Is there a difference in air volume on the suction and discharge of the ventilator?
No. The given air volume is the same whether the ventilator is used as an exhauster or blower. However, there is a significant
difference in the air velocity at a given distance away from the fan. For example: One foot away from the intake (exhaust) end of a
12” fan the air velocity will drop 90% compared to only a 3% drop on the outlet (blower) side (see illustration below).
INLET AND OUTLET VELOCITY CHARACTERISTICS DECIBEL LEVELS: Sound data on COPPUS products is
Air velocity is reduced as the distance from the fan increases on both the inlet based on tests conducted with units operating at
published speeds. No attachments for attenuating sound
(exhaust) and outlet (delivery) sides. However the rate of reduction in air were used. dBA levels recorded at 5’ (1.5 m)
velocity is significantly greater on the inlet side of the fan
ELECTRIC
d 30d
ITEM dBA ITEM dBA
Vano 175CV 90 18K03D 72
Vano 250CV 92 24K07D 79
Suction Supply Vano 500 89 24K10D 85
FAN
ColdFront
Industrial Kit Electric N/A N/A
Turn any COPPUS fan into 12
a “super cooler”
Marine Steam, Air 12” & 15” 4,600-8,400 Cargo tank ventilators. Mates 22
Ventilators and Water Axial (7,815-14,275) to 12 1/2” deck opening
RF-12 /RF-16 Compressed Air 12” & 16” 2,140-5,100 Ideal for hazardous locations.
18-19
(Reaction Fans) or steam Axial (3,636-8,665) All aluminum cast housing
RF-20 / RF-24 Compressed Air 20” & 24” 11,000-16,900 Bolts directly to tanks with
standard API manways 19-20
(Reaction Fans) or steam Axial (18,689-24,805)
Vaneaxial:
• Patented Convert-a-Bell inlet converts unit from blower
to blower/exhauster. 8” Flexible duct can be attached to
both inlet and outlet ends (optional on EV models).
• Flame resistant UL94-V2 rated composite on polymer
housing.
• Glass filled, polyester resin, spark resistant fan blade.
• Accommodates 8” flexible duct.
• Optional attachable duct canister (see page 8).
MODEL CGM
3 HP Gasoline engine with 5’
metal flex exhaust hose.
Centrifugal:
• Excellent airflow and pressure performance.
• Flame resistant UL94-V2 composite on polymer
Hazardous Location Models housing.
• Glass filled, polyester resin spark resistant fan blade.
Hazardous Location:
• Housing and components are constructed of special
conductive polymers for safe dissipation of static
charges.
• Electric motors meet NEC Class 1, Division 1, Group D;
Class ll, Division 1, Groups. E,F,G
MODEL CEP
Hazardous Location
• Available in Vane-axial and Centrifugal models.
Electric or Air Drive
CADET® SPECIFICATIONS
Vaneaxial Models
WEIGHT FREE AIR Performance through 900 bend(s)
MODEL DRIVE MOTOR HP 1-900 2-900 3-900
lbs kg cfm m3/hr cfm m3/hr cfm m3/hr cfm m3/hr
VAC1 Electric-115V/60Hz TE 1/2 35 16 867 1465 776 1318 766 1301 756 1284
VAC2 Electric-110V/50Hz TE 1/2 35 16 804 1358 730 1240 720 1223 710 1206
VAC3 Electric-230V/60Hz TE 1/2 35 16 867 1465 776 1318 766 1301 756 1284
VAC4 Electric-220V/50Hz TE 1/2 35 16 804 1358 730 1240 720 1223 710 1206
EV1 Electric-115V/60Hz TE 1/4 27 12 1300 2197 730 1240 659 1119 602 1023
VEP1 Electric-115V/60Hz EP 1/2 35 16 867 1465 776 1318 766 1301 756 1284
VEP2 Electric-110V/50Hz EP 1/2 35 16 804 1358 730 1240 720 1223 710 1206
VEP3 Electric-230V/60Hz EP 1/2 35 16 867 1465 776 1318 766 1301 756 1284
VEP4 Electric-220V/50Hz EP 1/2 35 16 804 1358 730 1240 720 1223 710 1206
Centrifugal Models
Performance through 900 bend(s)
WEIGHT FREE AIR
MODEL DRIVE MOTOR HP 1-900 2-900 3-900
lbs kg cfm m3/hr cfm 3
m /hr cfm 3
m /hr cfm m3/hr
CAC1 Electric-115V/60Hz TE 1/2 35 16 1014 1722 860 1461 845 1436 830 1410
CAC2 Electric-110V/50Hz TE 1/2 35 16 845 1428 717 1218 704 1196 692 1176
CAC3 Electric-230V/60Hz TE 1/2 35 16 1014 1722 860 1461 845 1436 830 1410
CAC4 Electric-220V/50Hz TE 1/2 35 16 845 1428 717 1218 704 1196 692 1176
CEP1 Electric-115V/60Hz EP 1/2 35 16 1014 1722 860 1461 845 1436 830 1410
CEP2 Electric-110V/50Hz EP 1/2 35 16 845 1428 717 1218 704 1196 692 1176
CEP3 Electric-230V/60Hz EP 1/2 35 16 1014 1722 860 1461 845 1436 830 1410
CEP4 Electric-220V/50Hz EP 1/2 35 16 845 1428 717 1218 704 1196 692 1176
CGM1 Gasoline N/A 3 42 19 1058 1783 897 1524 882 1504 866 1471
Dimensions (in/mm)
Vaneaxial Models
Centrifugal Models
14.5 15.63
368.3 397 18.61
8 472.6
FEATURES:
• Straightening vanes for
improved static pressure performance.
