Yasamin Babaee Hemmatia Objective: To assess the color stability and translucency of full cubic stabilized
Hamid Neshandar Aslib zirconia (FSZ) following orthodontic bonding with different surface treatments
Alireza Mahmoudi and coffee thermocycling (CTC). Methods: This in vitro study was conducted
Nahavandic on 120 disc-shaped specimens of FSZ. Thirty specimens were selected as the
Nika Safarid control group and remained intact. The remaining specimens were randomly
Mehran Falahchaib divided into three groups based on the type of surface treatment (n = 30):
airborne particle abrasion (APA), silica-coating (CoJet), and carbon dioxide
(CO2) laser. After metal bracket bonding in the test groups, debonding and
polishing were performed. Subsequently, all specimens underwent CTC (10,000
cycles). Color parameters, color difference (ΔE00), and translucency parameter
a
Dental Sciences Research Center, (TP) were measured three times at baseline (t0), after debonding and polishing
Department of Orthodontics, School of (t1), and after CTC (t2). Data were statistically analyzed (α = 0.05). Results:
Dentistry, Guilan University of Medical
Sciences, Rasht, Iran
Significant difference existed among the groups regarding ΔE00t0t2 (p < 0.001).
b
Dental Sciences Research Center,
The APA group showed minimum (ΔE00 = 1.15 ± 0.53) and the control group
Department of Prosthodontics, School showed maximum (ΔE 00 = 0.19 ± 0.02) color stability, with no significant
of Dentistry, Guilan University of difference between the laser and CoJet groups (p = 0.511). The four groups
Medical Sciences, Rasht, Iran were significantly different regarding ∆TPt0t2 (p < 0.001). Maximal increases in
c
Color Imaging and Color Image TP were noted in the CoJet (1.00 ± 0.18) and APA (1.04 ± 0.38) groups while
Processing Department, Institute for
minimal increase was recorded in the control group (0.1 ± 0.02). Conclusions:
Color Science and Technology, Tehran,
Iran Orthodontic treatment makes zirconia restorations susceptible to discoloration
d
Dental Sciences Research Center, and increased translucency. Nonetheless, the recorded ∆E00 and ∆TP did not
School of Dentistry, Guilan University exceed the acceptability threshold.
of Medical Sciences, Rasht, Iran
Key words: Y-TZP ceramic, Brackets, Color, Surface treatment
Received June 28, 2022; Revised November 18, 2022; Accepted November 27, 2022.
How to cite this article: Babaee Hemmati Y, Neshandar Asli H, Mahmoudi Nahavandi
A, Safari N, Falahchai M. Effect of orthodontic bonding with different surface
treatments on color stability and translucency of full cubic stabilized zirconia after
coffee thermocycling. Korean J Orthod. Published online February 10, 2023. https://doi.
org/10.4041/kjod22.144
1
Babaee Hemmati et al • Orthodontic treatment and zirconia restorations
2 https://doi.org/10.4041/kjod22.144 www.e-kjo.org
Babaee Hemmati et al • Orthodontic treatment and zirconia restorations
A B A B
C D C
Figure 1. Scanning electron microscopic micrographs of Figure 2. Scanning electron microscopic micrographs of
the zirconia surface after different surface treatments. the zirconia surface after polishing (A) airborne particle
A, Control. B, Airborne particle abrasion. C, CoJet. D, CO2 abrasion; (B) CoJet; (C) CO2 laser (×80 magnification).
laser (×500 magnification).
www.e-kjo.org https://doi.org/10.4041/kjod22.144 3
Babaee Hemmati et al • Orthodontic treatment and zirconia restorations
ment: before surface treatment (baseline or t0), after cording to Paravina et al.34
debonding and polishing (t1), and after CTC (t2), and The translucency parameter (TP) was calculated ac-
twice for the control group: before surface treatment cording to the following formula based on the differ-
(baseline or t0) and after CTC (t2) (Figure 3). Prior to ence in L*, a*, and b* parameters measured against the
the measurements, the specimens were cleaned in an ul- standard white and black backgrounds:
trasonic bath and dried. A scalpel was used to create an
indentation in the specimen margin at one side to mark TP = [(Lb* − Lw*)2 + (ab* − aw*)2
the measurement surface and enable reproducible place- + (bb* − bw*)2]1/2
ment of specimens in the spectrophotometer. For colo-
rimetry, standard black and white backgrounds (Sealed Also, PT of translucency was considered to be 0.62
Paper Charts; Leneta, Bergen, NJ, USA) were used. The and AT of translucency was considered to be 2.62.35 The
specimens were placed at the center, and measurements TP was calculated at t0, t1, and t2 for the test groups,
were repeated three times for each specimen. The L*, and t0 and t2 for the control group. The TP of the con-
a*, b*, C*, and h° parameters were recorded. L* indi- trol group was used as the baseline TP for all groups.
