You are on page 1of 21

DHP200D DTV Headend Processor User Manual

DHP200D DTV Headend Processor


User Manual

DEXIN DIGITAL TECHNOLOGY


20142014 CORP. LTD.

1
DHP200D DTV Headend Processor User Manual

About This Manual


Intended Audience

This user manual has been written to help people who have to use, to integrate and

to install the product. Some chapters require some prerequisite knowledge in

electronics and especially in broadcast technologies and standards.

Disclaimer

No part of this document may be reproduced in any form without the written

permission of the copyright owner.

The contents of this document are subject to revision without notice due to

continued progress in methodology, design and manufacturing. DEXIN shall have

no liability for any error or damage of any kind resulting from the use of this

document.

Copy Warning

This document includes some confidential information. Its usage is limited to the

owners of the product that it is relevant to. It cannot be copied, modified, or

translated in another language without prior written authorization from DEXIN.

2
DHP200D DTV Headend Processor User Manual

Directory

Chapter 1 Product Overview ............................................................................................................ 1


1.1 Outline ........................................................................................................................................... 1
1.2 Features ......................................................................................................................................... 1
Principle Chart (Example: one 64qam card + one 48qam card) ................................................... 2
1.4 Appearance and Description ....................................................................................................... 3
Chapter 2 Installation Guide ............................................................................................................. 5
2.1 General Precautions ..................................................................................................................... 5
2.2 Power precautions ........................................................................................................................ 5
2.3 Device’s Installation Flow Chart Illustrated as following ........................................................ 5
2.4 Environment Requirement .......................................................................................................... 5
2.5 Grounding Requirement.............................................................................................................. 6
2.6 Frame Grounding ......................................................................................................................... 6
2.7 Device Grounding ......................................................................................................................... 7
2.8 Wire’s Connection ........................................................................................................................ 7
2.9 Power cord connection ................................................................................................................. 7
2.10 Signal and NMS Cable Connection .......................................................................................... 7
Chapter 3 Web NMS Management .................................................................................................. 8
3.1 Login .............................................................................................................................................. 8
3.2 Operation ...................................................................................................................................... 8

3
DHP200D DTV Headend Processor User Manual

Chapter 1 Product Overview

1.1 Outline

DHP200D 10G IP QAM processor is an all-in-one device developed by

DEXIN which integrates multiplexer, scrambler and modulator in one

body with maximum 112 DVB-C QAM channels output. With 10G switch

built in, it can process 10G optical signal to work as a traditional QAM

modulator.

This processor is equipped with 2 card slots to load 32ch or 48ch or 64ch

QAM card. Its high density helps operators to save cost to the most extent.

1.2 Features
* Support 3 SFP+(10G)/SFP(1G) ports and 2 GE ports input & output from the front panel, or
RJ45 GE ports input & output from daughter cards (32/48QAM)
* High density, modularized plug-in design, 1U chassis with max 2 QAM cards
* Support multiplexer and scrambler with 6 CAS Simul-cryption
* Maximum 112 non-adjacent QAM carriers output
* Supports accurate PCR adjusting/CA filtering, PID remapping and PSI/SI editing
* Web-based Network management

1
DHP200D DTV Headend Processor User Manual

Principle Chart (Example: one 64qam card + one 48qam card)

Carrier 1 Card 1
GE MUX 1# SCR 1# QAM 1#
IP 10G
Carrier 1~32
SFP+/SFP1

Carrier 32 RF out 1
GE
MUX 32# SCR 32# QAM 32#
512 IP in
IP 10G
SFP+/SFP2 64 IP out
Carrier 33
GE MUX 33# SCR 33# QAM 33#
Carrier 33~64

IP 10G
SFP+/SFP3 RF out 2
GE MUX 64# SCR 64# QAM 64# Carrier 64

Switch

IP GE1 Card 2
Carrier 1
GE MUX 1# SCR 1# QAM 1#
512 IP in Carrier 1~24

IP 48 IP out
GE2 RF out 1
GE Carrier 24
MUX 24# SCR 24# QAM 24#

Carrier 25
IP Data 1 MUX 25# SCR 25# QAM 25#

2*512 IP in Carrier 25~48


QAM Card
48 IP out RF out 2
IP
Data 2 MUX 48# SCR 48# QAM 48# Carrier 48

Carrier Setting Illustration (Example: 64qam card)

