You are on page 1of 2
New seneration intelligent Genset controller. When you use it you will EXPEFIENIGE the difference!!! GU621A Genset Controller Description: GU821Ais an Automatic Mains (Utility) Failure module which is designed to monitor the mains (utility ) and on failure automatically starts the generator and transfers the load, On return of the mains (utility) the controller automatically returns the load to the mains and stops the Generator after @ cool down period ‘The module also monitors and protects the engine, indicating operational status, fault conditions and metering on the front pane! LCD and LED's +128 x64 graphic LCD + True RMS measuring + Configuration of parameters by front panel push buttons or communication software + RS4B5, RS232, or USB port for remote communication + Configurable fuel output energise to stop or energise to run +7 Configurable inputs. + 5 Configurable outputs, 2 used for ATS control. + 2Analogue inputs configurable for different senders for Oil pressure and Engine temperature. + 2Aux.configurable analogue inputs + Push Buttons for manual contral of GCR/MCR Technical Parameter: Engine and Alternator Meterin: Warning and Shutdown + Mains phase voltage L1-N L2-NL3-N Alarms: + Mains line voltage L1-L2L2-L3 L3-L1 + Lowoil pressure “+ Mains frequency Hz + High engine temperature + Generator phase voltage L1-NL2-NL3-N * Over! under speed +» Generator line voltage L1-L2 L2-13L3-L1 + High’ low gen voltags + Generator current 11213 + High’ low Mains voltage + Generator frequency Hz + Start failure + Engine speed RPM + Stop failure + Generator phase apparent power kvA A1AZA3 EA + Emergency stop + Generator phase active power kw Pt P2P3 5P + Charge failure * Generator phase reactive power kvAr Qi Q2Q3 5Q + High/low battery voltage * Generator phase power factor PF PF1 PF2 PF3 + Aux. shutdown alarm * Generator total active power kwh * Aux. Warning + Generator total reactive power kvArh + Over current + Battery voltage Vde F is + Engine running hours counter h___- Optional Function (en ordering): + Engine temperature°C ("F) + Speed control for DC actuator motor + Oil pressure BAR (PSI) + Operating Temperature -40 to 70°C. + Aux, configurable analogue inputs #1 * With GPRS-DTU or Ethemet-OTU for remote * Aux. configurable analogue inputs #2 Comunication instead of Rs485, RS232, or USB ‘pot for remote communication + 41939 CAN bus communication port. Specification: DC supply: 8.0V to 35V continuous * Cranking Grop outs: OV for 100mS, assuming DC supply was at least 10V before dropout and recovers to SV + AC input voltage: phase voltage 16-300 Vac RMS (AC frequency = 40 Hz) "AC input frequency: 3-70Hz (voltage=15V) + Max oparating curront: @12V 0.44, @24V 0.2 + Max frequency input of the speed sender: 10000Hz + Voltage input of the sped sender: 1-70 Vdc + Accuracy =0.5% + Start relay output: 16A/30Vde + Fuel relay output: 16A/30Vde + Aux. control relay output: 3 A/30Vde + Protection:Controller fascia IP65 when correctly installed + Operating temperature: =20 to 70°C + Storage temperature: -30 to 80°C Harsen Product Wi 82mmxH1 44mm Wiv4mmxHiz6mm Depth D5Grm (without connection) fi ho it WOO"TWNOLLVNUSLNINSSYVH MMM ssvroonroasoscusz1A

You might also like