cates lightness, a* indicates redness (positive)-greenness The Shapiro–Wilk test was applied to analyze the
(negative), b* indicates yellowness (positive)-blueness normality of data distribution. The homogeneity of
(negative), C* indicates chroma, and h° indicates the hue variances was evaluated by the Levene’s test. Repeated
angle. To calculate the color difference (∆E), the values measures analysis of variance (ANOVA) was applied to
measured against the white background were used with compare color parameters, TP, and ∆E00 within each test
the CIEDE2000 (∆E00) formula:33 group at different time points, followed by pairwise
comparisons by the Bonferroni test. Paired t -test was
ΔE00 = [(ΔLʹ/KLSL)2 + (ΔCʹ/KCSC)2 + (ΔHʹ/KHSH)2 used to compare color parameters and TP in the control
+ RT(ΔCʹ/KCSC)(ΔHʹ/KHSH)]1/2 group between t0 and t2. Other comparisons were made
by ANOVA. Pairwise comparisons were performed by the
In this study, CIEDE2000 50% perceptibility threshold Tukey’s test in case of homogeneity of variances, and
(PT) equal to 0.8 units and 50% acceptability threshold Games–Howell test in case of non-homogeneity of vari-
(AT) equal to 1.8 units were considered acceptable ac- ances. Accordingly, ANOVA followed by Tukey’s test (for
Colorimetry (t0)
Bonding procedure
Colorimetry (t1)
Colorimetry (t2)
4 https://doi.org/10.4041/kjod22.144 www.e-kjo.org
Babaee Hemmati et al • Orthodontic treatment and zirconia restorations
pairwise comparisons) were applied to compare TP and highest in APA group, and then CoJet, laser and control
∆E00 among different groups at each time point; where- in decreasing order with significant differences between
as, ANOVA followed by Games–Howell test (for pairwise the groups (p < 0.05).
comparisons) were applied to compare ∆E00t0t2, TP at Repeated measures ANOVA indicated that the changes
t2, and ∆TP (changes in TP) based on different surface in L*, a*, and h° at different time points were significant
treatments. All statistical analyses were carried out us- within each test group (p < 0.001). All pairwise com-
ing SPSS version 26 (IBM Co., Armonk, NY, USA) at 0.05 parisons of different time points revealed significant dif-
level of significance. ferences (p < 0.001). Regarding the ascending trend of
change in b* parameter from t0 to t2, significant differ-
RESULTS ences between different time points were only noted in
the CoJet group (p < 0.001). This trend was not signifi-
The mean and standard deviation of surface rough- cant from t0 to t1 (p = 0.197), but the changes from t1
ness were 0.13 ± 0.02 µm in the control group, 0.37 ± to t2, and t0 to t2 were significant (p < 0.001). Regard-
0.05 µm in the APA group, 0.33 ± 0.05 µm in the CoJet ing the descending trend of change in C*, this change
group, and 0.18 ± 0.03 µm in the laser group (Figure 1). was only significant in the CoJet group such that all
ANOVA revealed a significant difference in this regard pairwise comparisons yielded significant differences (p <
among the groups (p < 0.001, F = 329.80). Pairwise 0.001). In the control group, all color parameters expe-
comparisons showed that the surface roughness was rienced a significant change between t0 to t2 according