CH 1 CH 5 CH 31 CH 32 CH 33 CH 36 CH 63 CH 64
……… ………

384M 384M
Start Frequency End Frequency Start Frequency End Frequency
RF1 RF2

1.3 Tech Specifications


Input from Front Panel Max 512 IP in per card through SFP+/SFP ports 1-3 and 2 GE ports
Input from Daughter Card 2*512 IP in from 2 GE ports (SFP port optional)--32/48 QAM
Input
Transmission Rate Max 9600Mbps for each 10G SFP+/SFP input
Transport Protocol TS over UDP/RTP, unicast and multicast, IGMP V2/V3
Max PIDs Remapping 256 per output channel
PID remapping (auto/manually optional)
Mux
Functions PCR accurate adjusting
PSI/SI table automatically generating
Max simulcrypt CA 6
Scrambling Scramble Standard ETR289, ETSI 101 197, ETSI 103 197
Connection Local/remote connection

2
DHP200D DTV Headend Processor User Manual

Modulation Standard EN300 429/ITU-T J.83A/B/C


Constellation: 16/32/64/128/256QAM
J.83A
Bandwidth: 8M
Constellation
Constellation: 64/256QAM
J.83B/C
Bandwidth: 6M
Modulation 32/48/64/96/112 non-adjacent carriers output,
QAM Channel
384Mbps bandwidth for each RF port
3600~7000Ksps, 1ksps stepping
Symbol Rate
5057Ksps (J.83B, 64QAM) ; 5361Ksps (J.83B, 256QAM)
Constellation 16, 32, 64, 128, 256QAM
FEC RS (204, 188)
1 or 2 F type output ports for 32/48/64 carriers card, 75Ω.
32ch qam card : all Carrier out thru one RF port
Interface (per card) 32ch/48ch qam card: Carrier 1~16/1~24 out thru RF1,
17~32/25~48 thru RF2
RF Output
64ch qam card: Carrier 1~32 out thru RF1, 33~64 thru RF2
RF Range 50~960MHz, 1kHz stepping
Output Level -20dBm~+10dBm(87~117dbµV), 0.1dB stepping
MER ≥ 40dB
32/48/64 IP output over UDP/RTP/RTSP, unicast/multicast,
TS output Per Daughter QAM Card
through SFP+/SFP ports 1-3 or GE ports RJ45
System Web-based Network management
Dimension 420mm×440mm×44.5mm (WxLxH)
Temperature 0~45℃(operation), -20~80℃(storage)
General
Power Supply AC 100V±10%, 50/60Hz; or AC 220V±10%, 50/60Hz
Consumption 50W(1 daughter QAM card)/75W(2 daughter QAM cards)

1.4 Appearance and Description

Panel Illustration

2 3
1

Module 1 Module 2

4 5 6

3
DHP200D DTV Headend Processor User Manual

1 2 GE ports for data input/output


2 3 SFP+ (10G)/SFP(1G) ports for 10G optical signal input
NMS: network management system port
3
CAS: Conditional Accesss System port
4 Power Switch and supply
5 32/48 QAM module with RF out ports and GE ports for data input/output
6 Fixed 64 QAM module with RF out ports

4
DHP200D DTV Headend Processor User Manual

Chapter 2 Installation Guide

This section is to explain the cautions the users must know in some case that possible injure
may bring to users when it‟s used or installed. For this reason, please read all details here and
make in mind before installing or using the product.

2.1 General Precautions


 Must be operated and maintained free of dust or dirty.
 The cover should be securely fastened, do not open the cover of the products when the power is
on.
 After use, securely stow away all loose cables, external antenna, and others.

2.2 Power precautions


 When you connect the power source, make sure if it may cause overload.

