Refractometer
RA-620/-600
ee a eel e
Touchscreen operation
One of the smallest to fit in A4 size (192 x 281mm)
Comes with KEM Refractive Index Standard Liquid
Completely ready for use
Short warm-up time
ASTM :D1218
4 r D1569
Easy operation & maintenace-free D1807
pee
D2140
D4056
preety
ICUMSA: GS4/3-13
SPS-3
Iso Pak)
OIML) = :R124
Display & sound can be customized
< 4 BRCMRefractometer
RA-620/-600
Accuracy of One of the
Highest in the World
Accuracy of +0.00002 nD (RA-620).
(easement conducted user standard condos of KEM)
Reliable measurement with repeatability of +0.00001 nb.
Tolerance of Brix of 0.014%.
(Catedatea rom accuracy o reactive x
Compact Size
Benchtop Refractometer
(Built-in Temperature Control)
Space-saving of A4 Size, Two-thirds of Previous
Models in Size (192mmnx281mm)
Half of previous models in weight with
aluminum die casting housing,
Can be installed anywhere in a limited space of lab,
Quick Measurement
Refractive index, Brix or concentration obtained in a
‘short time: 2 sec. in the shortest.
(When limit time is set to 2 sec.)
Comes with Refractive Index
Standard Liquid (Pure Water)
KEM is the only manufacturer of refractometers that also
produces the standard liquids.
Can be used to evaluate reliability.
Image of Cri
“1.37625
ical Angle
‘An image of the Abbe
measurement scale
can be viewed,ee
™ 47-inch TFT Colour LCD & Touch Screen Operation
ay view of various into
Straightlorvars &
User-endly operation,
Display colours
‘canbe changed
a9
00
1.33346
1m Sample Cover Equipped with Anti Volatilization Device
‘Ant Voatilzaton Device
Fisheden ase sample corte pret sane tm wang
Splash Preventon
‘Spl cov, when ope, vrs sap om berg ised on CD.
Secure
Sar buton
ia be actveted when sample cove reas open
ll Wide Range of Temperature Control
“Temperature contol range ofS
‘Suitable for measurement of high-meling-point petroleum a ll and a
(Lower tit subject te ambient temperatures)
@ Easy to Clean Sample Stage
Easy operation with ample stage at the font.
ration Navigator
=] Convenient and e3sy-to-olow navigator for eatbration,
_-.,, &
@ Indicator
‘Concentration range can visually be recognize.
25.01
Equipped with USB Port
For data save and wranstrto PC,
{Saved in CSV tle)
LAN & Browser Controls
Easy connection to PC with LAN.
Control and data transfer possible through browserin your PC.
[No special softare reuited,
™ Conversion to Concentration
Upto 100 conversion tables can be stored2] EEE To check Brix
Soman TERE
1. eee PERE
Principle of Measurement of Refractive Index
Any visible light changes its direction when it
passes through a material with a higher refractive
index (Ri) to that with a lower refractive index. As
the incident ray ? increases, the refractive angle 7
will Increase In accordance with Snell's Law, and
when the refractive angle ? reaches the critical
angle (=90°), total refraction will occur at the
boundary between the prism and the sample
In actual measurements by our Refractometers, the
light source, the prism (nb
sensor CCD are placed as shown in the right figure,
and the refractive index can be determined from the
768) and the line
CCD address of the boundary (critical angle)
between the “light” and “dark” area on the line
sensor by detecting the intensity of the reflected
light with the CCD sensor,
ght seuree Lebyou from conducting an accurate measurement.
Wipe the sample stage and the prism to clean them.
€&S Remaining samples or some other stuff on the sample stage or the prism may prevent
Drop a sufficient amount of sample on
the prism to cover it entirely.
&S The minimum amount required is approx. 0.2mL.
A.small amount of sample may result in inaccurate
measurement with some samples.
Meanwhile, too much sample liquid would make it longer to
adjust the temperature and to complete the measurement.
Close the sample cover.
EY &S Make aur to close the sample over
Its important to do so to block the exterior light and
to achieve an accurate measurement.
Press “Start”.
1.33299
fe
Measuring.
‘Start” changes to “Reset” once a measurement has started,
Press “Reset” if you wish to stop the measurement.
A measurement result appears.
Immediately wipe off the sample after measurement and clean
the prism and the sample stage.
Leaving the sample there for a long time may make it difficult
to clean the prism and the sample stage.
SS
1.33346
= StartQ What are the features of RA-620/-600?
State-of-the-art design that cannot be seen with past models, and user-friendly operation,
A even suitable for the first-time users.
Q Whats the sample amount required?
[A Asample of 0.2mL of more is required
'Q How long does it take to measure one sample?
‘A. Minimum two (2) seconds. (May vary according to samples and ambient conditions.)
Q What should | do after a measurement?
[A, "the sample's an aqueous solution, wipe it otf with water and ethanol using tissues ora soft clot
Ifthe sample isan organic solvent such as toluene, wipe it of with ethanol or acetone.
Q Are there any consumables?
1a, Nothing special We recommend, however, that the dustproof iter be cleaned every one to two months
If dust persists, replace the fiter. (P/N 12-01576-00-48 Fier Set (10 fiters/se)
Q How can | check the measurement accuracy?
