Professional Documents
Culture Documents
Дополнителни работи Машинство 23.02.2023 PDF
Дополнителни работи Машинство 23.02.2023 PDF
Weishaupt –
Low NOx Solutions for
Boiler Applications
- weishaupt -
Content
• Applications
1
- weishaupt -
Manufacturing
&
Assembly
Research
&
Administration Development
“The Forum”
Training Facility
- weishaupt -
2
- weishaupt -
§ Established in 1962
§ One of the largest
privately owned
research facilities
§ 100 full time
engineers plus support
staff keeps Weishaupt
burners at the leading
edge of technology
§ Several sizes of
units to match the
capacity requirements
- weishaupt -
3
- weishaupt -
Quality
• Priority No.1
• Checks for quality
and consistency
• Latest equipment
- weishaupt -
Product Line
§ W Series
§ max 2,000 MBH
§ Monarch Series
§ max 37,000 MBH
§ WK Series
§ max 60,000 MBH
4
- weishaupt -
Content
• Applications
- weishaupt -
Content
• Applications
5
- weishaupt -
- weishaupt -
6
- weishaupt -
Incomplete Combustion
- weishaupt -
Combustion Efficiency
§ Low O2 in flue
gas means high
energy gain & high
efficiency.
7
- weishaupt -
- -weishaupt
weishaupt- -
Control linkages
Ø The control linkages on a burner
are critically important since their
function is to control the fuel to air
ratio throughout the firing capacity
of the burner.
Ø In order to maximize efficiency and
ensure repeatability, control
linkages must be well designed with
a minimum of hysteresis.
Ø Excessive “play” has a detrimental
effect on how well a burner can be
tuned and therefore directly affects
the burner and boiler efficiency. Typical Linkage Arrangement
8
-- weishaupt
weishaupt- -
Control linkages
AIR CONTROL
FUEL AIR CONTROL DAMPER
DRIVE MOTOR
COMBUSTION AIR
DAMPER DRIVEN
DIRECTLY FROM
MOTOR SHAFT
( NO HYSTERISIS)
- weishaupt -
Control linkages
BURNER OPERATES WITH LEAN MIXTURE
FUEL AIR CONTROL AIR CONTROL
DRIVE MOTOR MOVES DAMPER MOVES
5 ° TOWARD HIGHER OPEN 5 °
FIRING RATE
COMBUSTION AIR
DAMPER DRIVEN
DIRECTLY FROM
MOTOR SHAFT
( NO HYSTERISIS)
HYSTERESIS
FUEL CONTROL VALVE
REMAINS IN SAME
X° POSITION
BECAUSE OF
HYSERESIS
9
-- weishaupt
weishaupt- -
Control linkages
BURNER OPERATES WITH LEAN MIXTURE
AIR CONTROL
FUEL AIR CONTROL DAMPER MOVES
DRIVE MOTOR MOVES OPEN
ADDITIONAL 5 ° TOWARD ADDITIONAL 5 °
HIGHER FIRING RATE
COMBUSTION AIR
DAMPER DRIVEN
DIRECTLY FROM
MOTOR SHAFT
( NO HYSTERISIS)
- weishaupt -
Control linkages
BURNER OPERATES WITH RICH MIXTURE
COMBUSTION AIR
DAMPER DRIVEN
DIRECTLY FROM
MOTOR SHAFT
HYSTERESIS
( NO HYSTERISIS)
10
- weishaupt -
Control linkages
- weishaupt -
Control linkages
11
- weishaupt -
§ High temperature
stainless steel flame
tube
§ Precisely
manufactured
combustion head
components
§ Very simple service
- weishaupt -
12
- weishaupt -
• Major Benefits:
– Increased efficiency with
higher turndown ratio
- weishaupt -
Turndown Ratio
High Fire
Burner starts
4:1
13
- weishaupt -
Content
• Applications
- weishaupt -
14
- weishaupt -
Fuel Staging
- weishaupt -
Internal Recirculation
15
- weishaupt -
Combined Technologies
- weishaupt -
16
- weishaupt -
multiflam®
- weishaupt -
multiflam®
Primary Nozzle
Secondary Nozzle 1
Secondary Nozzle 2
Primary Air
Secondary Air
Secondary Nozzle 3
17
- weishaupt -
multiflam® Gas
120
50
in ppm
100
[mg/kWh]
80
Emissions
30 ppm
NOx-Emisssion
60
25
40
NOx
NaturalErdgas
Brennstoff Gas E, LL
20
Meßwerte korrigiert nach EN 676
0
0 0 2000
7,000 4000
14,000 6000
21,000 8000
28,000 10000
35,000 12000
42,000
Brennerleistung [kW]
Capacity in MBH
- weishaupt -
multiflam® Oil
75
150 75 ppm
NOx-Emission [mg/kWh]
NOx Emissions in ppm
100
50
25
50
Brennstoff
Fuel #2 OilHeizöl EL
0
0 0 7,000 14,000 21,000 28,000 35,000 42,000
2000 4000 6000 8000 10000 12000
Capacity in MMBH
Brennerleistung [kW]
18
- weishaupt -
125
O
100
ppm)
75
N
50
25
0 25 50 75 100
Burner Copacity
- weishaupt -
L 3 LN 125-400 kW
L 5 LN 125-480 kW
RL 7 / 1 LN 225-1000 kW
G1 LN 55-300 kW
G3 LN 80-550 kW
G5 LN 200-900 kW
G7 LN 250-1550 kW
G 30/2-A LN 300-1800 kW
G 40/1-B LN 400-2100 kW
G 40/2-A LN 500-2700 kW
G 50/1-B LN 500-3000 kW
G 50/2-A LN 600-4500 kW
G 60/2-A LN 625-5800 kW
G 70/1-B LN 700-7000 kW
G 70/2-A LN 800-8500 kW
19
- weishaupt -
®
RGL 30/2-A 3LN 250-2100 kW *) multiflam Technik
RGL 40/2-A 3LN 400-2800 kW
- weishaupt -
20
- weishaupt -
Content
• Applications
- weishaupt -
Case Study
BEFORE:
• Efficiency (Average) 76.5%
• NOx 38 PPM
• CO > 100 PPM
AFTER:
• Efficiency (Average) 82.5%
• NOx <25 PPM
• CO < 10 PPM
• Increased Turndown Ratio
• Reduced Electrical Consumption
21
- weishaupt -
Boiler Efficiency
Abstract:
A boiler operates for 8,000 hrs per year and consumes 500,000 MMBtu
of natural gas while producing 45,000 lb/hr of 150 psig steam. Stack
gas measurements indicate an excess air level of 44.9% with a net flue
gas temperature of 400°F. From the table, the boiler combustion
efficiency is 78.2% (E1) . Tuning the boiler reduces the excess air to
9.5% with a net flue gas temperature of 300°F. The boiler combustion
efficiency increases to 83.1% (E2) Assuming a steam value of
$4.50/MMBtu, the annual cost savings are:
- weishaupt -
Unilux
22
- weishaupt -
Boilersmith
- weishaupt -
23
- weishaupt -
- weishaupt -
Powermaster Retrofit
24
- weishaupt -
- weishaupt -
Weishaupt Canada
Weishaupt Corp.
6280 Danville Road
Mississauga, On L5T 2H7
Phone: (905) 564 0946
sales@weishaupt-corp.com
25
- weishaupt -
Weishaupt Canada
Weishaupt Corp.
6280 Danville Road
Mississauga, On L5T 2H7
Phone: (905) 564 0946
sales@weishaupt-corp.com
26