Product Data
Our wide variety of input, output, and combination modules makes the
SLC 500t family the smart choice for all of your small PLC applications.
I/O modules are available in a wide variety of densities including 4-, 8-, 16-,
and 32-point and can interface to AC, DC, and TTL voltage levels. Output
modules are available with solid state AC, solid state DC, and relay contact
type outputs. For added flexibility, combination modules are also available
in 2-input/2-output, 4-input/4-output, and 6-input/6-output versions.
Designed and tested for industrial applications, our modules are of the highest
quality. The modules feature input filtering, optical isolation, and built-in
surge protection to enhance the reliability of operation in noisy industrial
environments.
Features and Benefits Terminal identification diagrams on each module. Terminal identification
diagrams are located on each module making terminal identification easier.
LEDs indicate the status
of each I/O point. LEDs indicate the status of each I/O point. Assisting you in troubleshooting,
LEDs illuminate when the proper signal is received at an input terminal, or
INPUT when the processor applies power to an output terminal.
High density 32Point DC I/O and fast response DC inputs are available. These
modules allow you to apply the SLC 500 processors in a broader spectrum of
control applications.
IN 0
IN 1
IN 2 All relay contacts are Silver Cadmium with Gold overlay. Gold plating resists
IN 3
oxidation and tarnishing resulting from non-use. Silver Cadmium acts as an
IN 4
IN 5 excellent conductor.
IN 6
IN 8
IN 9 allow you to have inputs and outputs in a single slot for efficient use of your
IN 10
IN 11
chassis space.
IN 12
IN 14
IN 13
Expand the I/O capacity of your fixed controller system. Two discrete I/O
IN 15 modules can be added to the fixed controller’s 2-slot expansion chassis
AC COM increasing the flexibility of the system.
AC COM
Terminal identification
diagrams on each module
2
Product Data
Selflocking tabs
secure the module in
the chassis.
Selflifting fieldwire
pressure plates help reduce Barrier type terminal
installation time. blocks are provided
on all modules.
Digital and field circuits are isolated. All modules feature isolation between
digital and field circuits resulting in increased noise immunity, and limited
damage to your system due to an electrical malfunction of the field wiring.
Removable terminal blocks help ease the wiring task. Removable terminal
blocks allow you to replace the module without rewiring it (not available on
all modules).
Barrier type terminal blocks provided on all modules. Each terminal block
features a barrier on three sides of each terminal to help prevent accidental
shorting of field wiring.
Selflocking tabs secure the module in the chassis. No tools are necessary to
install or remove a module from the chassis. To install a module, you slide it
into the chassis until it latches in place.
3
Product Data
Input Modules
An input module responds to an input signal in the following manner:
Input Optical
Input Filtering Isolation Logic Circuits Backplane
LED
Output Modules
An output module controls the output signal in the following manner:
Logic Optical
Backplane Circuits Output Drivers Output
Isolation
LED
4
Product Data
Surge Suppression
Most output modules have built-in surge suppression to reduce the effects of
high voltage transients. However, we recommend that you use an additional
suppression device if an output module is being used to control an inductive
device such as:
• relays • motor starters
• solenoids • motors
Additional suppression is especially important if your inductive device is in
series with or parallel to a hard contact such as:
• pushbuttons • selector switches
By adding a suppression device directly across the coil of an inductive
device, you will reduce the effects of voltage transients caused by
interrupting the current to that inductive device and prolong the life of the
switch contacts. The diagram below shows an output module with a
suppression device.
+ DC or L1
VAC/VDC
Snubber
OUT 0
OUT 1
OUT 2
AC or DC OUT 3
Output Module
OUT 4
OUT 5
OUT 6
OUT 7
COM DC COM or L2
Important: Adding a suppression device across your load will defeat the
fast turn-off feature of the 1746-OBP16 and -OVP16 DC output
modules. Refer to pages 28 and 31 for more information about
suppression when using the 1746-OBP16 and -OVP16,
respectively.
5
Product Data
The 32-point modules come equipped with a 40-pin male connector on the
front instead of screw terminals. This connector is designed to accept your
cable fitted with the 1746-N3 mating connector. One 1746-N3 connector and
45 crimp type contacts are packaged with each module. The other end of the
cable can be wired to a user-supplied terminal block.
1492CABLExx
32Point I/O Module
ÎÎÎ
Connects 32point module to DIN
ÎÎÎ
ÎÎ
rail mountable terminal block
6
Product Data
Both sinking and sourcing versions of the fast response input module are
available.
Innovative heat sink design for the OAP12 allows heat to be dissipated
through the chassis frame metal providing cool operation and excellent
reliability.
7
Product Data
OUTPUT
Blown Fuse LED
0 4 8 12
SERIAL NO.
CAT
1 5 9 13 F
F1
U
2 6 10 14
OUTPUT MODULE
SLC 500
S
3 7 11 15 E
1 AMP TRIAC
FAC
JP 1
OBP16 Replaceable 3
2
Fuse (F1)
SER
1
UL
Jumper for CPU
SA
Î
---
&
6.4 AMP/MODULE
OUTPUT RATINGS
WHEN FUSE OPENS
2 1 <---- CPU CONTINUES
3
FUSE REPLACEMENT
2
LITTLEFUSE 322010
1
A-B CAT. NO. 1746-F8
CPU FAULTS
CPU CONTINUES
MADE IN U.S.A.
F1
OVP16 Replaceable
Fuse (F1)
OUTPUT
Blown Fuse LED
0 4 8
SERIAL NO.
CAT
1 5 9 F
U
2 6 10
OUTPUT MODULE
SLC 500
S
3 7 11 E
1 AMP TRIAC
FAC
F1
SER
ÎÎ
50/60 HZ
85-265 VAC
OUTPUT VOLTAGE
Replacement Information:
ÎÎ
JP 1
Notification
OUTPUT RATINGS
FUSE REPLACEMENT
A-B CAT. NO. 1746-F9
FUSE REPLACEMENT
SAN-O HQ 6.3A
1
CPU CONTINUES
MADE IN U.S.A.
