1 2 3 4 5 6 7 8

Actual OR
sounding Manual Auto
Measurement
H H
Trim/LIst
Correction

Low Level Screen display


Setpoint Screen display

Lower 1. Red text alarm in banner


G IF 2. Alarm Buzzer Sounds G
3. Indication Lamp Flickers

Greater
Hysteresis 1 No
Alarm Delay IF
Buzzer Stop
1
Yes
1 Red text alarm in
banner.
F 2. Indication Lamp Acknowledge
F
Flickers

No
IF
Yes

1. Alarm indication remains until


Level increases
E 2. Purple Text in banner
E

High Level
Setpoint

1 Red text alarm in


Greater banner.
D IF D
2. Indication Lamp
Flickers

Lower
Hysteresis 2 No
Alarm Delay IF
Buzzer Stop
2 Yes

C 1 Red text alarm in C


banner.
Normal Display 2. Indication Lamp Acknowledge
Flickers

No
IF
Yes

B B
1. Alarm indication remains until
Level descreases
2. Purple Text in banner

ACTech. Ltd
HULL NUMBER: HDBD-2005-008/009/010/012/ DATE
A 015 24-1-2007 A
The Technology of Control & Automation TITLE DRAWN BY
73 ETOLIKOU 18545 PIRAEUS GREECE A KOKKINOS
FLOW CHART OF LEVEL MEASUREMENT
Tel:+30 210 4630825 Fax:+30 210 4630725 PAGE
email: actech1@otenet.gr
AT BALLAST, FRESH WATER TANKS 1 OF 1