‘A. We recommend that our Refractive Index Standard Liquids be used to check the accuracy.
Auto Cleaning and Multiple Sample
Sampling Unit t Changer
DCU-551N z ‘CHD-502N
tecunteanes oro [t Iressa calls
=,
eB} x
Thermal Printer > Dot Matrix Printer
DP-600 A IDP-100Optional Refractive Index Standard Liquid
KEM is the only manufacturer of refractometers that also produces the standard liquids.
Part Code ferns Note (2 bottles per set)
Pure Water 61-001-0200-48 1.33299 ‘One set of 2 bottles
Isoostane 61-001-0800-48 1.391 ‘Set of pure water and isooctane
Cyelohexane 61-001-0400-48 126" Set of pure wator and cyclohexane
Dichlorotoluene 61-001-2200-48 1546" Sot of pure water and dishlorotoluene
Diberzyl ethor 61-001-0600-48 11563" Set of pure water and dibenzy| ether
1-Bromonaphthalane™ 61-001-0700-48 1.658" Set of pure water and t-bromonaphthal
Brix Converted Standard Liquid of Refractive Index
Pimratnane | arcade BrxmnDataie | Note(botten per et) |
5 Brix solution 61-001-1100-48 5.°" Brix% 1.340 | Equivalnt to 5 Brix% One set of 2 botles
10 Brix solution 61-001-1200-48 10 Brix% 1.947" | Equivalent to 10 Brix% One set
Recommend Consumables and Parts
A
£2 bottles
Printer Roll (rolls) 98-829-00018 For IDP-100 Dot Matrix Printer
Ribbon cartridge 938-829-0054 Black, For IDP-100 Dot Matrix Printer
Ribbon cartridge 928-829-0548 Spes/set Black, For IDP-100 Dot Matrix Printer
Thermal Paper Roll (1Orolls) (69-00522-11-48, For DP-600 Thermal Printer
Filter Set 12-01576-00-48 10 fiters/set
BICC Cle Me tad
LL
Main Unit A620 or RA-600 unt
AG Adapter = set
Syius 39-00444-00-48 “piece
Feta ndoe Stance iis) Srnor-o200-48 tet
Operation Manual 39-00862-01-48 7 e0py
Funetion Descrinton €9-00469-01-48 “e0py
Quick Manval 39-00864-01-48 Te0py
Warranty 5 Teopy
Varies by power supply requirementMeasuring Method Detection of Gteal Angle of Optical Retracton
ght Source LED Ne Line (688m)
Measuring ems Refractive Index, Brix Other Concentrations
‘Measuring Range Refractive Index hD) 1.82000 1.58000 "13200 = 1.7000
Bie 0,00 100.0094
‘ecurey™ Refractive dex 0) 0.00002 00001
Bie 2001496 (0 65.0%) 0.1%
epeatabiy® Refractive Index AD) 0.00001 +£0.0008
Bi 0.007% (<5%) 001% (25%) 01%
Resolution Refractive dex 0) 2.00001 2.0001
Bi 001% (<9) 00196125) 01%
Temperature Corte! Petier Trermostat 6°C 75°C"
“Temperature ndeation Resolution a0 or
Minimam Armour of Sample 2m
Display “4 7nch
‘Operation “Touchscreen (Gomes wih Sivus)
Security Password Protection
Data Storage Number of Methods 100 matiods
Measurement Rosas 300 aaa
Calbraton Revere 20 dat
‘Cheek Recors 20 data
External Storage USB Flash Drive
Teme. 5.00 75.00°C
compensation (automatic compensation by preprogrammed conversion tab)
Concentration By Conversion Table 00 aaa
Ineraces| aN 1 por for personal computer °C)
use1 2 pors (for USB fash eve, M-sle printer, barcode reader. Keyboard
Rs-2526 2 pers (or IDP-100, multiple sample change)
‘Ambient Temperature 5-350
ondtions arity {8594 or Below (No condensation alowed)
Power Supply ‘AD 100 -240V, S0/G0He (Gomes with AC adapter)
Power Consumption 20 (vax 500, in, 10)
Dimensions 182, «261 (0) « 16804) mm
Wight Ska
‘Export Packing in Dowble Caton Box {GI 9.7ky 560 x 460 (0) x $20 Hmm (May varyin some cases)
Materials in Gonnct _ Prism ‘Astieil Sapphire
minsamples Sani Sage sussi6
‘Option Printer (DP-600, 1-100
‘Sampler 'DOU-S5IN, GHD-SO2N
‘Sortware SOFT-CAP
Expandabity —_—_Bareoue Reader Reads sample name, measurement condtons, value of standard quid
PC Satware Data Acquistion Sotware
ST By KEW = standard measurement condilons. °2 From Al accuracy of resus
“3. BY KEM" § standard measurement conditions. Subject to sample properties. “d- Lower it 12°C below ambient.
Your Distributor
KYOTO ELECTRONICS
rca toon
SOWIE)
eee ces ToRi
SCR RR Verte Rta cy
www.kyoto-kem.com
Pi eee Ue
SEL