B37697A Revision G
easYgen-800 advanced start/stop controller comes with a large LCD, I/O expansion capability, Ether- Power metering
net and SD card connectivity
Communication ports:
ToolKit-SC is a single service tool for configuring easYgen-100 and -1000 series controllers. The module's
password-protected integral front panel lets you adjust various parameters on-site. CAN J1939, RS-485, USB
FEATURES Dedicated relays for
engine and breaker
Three-phase true RMS power sensing interface
Operation modes: AUTO, STOP, and MANUAL modes accessible through front panel, discrete inputs or via
interfaces
Switchable parameter
Remote control via multiple interfaces and discrete inputs
Direct support of several ECUs such as Bosch, Cummins, John Deere, MTU, Perkins, Scania, Volvo, Woodward sets for mobile genset
Dedicated relay outputs for cranking and fuel solenoid applications
Event and data logging capabilities with real time clock
Maintenance scheduler with multipurpose flexible timers Can be configured from
Operating hours, start, maintenance counters and monitoring computer or front panel
Three switchable parameter sets of AC system winding, Rated Voltage, Rated Frequency, Rated Current,
Rated Power, Rated Speed
Event log and event-
Can be configured from computer via USB or front panel with password protection
Manual breaker operation with tactile buttons on front panel triggered data log
Custom boot-up logo with adjustable screen display time
Multilingual customizable user interface
Released
SPECIFICATIONS
Power Supply Current Accuracy 1%
Operating Voltage 8.0 VDC to 35.0 VDC, Continuous Power Excitation current D+ 110 mA (12 V); 230 mA (24 V)
(Reverse polarity protected) Supply. (easYgen-600, easYgen-800)
Maximum supply voltage Short Time 80 V (5-10 s); Long T. 50 V Start Relay and Rated 10Adc, 24Vdc running stand-
Minimum supply voltage 6.5 V Fuel Relay Outputs alone. Rated 5Adc, 24Vdc when running
Maximum operating current (All relays closed, LCD bright) in parallel with the FUEL/GAS relay.
(easYgen-800) 450 mA (12 V); 220 mA (24 V) (easYgen-600/800 only)
Maximum standby current (All relays closed, LCD dimm) Rated 5Adc, 24Vdc when running in par-
(easYgen-800) 420 mA (12 V); 200 mA (24 V) allel with the FUEL/GAS relay.
Power Consumption <4 W (standby ≤ 2 W) (easYgen-400)
Alternator Input Range 50 Hz/60 Hz 2Adc at 24Vdc (acc. to UL 6200)
3-Phase 4-Wire AC15V - AC360V (ph-N) Housing
3-Phase 3-Wire AC30V - AC620V (ph-ph) Case Dimensions easYgen-400: 135 x 110 x 44 mm
Single-Phase 2-Wire AC15V - AC360V (ph-N) easYgen-600: 209 X 166 x 45 mm
2-Phase 3-Wire AC15V - AC360V (ph-N) easYgen-800: 237 x 172 x 45 mm
AC30V - AC300V (ph-ph) (according Panel Cutout easYgen-400: 114 x 88 mm
UL6200) easYgen-600: 186 x 141 mm
AC-Measurement Phase-phase: 100 .. 624 V:1%; easYgen-800: 214 x 160 mm
Voltage Accuracy 50 .. 100 V:1.5 % Operating Conditions Temperature: (-25 to +70) °C;
(400/480 V % rated) Phase-phase: 100 .. 300 V:1%; 50 ..100 Humidity: max. 93%, non-condensing
V:1.5 % (according to UL6200) Storage Condition Temperature: (-25 to +70) °C
Phase-neutral: 100 .. 360 V:1%
Humidity: max. 93%, non-condensing
50 .. 100 V:1.5 %
Protection Level IP65 in the front, mounted with kit
Minimum frequency Generator: 10 Hz IP20 on rear side
Maximum frequency Generator: 99.5 Hz; Net Weight easYgen-400: 0.3 kg
Frequency resolution 0.1 Hz (10 .. 99 Hz) easYgen-600: 0.56 kg
Frequency accuracy ±0.1 Hz easYgen-800: 0.85 kg
Nominal CT secondary rating 5A
Overload Measurement Max.: 10 A
APPLICATION
EG-400*/-600/-800
EG-600/-800
Ethernet DI EG-800
Load RS-485
Relay