8
Product Data
9
Product Data
Solenoid Output
10
Product Data
Wiring Diagrams
The 16-point I/O module wiring diagrams include both decimal and octal
numbers for I/O addressing and wire identification. (See figure below.) The
decimal numbers in the upper left portion of each box are used to wire your
16-point I/O module to an SLC system. The octal numbers in the lower right
portion of the box are used for a PLCR system. (As shipped from the
factory, the I/O module has a decimal address label on the inside of its door.)
An octal label kit is included with your 16-point I/O modules or you can
order a separate octal conversion kit to allow you to convert your module to
the octal system.
Important: PLC systems use the octal labels. (See illustration below.)
1746IA16
100/120V ac
L1
IN 0
0 IN 1
IN 2 1
2 IN 3
IN 4 3
4 IN 5
IN 6 5
100/120V ac 6 IN 7
IN 8 7
10 IN 9
IN 10 11
12 IN 11
IN 12 13
14 IN 13
IN 14 15
16 IN 15
17
L2 AC COM
COMMONS AC COM
CONNECTED
INTERNALLY
SLC
PLC
IN 14
16
11
Product Data
+ 0V ac
ÉÉÉÉÉÉÉÉÉÉÉÉ
30V ac 85V ac 132V ac
ÉÉÉÉÉÉÉÉÉÉÉÉ
IN
Offstate Input State Not Guaranteed Onstate
-
COM (Measure voltage from common terminal to input terminal.)
NOT L1 IN 0
USED IN 0 IN 1
0
NOT IN 2 1
USED IN 1
2 IN 3
NOT IN 4 3
USED IN 2 IN 5
4
NOT IN 6 5
USED IN 3 100/120V ac IN 7
6
100/120V ac 7
L1 IN 4 IN 8
IN 0
10 IN 9
IN 10 11
IN 1 IN 5
12 IN 11
100/120V ac IN 12 13
IN 2 IN 6
14 IN 13
IN 14 15
IN 3 IN 7
16 IN 15
17
AC COM L2 AC COM L2 AC COM
L2
AC COM
COMMONS
CONNECTED AC COM COMMONS
INTERNALLY CONNECTED
INTERNALLY SLC
PLC
270 1870
AC
COM
1µF 261
1M
0.3µF
IN
270 1870
1µF 261
1M
0.3µF
IN
13
Product Data IM4
IM8
Discrete Input and Output Modules IM16
Inrush
➁ Inrush
➁
➀ Backplane Signal OffState Nominal
Voltage Operating Number Points per Catalog Current Draw Delay Current Input Current Current Time
Category Voltage of Inputs Common Number 5V 24V (max.) (max.) Current (max.) Duration (max.)
on = 35 ms 12 mA at
4 4 1746IM4 0.035A 0.0A 2 mA 1.6A 500 msec
off = 45 ms 240V ac
on = 35 ms 12 mA at
200/240V ac 170 to 265V ac 8 8 1746IM8 0.050A 0.0A 2 mA 1.6A 500 msec
off = 45 ms 240V ac
1746IM16 on = 35 ms 12 mA at
16 16 0.085A 0.0A 2 mA 1.6A 500 msec
(RTB) off = 45 ms 240V ac
➀ Frequency = 47 to 63 Hz
➁ An ac input device must be compatible with SLC 500 input circuit inrush current.
A current limiting resistor can be used to limit inrush current; however, the operating characteristics of the ac input circuit will be affected.
RTB = Removable Terminal Block.
+ 0V ac
ÉÉÉÉÉÉÉÉÉÉÉÉ
50V ac 170V ac 265V ac
ÉÉÉÉÉÉÉÉÉÉÉÉ
IN
Offstate Input State Not Guaranteed Onstate
-
COM (Measure voltage from common terminal to input terminal.)
1746IM8 1746IM16
1746IM4 200/240V ac
200/240V ac 200/240V ac
L1
NOT L1 IN 0
USED IN 0 0 IN 1
1
NOT IN 2
USED IN 1 2 IN 3
IN 4 3
NOT
USED IN 2 4 IN 5
IN 6 5
NOT
USED IN 3 200/240V ac 6 IN 7
200/240V ac 7
L1 IN 0 IN 8
IN 4 10 IN 9
IN 10 11
IN 1
IN 5 12 IN 11
200/240V ac 13
IN 2 IN 12
IN 6 14 IN 13
IN 14 15
IN 3
IN 7 16 IN 15
17
L2 AC COM L2 AC COM L2 AC COM
AC COM
COMMONS COMMONS
CONNECTED AC COM CONNECTED
INTERNALLY INTERNALLY
SLC
PLC
270 1870
AC
COM
1µF 261
1M
0.15µF
IN
270 1870
1µF 261
1M
0.15µF
IN
14
Product Data OA8
OA16
Discrete Input and Output Modules
Surge
➃
Continuous Continuous OnState
➀ Number Points ➁ Backplane Signal OffState Load Current per Current per Voltage Current
Voltage of per Catalog Current Draw Delay Leakage Current Point Module Drop per point
Category Outputs Common Number 5V 24V (max.) (max.) (min.) (max.) (max.) (max.) (max.)
120240V ac on = 1 ms ➂ 1A at 30°C 8A at 30°C 1.50V at 10.0A for
8 4 1746OA8 0.185A 0.0A 2 mA 10 mA
(Operating off =11 ms 0.50A at 60°C 4A at 60°C 1A 25 ms
V l
Voltage 1746OA16 on = 1 ms ➂ 0.50A at 30°C 8A at 30°C 1.50V at 10.0A
85265V ac) 16 8 0.370A 0.0A 2 mA 10 mA
(RTB) off = 11 ms 0.25A at 60°C 4A at 60°C 0.50A for 25 ms
➀ Frequency = 47 to 63 Hz
➁ Triac outputs turn on at any point in the ac line cycle and turn off at ac line zero cross. Recommended surge suppression for triac outputs when switching 120V ac inductive
loads is Harris MOV part number V220MA2A.
➂ To limit the effects of leakage current through solid state outputs, a loading resistor can be connected in parallel with your load. For typical 120V ac applications, use a
15k ohm, 2W resistor. For typical 240V ac applications, use a 15k ohm, 5W resistor.