• Accepts ducting on inlet and outlet ends.
• Available with Totally Enclosed (TE) or Explosion
Proof (EP) motors and compatible switch. All single
phase models supplied with 15’ power cord.
• Heavy gauge, powder coated steel and cast alumi-
num construction.
• Spark resistant fan blades.
Convertible Design • Removable sleeve on 175CV and 250CV converts
Simply by removing the inlet sleeve the 175CV inlet from accepting duct to side-cutout version for
and 250CV converts to a vertical exhaust unit. exhausting fumes from bottom of tanks (see below
for more details).
• Automatic reset thermal overload protection
standard on VANO 175CV and 250CV models.
• Optional Tripod and Transport Cart available.
(see page 8 for details)
PERFORMANCE
cfm (m3/hr) at Various Static Pressures cfm (m3/hr) Air Flow Through Duct (Straight Runs)
0.5 in. WG 0.75 in. WG 1.0 in. WG 10 ft. 20 ft. 30 ft. 50 ft.
Model
FREE AIR 13 mm 19 mm 25 mm Model 3.05 m 6.10 m 9.15 m 15.25 m
cfm m3/hr cfm m3/hr cfm m3/hr cfm m3/hr cfm m 3/ hr cfm m 3/ hr cfm m 3/ hr cfm m 3/ hr
175CV 1500 2549 1350 2294 1280 2175 1230 2090 175CV 1400 2379 1300 2209 1200 2039 1080 1835
250CV 3000 5098 2620 4452 2480 4214 2300 3908 250CV 2940 5098 2620 4452 2480 4214 2300 3908
DIMENSIONS
B
250CV 12 36 12 15.62 13.25 93 12
Sleeve
Installed 305 914 305 397 337 41 305
ELECTRICAL SPECIFICATIONS
VANO Models available with Totally Enclosed MODEL VOLTAGE SWITCHES PLUG TYPE
(TE) or Hazardous Location, (explosion proof, Volts Ph Hz TE EP TE EP
EP) , Class 1, Division 1, Group D; Class ll,
Division 1, Groups E, F, G motors. 175CV and 175CV 115 1 60 Built-in Built-in Included Optional
250CV models include automatic reset and 175CV 230 1 60 Built-in Built-in Optional Optional
thermal overload protection. All models include 175CV 220 1 50* Built-in Built-in Optional Optional
15’ heavy duty elctrical cord. Plugs for EP models
250CV 115 1 60 Built-in Built-in Optional Optional
must be specified in writing or supplied by
customer to conform to local code for factory 250CV 230 1 60 Built-in Built-in Optional Optional
installation or installed by the customer (recom- 250CV 230 3 60 External External Optional Optional
mended). 250CV 460 3 50* External External Optional Optional
FEATURES:
SPECIFICATIONS:
Fixed guide vanes improve air
flow and provide added MOTOR: TE 3/4 HP, with integral on/off switch, 115V/6.8
protection for fan blade. amp, class B insulation, auto reset thermal overload
protection. Attached 20’ heavy duty cord with GFCI
shut-off at plug end.