Table 1. Mean and standard deviation in L*, a*, b*, C*, and h° parameters in the four groups at the three time points (n =
40)
Time point
Variable Group p -value (F)
t0 t1 t2
L* APA 61.58 ± 0.61a 61.12 ± 0.64b 60.38 ± 0.62c < 0.001 (94.37)*
a b c
Laser 61.16 ± 0.45 61.01 ± 0.37 60.81 ± 0.37 < 0.001 (24.02)*
CoJet 60.51 ± 0.49a 60.37 ± 0.49b 60.10 ± 0.54c < 0.001 (13.01)*
a b
Control 61.11 ± 0.63 – 60.95 ± 0.63 < 0.001 (29.36)†
a* APA –1.38 ± 0.12a –1.43 ± 0.13b –1.51 ± 0.06c < 0.001 (21.38)*
a b
Laser –1.44 ± 0.10 –1.48 ± 0.10 –1.53 ± 0.05c < 0.001 (16.86)*
a b c
CoJet –1.38 ± 0.12 –1.43 ± 0.12 –1.52 ± 0.08 < 0.001 (103.64)*
a b
Control –1.40 ± 0.09 – –1.50 ± 0.10 < 0.001 (16.22)†
b* APA –7.04 ± 0.16 –6.99 ± 0.18 –6.91 ± 0.22 0.051 (4.02)*
Laser –7.01 ± 0.25 –6.97 ± 0.25 –6.93 ± 0.14 0.179 (1.87)*
a a b
CoJet –6.97 ± 0.16 –6.97 ± 0.16 –6.94 ± 0.16 < 0.001 (117.67)*
Control –7.00 ± 0.21a – –6.93 ± 0.20b < 0.001 (28.19)†
C* APA 7.17 ± 0.18 7.14 ± 0.19 7.07 ± 0.23 0.132 (2.36)*
Laser 7.15 ± 0.26 7.13 ± 0.26 7.10 ± 0.14 0.352 (0.89)*
CoJet 7.11 ± 0.17a 7.08 ± 0.17b 7.02 ± 0.18c < 0.001 (219.84)*
Control 7.14 ± 0.21a – 7.06 ± 0.21b < 0.001 (37.33)†
h° APA 258.91 ± 1.16a 258.31 ± 1.26b 257.54 ± 0.42c < 0.001 (25.23)*
a b
Laser 258.42 ± 0.54 258.03 ± 0.55 257.55 ± 0.42c < 0.001 (47.12)*
a b c
CoJet 257.81 ± 0.45 255.86 ± 0.83 257.81 ± 0.45 < 0.001 (258.45)*
a b
Control 258.65 ± 0.75 – 257.82 ± 0.76 < 0.001 (52.02)†
Means with similar superscripted lowercase letters within the same row are not significantly different (p > 0.05).
L* indicates lightness, a* indicates redness (positive)-greenness (negative), b* indicates yellowness (positive)-blueness
(negative), C* indicates chroma, and h° indicates the hue angle.
APA, airborne particle abrasion; t0, baseline; t1, after debonding and polishing; t2, after coffee thermocycling.
*Repeated measures ANOVA followed by pairwise comparisons with Bonferroni test.
†
Paired samples statistics.
www.e-kjo.org https://doi.org/10.4041/kjod22.144 5
Babaee Hemmati et al • Orthodontic treatment and zirconia restorations
Table 2. Comparison of the mean and standard deviation of ∆E00 in different surface treatments at different time points (n
= 40)
Effect of time on
Group ∆E00t0t1 ∆E00t1t2 ∆E00t0t2 each group (F)
APA 0.44 ± 0.20Aa 0.87 ± 0.41Ab 1.15 ± 0.53Ac < 0.001 (50.13)*
Ba Bb Bc
Laser 0.19 ± 0.12 0.38 ± 0.16 0.53 ± 0.24 < 0.001 (105.79)*
CoJet 0.50 ± 0.04Aa 0.64 ± 0.29Cb 0.62 ± 0.33Bab 0.007 (6.35)*
C
Control NA NA 0.19 ± 0.02
‡ ‡
Effect of group at each time point (F) < 0.001 (59.47) < 0.001 (26.52) < 0.001 (56.37) †
Means with the same superscripted uppercase letters within the same column are not significantly different (p > 0.05). Means
with the same superscripted lowercase letters within the same row are not significantly different (p > 0.05).
∆E00, color difference; APA, airborne particle abrasion; t0, baseline; t1, after debonding and polishing; t2, after coffee thermocycling;
NA, not available.
*Repeated measures ANOVA followed by pairwise comparisons with Bonferroni test.
†
ANOVA followed by pairwise comparisons with the Games–Howell test.
‡
ANOVA followed by pairwise comparisons with the Tukey’s test.
