0% found this document useful (0 votes)
892 views1 page

15-032!00!034 - Fire Protection System Ground Floor Plan Part-3

Uploaded by

Amit Biswas
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
892 views1 page

15-032!00!034 - Fire Protection System Ground Floor Plan Part-3

Uploaded by

Amit Biswas
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

A EcoBlue Limited A
Siam Eastern Industrial Park,Moo 3,
Tambol Plyakdaeng, Pluakdaeng District,
Rayong 21140
Thailand
Tel: 038-627-074 ext. 681

B B

TIP TECH Engineering Co.,Ltd


99/3, Moo 5, [Link]
Ayutthaya - Ang Thong Road,
[Link] Nakorn Sri Ayutthaya 13000
Thailand
E-mail : Info@[Link]

Engineering Co.,Ltd

C C

1 2 3 4 5 6 7 8 9 10 11 FOR TENDER
FP. ø150 FP. ø150
FP. ø150

FP. ø150
G
FHC
D D
F ø100 TO FHC

01 2021-04-20 FOR TENDER


00 2021-03-31 FOR TENDER
REV DATE DESCRIPTION REMARK

PROJECT

EB PROJECT ONE
E E

H NOTE AND KEY PLAN

F F

I EL. +0

TBD-
Cont r ol
Room

Temple

EL. +0
Pipe rack, w
idt h 1
000m m
Load= 25 0 kg/ r u
nning m

G S S -P 1

O u te
l t S o
1 5 m3

S S -P 2
O u te
li

l t S o
li S n
e
rc C re
g
n
a
h E rx
t re
d
u
UP
LAB
T Rand
C ONFemale- Toilet
OLTBD R OOMfo r Male &

CU R
E
T
1 5 m3

C
L

Engineerin g
Store
C re
tu C m
o ro
tc
a
p

G
IU
L
A
N
R
P
D "1

Crys tal i ze r
6x 6=36m 2

0.9m

5.5m

9.1m

1.2m
+0. 0m m

2.6m

O U T O

O U T O

O U T O
C A P .B A
3 0 kV A

C A P .B A
3 0 kV A

C A P .B A
2 0 kV A

C A P .B A
8 0 kV A

G G

G G

G G
R

IN 4

IN 5

IN 6
Co ol in g Uni t Co ol in g Uni t

N K

N K

N K

N K
6 x 7.5 = 4 5 m 2 6 x 7.5 = 4 5 m 2

0. 9m

9. 1m

1. 2m

L V M
IN C O M

O U T O

O U T O

O U T O

B U S
5. 5m

B U S

L V M
L V M

D B

C U

O U T
C U

1
IN G

G G

G G

G G

D B
O P

F O

B A K
D B

O P

IN 1

IN 2

IN 3

1
L E 2R

R T

G IO
1

L E 1R

N G

C
O U T 4
F O

B A K
R T

G IO
N

N G

C
5

400Kg/hr
VAPORI ZER
DN
SSP Area

2. 6m
ELECTRICAL CONTROL
PANEL

L V D
M B
2
B U S
C O
U P
L E 4R

C A P .B A
N K
3 0 kV A
R
TOI LE T W OR K S H OP STEAM
HEADER
BLOWDOWN
C A P .B A
N K
3 0 kV A
R TANK
PUMP

1 3.7
C A P .B A
N K

Crys tal i ze r 2 0 kV A
R

ELECTRICAL CONTROL

MIN.
6x 6=36m 2
PANEL
C A P .B A
N K
8 0 kV A
R

m
O U G
T O IN G 1 0

O U G
T O IN G 1 1
AIR
DRYER

SLAB
R. C

Li t er s
LNG I SO TANK C A
UP WTP PUMP
L V D
M B
2
R A IS
E R B U S
D C
U T

EL+
(TBC

0. 30

SLAB
R. C
DIMENSION)

EL+
PAC I TY 45, 000
BOILER

0. 30
1 3.7
M a i n Entry HTM
CHEMICAL
AIR RECEIVER EXPANSION TANK

MIN.
fro m He re AIR TANK
TANK 2680 LITER

m
COMPRESSOR
CHILLER
PUMP DRAIN TANK
TRANSFORMER TRANSFORMER 3250 LITER

DEARATOR

EL. -300

PATH OF FRONT
WHEEL PATH OF FRONT

PATH OF REAR
OVERHANG
PATHWOF

°90
WHEEL PATH OF REAR
HEEL
OVERHANG
PATH OF

° 90
W HEEL
H H
FP. ø150

FHC ARCHITECTURAL:

ณรงค์ฤทธิ วีระกุล ส.สถ. 2679


พิชญ์ งามอุดมเกียรติ ภ สถ. 21914
J FP. ø65 J
FP ø65(T/A) STRUCTURAL ENGINEERS:
FP. ø150
F ø100 TO FHC
FHC ประพจน์ อัตตธรรมรัตน์ สย.9871
ธีราพร จันทะดวง ภย.63602
K วรัญญา เหล่าวัฒนา ภย.67147
ELECTRICAL ENGINEERS:

FP ø150 FROM FIRE RING MAIN ณัฐชนก นันท์ชยั สฟก.5680


FP ø150 RISER TO FHC

K K
FIRE PROTECTION SYSTEM GROUND FLOOR PLAN PART-3 MECHANICAL ENGINEERS:
1
1 : 100 ปฏิวตั ิ อุระศิลป์ สก.2949
นพสันต์ เหรียญเสนะพงศ์ ภก.27855
วรพันธุ์ แก้วประจบ ภก.33427
SANITARY ENGINEERS:

ปฏิวตั ิ อุระศิลป์ สก.2949


LEGEND :
วรพันธุ์ แก้วประจบ ภก.33427

: FIRE EXTINGUISHER ABC TYP, 6A:20B TITLE


L L
: FIRE EXTINGUISHER CO2 TYP, 5 kg. FIRE PROTECTION SYSTEM GROUND
FLOOR PLAN PART-3
: FIRE HOSE CABINET INDOOR FLOOR MOUNTED TYPE
W / FIRE EXTINGUISHER ABC TYPE

DRAWN CHECKED APPROVED


: FIRE HOSE CABINET OUTDOOR FLOOR MOUNTED TYPE
W / FIRE EXTINGUISHER ABC TYPE
Worrapan K. Noppasunt H. Patiwat U.

: FIRE HOSE CABINET OUTDOOR FLOOR MOUNTED TYPE


M W / FIRE HYDRANT CONNECTION 150x65x65 DRAWING NUMBER SCALE SHEET M
15-032-00-034 1 : 100 1

A1_841x594 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
@ Copyright TIP TECH Engineering Co.,LtdAll rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means without permission of the publisher.

: FIRE EXTINGUISHER ABC  TYP, 6A:20B
: FIRE HOSE CABINET INDOOR FLOOR MOUNTED TYPE
  W / FIRE EXTINGUISHER ABC TYPE
LEGEND :