FREE AIR: 2,200 CFM
WEIGHT: 44 Lbs. (18.14 Kg)
HOUSING: 18 gage steel, powder coated with carry
handle and anti-vibration foot pads. Rolled bead on ends
Integral switch on motor for added strength and attaching flexible ducting.
as well at the plug end for Attached, OSHA approved safety screens.
added safety and conve-
nience. FAN BLADE: True airfoil, glass reinforced polypropylene.
FIXED GUIDE VANES: For improved air flow performance
through duct.
DIMENSIONS:
CFM (m3/hr) Air Flow Through Duct (Straight Runs)
Air Max 2200 3740 2120 3602 2025 3440 1890 3211
TA16
NOW AVAILABLE with Delivers Large Volume,
1 1/2 HP, 115 V Motor
High Static Pressure.
The unique fan blade design not only allows exceptional high air
volume but also maximizes static pressure for better performance
through longer runs of air duct. Typical ventilation applications
include large tanks, tunnels, towers, and shipboard compart-
ments. Also ideal for product and process cooling.
FEATURES:
• Available as Totally Enclosed (TE) or Explosion Proof (EP),
manual start motors.
• Thermal overload protection starter.
• Powder coated, heavy steel gauge housing.
• Cast aluminum fan blade provides spark resistant construction.
• Skid mounted for stablitiy(optional casters avaialble).
Electical Specifications • Duct can be connected at inlet and outlet ends.
MODEL VOLTAGE CFM (m3/hr) air flow through flexible duct (straight runs)
Note: Plugs supplied Volts Phz. Freq.
for 115V TE units. 10’ 50’ 100’
230 1 60
Optional plugs supplied Model
2 HP 230 3 60 (3.05 m) (15.25 m) (30.5 m)
for all other models
460 3 60
when type is specified TA16-5000 CFM (m3/hr) CFM (m3/hr) CFM (m3/hr)
by customer in writing. 575 3 60
1 1/2 HP 5,320 (9,039) 4,775 (8,113) 4,25 (7,721)
11/2 HP 115 1 60
DIMENSIONS: (in./mm)
26
16 660
460
11.4
290
23.6
597
Accessories
Flexible Air Duct
COPPUS carries a large selection of flexible air duct for a
variety of ventilation application needs. Our most popular
Heavy Duty Duct features impregnated polyester duct
designed for harsh, industrial environments. Our other
selections include: Economical Light Duty Duct, Source
Capture Duct and Hazardous Location, Anti-static Duct.
JECTAIR TRIPOD
VANO TRANSPORT CART Rotates 360 degrees for accurate
Heavy duty cart allows easier direction of air flow. Accomodates
transportation of VANO 175CV and all Jectair sizes. Installs quickly and
easily with two quick-release clamps.
250CV. VANOs can remain on cart
during operation. Includes crane Large foot pads provide extra stability
lifting loop. Weight: 25lbs (11kg) during operation. Spring loaded legs fold
up for easy transportation and storage.
SOURCE CAPTURE
DUCT HOODS
VANO TRIPOD Maximize the effectiveness of
Attaches to VANO 175CV or 250CV. fume and particle exhaust
Makes positioning of units and during welding operations
direction of airflow easier by rotating with a COPPUS duct hood.
3600 on a 450 plane. Spring loaded Attaches quickly and easily to
legs fold up for easy transport and COPPUS source capture 4”,
storage. Weight: 19 lbs (9 kg.) 5” or 6” duct.
COPPUS® COLDFRONT
Evaporative Cooling System
Evaporative cooling has been recognized for years as an economical and efficient way
to reduce ambient temperatures in high heat stress environments. COPPUS has
harnessed the power of evaporative cooling with their Industrial Coldfront and
Compact ColdFront kit.
Industrial ColdFront
Transforms high velocity COPPUS fans into “super coolers” capable of reducing high
ambient temperatures up to 400 F.
FEATURES:
• Heavy gauge powder coated steel enclosure.
• 10” pnuematic wheels and front locking caster for easy mobility.
• High pressure quick-connect hose
• Heavy duty, 1200 PSI triplex bronze pump accomodates up to 6 misting rings
• 5 micron water filter.
• Kit includes: 25’ high pressure hose, 20” or 16” stainless steel misting ring
with 6 replaceable .008 misting nozzles.
COLDFRONT® Specifications
PUMP INDUSTRIAL COMPACT NEW!
Pressure range 500-1200 psi 500-1200 psi AT-24 Heat Killer
Type Tri-Plex Plunger Tri-Plex Plunger ColdFront.
