You are on page 1of 2

HERTZ HGO Series

Compressed Air Filters


HGO 25 - 2700

HERTZ Compressed Air Filters have been designed to answer the current requirements of
compressed air filter world. It enables a more comfortable usage for end user, a better
endurance, higher efficiency with lower pressure drop and more port size options.
General Features
 The air filters have 4 ranges of efficiencies, removing down to 0.01 micron at up to 235
psi (16barg) - 1/4" to 3" NPT/BSP pipe sizes. A protected auto float drain (2 mm orifice) is
standard for reliable removal of liquid contaminants.
 Zero-porosity aluminum and durable epoxy powder-coat finish, along with a corrosion-
resistant internal coating gives long service life.
 Filter combinations are configured to meet specific application requirements.
 Filter complies with PED and performs as per related ISO 8573 standards.
 These filters may be equipped with differentia l pressure gauges for easy maintenance
and energy efficiency. HERTZ highly recommends this option to the customers.
Element Features
HERTZ offers superior protection from 1 micron to 0.01 micron. Durable element
construction and efficient drain layer ensures reliable performance after optimal element
change.
 Deep pleating also enables a lower pressure drop.
 Supreme collapse resistance due to usage of fluted stainless tube provides strength
against pressure drops while improving the performance by passing air diagonally through
the element.
 PVC impregnated foam favors water / oil drainage.
Head Clamping
Head Clamping provides serial connection of filters without any extra piping.
Zero Clearance
The major innovation for inducer is the zero clearance; enables on easier bowl removal
without using tool.
Drainage Ribs
Drainage Ribs favors the humidity flow.
Anodizing
Anodizing provides supreme corrosion resistance. Anodized surface treatment is far better
than other surface treatment methods such as Alocrom coating.
Technical Specifications

Correction Factor
For maximum flow rate, multiply model flow rate shown in the table above
by the correction factor that corresponds to the working pressure.

Notes
 Grade A must not operate in oil saturated conditions.
 Grade A elements should be replaced every six months at most to operate
properly.
 Grade A will not remove certain gases including carbon monoxide and
carbon dioxide.
 Flow rates are based on a 7 bar operating pressure. For other pressure
levels, use correction factor given above to calculate the corrected flow
rate.
 All filter models are suitable for the usage with mineral and synthetic oils.
 Gauge type pressure indicators are fitted to models HGO 25 to HGO 2700
as a standard.
 All filters are in conformity with the Pressure Equipment Directive
(97/23/EC)