
& STAIRS SEE DRG:
3322.11-67-S-XXX

FOR CONCRETE
DETAILS REFER DRG:
3322.11-67-C-XXX
E
B
OVERFLOW 3706 12100
G-005
13640
CL CLARIFIER

DETOX CLARIFIER
AREA SUMP PUMP
67-PMP-XXX
PLAN VIEW
SCALE 1:200

F FOR APPROVAL - NOT FOR CONSTRUCTION


UNLESS OTHERWISE STATED ALL TECHNICAL: # # PLOT SCALE: AS SHOWN TITLE: ADR PLANT
L2, 38 RICHARDSON ST
WEST PERTH, 6005
PT BUMI SUKSESINDO DIMENSIONS IN MILLIMETRES
TOLERANCES:
LINEAR: 1
TECHNICAL: # # DRAWN: DN 11/03/2022 DETOX CLARIFIER AREA UPGRADE
A 11/03/2022 DN ISSUED FOR COMMENTS # # # #
WESTERN AUSTRALIA ANGULAR: 1
PRO MGR: # CKD: # # GENERAL ARRANGEMENT
B 11/03/2022 DN ISSUED FOR APPROVAL +61 8 9432 0100 TUJUH BUKIT HEAP LEACH DRAWING TO AS1100-201 1992 CLIENT: ENG MGR: # # GENERAL ARRANGEMENT PLAN
NEITHER THIS DOCUMENT NOR ITS CONTENTS MAY BE USED OR ©COPYRIGHT SIZE
GOLD PROJECT
No: DATE: BY: DESCRIPTION: DFT: ENG: ENG: PROJ: CLIENT: DRG. No. SHT: OF: REV:
www.comoeng.com.au
REVISIONS CHECK APPROVAL REPRODUCED IN ANY MANNER WITHOUT WRITTEN AUTHORIZATION. A3 3322.11-67-G-004 1 1 B
3322.11-GAA003
1 2 3 4 5 6 7 8

EXISTING PIPE
SUPPORT 14230 11775 950

B
R.L. 53.850 T.O.S.

R.L. 52.700

R.L. 52.070

EXISTING DETOX R.L. 51.275 T.O.S.


CLARIFIER

R.L. 48.700

R.L. 46.400 T.O.C.

R.L. 46.300 G.L.

CLARIFIER TANK CLARIFIER AREA


FLOCCULANT PLANT 67-THK-XXX SUMP PUMP
67-PMP-XXX
12725

25450

SECTION B
SCALE: 1:100 G-004
E

F FOR APPROVAL - NOT FOR CONSTRUCTION


UNLESS OTHERWISE STATED ALL TECHNICAL: # # PLOT SCALE: AS SHOWN TITLE: ADR PLANT
A 11/03/2022 DN ISSUED FOR COMMENTS # # # # L2, 38 RICHARDSON ST
WEST PERTH, 6005
PT BUMI SUKSESINDO DIMENSIONS IN MILLIMETRES
TOLERANCES:
LINEAR: 1
TECHNICAL: # # DRAWN: DN 11/03/2022 DETOX AND CLARIFIER UPGRADE
B 15/03/2022 DN ISSUED FOR APPROVAL # # # #
WESTERN AUSTRALIA ANGULAR: 1
PRO MGR: # CKD: # # GENERAL ARRANGEMENT
C RE-ISSUED FOR APPROVAL +61 8 9432 0100 TUJUH BUKIT HEAP LEACH DRAWING TO AS1100-201 1992 CLIENT: ENG MGR: # # GENERAL ARRANGEMENT PLAN
NEITHER THIS DOCUMENT NOR ITS CONTENTS MAY BE USED OR ©COPYRIGHT SIZE
GOLD PROJECT
No: DATE: BY: DESCRIPTION: DFT: ENG: ENG: PROJ: CLIENT: DRG. No. SHT: OF: REV:
www.comoeng.com.au
REVISIONS CHECK APPROVAL REPRODUCED IN ANY MANNER WITHOUT WRITTEN AUTHORIZATION. A3 3322.11-67-G-005 1 1 C
3322.11-GAA003
1 2 3 4 5 6 7 8