Load Current (3ph) Outputs
Earth Current (1ph)
DI
RS232
Relay
GSM Support
easYgen-100
SD Card
Voltage (3Ph)
G D+
MPU and AI
I/O Expansion
CAN J1939
Module
30 30
*Only D+ monitoring in easYgen-400
Released
TERMINALS
easYgen-400
easYgen-600
easYgen-800
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 33 34 35
POWER SUPPLY −
+
D+
MPU−
MPU+
CAN H
CAN L
FUE L/GAS
DI02
RELAY 01
RELAY 02
DI01
A(+)
B(−)
DI07
DI05
RELAY 03
DI03
SHIE LD
DI06
SHIE LD
STARTER
NC
SHIE LD
DI04
E-STOP
RELAY 04
CAN RS485
(J1939)
USB
1 2 3 4 5 6 7 8
ETHERNET
TXD
62 63 64
RS232
DEY18d
AI01 FUE L LEVE L
GROUND
GENERATOR GENERATOR CURRENT
VOLTAGE AC CURRENT AC AC
COMMON
AI04
AI05
36 37 38 39 40 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61
Released
FEATURES OVERVIEW
CONTACT easYgen-100 Series
North & Central America Model easYgen-400 easYgen-600 easYgen-800
Tel.: +1 (208) 278 3370 Measuring
Tel.: +1 (970) 962-7272 Generator voltage (3-phase/4-wire)
SalesPGD_NAandCA@woodward.com Generator current (3x true r.m.s.)
Earth current (1x true r.m.s.) — —
South America Control
Tel.: +55 19 3708 4760 Isolated single unit operation
SalesPGD_SA@woodward.com Stand-by operation
GCB control
Europe Start/stop sequence for diesel and gas engines Diesel Diesel Diesel/Gas
Tel. Stuttgart: +49 711 78954 510 Tactile buttons to start/stop the genset and open/close the
Tel. Kempen: +49 2152 145 331 breaker
SalesPGD_EMEA@woodward.com
Protection
Middle East & Africa Generator Voltage / # of levels
/1 /2
Tel.: +971 (2) 678 4424 Frequency / # of levels
SalesPGD_EMEA@woodward.com Voltage asymmetry - -
Rotation Field - -
Russia Current
Tel.: +49 711 78954-515 Reverse Power - -
SalesPGD_EMEA@woodward.com Overload
Earth fault (measured) — —
China Engine Over speed / # of level
Tel.: +86 512 8818 5515 /1 /2
Under speed / # of level
SalesPGD_CHINA@woodward.com
Speed signal
India Crank disconnect
Tel.: +91 124 4399 500 Battery voltage
Sales_India@woodward.com HMI, Counters, and Event Log
Integral display with tactile buttons Monochrome LCD Monochrome LCD TFT LCD
ASEAN & Oceania (132 x 64) (132 x 64) (480 x 272)
Tel.: +49 711 78954 510 Customizable power-up text and image
SalesPGD_ASEAN@woodward.com Front panel configuration with PIN protection
Flush mounting
www.woodward.com Operating hours/start/maintenance counters
Subject to alterations, errors excepted. Event recorder with real time clock 50 50 99 internal; extended
data log using SD
Subject to technical modifications. card
This document is distributed for informa-
kWh, kvarh /- /- /
tional purposes only. It is not to be con- Switchable parameter sets — —
strued as creating or becoming part of I/Os and Interfaces
any Woodward Company contractual or
warranty obligation unless expressly Discrete inputs 3 (+2 switchable as AI/DI) 1x E-Stop, 5x 1x E-Stop, 8x
stated in a written sales contract. configurable configurable
Relay outputs 6 6 8
We appreciate your comments about the
Analog inputs 4x resistive (2 switchable as
content of our publications. Please send 3x resistive 5x resistive
comments including the document num- AI/DI)
ber below to Speed input (MPU) 1 1 1
stgt-doc@woodward.com Aux. excitation (D+) 1 1 1
© Woodward Ethernet (TCP/IP) — — 1
All Rights Reserved CAN (J1939) 1 1 1
USB service port 1 1 1
RS485 — 1 1
RS232 — — 1
External DI/DO via CAN bus -/- -/- 16 / 16
For more information contact:
RELATED PRODUCTS
Configuration tool ToolKit-SC (Product Specification # 37695) : P/N 9927-2684
I/O Expansion Board IKD1 (Product Specification # 37171): P/N 8440-2116
Small Engine Control Module SECM-70 (Product Specification # 36363)
B37697A – 2019/12/Stuttgart