You are on page 1of 1

Actuator-Sensor-Interface (AS-Interface®) Selection

Standard Application Modules—IP 65/IP 67

Ref. A Ref. B Ref. C Ref. D

For More Information Catalog Page


Accessories 46, 115, 116
Typical Connecting Plugs 117
Specifications 32, 33, 34, 36
Connections 47
Dimensions 37

To Order: For a Complete Application Module, Select One Standard Module and the Applicable Coupling Module from the table below.

Picture Yellow Cable Yellow Cable


Reference Current Carrying M12 Male Receptacle Black Cable
Capacity Protections Standard Module AS-Interface® Module+ AS-Interface® Module+
Application Module Input Output Short
Module Type Typical (mA) (A) Circuit Overload Catalog No Price $ Catalog No Price $ Catalog No Price $
Standard 4 Input A 100 PNP — Yes Yes 3RG9001-0AA00 — — — —
User 200 PNP — Yes Yes — — 3RG9001-0AG00 — —
Module 3RK1200-0CQ01-
Without 200 NPN — Yes Yes — — — —
0AA3
Coupling
4 Output B — 1 (Relay) No No 3RG9001-0AB00 — — — —
Module
1 PNP
— Yes No — — 3RG9001-0AL00 — —
(Electronic)
A 1 PNP
— Yes No — — — — 3RG9001-0CB00
(Electronic)
1 NPN 3RK1100-1CQ01-
— Yes No — — — —
(Electronic) 0AA3

2 Input/ A 200mA PNP
Yes Yes 3RG9001-0AJ00 — — — —
1 Output for all inputs and outputs
2 Input/ B Yes
100 PNP 1 (Relay) No 3RG9001-0AC00 — — — —
2 Output (Input)
2 PNP
120 PNP Yes Yes — — 3RG9001-0AM00 — —
(Electronic)
A 2 PNP Yes
120 PNP Yes — — — — 3RG9001-0CC00
(Electronic) (Input)
2 NPN Yes 3RK1400-1BQ01-
200 NPN Yes — — — —
(Electronic) (Input) 0AA3
22 A
200 PNP — Yes Yes — — 3RG9001-0AH00 — —
Input
Coupling FK Coupling C For use with yellow control cable. 3RG9010-0AA00 — —
Module FK/VA For use with yellow control cable.
3RK1901-1HA00 — —
Coupling Stainless steel hardware, Viton seals.
FK/Address For use with yellow control cable.
3RK1901-1MA00 — —
Coupling Includes integrated address port.
FK-E Coupling For use with yellow control cable and black power cable. — — 3RG9030-0AA00
FK-E/VA For use with yellow control cable and black power cable.
— — 3RK1901-1JA00
Coupling Stainless steel hardware, Viton seals.
FK-E/
For use with yellow control cable and black power cable.
Address — — 3RK1901-1NA00
Includes integrated address port.
Coupling
Pg D
For use with yellow control cable. 3RG9220-0AA00 — —
Coupling
Pg-E
For use with yellow control cable and black power cable. — — 3RG9240-0AA00
Coupling
Yellow Cable  AS-Interface Control Power and
® Control Power, Communications and Output Power provided New SAP4 ASIC chip.
Communications; M12 Receptacle  External Power Supply by the AS-interface® Line.
for Outputs. Y-II Connection. Refer to “Connections”, page 47, for a visual
Yellow Cable  AS-Interface® Control Power and representation; “Specifications” page 34 for pin logic assign-
Communications; Black Cable  External Power Supply for ments.
Outputs.

29
Siemens & Furnas Control Products/Siemens Automation Products