➃ Repeatability is once every 1 second at 30°C. Repeatability is once every 2 seconds at 60°C.
RTB = Removable Terminal Block.
ÉÉÉÉÉÉÉÉÉ
0V ac 85V ac 265V ac
Important: If you measure the voltage at an output terminal that is not connected to a load or is connected to a highimpedance
load, you may measure as much as 100V ac even though the output is off.
15
Product Data OAP12
Surge
➃
Continuous Continuous OnState
➀ Number Points ➁➄ Backplane Signal OffState Load Current per Current per Voltage Current
Voltage of per Catalog Current Draw Delay Leakage Current Point Module Drop per point
Category Outputs Common Number 5V 24V (max.) (max.) (min.) (max.) (max.) (max.) (max.)
120-240V ac
2.0A at 30°C ➅
(Operating 1746OAP12 on = 1 ms ➂ 9.0A at 30°C 1.2V at 17.0A
12 6 0.370A 0.0A 2 mA 10 mA 1.25A at 55°C
Voltage (RTB) off = 11 ms 6.0A at 60°C 2.0A for 25 ms
85-265V ac) 1.0A at 60°C
➀ Frequency = 47 to 63 Hz
➁ Triac outputs turn on at any point in the ac line cycle and turn off at ac line zero cross. Recommended surge suppression for triac outputs when switching 120V ac inductive
loads is Harris MOV part number V220MA2A.
➂ To limit the effects of leakage current through triac outputs, a loading resistor can be connected in parallel with your load. For typical 120V ac applications, use a 15k ohm,
2W resistor. For typical 240V ac applications, use a 15k ohm, 5W resistor.
➃ Repeatability is once every 1 second at 30°C. Repeatability is once every 2 seconds at 60°C.
➄ A fused common and blown fuse LED are provided on this module. (Fuses are designed to protect the module.)
For replacement fuse, use catalog number 1746F9 or SANO HQ 6.3A.
➅ Surge current = 35A per common for 10 ms.
RTB = Removable Terminal Block.
ÉÉÉÉÉÉÉÉÉ
0V ac 85V ac 265V ac
Important: If you measure the voltage at an output terminal that is not connected to a load or is connected to a highimpedance
load, you may measure as much as 100V ac even though the output is off.
1746OAP12
100-240V ac HIGH CURRENT TRIAC OUTPUT
COMMONS
L1 VAC 1 CONNECTED
INTERNALLY
OUT 1 VAC 1 VAC
1
OUT 0
CR OUT 3 0
3 OUT 2
100-240V ac OUT 5 2
CR 5 OUT 4
NOT 4 CR
USED
NOT
USED
OUT
L2
L2
OUT 7
7 OUT 6
OUT 9 6
CR 11 OUT 8 100-240V ac
OUT 11 10
CR 13 OUT 10
12 CR
VAC 2
VAC 2
L1 OUT
SLC
PLC COMMONS
CONNECTED
INTERNALLY
16
Product Data IB8, IB16
ITB16
Discrete Input and Output Modules IC16, IH16
➀ Typical signal delay for these modules: ON=0.100 ms, OFF=0.25 ms at 24V dc.
➁ If the input module is connected in parallel with an inductive load, use surge suppression across the load to protect the input module from damage caused by
reverse voltage.
RTB = Removable Terminal Block.
ÉÉÉÉÉ
(See table for max. number of points allowed ON simultaneously.)
(Measure voltage
-
ÉÉÉÉÉ
from common terminal COM Offstate Onstate
to input terminal.)
Input State Not
Guaranteed
17
Product Data IB32
DC COM
2.8K 3K
IN IN
DC COM DC COM
-
COM
Offstate
ÉÉÉÉÉÉÉ
Input State Not Guaranteed Onstate
18
Product Data IB32
0.1µF 750
2.2K 2.2K
IN
0.1µF 750
COM
1746IB32
24V dc SINKING
Wire Wire
Group 1 Group 3
DC Com1 DC Com3
COM 1 COM 3
CONNECTED CONNECTED
INTERNALLY INTERNALLY
COM 1 COM 3
COM 2 COM 4
COMMONS COMMONS
CONNECTED CONNECTED
INTERNALLY COM 2 COM 4 INTERNALLY
DC Com2 DC Com4
Wire Wire SLC
Group 2 Group 4 PLC
Important: Each group has a separate DC common (COM). Common terminals for each wiring group are isolated from one another.
You must use the common terminal associated with the respective wiring group.
The 1746 32point modules include a keyed 40pin female connector and crimptype pins for connection to I/O wiring.
In addition, 1492 prewired cables and interface modules can be used for connecting external I/O. (See pages 6 and 46.)
19
Product Data IV8
IV16
Discrete Input and Output Modules ITV16
➀ Typical signal delay for these modules: ON=0.100 ms, OFF=0.25 ms for 24V dc.
RTB = Removable Terminal Block.
