【What’s new】
】
Shenzhen Mindray Bio-medical Electronics Co., Ltd announces that DC-70 V2.0, the
latest new version 2.0 has been officially released as of Nov. 2016.
【Product Description】
】
Mindray’s DC-70 V2.0, Color Doppler Diagnostic Ultrasound System, has been upgraded
with significant improvement for OB/GYN and SMP/Vascular, including huge jump of
3D/4D image quality, great image optimization of linear transducers, new added
transducers, new feature Smart FLC and so on.
The following shows detailed information for main improvements:
1. Image performance upgrade
1) Huge jump of 3D/4D image performance in OB/GYN
• Available on all volume transducers
• Using innovative volume rendering algorithm transplanted from Mindray
premium Resona system, including Depth VR*, to achieve huge jump of
3D/4D performance for OB/GYN applications.
a) Much better three dimensional perception
b) Much easier to acquire 3D/4D image
c) Much faster 3D/4D rendering speed and imaging processing response by
more than 40%
V1.5 V2.0
3) PW spectrum optimization for all transducers: higher spectrum density and spatial
resolution
V1.5 V2.0
new D7-2E
5. Upgrade of measurement
1) Add more measurements and calculation for ABD, OB, GYN, SMP, VAS and CAR
• ABD
a) Spleen: L, W, H, Area
b) Spleen V Diam, Spleen A Diam
c) Aorta Sten D, Aorta Sten A
d) Aorta Diam H, W
e) Aorta Aneurysm H, W, L
f) IMA, IMV
g) IVC Reflux
h) Hepatic Lesion、Hepatic Cyst
i) Renal Lesion、Renal Cyst
• Cardiac:
a) RAP (RA Pressure)
b) MPASE(Mitral Annular Plane Systolic Excursion)
c) FAC, RV FAC
3) Optimization of OB measure
• The NT figure is accurate to two decimal places, such as 2.01mm
• Allow to show EDD with GA>40 weeks
• Add “L” and “ml” for volume unit and preset “ml” as default unit for follicle vol
6. Report optimization
1) Print report with save ink option: Print setting->Ink Saving Mode
2) Report with secondary signature: Print setting->signature count
3) Optimization of OB report template: Much clearer sequence of items
7. Comment/Bodymark optimization
1) Support “Home” function to set cursor to home
2) Support short cut key of “Delete Word” function
3) “Back Space” key: Last in, first out
4) Body mark support left/right
Notice:
Since huge optimization of 3D/4D imaging algorithm in new DC-70 V2.0, software
upgrading on previous systems may result in different visualization of 3D/4D images
acquired by previous version. Slightly parameter adjustment could decrease the big
change.
Suggestion of image adjustment:
1) To solve the black hole problem: increase gain by 13
2) To solve the rough surface problem: decrease threshold from 50% to 30% or
increase smoothness from 5 to 10
【Availability】
】
The latest upgraded DC-70 V2.0 is now available in CE area.