The method to be used at the Instituto del Corazón de Bucaramanga S.A. for the opening
of the packages of disposable cardiovascular models
cardiovascular models, is the open technique through the manual method with sterile
gloves, since the packaging of the disposable
sterile gloves, since the packaging of the disposable packages is generally made of
medical grade paper, tyvek or
medical grade paper, tyvek paper or paper bags and impermeable industrial
polypropylene.
PRECAUTIONS Y RECOMMENDATIONS GENERAL PRECAUTIONS
DESCRIPTION OF ACTIVITIES
Place the package on a clean and dry surface dry surface (sterile stock table), in
the center of the center of the table.
With clean and dry hands, puncture the seal of the outer
seal of the outer wrapping of the sterile packagesterile package at one end.
Slide the contents of the package onto the reserve table.
Proceed to the application of sterile gloves using the
sterile gloves using the open-technique glove gloves with open technique.
The contents of the package are protected
generally in SMS disposable cloth or in reinforced polyethylene
reinforced polyethylene sealed with a paper band which is
which is detached by traction,taking special care not to tear or puncture the
perforate the cover.
Take the first angle from the upper outer side side towards the left side edge,
gently drop it onto the table.
Repeat the same maneuver with the upper and lower left upper and lower left ends.
Check and remove the chemical indicator from the sterile the sterile package, which
guarantees the sterility of the internal sterility of the internal contents of the package
and allows us to guarantee an adequate area for the circulation and circulation and
manipulation of the medical devices to be used in the surgical procedure.
Place the pieces of the package contents at the package contents in the upper right
corner of the
right.
Proceed to regularize the edges of the package by securing the ends of the package
with hemostatic forceps, adhesive tapes or adhesive tapes or tying them by hand, on
both the left and right sides of the right side of the reserve table.
Proceed with the circulation of the medical devices necessary for the surgical
procedure, according to the according to the needs of the surgical procedure,
verifying the surgical procedure, verifying the quality control and maintaining the
proper aseptic technique