ÉÉÉÉÉ
VDC
0V dc 5V dc 10V dc 30V dc
-
IN
Offstate
ÉÉÉÉÉ Input State Not
Onstate
Guaranteed
Wiring Diagrams
1746IV8 1746IV16, ITV16
24V dc SOURCING 24V dc SOURCING
-DC
IN 0
-DC IN 0 IN 1
0
1
IN 1 IN 2
2 IN 3
IN 4 3
IN 2 4 IN 5
5
IN 6
IN 3 24V dc 6 IN 7
24V dc 7
IN 4 IN 8
10 IN 9
IN 10 11
IN 5 12 IN 11
IN 12 13
IN 6
14 IN 13
IN 14 15
IN 7
16 IN 15
17
+DC VDC +DC VDC
VDC VDC
CONNECTED VDC VDC
INTERNALLY CONNECTED
INTERNALLY SLC
PLC
20
Product Data IV8
IV16
Discrete Input and Output Modules ITV16
0 1
2 3
4
Connector Pin Function 5
6
7
A XSG0 LSB 8➀ 9➀
B XSG1
10 11
C XSG2
D
OUTPUTS
XSG3 12 13
E XSG4 14 15
F XSG5 VDC VDC
G XSG6
H XSG7 1746ITV16
J XSG8 MSB
Catalog Number
845DNXC79142
Absolute Gray Code L MSB9
Encoder
0-359 (excess 76) U Not Used
External
Open Collector Output, V 24V dc Filtered +VDC
24V dc Power
T B+ Return, Signal Common -DC COM Supply
S Not Used
Circuit Diagrams
21
Product Data IV32
ÉÉÉÉÉÉÉÉ
0V dc 5V dc 15V dc V dc
-
ÉÉÉÉÉÉÉÉ
IN Offstate Input State Not Guaranteed Onstate
Circuit Diagram
VDC
0.1µF 750
2.2K 2.2K
IN
0.1µF 750
2.2K 2.2K
IN
22
Product Data IV32
Wiring Diagram
1746IV32
24V dc SOURCING
Wire Wire
Group 1 Group 3
+VDC 1 +VDC 3
VDC 1 VDC 3
CONNECTED CONNECTED
INTERNALLY INTERNALLY
VDC 1 VDC 3
IN0 IN16
DC Com1 0 DC Com3
0
IN1 IN17
1 1
IN2 IN18
2 2
IN3 IN19
3 3
IN4 IN20
4 4
IN5 IN21
5 5
IN6 IN22
6 6
IN7 IN23
7 7
Connector Key
IN8 IN24
10 10
IN9 IN25
11 11
IN10 IN26
12 12
IN11 IN27
13 13
IN12 IN28
14 14
IN13 IN29
15 15
IN14 IN30
16 16
IN15 IN31
DC Com2 DC Com4
17 17
VDC 2 VDC 4
COMMONS COMMONS
CONNECTED CONNECTED
INTERNALLY VDC 2 VDC 4 INTERNALLY
+VDC 2 +VDC 4
SLC
Wire Wire
Group 2 Group 4 PLC
Important: Each group has a separate VDC and DC Common (COM). VDC
terminals for each wiring group are isolated from one another. You
must use the VDC terminal associated with the respective wiring
group.
23
Product Data IG16
➀ TTL inputs are inverted (-0.2 to +0.8 = low voltage = True = ON). Use a NOT instruction in your program to convert to traditional True = High logic.
➁ User supplied voltage: 4.5 to 5.5V dc, 50 mV pp ripple maximum.
RTB = Removable Terminal Block.
ÉÉÉÉÉÉÉ
+ -0.2V dc 0.8V dc 2V dc 5.5V dc
IN
-
Onstate
ÉÉÉÉÉÉÉ
Input State Not Guaranteed Offstate
TTL inputs are inverted (*0.2 to +0.8 = low voltage = True = On).
COM
(Measure voltage from common terminal to input terminal.)
SLC
PLC DC COM
24
Product Data OB8
OB16
Discrete Input and Output Modules
ÉÉÉÉÉÉ
0V dc 10V dc 50V dc
(Voltage is applied between +VDC
ÉÉÉÉÉÉ Recommended Operating Range
ÉÉÉÉÉÉ
and DC common.)
Operation Not
Guaranteed
+DC VDC
VDC OUT 0
+DC 0
OUT 1
1 OUT 2
OUT 0 2
OUT 3
3 OUT 4
OUT 1 4
CR OUT 5
5 OUT 6
OUT 2 6
OUT 7
10-50V dc CR 7 OUT 8
OUT 3 CR
10-50V dc OUT 9 10
11 OUT 10
OUT 4 CR CR
OUT 11 12
13 OUT 12
OUT 5 CR CR
OUT 13 14
CR 15 OUT 14
OUT 6 16 CR
CR OUT 15
CR 17
OUT 7
CR DC COM
DC -DC
COM
-DC
SLC
PLC
VDC
OUT
OUT
DC COM
25
Product Data OB32
Continuous
➂ Surge
➀
➁ Continuous OnState
Number Points Backplane Signal OffState Load Current per Current per Voltage Current
Voltage of per Catalog Current Draw Delay Leakage Current Point Module Drop per Point
Category Outputs Common Number 5V 24V (max.) (max.) (min.) (max.) (max.) (max.) (max.)
24V dc
(Operating ➃ 0.452A 0.0A on = 0.1 ms 1.2V at 1A for
voltage
32 16 1746OB32 1 mA 1 mA 0.1A at 60°C 3.2A at 60°C
off =1 ms 0.1A 10 ms
5-50V dc)
➀ Repeatability is once every 1 second at 30°C. Repeatability is once every 2 seconds at 60°C.
➁ To limit the effects of leakage current, a loading resistor can be connected in parallel with your load. For 24V dc operation use a 5.6k ohm, 1/2W resistor.
➂ Recommended surge suppression for switching 24V dc inductive loads is a 1N4004 diode that is reverse wired across the load.
➃ The 32point output modules are fused to protect external wiring, one fuse per common. These fuses are nonreplaceable and are rated at 2.5A.
ÉÉÉÉ
ÉÉÉÉ
(Voltage is applied between +VDC and Recommended Operating Range
DC common.)
Operation Not
Guaranteed
Circuit Diagram
VDC
OUT
0.39µF
1K
OUT
0.39µF
1K
COM
26
Product Data OB32
Wiring Diagram
1746OB32
5-50V dc TRANSISTOR OUTPUT SOURCING
Wire Wire
Group 1 Group 2
+VDC 1 +VDC 2
VDC 1 VDC 2
CONNECTED CONNECTED
INTERNALLY VDC 1 VDC 2 INTERNALLY
OUT0 OUT16
CR CR
0 0
OUT1 OUT17
CR CR
1 1
OUT2 OUT18
CR CR
2 2
OUT3 OUT19
CR CR
3 3
OUT4 OUT20
4 4
OUT5 OUT21
5 5
OUT6 OUT22
6 6
OUT7 OUT23
7 7
Connector Key
OUT8 OUT24
CR CR
10 10
OUT9 OUT25
CR CR
11 11
OUT10 OUT26
CR CR
12 12
OUT11 OUT27
CR CR
13 13
OUT12 OUT28
14 14
OUT13 OUT29
15 15
OUT14 OUT30
16 16
OUT15 OUT31
17 17
COM 1 COM 2
COMMONS COMMONS
CONNECTED CONNECTED
INTERNALLY COM 1 COM 2 INTERNALLY
DC Com1 DC Com2
SLC
PLC
27
Product Data OBP8
OBP16
Discrete Input and Output Modules
Signal ➂➅
Backplane Delay Continuous Continuous OnState Surge
OffState
➁
Number Points Current Draw (max.) Load Current per Current per Voltage Current
Voltage of per Catalog (Resistive Leakage Current Point Module Drop per Point
Category Outputs Common Number 5V 24V Load) (max.) (min.) (max.) (max.) (max.) (max.)