GPM (Max.) .122 GPM .122 GPM The ColdFront Compact
Motor HP/AMPS 1 HP / 12.8 AMPS 1 HP / 12.8 AMPS Kit now has a great
Output ports 1-Quick Connect 2-Quick Connect companion fan. The new
AT-24 Heat Killer is ideal
Enclosure Powder Coated Steel High Impact
Plastic Case for indoor and outdoor
evaporative cooling
Water use/ring 0-7.32 g/hr. @ 700psi 0-7.32 g/hr. @ 700psi
applications.
Water Filter 5 Micron 5 Micron (see page 13 for more
Misting Ring Stainless Steel tubing with 6 replaceable .008 brass details).
nozzles.16” and 20” diameter sizes.
Ventair® TM
High Pressure Centrifugal Blower/Exhauster
This is a rugged, high volume, high pressure centrifugal fan. Backwardly
inclined fan blades yield stable air flow through small diameter or long
runs of duct. The high static pressure capabilities makes this an ideal
air mover for suppling fresh air or exhausting welding fumes for multiple
remote locations.
FEATURES:
• Available with: 1 HP, 2 HP, 5 HP, 15 HP and 30 HP Motors.
• Air flows up to 10,700 cfm (18,179 m3/hr).
• One piece, cast aluminum, spark resistant, abrasion resistant,
dynamically balanced fan wheel.
• Heavy gauge steel housing and base protects fan and motor.
• Backward curved airfoil shaped blades provide non-overloading
characteristics allowing peak performance over long runs of duct.
• Totally Enclosed (TE) and Explosion Proof (EP)
motors available.
PERFORMANCE: cfm (m3/hr) air delivery at 3500 rpm • 3500 rpm motor directly connected to fan wheel.
STATIC PRESSURES IN Wg. (mm)
Model HP Free 1” 2” 3” 4” 5” 6” 7” 8”
Air 2mm 51mm 76mm 102mm 127mm 152mm 178mm 203mm ELECTRICAL SPECIFICATIONS
TM-4 1 1700 1560 1400 1230 1040 820 340 - - Available with Totally Enclosed (TE) or Hazardous
2837 2604 2379 2090 1767 1933 578 -- -- Location (EP) motors. (Class l, Division 1, Group D;
Class ll, Division 1, Groups F,G).
TM-5 2 2500 2300 2100 1900 1680 1450 1200 910 500 Single phase (TM-4 only).
4248 3908 3568 3228 2854 2464 2039 1546 850
OPTIONS & ACCESSORIES
TM-6 5 4100 3930 3740 3560 3360 3140 2930 2700 2460
6966 6677 6354 6048 5709 5335 4978 4587 4180 • Motor starters
• Beaded or flanged diffusers.
TM-8 15 7450 7250 7000 6800 6600 6350 6100 5900 5659
12558 12318 11893 11553 11213 10789 10364 10024 9599 • Flexible duct.
• Adapter for multiple inlets.
TM-9 30 10700 10400 10100 9800 9550 9250 8950 8700 8400
18179 17674 17165 16665 16230 15720 15210 14785 14275 • Forklift mount.
• Optional outlet arrangements.
• Vibration Isolators.
B K
Portavent®
Versatile Centrifugal Ventilator for Source
Capture Fume Exhaust.
Design, performance and versatility of the PORTAVENT® make it
an ideal ventilator for a wide range of industrial applications.
Welding and other fume removal, purging small tanks, equip-
ment cooling, confined space ventilations and other mainte-
nance and safety applications.
FEATURES:
• Available in 3 models offering 560 to 940 cfm
(951 to 1597 m3/hr).
• Direct drive 3500 RPM fan.
• Cast aluminum fan and housing provides spark
resistant construction.
• Unique multi-position stand offers a variety of
convenient set-ups.
• Accepts flexible duct on inlet and outlet ends.
• Backwardly inclined airfoil blades prevents
PERFORMANCE: motor overloads.
cfm (m3/hr) air delivery at 3500 rpm • Inlet and outlet screens meet OSHA guidelines.
Inlet Duct Length of duct-straight runs • Totally Enclosed (TE) and Explosion Proof (EP)
Model HP No. Size 10’ 20’ 30’ 40’ 50’ motors available on all models.
