Professional Documents
Culture Documents
B E
F
I
BUILDER G
A
F
I
4/22 1 of 5
DLE3400W / DLG3401W
B E
F
I
BUILDER G
A
F
I
OPTIONAL ACCESSORIES DIMENSIONS
Pedestal WDP4W Product (W x H x D) 27" x 38 11/16" x 30 1/8"
Pedestal (W x H x D) 27" x 13 5/8" x 28" Depth with Door Open 51 3/8"
Short Pedestal WDPS1W Cutout Dimensions (W x H x D) 29" x 38 11/16" x 35 1/8" (32 1/8" D
Short Pedestal (W x H x D) 27" x 5 1/8" x 27" for Side or Bottom Venting)
Stacking Kit KSTK1 Carton Dimensions (W x H x D) 29 19/32" x 43 3/8" x 31 3/8"
Drying Rack 3750EL1001D Approx. Weight (Product / Carton) Electric: 122 lbs. / 135.2 lbs.
Gas: 124.7 lbs. / 137.9 lbs.
LP Conversion Kit 383EEL3002D
LIMITED WARRANTY
Side Vent Kit 3911EZ9131X (Replaces
383EEL9001B) Parts and Labor 1 Year
Dryer Drum 10 Years (Parts Only)
DLE3400_DLG3401
DIMENSIONS / CLEARANCES
Clearances INSTALLATION
SPACING FOR RECESSED AREA OR CLOSET INSTALLATION
14" max.* 14" max.*
(356 mm) (356 mm) The following clearances are recommended for this dryer. This
dryer has been tested for clearances of 1 inch (2.5 cm) on the sides
and rear. Recommended clearances should be considered for the 48 in.2*
18" min.*
18" min.* (457 mm) following reasons:
(310 cm 2 )
(457 mm)
• Additional clearances should be considered for ease of installation
and servicing.
• Additional clearances should be considered on all sides of the
dryer to reduce noise transfer. For closet installation, with a door,
minimum ventilation openings in the top and bottom of the door 24 in.2*
are required. Louvered doors with equivalent ventilation openings (155 cm 2 )
are acceptable.
Closet Door V
1"* 30 1/8" 5"** 1"* 30 1/8" 5"** Closet Ventilation Requirements
Requirement
(25 mm) (765 mm) (127 mm) (25 mm) (765 mm) (127 mm) Closets with doors must have both an upper and lower vent to
prevent heat and moisture buildup in the closet. One upper vent * Required s
** For side or
opening with a minimum opening of 48 sq. in. (310 cm2) must
be installed no lower than 6 feet above the floor. One lower vent
opening with a minimum opening of 24 sq. in. (155 cm2) must be
installed no more than one foot above the floor. Install vent grills
INSTALLATION
in the door or cut down the door at the top and bottom to form
openings. Louvered doors with equivalent ventilation openings are For cabinet inst
3"* (76 mm) also acceptable.
48 in.2*
(310 cm 2 )
0"
(0 mm)
39"
(990 mm)
24 in.2*
(155 cm 2 )
3"* (76 mm)
Closet Door Vent 1" 27" 1" 1"* 27" 1"*
Requirements (25 mm) (686 mm) (25 mm) (25 mm) (686 mm) (25 mm)
* Required s
4/22 2 of 5
DLE3400W / DLG3401W
B E
F
I
BUILDER G
A
F
I
DIMENSIONS / CLEARANCES
INSTALLATION
INSTALLATIONSPACING
SPACINGFOR
FORRECESSED
RECESSEDAREA
AREAOR
ORCLOSET,
CLOSET,WITH
WITHSTACKED
STACKEDWASHER
WASHERAND
ANDDRYER
DRYER
LLATION
LLATION
er.
er.This
This 3"* (76 mm)
6"*
6"*(152 mm)
(152 mm)
on 3"* (76 mm)
onthethesides
sides 48 2*
ed forthe
d for the 48in.
in.2*
(310 cm 22)
(310 cm )
finstallation
installation 77 11/2"
77 mm)
(1968 /2"
(1968 mm)
ssof
ofthe
the
with
withaadoor,
door,
24 2*
f the
of thedoor
door 24in.