Table 3. Comparison of the mean and standard deviation of translucency parameter (TP) in different surface treatments
at different time points (n = 40)
Effect of time on
Group TPt0 TPt1 TPt2 each group (F)
APA 12.25 ± 0.16a 13.07 ± 0.33Ab 13.29 ± 0.38Ac < 0.001 (249.33)*
a Bb Bc
Laser 12.25 ± 0.16 12.71 ± 0.20 12.98 ± 0.24 < 0.001 (249.59)*
a Ab ABc
CoJet 12.25 ± 0.16 13.02 ± 0.17 13.23 ± 0.17 < 0.001 (1,020.19)*
Control 12.25 ± 0.16 NA 12.25 ± 0.16C
Effect of group at each time point (F) NA < 0.001 (25.46) ‡ < 0.001 (248.22) †
Means with the same superscripted uppercase letters within the same column are not significantly different (p > 0.05). Means
with the same superscripted lowercase letters within the same row are not significantly different (p > 0.05).
APA, airborne particle abrasion; t0, baseline; t1, after debonding and polishing; t2, after coffee thermocycling; NA, not
available.
*Repeated measures ANOVA followed by pairwise comparisons with Bonferroni test.
†
ANOVA followed by pairwise comparisons with the Games–Howell test.
‡
ANOVA followed by pairwise comparisons with the Tukey’s test.
to paired t -test (p < 0.001). At t2, the L*, a*, C* and h° ANOVA revealed a significant difference among the four
parameters significantly decreased while the b* param- groups (p < 0.001). Pairwise comparisons of the groups
eter significantly increased (Table 1). revealed significant differences between all groups (p <
Table 2 shows the comparison of the ∆E00 between 0.001) except for the difference between the laser and
t0t1, t1t2, and t0t2 for different surface treatments. Re- CoJet groups (p = 0.511).
sults showed a significant difference in ∆E00 between the Comparison of ∆E00 within each group showed that
test groups at the three time points (p < 0.001). Pairwise in the APA and laser groups, the mean value during
comparisons of the groups showed that the ∆E00t0t1 in t0t1 was significantly lower than that during t1t2 (p <
the laser group was significantly lower than that in the 0.001) and t0t2 (p < 0.001). Also, the mean value during
APA (p < 0.001) and CoJet (p < 0.001) groups, and the t1t2 was significantly lower than that during t0t2 (p <
difference between CoJet and APA was not significant (p 0.001). Nonetheless, in the CoJet group, only ∆E00t0t1
= 0.095). Regarding ∆E00t1t2, the APA group showed a was significantly lower than ∆E00t1t2 (p = 0.011). Other
significantly higher mean value than the laser (p < 0.001) comparisons revealed no significant difference (p > 0.05).
and CoJet (p = 0.003) groups. Also, the mean value in Regarding the TP, a significant differences were found
the CoJet group was significantly higher than that in among the three surface treatments at three assessment
the laser group (p < 0.001). Comparison of ∆E00t0t2 time points (Table 3). At t1, TP in the laser group was
between the control (0.19 ± 0.02) and other groups by significantly lower than that in the APA (p < 0.001) and
6 https://doi.org/10.4041/kjod22.144 www.e-kjo.org
Babaee Hemmati et al • Orthodontic treatment and zirconia restorations
Table 4. Comparison of the mean and standard deviation (SD) of changes in translucency parameter (∆TP) in different
surface treatments (n = 40)
Variable Groups Mean ± SD Minimum Maximum p -value (F)*
∆TP(t0t1) APA 0.82 ± 0.34A 0.22 1.63 < 0.001 (25.78)
Laser 0.46 ± 0.18B –0.55 0.63
CoJet 0.77 ± 0.16A –0.20 0.94
∆TP(t1t2) APA 0.22 ± 0.16 –0.72 0.35 0.058 (2.91)
Laser 0.27 ± 0.14 0.02 0.97
CoJet 0.20 ± 0.06 0.06 0.42
∆TP(t0t2) APA 1.04 ± 0.38A –0.03 1.91 < 0.001 (124.15)
Laser 0.73 ± 0.25B –0.42 1.54
CoJet 1.00 ± 0.18A –0.02 1.26
Control 0.10 ± 0.02C 0.06 0.13
Means with the same superscripted uppercase letters within the same column are not significantly different (p > 0.05).
APA, airborne particle abrasion; t0, baseline; t1, after debonding and polishing; t2, after coffee thermocycling.
*ANOVA followed by pairwise comparisons with the Games–Howell test.