(in./mm) 3m 6m 9m 12m 15m
1 5 525 488 460 440 425 DIMENSIONS: Inches/(mm)
PV-500 1/2 127 892 829 782 748 722
Wgt. lbs/kg
2* 4 262 249 235 225 214
102 445 423 399 382 364 Model A B C D E F G TE EP
1 6 775 740 708 690 670 PV-500 22.4 14.8 19.0 9.5 8.4 5.4 4.9 57 60
PV-750 3/4 152 1317 1257 1203 1172 1138 569 376 483 241 213 137 124 26 27
2* 5 395 382 368 360 352
127 671 649 625 612 598 PV-750 22.9 15.6 19.0 9.5 9.3 5.9 5.9 69 72
1 6 870 830 800 765 745 582 396 483 241 236 150 150 31 32
PV-1000 1 152 1478 1410 1359 1300 1266
PV-1000 22.9 15.6 19.0 9.5 9.3 5.9 5.9 70 73
2* 5 450 430 415 405 395 582 396 483 241 236 150 150 32 33
127 765 731 705 688 671
ELECTRICAL SPECIFICATIONS A
E
B
Voltage Switch
Models Volts Ph. Freq. TE EP G
FEATURES:
• Patented, adjustable guide vanes allow
varied air movement from gentle breeze
to jet blast.
• Available in 18”, 24” and 30” models.
• Models available in floor stand (high
and low style) or wall mount (stationary
and oscillating).
• Heavy duty, rugged steel housing and frame.
• Trade marked design for enhanced
performance.
• Protective screens meet OSHA standards.
• Available with Totally Enclosed (TE) and
Explosion Proof (EP) motors.
• Hazardous Location switches and motors meet
NEC Class I, Division I, Group D and Class II
Division I, Groups F & G. Thermal overload
protected.
Fan Size Motor Air Volume 10’/3m 30’/9m 50’/15m 70’/21m 90’/27
Model In. mm HP rpm cfm m3/hr Model JB* DF* JB DF JB DF JB DF JB
18K03D 1100 425 450 260 350 180 275 135 -
18K03D 18 457 1/3 1750 4100 6970 335 130 137 79 107 55 84 41 --
24K07D 24 610 3/4 1750 7100 12,060 24K10D 1675 670 840 375 560 280 350 230 185
AT-24** 511 204 256 114 171 85 107 70 56
24K10D 24 610 1 1750 9500 16,140 30K30D 2250 1280 1000 520 900 340 700 310 475
AT-24 (EP 1.5)
686 390 304 159 274 104 213 95 145
30K30D 30 762 3 1750 17,000 28,890 *Jet Blast (JB), Diffused Flow (DF)
**Fixed guide vanes only. (JB schedule applies)
DIMENSIONS
FLOOR STAND MODELS- Inches/(mm)
H
B G-Stand Net*
Fan A B C D E F
F
High Low Wt.
Size
A C
18in. 23.0 21.2 21.2 24.8 26.8 11.5 42.0 24.0 130lbs
457mm 584 540 540 629 679 292 1067 610 59kg
24in 32.4 25.0 28.1 29.5 32.8 16.2 42.0 28.0 147lbs
G 610mm 882 635 714 749 832 411 1067 711 67kg
AT-24 32.4 25.0 28.1 0 32.8 16.2 49” N/A
610mm 882 635 714 0 832 411 49”
30in. 37.0 28.0 33.4 33.2 38.8 18.5 44.0 32.0 240
D E 762mm 940 711 848 846 984 470 1118 813 109kg
*Weights are for TE Motors with high stand
JECTAIR®
HP and Hornet HP
FEATURES:
• Available in 5 sizes: 9, 8, 6-HP, 3-HP, 3S-HP
• HI Performer (HP) and Hornet models available in 3 sizes: 6-
HP, 3-HP and 3S-HP
• Air flows range from 1370 to 8900 cfm (2,328 to
15,121m3/hr)
• Induction ratios up to 40:1.
• Multiple expansion nozzles machined into housing.
• High static pressure capabilities.
• Diffuser material available in steel, aluminum or shock
resistant polymer (Hornet HP).
• Steel diffusers protected by safety yellow, epoxy base powder
coating with conductive filler to help dissipate
static charge.
• No moving parts - Virtually maintenance free.
JECTAIR ®
HORNET HP • Static bonding cable with spring tension grip and replaceable
contact tips standard on all models.
The Jectair Hornet HP features a light weight, shock
resistant, conductive polymer diffuser that is virtually • Accepts flexible duct on diffuser end (optional duct adapter for
indestructible. inlet end available).
• Tripod for stationary mounting available (see accessories on
page 8 for more information).