 Avoid operating on a wet floor in the open. Make sure the extension cable is in good condition
 Make sure the power switch is off before you start to install the device

2.3 Device’s Installation Flow Chart Illustrated as following

Connecting
Grouding Connecting
Acquisition Installing Setting Running
Wire and Signal
Check Device Parameter Device
Power cable
Cord

2.4 Environment Requirement


Item Requirement

When user installs machine frame array in one machine hall, the
Machine Hall Space distance between 2 rows of machine frames should be 1.2~1.5m
and the distance against wall should be no less than 0.8m.
Electric Isolation, Dust Free
Machine Hall Floor Volume resistivity of ground anti-static material:

1X107~1X1010,Grounding current limiting resistance: 1M

5
DHP200D DTV Headend Processor User Manual

(Floor bearing should be greater than 450Kg/㎡)

Environment 5~40℃(sustainable ),0~45℃(short time),


Temperature
installing air-conditioning is recommended
Relative Humidity 20%~80% sustainable 10%~90% short time
Pressure 86~105KPa
Installing rubber strip for sealing door-gaps and dual level glasses
Door & Window
for window
Wall It can be covered with wallpaper, or brightness less paint.
Fire Protection Fire alarm system and extinguisher
Requiring device power, air-conditioning power and lighting
power are independent to each other. Device power requires AC
Power
110V±10%, 50/60Hz or AC 220V±10%, 50/60Hz. Please
carefully check before running.

2.5 Grounding Requirement


 All function modules‟ good grounding is the basis of reliability and stability of devices. Also, they
are the most important guarantee of lightning arresting and interference rejection. Therefore, the
system must follow this rule.

 Grounding conductor must adopt copper conductor in order to reduce high frequency impedance,
and the grounding wire must be as thick and short as possible.

 Users should make sure the 2 ends of grounding wire well electric conducted and be antirust.
 It is prohibited to use any other device as part of grounding electric circuit
 The area of the conduction between grounding wire and device‟s frame should be no less than
25 mm2.

2.6 Frame Grounding

All the machine frames should be connected with protective copper strip. The

grounding wire should be as short as possible and avoid circling. The area of the

conduction between grounding wire and grounding strip should be no less than

25mm2.

6
DHP200D DTV Headend Processor User Manual

2.7 Device Grounding

Connecting the device‟s grounding rod to frame‟s grounding pole with copper wire.

2.8 Wire’s Connection

2.9 Power cord connection

The power socket is located on the right of rear panel, and the power switch is on

the left of front panel. User can plug one end of the power cord to the socket and

insert the other end to AC power. When the device solely connects to protective

ground, it should adopt independent way, say, share the same ground with other

devices. When the device adopts united way, the grounding resistance should be

smaller than 1Ω.

Caution: Before connecting power cord to DHP200D DTV Headend Processor,

user should set the power switch to “OFF”.

2.10 Signal and NMS Cable Connection

The signal connections include the connection of input signal cable and the

connection of output signal cable.

7
DHP200D DTV Headend Processor User Manual

Chapter 3 Web NMS Management

This device supports management by web-based NMS.

3.1 Login

The factory default IP address of this device is 192.168.0.136. Users can connect the

device and web NMS through this IP address.

Connect the PC (Personal Computer) and the device with a net cable, and use ping

command to confirm they are on the same network segment. Launch the web browser

an input the device IP address in the browser‟s address bar and press Enter.

It will display the Login interface as Figure-1. Input the Username and Password

(Both the default Username and Password are “admin”. And then click “OK” to start

the device setting.

Figure-1

3.2 Operation

3.2.1 Summary
When we confirm the login, it will display the summary interface as Figure-2 where users have an
over view of the system information and alarm log.

8
DHP200D DTV Headend Processor User Manual

User can click any item


here to enter the
corresponding interface
to check information or
set the parameters.
Figure-2

3.2.2 Monitor

Monitor → Module 1:

Clicking “Module 1”, it will display the interface as Figure-3 where users can check the input

status of Module 1.There are 7 input port, including 2 GE ports and 3 SFP ports at front panel,

also 2 GE ports at Module 1.