A
EXISTING SCAVENGER CARBON SAFETY CARBON SAFETY SCAVENGER SCAVENGER SCAVENGER SCAVENGER SCAVENGER BASKET
CIRCUIT SCREEN 2 SCREEN 1 VESSEL 20 VESSEL 19 VESSEL 18 VESSEL 17 STRAINER 2
65-SCR-XXX 65-SCR-XXX 65-TNK-XXX 65-TNK-XXX 65-TNK-XXX 65-TNK-XXX 65-FIL-XXX

SCAVENGER BASKET
STRAINER 1
65-FIL-XXX

7169
766

675
C
8000
9375

292

D 8298 2655 2689 1194


11210 4500 4500 4500 702
29710
32802

PLAN VIEW
SCALE 1:150

F FOR APPROVAL - NOT FOR CONSTRUCTION


UNLESS OTHERWISE STATED ALL TECHNICAL: # # PLOT SCALE: AS SHOWN TITLE: ADR PLANT
A 11/03/2022 DN ISSUED FOR COMMENTS # # # # L2, 38 RICHARDSON ST
WEST PERTH, 6005
PT BUMI SUKSESINDO DIMENSIONS IN MILLIMETRES
TOLERANCES:
LINEAR: 1
TECHNICAL: # # DRAWN: DN 11/03/2022 SCAVENGER AREA
B 18/03/2022 DN ISSUED FOR APPROVAL # # # #
WESTERN AUSTRALIA ANGULAR: 1
PRO MGR: # CKD: # # GENERAL ARRANGEMENT
C RE-ISSUED FOR APPROVAL +61 8 9432 0100 TUJUH BUKIT HEAP LEACH DRAWING TO AS1100-201 1992 CLIENT: ENG MGR: # # GENERAL ARRANGEMENT PLAN
NEITHER THIS DOCUMENT NOR ITS CONTENTS MAY BE USED OR ©COPYRIGHT SIZE
GOLD PROJECT
No: DATE: BY: DESCRIPTION: DFT: ENG: ENG: PROJ: CLIENT: DRG. No. SHT: OF: REV:
www.comoeng.com.au
REVISIONS CHECK APPROVAL REPRODUCED IN ANY MANNER WITHOUT WRITTEN AUTHORIZATION. A3 3322.11-67-G-006 1 1 C
3322.11-GAA004
1 2 3 4 5 6 7 8

CARBON SAFETY CARBOIN SAFETY SCAVENGER SCAVENGER SCAVENGER SCAVENGER STRUCTURAL DETAIL
SCREEN 2 SCREEN 1 VESSEL 20 VESSEL 19 VESSEL 18 VESSEL 17 REFER DRG:
65-SCR-XXX 65-SCR-XXX 65-TNK-XXX 65-TNK-XXX 65-TNK-XXX 65-TNK-XXX 3322.11-65-S-XXX

R.L. 53.875 T.O.S.

C R.L. 50.525 T.O.S. R.L. 50.645 T.O.S.

R.L. 49.020 T.O.S.

R.L. 47.000 T.O.C.


R.L. 46.800
D

2655 2689
11210 4500 4500 4500
32801.5

E ELEVATION VIEW
SCALE 1:100

F FOR APPROVAL - NOT FOR CONSTRUCTION


UNLESS OTHERWISE STATED ALL TECHNICAL: # # PLOT SCALE: AS SHOWN TITLE: ADR PLANT
A 11/03/2022 DN ISSUED FOR COMMENTS # # # # L2, 38 RICHARDSON ST
WEST PERTH, 6005
PT BUMI SUKSESINDO DIMENSIONS IN MILLIMETRES
TOLERANCES:
LINEAR: 1
TECHNICAL: # # DRAWN: DN 11/03/2022 SCAVENGER AREA
B 15/03/2022 DN ISSUED FOR APPROVAL # # # #
WESTERN AUSTRALIA ANGULAR: 1
PRO MGR: # CKD: # # GENERAL ARRANGEMENT
C RE-ISSUED FOR APPROVAL +61 8 9432 0100 TUJUH BUKIT HEAP LEACH DRAWING TO AS1100-201 1992 CLIENT: ENG MGR: # # GENERAL ARRANGEMENT PLAN AND ELEVATIONS
NEITHER THIS DOCUMENT NOR ITS CONTENTS MAY BE USED OR ©COPYRIGHT SIZE
GOLD PROJECT
No: DATE: BY: DESCRIPTION: DFT: ENG: ENG: PROJ: CLIENT: DRG. No. SHT: OF: REV:
www.comoeng.com.au
REVISIONS CHECK APPROVAL REPRODUCED IN ANY MANNER WITHOUT WRITTEN AUTHORIZATION. A3 3322.11-67-G-007 1 1 C
3322.11-GAA004
1 2 3 4 5 6 7 8