24V dc 1746OBP8 on = 1.0 ms 8.0A at 4A for
8 4 0.135A 0.0A 1 mA 1 mA 2.0A at 60°C 1V at 2A
((Operating
p g (RTB) off = 2.0 ms 0° to 60°C 10 ms
voltage
20.4 - 1746OBP16 on = 0.1 ms 1.5A at 30°C 6.4A at 4A for
16 16 ➀➄ 0.250A 0.0A ➃ 1 mA 1 mA 1V at 1A
26.4V dc) (RTB) off = 1 ms 1.0A at 60°C 0° to 60°C 10 ms
➀ A fused common and blown fuse LED are provided on this module. For replacement fuse, use catalog number 1746F8 or Littlefuse 322010.
Refer to page 7 for additional information.
➁ To limit the effects of leakage current, a loading resistor can be connected in parallel with your load. For 24V dc operation use a 5.6k ohm, 1/2W resistor.
➂ Repeatability is once every 1 second at 30 °C. Repeatability is once every 2 seconds at 60°C.
➃ This module provides fast OFF delay for inductive loads. Comparative OFF delay times for 1746OB8/OV8 and 1746OBP16/OVP16, when switching Bulletin 100B110
(24W sealed) contactor, are: 1746OB8/OV8 OFF delay = 152 ms; 1746OBP16/OVP16 OFF delay = 47 ms.
➄ Fast off delay for inductive loads is accomplished with surge suppressors on the OBP16 module. A suppressor at the load is not needed unless another contact is connected
in series. If this is the case, a 1N4004 diode should be reverse wired across the load. This defeats the fast turnoff feature. See also footnote 4.
➅ Surge current = 32A per module for 10 ms.
RTB = Removable Terminal Block.
ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ
0V dc 20.4V dc 26.4V dc
(Voltage is applied between +VDC and
ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ
Operation Not Guaranteed
DC common.)
Recommended
Operating Range
28
Product Data OBP8
OBP16
Discrete Input and Output Modules
-DC
NC
NC
NC S
+DC VDC2
G
OUT 4 OUT Y
CR OUT 5 D
20.4-26.4 OUT 6
V dc
CR OUT 7
DC
COM2
-DC
COM
VDC
1746OBP16
20.4-26.4V dc TRANSISTOR
6.19K S
OUTPUTSOURCING
G
+DC VDC OUT
OUT 0 D
0 8.87K
OUT 1
1 OUT 2
2
OUT 3
3 OUT 4
4
CR OUT 5
5 OUT 6
6
OUT 7
CR 7 OUT 8
20.4-26.4V dc CR
OUT 9 10
11 OUT 10
CR
OUT 11 12
13 OUT 12
CR
OUT 13 14 6.19K S
CR 15 OUT 14
16 CR G
OUT 15
CR 17 D
OUT
DC COM 8.87K
-DC
SLC
PLC
FLASH
29
Product Data OV8
OV16
Discrete Input and Output Modules
ÉÉÉÉÉÉ
0V dc 10V dc 50V dc
(Voltage is applied between +VDC and
DC common.)
ÉÉÉÉÉÉ Operation Not
Guaranteed
Recommended Operating Range
30
Product Data OVP16
ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ
0V dc 20.4V dc 26.4V dc
ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ
(Voltage is applied between +VDC and
DC common.) Operation Not Guaranteed
Recommended
Operating Range
VDC
OUT 0
0
OUT 1
1
8.87K
OUT 2
2 OUT
OUT 3 D
3 OUT 4 G
CR OUT 5 4
5 OUT 6 6.19K S
OUT 7 6
20.4-26.4V dc CR 7 OUT 8 CR
OUT 9 10
11 OUT 10
CR
OUT 11 12
13 OUT 12
CR
OUT 13 14
CR 15 OUT 14
16 CR
OUT 15
CR
17
DC COM
-DC
SLC 8.87K
PLC OUT
D
G
S
6.19K
DC COM
31
Product Data OV32
Continuous
➂ Surge
➀
➁ Continuous OnState
Number Points Backplane Signal OffState Load Current per Current per Voltage Current
Voltage of per Catalog Current Draw Delay Leakage Current Point Module Drop per Point
Category Outputs Common Number 5V 24V (max.) (max.) (min.) (max.) (max.) (max.) (max.)
24V dc
(Operating ➃ 0.452A 0.0A on = 0.1 ms 1.2V at 1A for
voltage
32 16 1746OV32 1 mA 1 mA 0.1A at 60°C 3.2A at 60°C
off = 1 ms 0.1A 10 ms
5-50V dc)
➀ Repeatability is once every 1 second at 30°C. Repeatability is once every 2 seconds at 60 °C.
➁ To limit the effects of leakage current, a loading resistor can be connected in parallel with your load. For 24V dc operation use a 5.6k ohm, 1/2W resistor.
➂ Recommended surge suppression for switching 24V dc inductive loads is a 1N4004 diode that is reverse wired across the load.
➃ The 32point output modules are fused to protect external wiring, one fuse per common. These fuses are nonreplaceable and are rated at 2.5A.
Circuit Diagram
VDC
OUT
0.39µF
1K
OUT
COM
0.39µF
1K
32
Product Data OV32
Wiring Diagram
1746OV32
5-50V dc TRANSISTOR OUTPUT SINKING
Wire Wire
Group 1 Group 2
+VDC 1 +VDC 2
VDC 1 VDC 2
CONNECTED CONNECTED
INTERNALLY INTERNALLY
VDC 1 VDC 2
OUT0 OUT16
CR CR
0 0
OUT1 OUT17
CR CR
1 1
OUT2 OUT18
CR CR
2 2
OUT3 OUT19
CR CR
3 3
OUT4 OUT20
4 4
OUT5 OUT21
5 5
OUT6 OUT22
6 6
OUT7 OUT23
7 7
Connector Key
OUT8 OUT24
CR CR
10 10
OUT9 OUT25
CR CR
11 11
OUT10 OUT26
CR CR
12 12
OUT11 OUT27
CR CR
13 13
OUT12 OUT28
14 14
OUT13 OUT29
15 15
OUT14 OUT30
16 16
OUT15 OUT31
17 17
COM 1 COM 2
COMMONS COMMONS
CONNECTED CONNECTED
INTERNALLY COM 1 COM 2 INTERNALLY
DC Com1 DC Com2
SLC
PLC
33
Product Data OG16
ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ
0V dc 4.5V dc 5.5V dc
(Measure voltage from output terminal to
common terminal.)
ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ Operation Not Guaranteed Recommended Operating Range
User supplied voltage: 4.5 to 5.5 V dc, 50 mV pp ripple maximum. User supplied current: 495 mA maximum at 5 V dc.
ÉÉÉÉÉÉÉÉÉÉÉÉÉÉ
0V dc 0.4V dc 4.5V dc 5.5V dc
OUT
-
COM
Onstate
ÉÉÉÉÉÉÉÉÉÉÉÉÉÉ Operation Not Guaranteed
+5DC
1746OG16
TTL OUTPUT (Low = True)
74AC14
+DC
VDC OUT
OUT 0 L
0
L OUT 1
1 OUT 2 L
2
L OUT 3
3 OUT 4 L
4
L OUT 5
5 OUT 6 L
OUT 7 6
+5V dc L
7 OUT 8 L
10
L OUT 9
11 OUT 10
L
12
L OUT 11
13 OUT 12
14
L 74AC14
L OUT 13
15 OUT 14
16 L
OUT 15
L 17
OUT
DC COM
-DC
SLC
PLC
DC COM
34
Product Data IN16
➀ AC frequency = 47 to 63 Hz
RTB = Removable Terminal Block.
ÉÉÉÉÉÉ
0V ac 3V ac 10V ac 30V ac
0V dc 3V dc 10V dc 30V dc
ÉÉÉÉÉÉ
+
IN
ÉÉÉÉÉÉ
Off Onstate
L1 or
+DC AC/DC COM
IN 0
0 IN 1
1
IN 2 1µF 261
2 IN 3
IN 4 3 270 1870
4 IN 5 IN
5
V ac/dc IN 6
6 IN 7
IN 8 7
10 IN 9
IN 10 11
12 IN 11
IN 12 13
14 IN 13
IN 14 15 1µF 261
L2 or 16 IN 15
-DC AC/DC 17 270 1870
COM AC/DC IN
COMMONS COM
CONNECTED
INTERNALLY
SLC
PLC
35
Product Data OW4
OW8
Discrete Input and Output Modules OW16
➀ AC frequency = 47 to 63 Hz
Amperes
➀ Amperes
➂
Maximum Voltamperes
Volts
Make Break Continuous Make Break
Relay Contact 240V ac 7.5A 0.75A
Ratings for 120V ac 15A 1.5A
OW4, OW8, and 2.5A 1800 VA 180 VA
OW16 ➁
125V dc O.22A 1.0A 28 VA
➁
1.2A
24V dc 2.0A 28 VA
➀ Connecting surge suppressors across your external load will extend the life of SLC 500 relay contacts. For recommended surge suppressors when switching ac
inductive loads, consult the SLC 500 Modular Hardware Style Installation and Operation User Manual (Publication 17476.2) or the SLC 500 Fixed Hardware
Style Installation and Operation User Manual (Publication 17476.21). Recommended surge suppression for switching 24V dc inductive loads is a 1N4004
diode reverse wired across the load.
➁ For dc voltage applications, the make/break ampere rating for relay contacts can be determined by dividing the 28 VA by the applied dc voltage.
For example, 28 VA/48V dc = 0.58A. For DC voltage applications less than 14V, the make/break ratings for relay contacts cannot exceed 2A.
➂ The continuous current per module must be limited so the module power does not exceed 1440 VA.
RTB = Removable Terminal Block.
ÉÉ
(For ac operation: voltage is applied 0 V 5V ac 265V ac
between L1 and L2.) 0 V 5V dc 125V dc
Circuit Diagram
VAC/VDC
OUT
OUT
36
Product Data OW4
OW8
Discrete Input and Output Modules OW16
Wiring Diagrams
1746OW4 1746OW8
RELAY OUTPUT 1746OW16
RELAY OUTPUT RELAY OUTPUT
L1 or
+DC VAC-VDC
. L1 or 1 OUT0
VAC-VDC L1 or
+DC VAC-VDC
+DC OUT 1 0
1 1 OUT 2
OUT 0 OUT 3 2
OUT 0 V ac/dc
V ac/dc 3 OUT 4 CR
V ac/dc
OUT 1 OUT 5 4
OUT 1
CR 5 OUT 6
CR 6 CR
OUT 2 CR OUT 7
OUT 2
L2 or CR 7
CR L2 or L2 or
OUT 3 -DC OUT 3 CR -DC -DC
NOT L1 or
VAC VDC L1 or VAC-VDC +DC
USED +DC 2
2 OUT 9
NOT 11 OUT 8
USED OUT 4 10
OUT 11
NOT V ac/dc OUT 10
USED 13 V ac/dc
OUT 5 OUT 13 12
NOT CR
15 OUT 12 CR
USED OUT 6 CR
OUT 15 14
OUT
NOT7 CR
L2 or 17 OUT 14
USED OUT 7 CR
CR -DC SLC
16
L2 or
PLC -DC
37
Product Data OX8
Continuous
➁ Continuous
➀ Number ➁ Backplane OffState Minimum Current per
Voltage of Catalog Current Draw Leakage Load Current Current per
Points per Signal Delay Module
Category Outputs Common Number 5V 24V (max.) (max.) at 5V dc Point (max.) (max.)
ac/dc Relay Refer to the
(Operating Voltage: individually 1746OX8 on = 10 ms Relay Contact ➂
8 0.085A 0.090A 0 mA 10 mA
5-265V ac isolated (RTB) off = 10 ms Ratings table
5-125V dc) shown below.