Figure-3

3.2.3 Parameters

9
DHP200D DTV Headend Processor User Manual

 Mudule 1/2
Click “Module 1 (or 2)”, it displays the interface as Figure-4 where users can configure the input IP
stream and multiplex channels to output. (Module 1 can be 32ch or 48ch QAM or blank as per order
config, while Module 2 is fixed to allow only 64ch QAM loaded or blank.)
Mux:

Task bar, click and enter each


tag to configure

Output Area: to set


Input Area: click this
parameters for the
button to add services selected and output
services

Operation Area

Figure-4

Click “+” to add IP input, then select one channel to parse, it will display the interface where users
can choose the programs to Mux out. (Figure-5)

Set IP input address

10
DHP200D DTV Headend Processor User Manual

Figure-5

Configure „Input Area‟ and „Output Area‟ with buttons in „Operation Area‟. Instructions are as
below:
: To add input channel which come from Module GE1, Module GE2

: To edit the input channel

: To delete the input channel


: To delete all inputs channel
: To check input IP lock or not, green means current IP locked
: To check current TS overflow or not, red color means current TS overflow, need
reduce program

:Enable/disable the CA Filter function. Clicking the box, user can filter the input CA to

avoid disturbing with the device scrambling function.


: To enable/disable the PID remapping

To refresh the input program information

To refresh the output program information

Select one input program first and click this button to transfer the selected program to
the right box to output.

Similarly, user can cancel the multiplexed programs from the right box.
To select all the input programs
To select all the output programs

To parse programs time limitation of parsing input programs

General:

Click “General”, it displays the interface where users can set parameters for each output channel

11
DHP200D DTV Headend Processor User Manual

Figure-7

PID Pass:
Clicking “PID pass”, it will display the interface as Figure-8 where user can add PIDs to be passed,
click the “+” symbol, input current IP channel number, then input current IP source PID and output
PID which is customer needed , then click “set” to apply the parameters.

12
DHP200D DTV Headend Processor User Manual

Figure-8

Scrambler:
Clicking “Scrambler”, it will display the interface where users can choose the programs to scramble.
(Figure-8)

Scramble channel select


carrier select
CA channel select

EMMG and ECMG


working state, green
means it work
normally, while red
This field indicates the
means communication
current outputting programs.
error or no
The programs selected will
communication.
be scrambled.

Figure-8
IP Stream:
Module 1 (32ch qam module or 48ch qam module) supports TS to output in IP format through the
GE 1 & GE2 ports.
Click “IP Stream”, it displays the interface as Figure-9 where to set IP out parameters.

13
DHP200D DTV Headend Processor User Manual

Quickly Config

Figure-9

Modulator:
Clicking “Modulator”, it will display the interface as Figure-10 where to set RF output parameters.

Click “quickly
config” to set all
channels RF QAM
output parameters

Click “ Channel
config” to set each
channel RF QAM
output parameters

Figure-10

System:
Clicking “System”, it will display the interface as Figure-11 where to set network parameters.

14
DHP200D DTV Headend Processor User Manual

Figure-11

Module 2 all setting, please refer to Module1

3.2.4 System

System → Port Control:


Clicking “Port Control”, it will display the interface as Figure-12 where to set network parameters.

Figure-12
System → Network:
Clicking “Network”, it will display the interface as Figure-13

15
DHP200D DTV Headend Processor User Manual

Login this IP address for


management this device

Figure-13

System → Account
Clicking “Account”, it will display the screen as Figure-14 where to set the login account and
password for the web NMS.

Figure-14

System → Configuration:
Clicking “Configuration”, it will display the screen as Figure-15 where to set your configurations
for the device.

16
DHP200D DTV Headend Processor User Manual

Select areas

Figure-15
System → Firmware:
Clicking “Firmware”, it will display the screen as Figure-16 where to update firmware for the
device.

Figure-16
System → Date/Time:
Clicking “Date/Time”, it will display the interface as Figure-17 where users can set date/time for
this device.

17
DHP200D DTV Headend Processor User Manual

Figure-17

18

You might also like