You are on page 1of 10

GRL8004SII Optical

Transmission Platform
GRL8004SII Chassis

Operation Manual

Chengdu KT Electronic Hi-Tech Co., Ltd


1. Brief introduction
1.1 Description

GRL8004SⅡ, isa standard 19-inch wide and, 3RU high optical platform, and has 17 slots. It

supports 15 functional modules in a single power supply and 13 functional modules in dual

power-sharing power supply. This platform supports a variety of functional modules, including

straight dimming 1310nm/1550nm transmitters, EDFAs, optical switches, upstream and

downstream optical receiver, and front-end amplifier. Anti-surge design, hot-swappable

modules; high-density, small size, excellent thermal design, seven removable cooling fan on

backplane that is used to cool the entire the GRL optical transmission platform. There is

large-size LCD display and touch buttons on front panel that the user can view locally and

set the module parameters, which greatly facilitates the maintenance of the equipment. The

platform comes with a network management module, so that users can remote monitor and

adjust the operation of the equipment from the internet. The user-friendly design allows the

user to replace the module without disassembly RF cable maintenance. GRL8004S Ⅱ

becomes one of the best optical platform, and is the ideal choice for network operators.

1.2 Feature
 3RU, 19-inch standard chassis
 High density, one platform can support at most 15 modules
 With 7 groups of separate cooling fans
 Hot-swap
 Can configure dual power supply sharing working mode (backup power supply
occupied 14/15 of the slots)
 Large LCD display on front panel
 Touch buttons
 The user-friendly design allows the user to replace the module without
disassembly RF cable maintenance.
 With network management module

1.3 Specification
Working temperature 0 to 50℃(32 to 122℉)
Storage temperature -40 to 70℃(-40 to 158℉)
Relative humidity Maximum 85% non-condensing
Structure standard chassis. 3RU
Internal space 17 slots
Dimension 482mm(W)×133mm(H)×515mm( D)
Weight 8.3Kg(Including 1 power supply and network management
module)

Specifications may be changed without notice.

2. External Structure

Chassis panel structure please see fig 2.1 and description please see table 2.1
Fig 2.1 GRL8004SⅡ front panel and rear panel

Table 2.1 Panel direction

Item Description Function


1, 12 Handle For rack installation and uninstallation
Power supply and signal transmission between each
2 Backplane
module
For fixing when the front panel flips to vertical
3, 10 Flip latch
position
4 LCD monitor To display parameters of chassis or function module
In and out fiber
5, 8 For input and output optical fiber of module
access hole
6, 7 Sliding lock To fix the position of front panelafter slide
To check or configure parameter of chassis or
9 Touch keys
module by working with LCD
11 Screw hole To fix the chassis
13 Fan Radiating
For the adaption from function module to the input
14 RF adapter
and output cables
15, 16 Power jack For 220V
Network
17 management To fix network management module
fixing screw
Network
18 management To connect PC
RJ45 port
Network
To network management connection and operation
19 management
indication
indicator
Network
20 management Network management box
module box

3. Receiving and inspection

KT has inspected all products before delivery, to avoid mechanical and electronic
defects. When you receive the product, please:
3.1 Check whether product packaging is damaged during transport
3.2 Open the packaging of all modules and chassis
3.3 After opening the package, please keep all packaging materials for future reprint and
storage. If the products are damaged, please contact the shipper and immediately notify KT,
and use the original packaging (or similar function packaging) to send back to KT companies
for maintenance.
4. Precautions

The Manual provides for safety standards in product design, manufacture and use. If
violate these safety precautions, it may cause damage to the equipment, and KT Company
does not undertake any responsibility

Warning: Do not make the module work beyond its maximum rated working conditions. It will
lead to poor product performance and reduce module service life, even dangerous.
Warning: This module working temperature is 0 to 50 º C (32 to 122 º F).
Warning: This module storage temperature is -40 to +70 º C (-40 to +158 º F), relative
humidity is 85% (non-condensing), and away from sources of ignition and corrosive
substances.

5. GRL8004SⅡ installation and setting


Precautions:
For the chassis with full modules is very heavy, it requires two people to install. We
suggest that user can should install chassis first when there are not moduleswith no
modules. To install GRL8004SⅡ to a standard chassis, refer to the following steps:
Fig 5.1 Install chassis to 19-inch rack
5.1. Refer to fig 5.1, and pay attention tonotice that:
■Do not block front panel and/or rear panel
■Keep sufficient space both on and below the chassis to allow air to flow
5.2 Keep the GRL8004SⅡ screw holes aligned with that of 19-inch standard rack.
Alignment GRL8004S Ⅱ chassis and 19-inch standard rack screw holes
5.3 Install and tighten the four screws
5.4 Install one power supply module to PWR8004BII. The power module must be
installed in slot 16/17 (For dual power-sharing work need to be installed in slots 14, 15),
tighten the mounting screws, connect back-end power cord of the power supply.
5.5 Open the power switch of GRL8004S Ⅱ power module, then the Power and STA
indicators light (green), and the backplane seven cooling fans start working which shows
that the power supply is operating normally. The power module can be inserted with a
multi-meter table pen to test the output voltage. And the user can check power supply
working parameters by keys on LCD.
5.6 Refer the above steps to install other modules