CoJet (p < 0.001) groups. However, the difference be- adhesive remaining on the surface of specimens after
tween the APA and CoJet groups was not significant in debonding was variable, it was not possible to standard-
this regard (p > 0.05). Comparison of TP at t2 between ize the specimens regarding the polishing time. There-
the control and other groups by ANOVA showed no sig- fore, according to previous studies,32,37 achieving a visu-
nificant difference between the CoJet group and APA ally smooth surface was considered as the criterion for
(p = 0.082) and laser (p = 0.717) groups. Nonetheless, completion and termination of polishing. Moreover, to
the pairwise comparisons revealed significant differences ensure optimal quality of polishing, two additional spec-
(p < 0.001). Comparison of time points showed that in imens from each group underwent SEM assessment after
all groups, TP significantly increased from t0 to t2 (p polishing. Nonetheless, future studies are recommended
< 0.001). Table 4 compares the changes in TP (∆TP) to assess the surface roughness of specimens after pol-
at different time points. Significant differences were ishing to ensure no significant difference among the
noted among different groups in ∆TPt0t1 and ∆TPt0t2 specimens in this regard.
(p < 0.001); while, this difference was not significant To better simulate the clinical setting in the pres-
for ∆TPt1t2 (p = 0.058). Pairwise comparisons showed ent study, a plier was used for debonding instead of
no significant difference between the APA and CoJet a universal testing machine, similar to previous stud-
groups regarding ∆TPt0t1 and ∆TPt0t2 (p = 0.762 and ies.27,32,37 However, one previous study26 used a universal
p = 0.818, respectively); however, these values were sig- testing machine to standardize the debonding process
nificantly lower in the laser group (p < 0.001). of specimens. It appears that using a universal testing
machine decreases the generalizability of the results. For
DISCUSSION instance, the residual adhesive on the specimen surface
may be much lower or higher than what it seems. Thus,
The present results showed significant effect of orth- although using a plier may cause higher variability after
odontic bonding with different surface treatments and debonding in specimens, we tried to compensate for it
CTC on color parameters, color stability, and TP of FSZ. by increasing the sample size.
Thus, the null hypothesis of the study was rejected. In The current results revealed that in comparison of
general, there is no similar study on zirconia to compare different surface treatments applied, the APA group
our results with. Nonetheless, some relevant studies have showed minimum and the laser and CoJet groups
been conducted on enamel and feldspathic porcelain, showed maximum color stability after orthodontic bond-
reporting controversial results. Some studies reported ing and CTC. Minimum color change was noted when
that the color change caused by orthodontic treatment comparing before and after orthodontic treatment,
exceeded the clinically acceptable threshold, and even and CTC had a higher contribution in discoloration of
polishing could not correct it.19,21,26 However, other stud- bonded specimens. The discoloration caused in control
ies reported that the color change was insignificant and specimens following CTC was insignificant, and bonded
reversible.17,18,23,27,36 groups showed much lower color stability than intact
In the present study, since the amount of residual specimens after CTC. Nonetheless, the calculated ∆E00
www.e-kjo.org https://doi.org/10.4041/kjod22.144 7
Babaee Hemmati et al • Orthodontic treatment and zirconia restorations
did not exceed AT or even PT in any group at any time surface roughness of the underlying substrate may not
point. Perceptibility refers to judgment regarding pres- reach the baseline value.26,41 Thus, specimens that un-
ence/absence of precise color match between the tooth derwent surface treatments exhibited increase in surface
and restoration, and lower perceptibility values indicate roughness leading to greater increase in translucency
a color match close to perfect.9 Acceptability refers to compared with the control group. The second reason
acceptable color change of restoration, and is within the may be the thickness of material, because lower thick-
range of PT and unacceptable color mismatch.9 Regard- ness is associated with higher translucency.39 The surface
ing TP, the results showed that orthodontic treatment treatments and debonding processes followed by the
changed the TP after CTC irrespective of the type of sur- final finishing and polishing might have decreased the
face treatment. TP significantly increased from t0 to t2, specimen thickness and increased the translucency.