OPERATING PRINCIPLE:
Compressed air or steam is admitted to the Jectair through
a single inlet connection in the housing leading to the
mixing chamber. The air or steam jetted from the nozzle
creates a Venturi action which induces a large volume of
• Available in 3 sizes: 3S-HP, 3-HP & 6-HP surrounding air to enter the Jectair through the inlet bell.
The air is then discharged at high velocity through the horn
• Polymer safely dissipates static electric charges. shaped diffuser.
• Diffuser is constructed of linear low density polyethyl-
NOTE: Operating efficiency is dependent upon compressed
ene, rated UL 94-V2 with maximum operating tempera-
air volume and pressure (see performance/efficiency charts
ture of 160 0F (93 0C) on following page).
COPPUS® PORTABLE VENTILATORS—17
18 ! Click here to return to index
Reaction Fans
RF-12, RF-16,
RF-20, RF-24
Air Driven Reaction Fans
Rugged, cast aluminum housing and fan blade make these fans ideal
for hazardous locations and demanding ventilation projects. The RF
design utilizes action-reaction principles. Compressed air is dis-
RF-12
charged through nozzles located at the tip of the fan blades providing
extremely efficient, high volume, low maintenance air movers.
FEATURES:
RF-12, RF-16
• 2100 to 5100 cfm (3,566 to 8,665 m3/hr) at 80 psig.
• Use for fresh air supply or fume exhaust.
• Low compressed air consumption.
• Spark resistant cast aluminum housing and fan blade.
• Virtually maintenance free.
• Permanently lubricated bearings eliminate line oiler.
• Cast in handles and feet.
RF-16 • Cast in bead to accept 12” and 16” duct.
• Bolt holes allow attachment of optional face plates.
RF-20, RF-24
• 11,000 to 16,900 cfm (18,689 to 28,713 m3/hr) at 80 psig.
• Use for fresh air supply or fume exhaust.
• Can be carried or rolled to job site.
• Spark resistant cast aluminum housing and fan blade.
• Permanently lubricated bearings.
• Flanges mate with 20” (508mm) and 24” (610mm) API
tank opening.
.
RF-20 PERFORMANCE
RF-12, RF-16 PERFORMANCE
Air flow through Flexible Duct at 80 psig (cfm/m3/hr)
F A
C
E D
B B
G D
C Bolt Slots
Model A B C D E Size No. Wt.
Model A B C D E F G Wt.
RF-12 14.5 6.4 12.0 10.5 10.9 11.8 10.8 39lbs RF-20 10.2 24.7 19.5 22.5 3/4 1.12 4 69lbs
368 163 305 267 276 299 273 18kg 260 629 495 572 19 28.4 31kg
RF-16 16.4 8.4 17.4 14.5 15.4 15.8 12.0 50lbs RF-24 11.6 31.2 24.0 30.2 1 1.12 4 160lbs
416 213 442 368 391 401 305 23kg 294 794 610 768 25 28.4 73kg
CP-20
FEATURES:
Star ILLUSTRATION 1A
Tolerance
Inlet Screen Ring (2)
End Cap DIMENSIONS 1/2” (13 mm) Inlet for
Inlet Casing Ball Bearing (2) 3/4” (19 mm) Inlet for 80-150 PSIG (5,6-10,5
Shaft 80 PSIG kg/cm2) Max.
Support Strut Pressure/Air or
(5,6 kg/cm2) Max.
Bucket Ring Steam
Pressure
Air or Steam
25” (635 mm) 1.1”
(28 mm)
20.1” (24 mm)
Air Flow
0.9” (24 mm) 22.5”
(572 mm)
AIR FLOW
DIMENSIONS (inches/mm)
Bolt Slots Wt.
Model A B C D E F Size No. lbs/kg
DIMENSIONS in./(mm)
Steam or Compressed Air Turbine Drive Water Turbine Drive
1 1/2” (38 mm)NH Water
3/4” (19 mm) Outlet Connection
2” (50 mm) Relief Steam Inlet (NPT)
Exhaust (NPT) Valve 1 1/2” NH Water
Inlet Connection
A
A
B
B
D D
E Bolt Circle E Bolt Circle
F F
C C
Marine Venturi
Lightweight Deck Mount,
Compressed Air Drive Ventilator
Easy to transport, rugged and versatile ship-board ventilator for
degassing or delivering fresh air supply to cargo tanks and
other on-board confined spaces.
FEATURES:
PERFORMANCE
Inlet Total Air Induction
Pressure Airflow Consumed Ratio
cfm/m3/hr scfm/m3/hr