You are on page 1of 1

Ultracool Inverter Specifications

Type R32 DUCTED UNIT w/ Drain pump


Indoor Unit
Model TULD50PHS1/A-S TULD71PHS1/A-S TULD100PHS1/A-S TULD140PHS1/A-S TULD160PHS1/A-S
Outdoor Unit Model TULD50W1/NhA-S TULD71W1/NhA-S TULD100W1/NhA-S TULD140W1/NhA-S TULD160W1/NhA-S
kW 5.30 7.10 10.50 14.01 16.00
Total Capacity Cooling
Kj/h 19080 25560 37800 50436 57600
EER Kj/h-W 12.2 11.9 11.5 11.0 10.5
Power supply V-Hz-Ph 220-240-50/60-1 220-240-50/60-1 220-240-50/60-1 220-240-50/60-1 220-240-50/60-1
Power input kW 1.56 2.15 3.28 4.60 5.50
Electrical Data
Rated Current A 7.5 12 16 27 30
Current Input A 7.4 (1.3-7.5) 10.2 (2.4-12) 14.3 (3.9-16) 24 (5.2-27) 25.6 (6-30)
Sound Pressure Level (H/M/L)* dB (A) 38/37/35 38/36/34 46/44/43 43/41/39 44/42/40
Refrigerant Type - R32 R32 R32 R32 R32
Air Flow Volume(rated EXP) m3/h 1100/1000/900/700 1300/1200/1100/900 1800/1600/1400/1200 2200/2000/1800/1500 2800/2500/2200/1800
Rated Pa 25 25 37 50 50
External Static Pressure
Range Pa 0-80 0-160 0-160 0-160 0-200
Fan Motor Drive Type - Direct Direct Direct Direct Direct
Drainage Connection Size mm φ26×2.5 φ26×2.5 φ26×2.5 φ26×2.5 φ26×2.5
Indoor Outline(W×D×H) mm 1000×450×200 900×655×260 900×655×260 1340×655×260 1400×700×300
Dimension Package(L×W×H) mm 1308×568×275 1115×772×320 1115×772×320 1568×770×323 1601×813×365
Weight (IDU) Net/Gross kg 23.0/28.0 29.0/33.0 30.0/34.0 43.0/49.0 53.0/60.0
Panel Outline(W×D×H) mm - - - - -
Type - Inverter Rotary Inverter Rotary Inverter Rotary Inverter Rotary Inverter Rotary
Compressor
Power Input W 857 1330 2118 3200 3200
Outdoor Outline (W×D×H) mm 675×285×553 889×340×660 889×340×660 940×370×820 940×370×820
Dimension Package (L×W×H) mm 794×376×605 1032×456×730 1032×456×730 1093×497×885 1093×497×885
Weight (ODU) Net/Gross kg 24.5/27 41.5/45.0 44.0/47.5 69.0/76.0 72.0/79.0
Gas additional charge g/m 16 16 20 35 35
Outer Liquid Pipe Inch 1/4" 3/8" 3/8" 3/8" 3/8"
Connection Diameter Gas Pipe Inch 1/2" 5/8" 5/8" 5/8" 5/8"
Pipe
Height m 15 20 20 30 30
Max Distance
Length m 30 30 30 75 75
20'GP 136 105 105 70 42
Loading
Indoor (with panel) 40'GP 288 224 224 154 84
quantity
40'HQ 288 256 256 176 98
20'GP 129 81 81 44 44
Loading
Outdoor Unit 40'GP 273 171 171 96 96
quantity
40'HQ 364 171 171 144 144
Note:
1. The cooling capacity stated above is measured under following conditions :
Indoor Condition: 27℃(81℉)DB/19℃(66.6℉)WB; Outdoor Condition: 35℃(95.4℉)DB/24℃(75.6℉)WB.
2. Noise is tested in the semi-anechoic room, so it should be slightly higher in the actual Operation due to environmental change.