and the share of CTC after orthodontic treatment in this In the present study, only one type of polishing kit
increase was lower than the share of orthodontic treat- and method on a limited thickness of zirconia was eval-
ment alone. Lower share of CTC in alterations of TP was uated. Moreover, this study had an inherent limitations
in line with the findings of a review study by Papageor- of in vitro study design which could not take intraoral
giou-Kyrana et al.,4 who showed that irrespective of the factors such as oral hygiene, saliva, pH, and tempera-
type of zirconia, the effect of aging was insignificant ture into account. Also, both surfaces of zirconia were
and below the AT and PT in thicknesses over 0.5 mm. stained in our study whereas in a clinical environment,
A significant increase in TP was also noted in the con- only one surface would be stained as the other surface
trol specimens after CTC in the present study, although would be bonded to a tooth. Thus, an in vivo study is
the ∆TP in the control group was significantly lower warranted to further evaluate the color properties using
than that in the test groups. The ∆TP in different sur- different polishing techniques on various thicknesses of
face treatment groups before and after CTC (T0 to T2) zirconia.
was lower than AT and higher than PT; while, ∆TP was
lower than PT in the control group (0.1 ± 0.02). This CONCLUSIONS
finding highlighted the significant effect of orthodon-
tic treatment on susceptibility of zirconia to change in Within the limitations of this in vitro study, it may be
translucency following aging. The increase in TP was in concluded that orthodontic treatment makes zirconia
line with the reduction in L* parameter. According to the restorations susceptible to discoloration and increased
Lambert’s law, decreasing the thickness decreases light translucency. Of the groups evaluated in the present
absorption and subsequently increases light transmis- study, the APA group showed minimum and the control
sion.33 group showed maximum color stability. No significant
Similar to the present study, several other studies re- difference was noted in color stability of laser and CoJet
ported that the discoloration of zirconia due to CTC or groups. Moreover, maximum increase in translucency
UV aging alone or CTC following clinical adjustment was noted in the CoJet and APA groups while minimum
was lower than AT,1,9,12,13,37 and showed that translucency change was recorded in the control group followed by
increased with aging and also with increased frequency the laser group. Nonetheless, the color change and al-
of thermal cycles.7,8,12,31 Conversely, Turgut9 reported that terations in translucency did not exceed the AT in any
the translucency of monolithic zirconia decreased by 1.8 group at any time point.
to 6.0 units due to UV aging. Al-Zordk and Saker37 re-
ported a reduction in translucency between 0.42 to 1.51 FUNDING
units due to clinical adjustment and subsequent CTC.
Variations in the results can be due to the use of differ- Dental sciences research center of Guilan Univer-
ent types of zirconia and different aging protocols. sity of medical sciences (Grant number #IR.GUMS.
The present results indicated that all test groups un- REC.1399.223).
der orthodontic treatment had higher translucency than
the control group after CTC. This finding may be due to ACKNOWLEDGEMENTS
two reasons. The first reason may be the higher surface
roughness of specimens that underwent orthodontic Our grateful thanks are extended to Dr. Mohammad
treatment. It has been demonstrated that smoother sur- Ebrahim Ghaffari with a PhD degree in Biostatistics for
faces have higher light reflection, less passage of light, his help in doing the meteorological data analysis.
and lower translucency.38,39 Surface roughness can affect
the translucency of monolithic CAD/CAM restorations AUTHOR CONTRIBUTIONS
such as zirconia.40 Moreover, it has been demonstrated
that despite polishing after orthodontic treatment, the Conceptualization: YBH. Data curation: NS, AMN.
8 https://doi.org/10.4041/kjod22.144 www.e-kjo.org
Babaee Hemmati et al • Orthodontic treatment and zirconia restorations
Formal analysis: AMN. Funding acquisition: YBH. Meth- odontic treatment in specialist practice. J Orthod
odology: MF, HNA. Project administration: MF. Visual- 2019;46:46-50.
ization: HNA. Writing–original draft: NS. Writing–review 11. Abuelenain DA, Linjawi AI, Alghamdi AS, Alsadi
& editing: YBH, MF. FM. The effect of various mechanical and chemi-
cal surface conditioning on the bonding of orth-
CONFLICTS OF INTEREST odontic brackets to all ceramic materials. J Dent Sci
2021;16:370-4.
No potential conflict of interest relevant to this article 12. Arif R, Yilmaz B, Johnston WM. In vitro color stain-
was reported. ability and relative translucency of CAD-CAM restor-
ative materials used for laminate veneers and com-
REFERENCES plete crowns. J Prosthet Dent 2019;122:160-6.
