Professional Documents
Culture Documents
446.9
[17.59]
D D
[17.66]
[142.60]
448.5
[17.66]
448.5
3622.0
254 [10.0]
OUTLET SILENCER
446.9
[17.59]
1005.7
[39.59]
[34.23]
WEATHER ENCLOSURE
869.5
C C
6045.2 [238.00] 1883.0 [74.13]
1950.0 [76.77] X 863.6 [34.00] EXHAUST VENTILATION FAN
FIXED AIR INTAKE
LOUVER (STANDARD)
[4.62]
117.4
[96.65]
1930.6
[76.01]
DOORS REMOVED
[50.33]
OPENING W/
2454.9
1278.4
B B
A
1016.0 1800.0 [70.87] 707.8 899.0 [35.39] 1826.8 [71.92]
[40.00] OPENING W/DOORS REMOVED [27.87] OPENING W/ DOORS REMOVED
2039 [538] 12 HOURS STATE 381.0 [15.0] 1591 [3508] DIMENSION PRINT, 500-600KW ENCLS & TANKS
D 11-25-19 (C-5) SA11185 EXHAUST VENT FAN ADDED APPROVALS DATE
3930 [1038] 24 HOURS STATE 660.4 [26.0] 6858.0 [270.0] 1893 [4173] 500-600KW REOZVB/C [CT199135] SRB
DRAWN
RJS 6-27-11 SCALE CAD NO. SHEET
0.05 1 of 7
5757 [1520] 36 HOURS STATE 2177 [4800] STEEL/ALUM ENCL & TANKS CHECKED
RJS 6-27-11
914.4 [36.0] DWG NO.
7658 [2023] 48 HOURS STATE 8458.2 [333.0] 2680 [5908] SOUND & WEATHER APPROVED
AJD 6-27-11 ADV-8417 D
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
3266.3 [128.59]
[23.40]
446.9
594.4
[17.59]
D D
[142.60]
[17.66]
448.5
3622.0
254.0 [10.00]
OUTLET SILENCER
[28.44]
722.3
C C
117.4
[4.62]
6045.2 [238.00] 1883.0 [74.13]
[96.65]
DOORS REMOVED
[50.33]
OPENING W/
2454.8
[6.56]
1278.4
B B
A166.6
1016.0 1800.0 [70.87] 707.8 899.0 [35.39] 2172.9 [85.55]
[40.00] OPENING W/ DOORS REMOVED [27.87] OPENING W/ DOORS REMOVED
D 11-25-19 SEE SHEET 1 & 3 [CT199135] SRB APPROVALS DATE DIMENSION PRINT, 500-600KW ENCLS & TANKS
TANK INFORMATION DRAWN
RJS 6-27-11 SCALE CAD NO. SHEET
0.40 2 of 7
LITERS [GALLONS] MIN HOURS GENSETS DIM A MM [INCH] DIM B MM [INCH] TANK WEIGHT KG [LBS] (NO FUEL) CHECKED
RJS 6-27-11 DWG NO.
11554 [3052] 72 HOURS STATE 500-600KW 914.4 [36.0] 8890.0 [350.0] 4205 [9270] APPROVED
AJD 6-27-11 ADV-8417 D
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
D D
TIMER FOR
DC LIGHTS
B B
A A
REV DATE ON COMPOSITE DWGS, SEE PART NO. FOR REVISION LEVEL BY UNLESS OTHERWISE SPECIFIED -
1) DIMENSIONS ARE IN MILLIMETERS
METRIC PRO-E
- 6-27-11 NEW DRAWING [91023-12] RJS 2) TOLERANCES ARE:
X.XX POWER SYSTEMS, KOHLER, WI 53044 U.S.A.
A 3-19-12 (A-8)SEE SHEETS 5-6 [CT08748] DJV X.X THIS DRAWING IN DESIGN AND DETAIL IS KOHLER CO.
X SURFACE FINISH
B 1-10-13 SEE SHEET 1 [CT34883] SDS ANGLES
PROPERTY AND MUST NOT BE USED EXCEPT IN
MAX. CONNECTION WITH KOHLER CO. WORK. ALL RIGHTS OF
C 8-10-17 SEE SHEET 1,2,4,5,6 [CT172496] RMJ DESIGN OR INVENTION ARE RESERVED.
THIRD ANGLE TITLE
D 11-25-19 (B-5)EXHAUST VENT FAN & E-STOP ADDED[CT199135] SRB PROJECTION
STANDARD TANK
P Q R S T U
121.7
[1.59]
8 CONDUIT 4 5 7
40.5
[4.79]
ENTRY
AREA
D D
6
[13.46] TYP.
[20.96] TYP.
[68.81]
[72.00]
1747.8
1828.8
342.0
532.4
C C
B B
A
B
P Q R S T U
STATE TANK
121.7
8 CONDUIT 3 4 9 9 5 7 1
[1.59]
[4.79]
40.5
ENTRY
AREA
D D
[20.96] TYP.
[13.46] TYP.
[68.81]
[72.00]
9
1747.8
1828.8
532.4
342.0
C C
A
B B
[1.50]
ENTRY
38.0
8 3 4 9 9 5 1 7 1
AREA
D D
[13.46] TYP.
[27.73] TYP.
[82.63]
[85.63]
2098.9
2174.9
342.0
704.4
C C
[42.45] REF.
[36.00]
B B
914.4
1078.3
8890.0 [350.00] 11554 L [3052 GAL.] 72 HOUR
TANK SHOWN.
WEIGHT: 4205 [9270]
D D
C C
B 3382.0 [133.15] B
3941.0 [155.16]
4645.9 [182.91]
5045.9 [198.66]
NOTES: