Subject: Correction of Deice Operation Diagram & Wiring Diagram

Please file and use this supplement manual together with the service manual for Model No. WH-ADC0309H3E5B
Order No PAPAMY1607070CE

WARNING
This service information is designed for experienced repair technicians only and is not designed for use by the general public.
It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to service a product.
Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any attempt to service
or repair the products dealt with in this service information by anyone else could result in serious injury or death.

© Panasonic Corporation 2016


1. Protection Control For Heating Operation (WH-UD03HE5-1 WH-UD05HE5-1)

1.1 Deice Operation

When outdoor pipe temperature and outdoor air temperature is low, deice operation start where outdoor fan
motor stop.

Outdoor Unit Deice Control


10
Deice starts depends:
5 1. Outdoor air sensor temp.
2. Outdoor pipe sensor temp.
0
OD Pipe Temperature (°C)

3. Heating accumulation time.


-5

-10
When Heating Time > 35 minutes
-15 and Pipe Temperature below this
line for continuous 3 minutes.
-20

-25

-30
-30 -30 -30 -30 -30 -30 -30
Outdoor Temperature (°C)

Old Deice Diagram

Outdoor Unit Deice Control


10
Deice start depends:
5 1. Outdoor air sensor temp.
2. Outdoor pipe sensor temp.
0
OD Pipe Temperature (°C)

3. Heating accumulation time


-5

-10

When Heating Time > 35 minutes


-15
and Pipe Temperature below this
line for continuous 3 minutes
-20

-25

-30
-30 -20 -10 0 10 20 30
Outdoor Temperature (°C)

New Deice Diagram

2
RED WHITE OLP
80±3°C
BL
RCCB/ELCB
BL (L1 )
(N1 )

1 1 230V 30A~40A
REACTOR I n=30mA
2.1 Indoor Unit

R R

POWER SUPPLY 2
LEAD WIRE FIXING FOR HEATER
W W G 2 2 W

Single phase AC230V 50Hz


2 1 BL GROUNDING
Old Wiring Diagram

2 1 W
RCCB/ELCB
W W
(L) BL BL
L2 L1 G03
(WHT) (WHT) (GRN) A B TERMINAL BOARD
(N) W

(BLK)

(RED)
(WHT)

AC2-L3
AC2-N2

HT1-L3
FUSE1 FUSE 3 W
230V 30A~40A G BL T3.15A L250V
I n=30mA AC1-L3 T6.3A L250V NOISE
RECTIFICATION

POWER SUPPLY 1
(BLK) NOISE FILTER FILTER BACKUP HEATER (3kW)

RY-HT (L3)
CIRCUIT CIRCUIT CN6
WATER CONNECTING W AC1-N CIRCUIT

Single phase AC230V 50Hz


PIPING BAR (WHT) SIGNAL OLP BOOSTER
GROUNDING G DETECTION HEATER
CIRCUIT
2. Wiring Connection Diagram

TERMINAL ROOM TEMP.


BOARD WATER CONNECTING ZONE 1
PIPING BAR G01
1 G (GRN)
(BL) CN5
2 OUTDOOR AIR
(W) COMMUNICATION SW1 SW2 SENSOR
R DATA CIRCUIT
3
(R) (RED) TANK
G G02 SENSOR
(GRN)

TO OUTDOOR UNIT
ELECTRONIC CONTROLLER
NOISE CN4
RECTIFICATION
(MAIN)
GROUNDING FILTER EXTERNAL
W 7 7 W 1 CIRCUIT CIRCUIT CONTROL 1
BL 4 4 BL 4 BL
BLUE WATER M 5 WATER CONTROL
R 3 3 R
BLUE PUMP BR 2 2 BR 6 PUMP BL PANEL

3
B 1 1 B 7
BLACK CIRCUIT
CN-PUMP1
(WHT) CN3
BL 3 3 BL RY-CONTACT1
BLACK
B 2 2 B
BOILER CONTACT
M
MIXING 1~
VALVE 2 BR 1 1 BR SSR1
EXTRA PUMP
ROOM THERMO 2 ROOM THERMO 1
L N COOL HEAT L N COOL HEAT
OLP
LEAD WIRE FIXING FOR OLP 80±3°C
B
CN-OLP1 1
ACN (WHT) 2 B

RY-V2
RY-V3
CN209 CN201 CN202 CN203 (WHT) W 1
BR
1 W
POOL WATER ACL BL 3 CN-PWR CN-FLWSEN FLOW
PUMP SSR202 B
(BLK) (BLK) (WHT)
SIGNAL SIGNAL BL SENSOR
DETECTION DETECTION W 5 4
SOLAR WATER CIRCUIT CIRCUIT 1
SSR203 W CN-CNT 1
PUMP CN-COMM 3 (WHT) t˚ WATER OUTLET TEMP. SENSOR (THERMISTOR)
(YLW) W CN-TH1
t˚ REFRIGERANT TEMP. SENSOR (THERMISTOR)
W 1 SIGNAL (WHT)

SSR206
SSR207
ERROR 4 t˚
SIGNAL RY1
DETECTION 6 WATER INLET TEMP. SENSOR (THERMISTOR)
1 W 1 CN-PWR2 CIRCUIT CN-TH3 1 t˚ HEX WATER OUTLET TEMP. SENSOR

(YLW)
CN208 2 2 (BLU)
W (WHT) 2 (THERMISTOR)

CN-PWR202
WATER PUMP
ZONE 1 SSR200 W CN-TH2 1 t˚
CN-PWR204 1 2 CN-PWR4 TANK TEMP. SENSOR
ELECTRONIC CONTROLLER (WHT) 2 (THERMISTOR)
B 1 1 B (YLW) 2 3 W 1 (BLK)
(SUB)
M BR BR SSR201 DCN
1~ (BLU) B 3
2 2 CN-PWR3
1 DCP (GRN)
Y/G CN-CNT (RED) R 1
WATER PUMP (WHT) CN205 CN204 CN207 CN206 CN210
ZONE 2 BASE PAN 5
t˚ CN1 CN2

VCC BIT2 BIT1 REMARKS :


BR BL B
DC DC W : WHITE BR : BROWN
GND 10V HEAT COOL N L
CLOSE OPEN N
ROOM THERMO 1 O : ORANGE G : GREEN
2-WAY

ZONE 2
ZONE 1
SENSOR
SWITCH

SENSOR
VALVE M R : RED GR : GRAY
EXTERNAL
COMP. SW

SG SIGNAL
1~

HEAT/COOL

POOL TEMP.
SENSOR
SOLAR TEMP.

ROOM TEMP.
ROOM TEMP.
B : BLUE Y/G : YELLOW/GREEN

DEMAND
3-WAY
BL : BLACK ELCB : EARTH LEAKAGE CIRCUIT BREAKER

ZONE 2 WATER TEMP.


SENSOR (THERMISTOR)
VALVE Y : YELLOW
RED WHITE OLP
80±3°C
BL
RCCB/ELCB
BL (L1 )
(N1 )

1 1 230V 30A~40A
REACTOR I n=30mA
R R

POWER SUPPLY 2
LEAD WIRE FIXING FOR HEATER
W W G 2 2 W
Single phase AC230V 50Hz
2 1 BL GROUNDING
W
New Wiring Diagram

2 1
RCCB/ELCB
W W
(L) BL BL
L2 L1 G03
(WHT) (WHT) (GRN) A B TERMINAL BOARD
(N) W

(BLK)

(RED)
(WHT)

AC2-L3
AC2-N2

HT1-L3
FUSE1 FUSE 3 W
230V 30A~40A G BL T3.15A L250V
I n=30mA AC1-L3 T6.3A L250V NOISE
RECTIFICATION

POWER SUPPLY 1
(BLK) NOISE FILTER FILTER BACKUP HEATER (3kW)

RY-HT (L3)
CIRCUIT CIRCUIT CN6
WATER CONNECTING W AC1-N CIRCUIT

Single phase AC230V 50Hz


PIPING BAR (WHT) SIGNAL OLP BOOSTER
GROUNDING G DETECTION HEATER
CIRCUIT
TERMINAL ROOM TEMP.
BOARD WATER CONNECTING ZONE 1
PIPING BAR G01
1 G (GRN)
(BL) CN5
2 OUTDOOR AIR
(W) COMMUNICATION SW1 SW2 SENSOR
R DATA CIRCUIT
3
(R) (RED) TANK
G G02 SENSOR
(GRN)

TO OUTDOOR UNIT
ELECTRONIC CONTROLLER
NOISE CN4
RECTIFICATION
(MAIN)
GROUNDING FILTER EXTERNAL
W 7 7 W 1 CIRCUIT CIRCUIT CONTROL 1
BL 4 4 BL 4 BL
BLUE WATER M WATER CONTROL
5

4
R 3 3 R
BLUE PUMP BR 2 2 BR 6 PUMP BL PANEL
B 1 1 B 7
BLACK CIRCUIT
CN-PUMP1
(WHT) CN3
BL 3 3 BL RY-CONTACT1
BLACK
B 2 B
BOILER CONTACT
M 2
MIXING
VALVE 2 1~ BR 1 1 BR SSR1
EXTRA PUMP
ROOM THERMO 2 ROOM THERMO 1
L N COOL HEAT L N COOL HEAT
OLP
LEAD WIRE FIXING FOR OLP 80±3°C
B
CN-OLP1 1
ACN (WHT) 2 B

RY-V2
RY-V3

N
CN209 CN201 CN202 CN203 (WHT) W 3

OPEN
BR

CLOSE
1 W
POOL WATER ACL BL 1 CN-PWR CN-FLWSEN FLOW
PUMP SSR202 B
(BLK) (BLK) (WHT)
SIGNAL SIGNAL BL SENSOR
DETECTION DETECTION W 5 4
SOLAR WATER CIRCUIT CIRCUIT 1
PUMP SSR203 W CN-CNT 1
W 3 (WHT) CN-TH1 WATER OUTLET TEMP. SENSOR (THERMISTOR)

(YLW)
W 1 SIGNAL (WHT) REFRIGERANT TEMP. SENSOR (THERMISTOR)

SSR206
SSR207
ERROR 4
SIGNAL RY1
DETECTION 6 WATER INLET TEMP. SENSOR (THERMISTOR)
1 W 1 CN-PWR2 CIRCUIT CN-TH3 1 HEX WATER OUTLET TEMP. SENSOR

(YLW)
CN208 2 W 2 (BLU) (WHT) 2 (THERMISTOR)

CN-PWR202 CN-COMM
WATER PUMP
ZONE 1 SSR200 1 W 2 CN-PWR4 CN-TH2 1
ELECTRONIC CONTROLLER CN-PWR204 2 TANK TEMP. SENSOR
B 1 1 B (YLW) 3 W 1 (BLK) (WHT) 2 (THERMISTOR)
(SUB)
M BR BR SSR201 DCN
1~ (BLU) B 3
2 2 CN-PWR3
1 DCP (GRN)
Y/G CN-CNT (RED) R 1
WATER PUMP (WHT) CN205 CN204 CN207 CN206 CN210
ZONE 2 BASE PAN 5
N

CLOSE
OPEN

CN1 CN2

VCC BIT2 BIT1 REMARKS :


BR BL B
DC DC W : WHITE BR : BROWN
GND 10V HEAT COOL N L
CLOSE OPEN N
ROOM THERMO 1 O : ORANGE G : GREEN
2-WAY

ZONE 2
ZONE 1
SENSOR
SWITCH

SENSOR
VALVE M R : RED GR : GRAY
EXTERNAL
COMP. SW

SG SIGNAL
HEAT/COOL 1~

SIGNAL

POOL TEMP.
SOLAR TEMP.

ROOM TEMP.
ROOM TEMP.
B : BLUE Y/G : YELLOW/GREEN

DEMAND
3-WAY
BL : BLACK RCCB/ELCB : RESIDUAL CURRENT CIRCUIT BREAKER/

ZONE 2 WATER TEMP.


SENSOR (THERMISTOR)
VALVE Y : YELLOW EARTH LEAKAGE CIRCUIT BREAKER

You might also like