13. Alp G, Subasi MG, Johnston WM, Yilmaz B. Effect
1. Subaşı MG, Alp G, Johnston WM, Yilmaz B. Effects of surface treatments and coffee thermocycling on
of fabrication and shading technique on the color the color and translucency of CAD-CAM monolithic
and translucency of new-generation translucent glass-ceramic. J Prosthet Dent 2018;120:263-8.
zirconia after coffee thermocycling. J Prosthet Dent 14. Mokhtarpur H, Nafisifard M, Dadgar S, Etemadi A,
2018;120:603-8. Chiniforush N, Sobouti F. Shear bond strength of
2. Asli HN, Rahimabadi S, Falahchai M. Flexural the metal bracket to zirconium ceramic restoration
strength of monolithic zirconia after different sur- treated by the Nd: YAG laser and other methods:
face treatments. World J Dent 2019;10:264-9. an in vitro microscopic study. J Lasers Med Sci
3. Babaee Hemmati Y, Neshandar Asli H, Falahchai M, 2020;11:411-6.
Safary S. Effect of different surface treatments and 15. Ameli N, Talaei R, Saeedi S, Ghorbani R, Askari BA.
orthodontic bracket type on shear bond strength Effect of two polishing systems on color and sur-
of high-translucent zirconia: an in vitro study. Int J face roughness of feldspathic porcelain following
Dent 2022;2022:9884006. orthodontic bracket debonding and composite resin
4. Papageorgiou-Kyrana K, Fasoula M, Kontonasaki E. removal. APOS Trends Orthod 2019;9:105-10.
Translucency of monolithic zirconia after hydrother- 16. Cetik S, Ha TH, Sitri L, Duterme H, Pham V, Atash R.
mal aging: a review of in vitro studies. J Prostho- Comparison of shear strength of metal and ceramic
dont 2020;29:489-500. orthodontic brackets cemented to zirconia depend-
5. Elsaka SE. Optical and mechanical properties of ing on surface treatment: an in vitro study. Eur J
newly developed monolithic multilayer zirconia. J Dent 2019;13:150-5.
Prosthodont 2019;28:e279-84. 17. Queiróz Tavares ML, Elias CN, Nojima LI. Effects
6. Babaee Hemmati Y, Neshandar Asil H, Falahchai M, of different primers on indirect orthodontic bond-
Safari N. Comparative effects of tungsten, diamond ing: shear bond strength, color change, and enamel
burs and laser for residual adhesive removal after roughness. Korean J Orthod 2018;48:245-52.
orthodontic debonding on flexural strength, sur- 18. Trakyali G, Ozdemir FI, Arun T. Enamel colour
face roughness and phase transformation of high- changes at debonding and after finishing proce-
translucent zirconia: an in vitro study. Int Orthod dures using five different adhesives. Eur J Orthod
2022;20:100665. 2009;31:397-401.
7. Kim HK. Optical and mechanical properties of 19. Gorucu-Coskuner H, Atik E, Taner T. Tooth color
highly translucent dental zirconia. Materials (Basel) change due to different etching and debonding pro-
2020;13:3395. cedures. Angle Orthod 2018;88:779-84.
8. Sulaiman TA, Abdulmajeed AA, Donovan TE, Vallittu 20. Ye C, Zhao Z, Zhao Q, Du X, Ye J, Wei X. Compari-
PK, Närhi TO, Lassila LV. The effect of staining and son of enamel discoloration associated with bond-
vacuum sintering on optical and mechanical proper- ing with three different orthodontic adhesives and
ties of partially and fully stabilized monolithic zirco- cleaning-up with four different procedures. J Dent
nia. Dent Mater J 2015;34:605-10. 2013;41 Suppl 5:e35-40.
9. Turgut S. Optical properties of currently used zirco- 21. Zaher AR, Abdalla EM, Abdel Motie MA, Rehman
nia-based esthetic restorations fabricated with dif- NA, Kassem H, Athanasiou AE. Enamel colour
ferent techniques. J Esthet Restor Dent 2020;32:26- changes after debonding using various bonding sys-
33. tems. J Orthod 2012;39:82-8.
10. Geoghegan F, Birjandi AA, Machado Xavier G, 22. Boncuk Y, Cehreli ZC, Polat-Özsoy Ö. Effects of
DiBiase AT. Motivation, expectations and under- different orthodontic adhesives and resin removal
standing of patients and their parents seeking orth- techniques on enamel color alteration. Angle Orthod
www.e-kjo.org https://doi.org/10.4041/kjod22.144 9
Babaee Hemmati et al • Orthodontic treatment and zirconia restorations
10 https://doi.org/10.4041/kjod22.144 www.e-kjo.org