You are on page 1of 8
Poa Karl Fischer Moisture Titrator Pe CC eg td CCC ie See See ca Coe ns Refractometer RA-620/-600 ee a eel e Touchscreen operation One of the smallest to fit in A4 size (192 x 281mm) Comes with KEM Refractive Index Standard Liquid Completely ready for use Short warm-up time ASTM :D1218 4 r D1569 Easy operation & maintenace-free D1807 pee D2140 D4056 preety ICUMSA: GS4/3-13 SPS-3 Iso Pak) OIML) = :R124 Display & sound can be customized < 4 BRCM Refractometer RA-620/-600 Accuracy of One of the Highest in the World Accuracy of +0.00002 nD (RA-620). (easement conducted user standard condos of KEM) Reliable measurement with repeatability of +0.00001 nb. Tolerance of Brix of 0.014%. (Catedatea rom accuracy o reactive x Compact Size Benchtop Refractometer (Built-in Temperature Control) Space-saving of A4 Size, Two-thirds of Previous Models in Size (192mmnx281mm) Half of previous models in weight with aluminum die casting housing, Can be installed anywhere in a limited space of lab, Quick Measurement Refractive index, Brix or concentration obtained in a ‘short time: 2 sec. in the shortest. (When limit time is set to 2 sec.) Comes with Refractive Index Standard Liquid (Pure Water) KEM is the only manufacturer of refractometers that also produces the standard liquids. Can be used to evaluate reliability. Image of Cri “1.37625 ical Angle ‘An image of the Abbe measurement scale can be viewed, ee ™ 47-inch TFT Colour LCD & Touch Screen Operation ay view of various into Straightlorvars & User-endly operation, Display colours ‘canbe changed a9 00 1.33346 1m Sample Cover Equipped with Anti Volatilization Device ‘Ant Voatilzaton Device Fisheden ase sample corte pret sane tm wang Splash Preventon ‘Spl cov, when ope, vrs sap om berg ised on CD. Secure Sar buton ia be actveted when sample cove reas open ll Wide Range of Temperature Control “Temperature contol range ofS ‘Suitable for measurement of high-meling-point petroleum a ll and a (Lower tit subject te ambient temperatures) @ Easy to Clean Sample Stage Easy operation with ample stage at the font. ration Navigator =] Convenient and e3sy-to-olow navigator for eatbration, _-.,, & @ Indicator ‘Concentration range can visually be recognize. 25.01 Equipped with USB Port For data save and wranstrto PC, {Saved in CSV tle) LAN & Browser Controls Easy connection to PC with LAN. Control and data transfer possible through browserin your PC. [No special softare reuited, ™ Conversion to Concentration Upto 100 conversion tables can be stored 2] EEE To check Brix Soman TERE 1. eee PERE Principle of Measurement of Refractive Index Any visible light changes its direction when it passes through a material with a higher refractive index (Ri) to that with a lower refractive index. As the incident ray ? increases, the refractive angle 7 will Increase In accordance with Snell's Law, and when the refractive angle ? reaches the critical angle (=90°), total refraction will occur at the boundary between the prism and the sample In actual measurements by our Refractometers, the light source, the prism (nb sensor CCD are placed as shown in the right figure, and the refractive index can be determined from the 768) and the line CCD address of the boundary (critical angle) between the “light” and “dark” area on the line sensor by detecting the intensity of the reflected light with the CCD sensor, ght seuree Leb you from conducting an accurate measurement. Wipe the sample stage and the prism to clean them. €&S Remaining samples or some other stuff on the sample stage or the prism may prevent Drop a sufficient amount of sample on the prism to cover it entirely. &S The minimum amount required is approx. 0.2mL. A.small amount of sample may result in inaccurate measurement with some samples. Meanwhile, too much sample liquid would make it longer to adjust the temperature and to complete the measurement. Close the sample cover. EY &S Make aur to close the sample over Its important to do so to block the exterior light and to achieve an accurate measurement. Press “Start”. 