6. Configure GRL8004SⅡ chassis


6.1 Working temperature range
The working temperature of all modules is 0-50 ºC (32-122 ºF).
6.2 Power consumption
To maintain GRL8004SII operation, it needs at least one PWR8004BII power supply
module. KT PWR8004BII can provide 200W rated output power to meet the power demand in
the rack fully loaded case. The book lists the power requirements for each module, it is
recommended to install a backup power supply module for power redundancy backup.
7. InstallAssemble modules
7.1 Check pin-socketmodule pin type connector on the rear panel of the module, prior to
installation to and ensure make sure that no pins are bent.
7.2 Alignment slot, along the guide slot to put module into the slot of the rack Insert the
module in the rack along the guide slot.
7.3 Tight the screws on the front panel.
7.4 If you need to install other module, repeat steps 1 through to 3.
7.5 The configuration of modules supported by GRL8004S Ⅱ platform, as see table 7.1

Warning: some functional modules are sensitive for surge, please ensure that
GRL8004SⅡ is reliable grounded!
Warning:Force to install the module with a curved PIN feet will damage the
backplane of GRL8004S Ⅱ..
Note: All modules are hot-swap. Modules can be plugged when GRL8004S Ⅱ is
working.
GRL8004SⅡ Platform Module Configuration
Module Type
1310nm downstream laser transmitter module GFB9XX1AⅡ
1550nm directly modulated laser transmitter module GTB9XX1AⅡ
Analog optical fiber amplifier module GABXX02 series
Optical switch module GKB8201BⅡ
Optical receiver module GSB921BⅡ
Headend amplifier RSBY930DCⅡ
Power supply module PWR8004BⅡ
Equipment management module NE8004SⅡET

8. LCD and keys of optical platform


8.1 LCD of the optical platform is a low power 20 × 2 blue and white LCD module
8.2 Optical platform keys, including "↑", "↓" "←"and "→" four arrow keys and a
confirmation key "OK" and cancel key "ESC".

8.3 Check optical platform information


1)When the platform is powered on, the first interface shows that the LCD
initialization is complete, press the "↑" to enter the function menu
2)5 primary menus respectively display NET SETUP, SLOT SELECT, POWER
STATUS, FAN STATUS. The user can make cycle selection of the various menu by the "↑" or
"↓".
3)NET SETUP menu is used to set network parameters. When select this menu, you
can press "OK" button to enter the menu setting options. NET SETUP contains 3 secondary
menus, including IP Address, Submask Address, Gateway Address. The user can cycle
through the three options by "↑" or "↓" , and can also press the "ESC" to exit the menu. When
you select one of the options, press "OK" to enter the option parameter settings, press "↑" or
"↓"to select the position of the parameters that need to be modified, press "←" or "→" key to
reduce or increase the values of the parameters, and finally click "OK" to complete settings or
"ESC" to exit the settings.
4)SLOT SELECT menu is for slot selection. Select the menu and press "OK" to
enter the slot selection menu, "SOLT SELECE 【1】" small box flashing number is the
currently selected slot, users press "←" or "→" to achieve clockwise selection of slot and
counterclockwise. When select the slot and press "OK" button to enter the module option.
5)POWER STATUS Menu is used for platform power information display. Choose to
go to the menu, press "OK" to enter the power parameter module information (if configured
with dual power supply, press the "˄" and "˄" keys to achieve power1 and 2 switching). The
information includes 6 parameter options: power supply voltage, current, fan work, the box
body temperature, slot reset, and restore the factory settings. Users press "↑" or "↓" key to
cycle through the various parameters.
6) FAN STATUS menu is used for fan work status display. Select the menu and
press "OK" to enter the fan display menu, the user can press "↑" or "↓" key to cycle through
the various parameters. In the case of the fan is working properly, the display information as
follows: FAN1: ON, first fan is working properly, fan error or fan damaged shows as: FAN1:
OFF, the end connected to network management software NEL8004S Ⅱ ET will issue the
corresponding alarm signal. For fan is important to the cooling, if the fan is damaged, please
immediate replace the fan with the same model fan, to ensure the stability of the platform.
7)If the user does not have any operating, LCD will turn off the backlight in 2.5
minutes. The user may need to operate when by pressing the "←" and "ESC" key to
immediately turn off the LCD backlight.
8.4 Function iInterface Screen captures and operation steps
Chengdu KT Electronic Hi-tech Co., Ltd
Add: No.9, 3rd East Wuke Road, Wuhou District, Chengdu Zip code: 610045
Tel:(028)85360759 Fax:(028)85369640