Amperes Voltamperes
Maximum Amperes
Volts Make Break Continuous
➂ Make Break
Relay
R l 240V ac 15A 1.5A
Contact 120V ac 30A 3.0A 5.0A 3600 VA 360 VA
Ratings
for OX8
O ➃
125V dc 0.22A 1.0A 28 VA
1.2A
➃
24V dc 2.0A 28 VA
➀ AC frequency = 47 to 63 Hz
➁ Connecting surge suppressors across your external load will extend the life of SLC 500 relay contacts. For recommended surge suppressors when switching ac inductive
loads, consult the SLC 500 Modular Hardware Style Installation and Operation User Manual (Publication 17476.2) or the SLC 500 Fixed Hardware Style Installation and
Operation User Manual (Publication 17476.21). Recommended surge suppression for switching 24V dc inductive loads is a 1N4004 diode reverse wired across the load.
➂ The continuous current per module must be limited so the module power does not exceed 1440 VA.
➃ For dc voltage applications, the make/break ampere rating for relay contacts can be determined by dividing the 28 VA by the applied dc voltage.
For example, 28 VA/48V dc = 0.58A. For DC voltage applications less than 14V, the make/break ratings for relay contacts cannot exceed 2A.
RTB = Removable Terminal Block.
ÉÉ
0 V 5V ac 265V ac
(For ac operation: voltage is applied
0 V 5V dc 125V dc
between L1 and L2.)
(For dc operation: voltage is applied
ÉÉ
ÉÉ
Recommended Operating Range
between +VDC and DC common.)
Operation Not
Guaranteed
1746OX8
ISOLATED RELAY OUTPUT
VAC/VDC
VAC-VDC
VS0 L1 0
OUT 0 CR VS0 L2
VS1 L1 VAC-VDC
1
OUT 1 VS1 L2
VAC-VDC OUT
VS2 VDC
2
OUT 2 VS2 DC COM
VAC-VDC
VS3 VDC 3
OUT 3 CR VS3 DC COM
NOT USED
VDC/VAC
NOT
USED
VAC-VDC
VS4 L1 4
OUT 4 CR VS4 L2
VAC-VDC
VS5 L1 5
OUT 5 VS5 L2 OUT
VS6 VDC VAC-VDC
6
OUT 6 VS6 DC COM
VAC-VDC
VS7 VDC 7
OUT 7 CR VS7 DC COM
38
Product Data IO4
IO8
Discrete Input and Output Modules IO12
➀ Frequency = 47 to 63 Hz
+ 0V ac
ÉÉÉÉÉÉÉÉÉÉÉÉ
30V ac 85V ac 132V ac
-
IN
Offstate
ÉÉÉÉÉÉÉÉÉÉÉÉ Input State Not Guaranteed Onstate
COM
(Measure voltage from common terminal to input terminal.)
ÉÉ
0 V 5V ac 265V ac
(For ac operation: voltage is applied
between L1 and L2.) 0 V 5V dc 125V dc
Circuit Diagram
270 1870
VAC/VDC
AC COM
1µF 261
1M
OUT
0.3µF
IN
270 1870
OUT
1µF 261
1M
0.3µF
IN
39
Product Data IO4
IO8
Discrete Input and Output Modules IO12
Wiring Diagrams
1746IO4
100/120V AC INPUT RELAY OUTPUT
1746IO8
100/120V AC INPUT RELAY OUTPUT
L1 or
VAC-VDC +DC L1 or
VAC-VDC +DC
OUT 0 V ac/dc
OUT 0
OUT 1 L2 or
CR V ac/dc
-DC
OUT 1
NOT
USED CR
OUT 2
NOT
USED CR L2 or
OUT 3
L1 -DC
IN 0
L1 IN 0
IN 1
IN 1
100/120 NOT
V ac USED 100/120
V ac IN 2
NOT
USED
IN 3
OUT 7
L2 AC COM OUT 7
L2 AC COM
1746IO12
100/120V AC INPUT RELAY OUTPUT
L1 or
+DC VAC-VDC
OUT 0
OUT 1
OUT 2
V ac OUT 3
OUT 4 CR
CR OUT 5
NOT
L2 or USED
-DC
L1
NOT
USED
IN 0
IN 1
IN 2
100/120 IN 3
V ac IN 4
IN 5
NOT
NOT USED
USED AC COM
L2
40
Product Data
Fixed I/O Chassis You can use either of two methods to determine whether the 2-slot, fixed I/O
Module Compatibility expansion chassis will support a specific combination of modules.
• tabular method
• charting method
The table on the following page represents combinations of modules and
indicates whether or not each combination is valid. The chart on page 43
represents the region of operating current that the fixed I/O expansion chassis
supports.
Tabular Method
Using the table on the next page, locate both of the modules you plan to use
in the fixed I/O expansion chassis. Follow the top row across until you find
one of the modules. Then follow the left column down until you find the
other module. The symbol shown in the table cell that marks their
intersection gives you information you must know before installing the
modules.
• A dot indicates a valid combination.
41
Product Data
42
Product Data
5V dc 24V dc
AMPS AMPS Charting Method
IA4 0.035 -
The following chart depicts the range of current combinations supported by
IA8 0.050 -
the fixed I/O expansion chassis. To use it, you must first determine the
IA16 0.085 -
backplane current draw and operating voltage for both of the modules you
IM4 0.035 -
plan to use in the chassis. You can get these specifications from the table
IM8 0.050 -
alongside the chart. Next, plot each of the currents on the chart below. If the
IM16 0.085 -
OA8 0.185 -
point of intersection falls within the operating region, your combination is
OA16 0.370 -
valid. If not, your combination cannot be used in a 2-slot, fixed I/O chassis.