1.33299 fe Measuring. ‘Start” changes to “Reset” once a measurement has started, Press “Reset” if you wish to stop the measurement. A measurement result appears. Immediately wipe off the sample after measurement and clean the prism and the sample stage. Leaving the sample there for a long time may make it difficult to clean the prism and the sample stage. SS 1.33346 = Start Q What are the features of RA-620/-600? State-of-the-art design that cannot be seen with past models, and user-friendly operation, A even suitable for the first-time users. Q Whats the sample amount required? [A Asample of 0.2mL of more is required 'Q How long does it take to measure one sample? ‘A. Minimum two (2) seconds. (May vary according to samples and ambient conditions.) Q What should | do after a measurement? [A, "the sample's an aqueous solution, wipe it otf with water and ethanol using tissues ora soft clot Ifthe sample isan organic solvent such as toluene, wipe it of with ethanol or acetone. Q Are there any consumables? 1a, Nothing special We recommend, however, that the dustproof iter be cleaned every one to two months If dust persists, replace the fiter. (P/N 12-01576-00-48 Fier Set (10 fiters/se) Q How can | check the measurement accuracy? ‘A. We recommend that our Refractive Index Standard Liquids be used to check the accuracy. Auto Cleaning and Multiple Sample Sampling Unit t Changer DCU-551N z ‘CHD-502N tecunteanes oro [t Iressa calls =, eB} x Thermal Printer > Dot Matrix Printer DP-600 A IDP-100 Optional Refractive Index Standard Liquid KEM is the only manufacturer of refractometers that also produces the standard liquids. Part Code ferns Note (2 bottles per set) Pure Water 61-001-0200-48 1.33299 ‘One set of 2 bottles Isoostane 61-001-0800-48 1.391 ‘Set of pure water and isooctane Cyelohexane 61-001-0400-48 126" Set of pure wator and cyclohexane Dichlorotoluene 61-001-2200-48 1546" Sot of pure water and dishlorotoluene Diberzyl ethor 61-001-0600-48 11563" Set of pure water and dibenzy| ether 1-Bromonaphthalane™ 61-001-0700-48 1.658" Set of pure water and t-bromonaphthal Brix Converted Standard Liquid of Refractive Index Pimratnane | arcade BrxmnDataie | Note(botten per et) | 5 Brix solution 61-001-1100-48 5.°" Brix% 1.340 | Equivalnt to 5 Brix% One set of 2 botles 10 Brix solution 61-001-1200-48 10 Brix% 1.947" | Equivalent to 10 Brix% One set Recommend Consumables and Parts A £2 bottles Printer Roll (rolls) 98-829-00018 For IDP-100 Dot Matrix Printer Ribbon cartridge 938-829-0054 Black, For IDP-100 Dot Matrix Printer Ribbon cartridge 928-829-0548 Spes/set Black, For IDP-100 Dot Matrix Printer Thermal Paper Roll (1Orolls) (69-00522-11-48, For DP-600 Thermal Printer Filter Set 12-01576-00-48 10 fiters/set BICC Cle Me tad LL Main Unit A620 or RA-600 unt AG Adapter = set Syius 39-00444-00-48 “piece Feta ndoe Stance iis) Srnor-o200-48 tet Operation Manual 39-00862-01-48 7 e0py Funetion Descrinton €9-00469-01-48 “e0py Quick Manval 39-00864-01-48 Te0py Warranty 5 Teopy Varies by power supply requirement Measuring Method Detection of Gteal Angle of Optical Retracton ght Source LED Ne Line (688m) Measuring ems Refractive Index, Brix Other Concentrations ‘Measuring Range Refractive Index hD) 1.82000 1.58000 "13200 = 1.7000 Bie 0,00 100.0094 ‘ecurey™ Refractive dex 0) 0.00002 00001 Bie 2001496 (0 65.0%) 0.1% epeatabiy® Refractive Index AD) 0.00001 +£0.0008 Bi 0.007% (<5%) 001% (25%) 01% Resolution Refractive dex 0) 2.00001 2.0001 Bi 001% (<9) 00196125) 01% Temperature Corte! Petier Trermostat 6°C 75°C" “Temperature ndeation Resolution a0 or Minimam Armour of Sample 2m Display “4 7nch ‘Operation “Touchscreen (Gomes wih Sivus) Security Password Protection Data Storage Number of Methods 100 matiods Measurement Rosas 300 aaa Calbraton Revere 20 dat ‘Cheek Recors 20 data External Storage USB Flash Drive Teme. 5.00 75.00°C compensation (automatic compensation by preprogrammed conversion tab) Concentration By Conversion Table 00 aaa Ineraces| aN 1 por for personal computer °C) use1 2 pors (for USB fash eve, M-sle printer, barcode reader. Keyboard Rs-2526 2 pers (or IDP-100, multiple sample change) ‘Ambient Temperature 5-350 ondtions arity {8594 or Below (No condensation alowed) Power Supply ‘AD 100 -240V, S0/G0He (Gomes with AC adapter) Power Consumption 20 (vax 500, in, 10) Dimensions 182, «261 (0) « 16804) mm Wight Ska ‘Export Packing in Dowble Caton Box {GI 9.7ky 560 x 460 (0) x $20 Hmm (May varyin some cases) Materials in Gonnct _ Prism ‘Astieil Sapphire minsamples Sani Sage sussi6 ‘Option Printer (DP-600, 1-100 ‘Sampler 'DOU-S5IN, GHD-SO2N ‘Sortware SOFT-CAP Expandabity —_—_Bareoue Reader Reads sample name, measurement condtons, value of standard quid PC Satware Data Acquistion Sotware ST By KEW = standard measurement condilons. °2 From Al accuracy of resus “3. BY KEM" § standard measurement conditions. Subject to sample properties. “d- Lower it 12°C below ambient. Your Distributor KYOTO ELECTRONICS rca toon SOWIE) eee ces ToRi SCR RR Verte Rta cy www.kyoto-kem.com Pi eee Ue SEL

You might also like