in.2*
on (155 cm 22)
onopenings
openings (155 cm ) 3"* (76 mm)
3"* (76 mm)
Closet Door Vent
Closet Door Vent 1"*
1"* 5511/2/2"** 1" 27" 1"
"** (25 1" (68627" (25 1"
Requirements (25 mm)
Requirements (140 mm) mm) mm) mm)
vent
venttoto (25 mm) (140 mm) (25 mm) (686 mm) (25 mm)
per vent * Required spacing
pper vent * Required spacing
** For side or bottom venting, 2-inch (51 mm) of spacing is allowed.
)must
must ** For side or bottom venting, 2-inch (51 mm) of spacing is allowed.
ower
owervent
vent
)must
mustbebe
vent
ventgrills
grills INSTALLATION
INSTALLATIONSPACING
SPACINGFOR FORCABINET
CABINET
mtotoform
form For
penings
peningsare are For cabinet installation with adoor,
cabinet installation with a door,minimum
minimumventilation
ventilationopenings
openingsininthe
thetop
topof
ofthe
thecabinet
cabinetare
arerequired.
required.
7"* 7"*
7"*(178 mm)
7"*(178 mm)
(178 mm) (178 mm)
9"*
9"*
(229 mm)
(229 mm)
)
m)
5" 30
30 1/8/8""
1 1" 1" 27" 1"
(1275" 1"
mm) (765 mm) (25 mm) mm) (68627"
(25 1" mm) (25 1"
mm)
* Required spacing (127 mm) (765 mm) (25 mm) (25 mm) (686 mm) (25 mm)
* Required spacing
4/22 3 of 5
DLE3400W / DLG3401W
B E
F
I
BUILDER G
A
F
I
VENTING THE DRYER DUCTWORK
• If connecting to existing ductwork, make sure it is suitable and clean before installing the
dryer. Maximum length
Number of
• Venting must conform to local building codes. Wall Cap Type of 4-inch diameter
90° Elbows
• Gas dryers MUST exhaust to the outdoors. rigid metal duct
Recommended 0 65 ft. (19.8 m)
• Use only 4-inch (10.2 cm) rigid, semi-rigid or flexible metal ductworkinside the dryer cabinet
and for venting outside. 1 55 ft. (16.8 m)
4"
• The exhaust duct must be 4 inches (10.2 cm) in diameter with noobstructions. The exhaust (102 mm) 2 47 ft. (14.3 m)
duct should be kept as short as possible. Make sure to clean any old ducts before installing
your new dryer. 3 36 ft. (11.0 m)
4"
• Rigid, semi-rigid or flexible metal ducting is recommended for usebetween the dryer and (102 mm) 4 28 ft. (8.5 m)
the wall. All non-rigid metal transition duct must be UL-listed. Use of other materials for Use only for short 0 55 ft. (16.8 m)
transition duct could affect drying time. run installations 1 47 ft. (14.3 m )
• Ductwork is not provided with the dryer. You should obtain the necessary ductwork locally.
The vent hood should have hinged dampers to prevent backdraft when the dryer is not in use. 2 41 ft. (12.5 m)
• The total length of flexible metal duct must not exceed 8 ft. (2.4 m). 2 1/2" 3 30 ft. (9.1 m)
(635 mm)
NOTE: 4 22 ft. (6.7 m)
• Deduct 6 ft. (1.8 m) for each additional elbow. Do not use more than four 90° elbows.
4/22 4 of 5
DLE3400W / DLG3401W
B E
F
I
BUILDER G
A
F
I
CONNECTING GAS DRYERS ELECTRIC & GAS CONNECTION LOCATIONS
Electric & Gas Connection Locations
Gas Supply Requirements
• As shipped from the factory, this dryer is configured for use with natural Power
gas (NG). It can be converted for use with propane (LP) gas. Gas pressure Terminal
Cord
must not exceed 8-inch (20.4 cm) water column for NG, or 13-inch Block
(gas
Access
(33.1 cm) water column for LP. models)
Panel
• A qualified service or gas company technician must connect the dryer to (electric
the gas service. models)
Electrical Requirements for Gas Models Only
• This dryer must be plugged into a 120-VAC, 60-Hz. grounded outlet
protected by a 15-ampere fuse or circuit breaker.
Gas
• This dryer is equipped with a three-prong grounding plug for protection connection
against shock hazard and should be plugged directly into a properly (gas models) Exhaust Duct Outlet
grounded three-prong receptacle. Do not cut or remove the grounding
prong from this plug.
© 2022 LG Electronics USA, Inc. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. All other product and brand names are
trademarks or registered trademarks of their respective owners. Design, features and specifications are subject to change without notice. Non-metric
weights and measurements are approximate. Some features may require Internet access. Content and services may vary by product and are
subject to change without notice. 4/22 5 of 5