OAP12 0.370 -
IB8 0.050 -
IB16 0.085 -
450 OA16 and IA16
IV8 0.050 - (0, 455)
IV16 0.085 -
IG16 0.140 - 400
OV8 0.135 -
OV16 0.270 -
350
OB8 0.135 -
OBP8 0.135 -
OG16 0.180 - 300
OW4 0.045 0.045
OW8 0.085 0.090 5V dc OW16 and IA16
Current 250
OW16 0.170 0.180 (180, 255)
(mA)
IO4 0.030 0.025 Valid Operating Region
IO8 0.060 0.045 200
IO12 0.090 0.070
NI4 0.025 0.085 150
NIO4I 0.055 0.145 x Plotted from
NIO4V 0.055 0.115
Example
100 Shown Below
FIO4I 0.055 0.150
FIO4V 0.055 0.120
DCM 0.360 - 50
HS 0.300 -
OB16 0.280 -
IN16 0.085 -
BASn 0.150 0.125
50 100 150 200
BAS 0.150 0.040
24V dc Current (mA)
OB32 0.452 -
OV32 0.452 -
IV32 0.106 -
IB32 0.106 - Example: Plot IN16 and NIO4V
OX8 0.085 0.090 IN16 = 0.085A at 5V dc
NO4I 0.055 0.195 NIO4V = 0.055A at 5V dc and 0.115A at 24V dc
NO4V 0.055 0.145
ITB16 0.085 - 1. Add current draws of both modules at 5V dc to get 0.14A (140mA).
ITV16 0.085 -
2. Plot this point on the chart above (140mA @ 5V dc).
IC16 0.085 -
IH16 0.085 - 3. Plot current draw at 24V dc (115mA @ 24V dc).
KE 0.150 0.040
KEn 0.150 0.125 4. Note the point of intersection on the chart above (marked x). This
OBP16 0.250 - combination falls within the valid operating region for your fixed I/O
OVP16 0.250 - chassis.
NT4 0.060 0.040
Important: The NO4I and NO4V analog output modules may require an
NR4 0.050 0.050
external power supply. Refer to your analog user’s manual.
HSPT1 0.200 -
43
Product Data
Environmental
Specifications Operating Temperature ➀
0°C to 60°C (32°F to 140°F)
Storage Temperature -40°C to 85°C (-40°F to 185°F)
Operating Humidity 5% to 95% (noncondensing)
Noise Immunity NEMA standard ICS 2-230
Vibration (Operating) Displacement 0.015 inch peak at 5-57 Hz.
Acceleration 2.5Gs at 57-2000 Hz
Shock (Operating) 30Gs (all modules except relay contact).
10Gs (relay contact modules, 1746OW, OX, I/O Combo).
Isolation
➁ 1500 Volts
Certification
➂➃ UL listed. CSA approved. CE compliant for all applicable
directives when product or packaging is marked.
Discrete I/O Power The table on the following page lists the power dissipation for all discrete I/O
Dissipation modules operating at nominal voltage. An explanation of the terms used in
the table follows:
Watts per point — the heat dissipation that can occur in each field wiring
point when energized at nominal voltage.
Minimum watts the amount of heat dissipation that can occur when there
is no field power present.
Total watts the watts per point plus the minimum watts (with all points
energized).
For examples on calculating system heat dissipation, refer to the SLC 500
Modular Hardware Style Installation and Operation User Manual
(Publication 1747-6.2) or the SLC 500 Fixed Hardware Style Installation and
Operation User Manual (Publication 1747-6.21).
44
Product Data
45
Product Data
Accessories The following accessories are available for use with Discrete I/O modules:
Catalog
Item Description
Number
Helps prevent debris from entering the SLC
1746N2 Modular card slot filler enclosure that can cause shorts or improper
operation.
Connects electronic wiring (discrete I/O
Feedthrough interface modules, particularly 16 and 32point) to electric
1492IFMxx
modules wiring (factory devices). Available with either 20
or 40 terminals.
Cables:
Connects directly to the 1492IFMxx interface
- 1 m. (3.3 ft.)
1492CABLExx module and is available with a removable
- 2.5 m. (8.2 ft.)
terminal block or a readytowire free end.
- 5 m. (16.4 ft.)
This kit allows you to create your own cable (3.2
meters max.) if the Catalog Number 1746C15
cable is not long enough. It contains one female
1746N3 Connector kit
connector and 45 crimp contacts.
Note: 32point modules are shipped with one
connector kit.
Support Services In today’s competitive environment, when you buy any product, you expect
that product to meet your needs. You also expect the manufacturer of that
product to back it up with the kind of customer service and product support
that will prove you made a wise purchase.
46
Product Data
Notes
47
SLC 500, SLC 5/03, and SLC 5/04 are trademarks of Allen-Bradley Company, Inc.
PLC is a registered trademark of Allen-Bradley Company, Inc.
AllenBradley, a Rockwell Automation Business, has been helping its customers improve
productivity and quality for more than 90 years. We design, manufacture and support a broad
range of automation products worldwide. They include logic processors, power and motion
control devices, operator interfaces, sensors and a variety of software. Rockwell is one of the
world's leading technology companies.
Worldwide representation.
Argentina • Australia • Austria • Bahrain • Belgium • Brazil • Bulgaria • Canada • Chile • China, PRC • Colombia • Costa Rica • Croatia • Cyprus • Czech Republic •
Denmark • Ecuador • Egypt • El Salvador • Finland • France • Germany • Greece • Guatemala • Honduras • Hong Kong • Hungary • Iceland • India • Indonesia •
Ireland • Israel • Italy • Jamaica • Japan • Jordan • Korea • Kuwait • Lebanon • Malaysia • Mexico • Netherlands • New Zealand • Norway • Pakistan • Peru •
Philippines • Poland • Portugal • Puerto Rico • Qatar • Romania • Russia-CIS • Saudi Arabia • Singapore • Slovakia • Slovenia • South Africa, Republic • Spain •
Sweden • Switzerland • Taiwan • Thailand • Turkey • United Arab Emirates • United Kingdom • United States • Uruguay • Venezuela • uY goslavia
AllenBradley Headquarters, 1201 South Second Street, Milwaukee, WI 53204 USA, Tel: (1) 414 3822000 Fax: (1) 414 3824444