You are on page 1of 1

FOUNDATION ................................................................ 24 HRS.

SUSPENDED SLAB EXCEPT WHEN


ADDITIONAL LOADS ARE IMPOSED .............................. 8 DAYS
WALLS ......................................................................... 18 HRS.
BEAMS ........................................................................ 14 DAYS
C. FOUNDATION
1. FOUNDATION IS DESIGNED FOR AN ALLOWABLE SOIL BEARING
CAPACITY 144 KPa (3000PSI)
2. FOUNDATION SHALL REST ON NATURAL SOIL. UNLESS OTHERWISE
NOTED BY THE ENGINEER, NO PART OF THE FOUNDATION SHALL
REST ON FILL.
3. THE CONTRACTOR SHALL NOTIFY THE ENGINEER AFTER FOOTING
EXCAVATION HAVE BEEN COMPLETED AND PRIOR TO CONCRETING
TO CONFIRM THE DESIGN SOIL BEARING CAPACITY.
4. IN CASE, ACTUAL SOIL BEARING CAPACITY IS FOUND TO BE LESS
THAN THE ASSUMED, NOTIFY STRUCTURAL ENGINEER FOR PROPER
REVISION OF FOOTING DESIGN. L
W(C)

DEPTH OF EMBEDMENT
VARIES

L(C)
W
1.50