PULSE OUTPUT (OPTTONAL):


Pulse output is provided via a magnetically actuated voltage free
reed switch contacts where the electrical instrumentation
attached provides the power to detect the opening and closing of
the reed switch.
All meters are fitted with a magnet h the last index wheel and
hence each meter is pulse retro-fittable while in service by use
an External Pulse Module without the need to interfere with the
metrology of the meter or the meter seals.
The pulse output is 1 pulse per 10 litres. No other pulse output
values are available.
Picture right shows the Model 750 Meter with Fitted with lN-261
Pulse Output Module.
The External Pulse Module can be sealed in place using the
standard lead seal, other options are available.

able 7 : Pulse Modu as


Module Number tN-261 tN-262
Part Number 750082 750083
Number of Reed one for tamper detection 1 for pulse output
Switches and one for pulse output
Wire Connections Cable and Plug 2 Screw Terminals
Part Number 32446432
Wire Coding Green-Brown = Meter Pulse Terminals = Meter Pulse
Yellow-White = Tamper Detect
Tamper Circuit A normally open tamper circuit is provided to Not Available
detect external tampering by magnetic
interference.
Voltage Switching 24Ydc 24Ydc
Umax
Current Switching 50mA 50mA
lmax
Power Maximum 0.25W 0.25W
Pmax
Contact Form SPST-NO Form A Normally Open SPST-NO Form A Normally Open

fi'
l:;:il,il

O AMPY Email Metering ' Due to continuous product development the details above are subject to change without notice.
Model 750 Gas Meter
&ffill'y lnstallation, Commissioning and Maintenance Manual

fO ORDER PULSE OUTPUT MODULE lN-261 USE P/N:750085 AND lN-262 USE P/N:750083
INSTALLATION IN STRUCTIONS :

lndividual Gomponents
I
Module
2. Lead Pin
3. -
Copper Ring Short (Long Copper Ring
supplied in kit not required)
4. Screw (15006) & BK Nut
5. -
Pulse Module Housing Bottom (262 Only)
Sealing Pin

ff
6.
7. -
Screw - Pulse Module Housing Bottom (262
Only)
8. Cable Fastener Support (262 Only)
9. Security Wire (Not lncluded)
10. Lead Seal

lN-262 - Assembly lN-Z6l & lN-262 Seeurity Sealing Pin & Wire
1. Feed pulse cable through the cable bushing 1. lnsert sealing Pin (6) into Pulse Module Housing
2. Strip the outer cable sheathing to approximately (1)
50mm - 60mm 2. Seal using wire length (9) and Lead Seal (10) if
3. Strip the inner insulation cable (length necessary desired
to attach wire end sleeves if sleeves are desired)
4. Attach the wire end sleeves or just leave wire
exposed
5. Affix the cable fastener (8) on pulse cable and
cut excess away

Fastener

lnsert Sealing Pin

lN-261 & IN-Z62lnstallation to lndex

1. Attach the pulse module to the meter index


2. lnsert Copper Ring (3) and Lead Pin (2)
3. Squash Lead Pin (2) using pliers
6. Connect the sleeves/wires to the module housing
terminals
7. Fit the Pulse Module housing bottom (5) to the
main case
8. Fit and tighten the screw (7) to the housing
bottom
\ -\
lN-261 Assembly Lead Pin

1. Push connect pulse cable into Pulse Module


Housing (1)

Notes
. Only the 261 is equipped with a Tamper Circuit
. Security wire is not supplied with either kit but will
provide better tamper securitY
. The Lead Pin (2) can be replaced by the Screw &
BK Nut (4) for securing to the index (see parts list
in table 8).
' Page !2 of 15
O AMPY Email Metering' Due to continuous product development the details above are subject to change without notice. April-2004

You might also like