134 ETSI TS 102 221 V17.1.

0 (2022-02)

Table 11.34b: Coding of P2

b8 b7 b6 b5 b4 b3 b2 b1 Meaning
0 0 0 0 0 0 0 0 No information given
0 - - - - - - - Global reference data
1 - - - - - - - Specific reference data

NOTE: Parameter P2 = '00' indicates that no information on the identity requested is given. The identity is
implicitly known in the context of the selected application.

Command data (generic):

Byte(s) Description Length


1 to Lc Identity related data (see note) Lc
NOTE: The command data shall be specified by each application specific document.

Response data (generic):

Byte(s) Description Length


1 to Le Identity related data (see note) Le
NOTE: The response data shall be specified by each application specific document.

11.1.24 EXCHANGE CAPABILITIES


See ETSI TS 103 666-1 [34].

This clause does not apply to platforms which are not an SSP as described in ETSI TS 103 666-1 [34].

11.2 CAT commands


11.2.1 TERMINAL PROFILE

11.2.1.1 Functional description


This function is used by the terminal to transmit its CAT capabilities to the applications present on the UICC.

Input:

• Terminal profile, the structure of the data is defined in ETSI TS 102 223 [4].

Output:

• None.

11.2.1.2 Command parameters and data


Code Value
CLA As specified in clause 10.1.1
INS As specified in clause 10.1.2
P1 '00'
P2 '00'
Lc Length of the subsequent data field
Data Structure and coding defined in ETSI TS 102 223 [4]
Le Not present

ETSI
135 ETSI TS 102 221 V17.1.0 (2022-02)

11.2.2 ENVELOPE

11.2.2.1 Functional description


This function is used to transfer CAT information from the UE to the UICC.

Input:

• The structure of the data is defined in ETSI TS 102 223 [4].

Output:

• The structure of the data is defined in ETSI TS 102 223 [4].

11.2.2.2 Command parameters and data


Code Value
CLA As specified in clause 10.1.1
INS As specified in clause 10.1.2
P1 '00'
P2 '00'
Lc Length of the subsequent data field
Data Structure and coding defined in ETSI TS 102 223 [4]
Le Empty or maximum length of response data

Response data:

• Structure of the response data is defined in ETSI TS 102 223 [4] for CAT applications.

11.2.3 FETCH

11.2.3.1 Functional description


This function is used to transfer a proactive command from the UICC to the terminal (e.g. from a CAT application).

Input:

• None.

Output:

• Data string containing a proactive command for the terminal (e.g. a CAT command).

11.2.3.2 Command parameters and data


Code Value
CLA As specified in clause 10.1.1
INS As specified in clause 10.1.2
P1 '00'
P2 '00'
Lc Not present
Data Not present
Le Length of expected data

Response data:

• Structure of the response data is defined in ETSI TS 102 223 [4] for CAT applications.

ETSI
136 ETSI TS 102 221 V17.1.0 (2022-02)

11.2.4 TERMINAL RESPONSE

11.2.4.1 Functional description


This function is used to transfer from the terminal to the UICC the response to a previously fetched proactive command
(e.g. a CAT command).

Input:

• Data string containing the response.

Output:

• None.

11.2.4.2 Command parameters and data


Code Value
CLA As specified in clause 10.1.1
INS As specified in clause 10.1.2
P1 '00'
P2 '00'
Lc Length of the subsequent data field
Data Structure and coding defined in ETSI TS 102 223 [4]
Le Not present

11.3 Data Oriented commands


11.3.0 Overview and generic mechanism
This clause lists a group of data oriented command and response APDU formats that are used by applications residing
on a UICC. It is up to each application to determine which commands it uses. If an application does not support a
command, it shall return the appropriate status word, see clause 10.2.

The data transmitted is encapsulated in a BER-TLV data object structure and is formatted as follows:

Byte(s) Description Length


1 to T BER-TLV Tag 1 T 3
T+1 to T+L BER-TLV Length 1 L 4
T+L+1 to T+L+X BER-TLV Value X

The specific tag allocation scheme is beyond the scope of the present document.

However, the tag values, that shall be supported by the UICC and the terminal are defined as follows:

Tags of the context-specific class, coded on one to three bytes, shall be used for the TLV objects, i.e. tags shall be taken
out of the following ranges:

• '80' to '9E' and '9F 1F' to '9F 7F' and '9F 81 XX' to '9F FF XX' with 'XX' from '00' to 7F' for primitive objects;
and

• 'A0' to 'BE' and 'BF 1F' to 'BF 7F' and 'BF 81 XX' to 'BF FF XX' with 'XX' from '00' to 7F' for constructed
objects.

Terminals shall take into account that each tag value can only exist once in a file and thus an unused tag has to be used