You are on page 1of 1

50

25
5@25
125
3002H HTL100X100X8..855

open hole for

500
galvanizing purpose 3001A

246
75
3015H HT8 thk x272..70..PACK PLT 63
3015H TH8 thk ..PACK PLT 45
GROUND LEVEL 45

310
53

63 41
369

4-19.1x50.8 4-19.1x50.8
4-19.1x50.8 4-19.1x50.8
A

555
45

30
A 53 H
3004

06
HTL60X60X6..1550

H
G..2637

F . S.
G..2546
..2549
..2640

N.S.

31

3007H
3007H
1550
930

H
3004 HTL80X8 ING..2724

7@35

3005
3003 FOR CUT
HTL80X80X6

245
HTL80X80X6
FOR CUTTIN
FOR CUTTIN

H HT
H EARTHING

F.S. 3006H
FOR

N.S. 3004H

30
3001 ISMC 125x65..1550

03
L80X X6..2727

H
EQ

H
CUTT ..2640

H
3005
31

3003
80X6
F.S. 3006H
N.S. 3005H

ING..
0

310
T

F.S.
N.S.
2637

2700
2700

1-15.9 x44.45 1-15.9 x44.45


1-15.9 x44.45 3008H
1-15.9 x44.45
3002H HTL60X60X6..1550
3012H HTL50X50X6..606 N.S. 3013H HTL50X50X6..588
3006H 1550
3004H F.S. 3014H HTL50X50X6..589
VIEW ON B-B
3015H ..PACK PLT
BOTTOM PLAN
EQ

3003H
4-19.1x44.45 3005H
4-19.1x44.45 3015H ..PACK PLT 3001A
CLT.. 3009H 3009H HTL60X60X6..115..CLT 3009H ..CLT
C C
2-15.9 x44.45
VIEW ON A-A CLT.. 3009H
4-19.1x50.8
3020H 1-15.9 x44.45 1-15.9 x44.45
4-19.1x50.8

HTL50x50x6..920
B
120

3020H
1-15.9 x44.45 1-15.9 x44.45
N.S. 3001 ISMC 125x65..1550

3020H
2-15.9 x44.45 60
60
310 F.S. 3001A 930 310
310 930 310 B
1550
1550
TRANSVERSE FACE 1-15.9 x44.45 3001 1-15.9 x44.45

LONGITUDINAL FACE

VIEW ON C-C
TOP PLAN
1st SLOPE = 39168.49293

2nd SLOPE = 39336.26415

39000
F.S. 3017H HT10 thk x212..325..PLT
40 N.S. 3019H HT10 thk x212..326..PLT
40 29.16
3629.16 36
F.S. 3016H HT10 thk x212..326..PLT SLOPE DIAGRAM
N.S. 3018H HT10 thk x212..326..PLT 10
3@6
180
3@60
180

0
31

10
65
31
35

35

65 N.S: LADO CERCANO (NEAR SIDE)


120

F.S: LADO LEJANO (FAR SIDE)


TYP. DIMENSIONS SIMBOLOGIA PARA PERNOS
31 3@50 31 3@50 FOR `L' CUTTING ESPECIAL 12.7 DIA 15.9 DIA 19.1 DIA STEP BOLT

150 150
31 31

ITEM NOS. L.D. M.D. CONCESIONES

MARKING FROM MISSING MARK NO.


SANDIP SANDIP
26.04.2022 27.06.2022 Enlace 220 kV Tingo Maria – Aguaytia, Subestaciones, Lineas y
3001 TO 3020 3010,3011
Ampliaciones Asociadas
NOTES:-
PLANOS DE MONTAJE DE ESTRUCTURAS
1. All dimensions are in mm.
KALPATARU POWER TRANSMISSION LIMITED, India
2. All holes are 14.3Ø holes for 1 2" (12.7mm) Ø bolts ,17.5Ø for 5 8" (15.9mm) Ø bolts. & 20.6Ø holes for 3 4" (19.1mm) Ø bolts.
LT 220 kV Leoncio Prado - Aguaytia (LT07)
3. High tensile steel shall conform to ASTM A572-Gr. 50.
4. All steel members are to be hot dip galvanized according to ASTM A123 & bolts, nuts and washers as per ASTM A153. TORRE TIPO SSRD2200
5. Bolts and nuts shall conform to ASTM A394. Type `0' for bolts & ASTM A563 Gr. A. for nuts.
NB V.R.NIWATE VBG PSC MBN
6. Standard Regular helical spring lock washers according to ASME B 18.21.1-2009 to be supplied with each bolt. GRILLAGE SOIL TYPE S1
7. Min. rolled & cut edge security shall be 18 & 20mm for 1/2" Ø bolts , 20 & 24mm for 5/8" Ø bolts. & 24 & 29mm for 3/4" Ø bolts.
8. All item nos are to be prefixed with letter 390SR 390 390/SSRD2200-2
9. Mild steel shall conform to ASTM A36 for Channel Section.
10. torque value = 100.34nm ( 10.23 kgm. ) for 5/8” Ø bolts. & torque value = 178.13nm ( 18.17 kgm. ) for 3/4” Ø bolts. 29-03-22 1:25 mm
KAL-P117-E3-ING-LT07-1-PL-003 0