N 2220 17000
2750 11500
5750
A 4771

4500
4700
B

12800
4150
24700

C
2170

848.3

698.3
NEW PEROXIDE
AREA
16050

3631
1213

D 0
6100

NEW DETOX
FILTER AREA MCC

= = A
6050
E 2924 G-009

10720
EXISTING DETOX
FILTER AREA

EXISTING DETOX PLAN VIEW


FILTER AREA MCC SCALE 1:150

F PRELIMINARY - NOT FOR CONSTRUCTION


UNLESS OTHERWISE STATED ALL TECHNICAL: # # PLOT SCALE: AS SHOWN TITLE: ADR PLANT
L2, 38 RICHARDSON ST
WEST PERTH, 6005
PT BUMI SKSESINDO DIMENSIONS IN MILLIMETRES
TOLERANCES:
LINEAR: 1
TECHNICAL: # # DRAWN: DN 15/03/2022 DETOX FILTER AREA UPGRADE
A 15/03/2022 DN ISSUED FOR COMMENTS # # # #
WESTERN AUSTRALIA ANGULAR: 1
PRO MGR: # CKD: # # MCC & PEROXIDE AREA
B ISSUED FOR APPROVAL +61 8 9432 0100 TUJUH BUKIT HEAP LEACH DRAWING TO AS1100-201 1992 CLIENT: ENG MGR: # # GENERAL ARRANGEMENT PLAN
NEITHER THIS DOCUMENT NOR ITS CONTENTS MAY BE USED OR ©COPYRIGHT SIZE
GOLD PROJECT
No: DATE: BY: DESCRIPTION: DFT: ENG: ENG: PROJ: CLIENT: DRG. No. SHT: OF: REV:
www.comoeng.com.au
REVISIONS CHECK APPROVAL REPRODUCED IN ANY MANNER WITHOUT WRITTEN AUTHORIZATION. A3 3322.11-67-G-008 1 1 B
3322.11-GAA005
1 2 3 4 5 6 7 8

2438 8300
B 1219 2500 2900

R.L. 50.245 T.O.S.

R.L. 48.790 T.O.S.


C

R.L. 47.330 T.O.S.

R.L. 46.150 T.O.C.


R.L. 46.000 G.L.

D 7488 2500

EXISTING MCC NEW MCC NEW PEROXIDE


AREA

SECTION A
G-008

F FOR APPROVAL - NOT FOR CONSTRUCTION


UNLESS OTHERWISE STATED ALL TECHNICAL: # # PLOT SCALE: AS SHOWN TITLE: ADR PLANT
A 15/03/2022 DN ISSUED FOR COMMENTS # # # # L2, 38 RICHARDSON ST
WEST PERTH, 6005
PT BUMIT SUKSESINDO DIMENSIONS IN MILLIMETRES
TOLERANCES:
LINEAR: 1
TECHNICAL: # # DRAWN: DN 15/03/2022 DETOX FILTER AREA UPGRADE
B 18/03/2022 DN ISSUED FOR APPROVAL # # # #
WESTERN AUSTRALIA ANGULAR: 1
PRO MGR: # CKD: # # MCC & PEROXIDE AREA
C RE-ISSUED FOR APPROVAL +61 8 9432 0100 TUJUH BUKIT HEAP LEACH DRAWING TO AS1100-201 1992 CLIENT: ENG MGR: # # GENERAL ARRANGEMENT ELEVATIONS
NEITHER THIS DOCUMENT NOR ITS CONTENTS MAY BE USED OR ©COPYRIGHT SIZE
GOLD PROJECT
No: DATE: BY: DESCRIPTION: DFT: ENG: ENG: PROJ: CLIENT: DRG. No. SHT: OF: REV:
www.comoeng.com.au
REVISIONS CHECK APPROVAL REPRODUCED IN ANY MANNER WITHOUT WRITTEN AUTHORIZATION. A3 3322.11-67-G-009 1 1 C
3322.11-GAA005

You might also like