Professional Documents
Culture Documents
VIVA IRAIL System Product Data
VIVA IRAIL System Product Data
these two essential building elements into one. VIVA’s iRail™ is engineered with high
ADDITIONAL OPTIONS performance and long lasting LED’s. Available in a cool and warm white colors, light
intensities and housing profiles, this ADA compliant rail can be used for interior and exterior
applications.
GRANDSCAPE BOARDWALK
PRODUCT: iRAIL™ | INFILL: PICKET PANEL
THE COLONY, TEXAS
Technical Data
TECHNICAL DATA
Specifications
iRAIL RAILING SYSTEM - SPECIFICATIONS
™
US
LISTED
(3) 2700K Warm Whiteand 3500K Natural White available upon request.
Intertek
I
1454 HALSEY WAY, CARROLLTON, TX 75007
Page 2 of 5
V
A
P: 972-353-8482 F: 972-353-0013
e: info@vivarailings.com www.vivarailings.com
L
Illuminated Railing
PO
W
ER
SU
PP
LY
12
VD
C
ELECTRICAL CONDUIT MINIMUM 12"
DRIVER ABOVE FINISH FLOOR
FURNISHED BY VIVA (BY OTHERS)
INSTALLED CONCEALED BY
18" LICENSED ELECTRICIAN iRAIL WIRE FEED
22° ASYM. SYM. POD 24" 14 AWG WIRE, 35'-0" MAX. LENGTH
POD OR 36" (BY OTHERS)
PROVIDE ONE PAIR OF WIRES 14 GA (BLACK-RED) FOR EVERY iRAIL RUN. EVERY iRAIL RUN
COVERS:
· 32ft MAX FOR iRAIL LINEAR MEDIUM INTENSITY (3 W/ft)
· OR 16ft MAX FOR iRAIL LINEAR HIGH INTENSITY (5 W/ft)
POD
· OR 32ft MAX FOR iRAIL POD
I
1454 HALSEY WAY, CARROLLTON, TX 75007
Page 3.1 of 5
V
A
P: 972-353-8482 F: 972-353-0013
e: info@vivarailings.com www.vivarailings.com
L
iRAIL
DRIVER DRIVER
iRAIL iRAIL
DRIVER
WALL
iRAIL
3'-0"
3'-0"
3'-0"
DRIVER
36" TO FF
*WALL OR FLOOR WIRE FEED ENTRY REQUIRED AT RAILING TERMINAL POINT. TYP.
VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA
RAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE.
THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS' CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN.
REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.
I
1454 HALSEY WAY, CARROLLTON, TX 75007
Page 3.2 of 5
V
A
P: 972-353-8482 F: 972-353-0013
e: info@vivarailings.com www.vivarailings.com
L
iRAIL
iRAIL iRAIL
3'-0"
3'-0"
3'-0"
FINISH FLOOR FINISH FLOOR FINISH FLOOR
VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA
RAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE.
THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS' CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN.
REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.
I
1454 HALSEY WAY, CARROLLTON, TX 75007
Page 4.1 of 5
V
A
P: 972-353-8482 F: 972-353-0013
e: info@vivarailings.com www.vivarailings.com
L
iRAIL LINEAR
LIGHT INTENSITY X
COLOR (OUTPUT) POWER 0' 1' 2' 3' 4' 5'
Y
36"
42"
(Y)
MEDIUM 36" 44.1 30.3 15.6 7.7 4.1 2.3
3 W/ft
185 lumens/ft 42" 38.3 28.7 16.2 8.3 4.9 2.8
3000 K
HIGH 36" 59.5 41.2 20.8 10.3 5.5 3.0
5 W/ft
250 lumens/ft 42" 52.3 39.3 21.9 11.4 6.6 3.8
MEDIUM 36" 44.5 31.6 15.2 7.2 3.8 2.2
3 W/ft
185 lumens/ft 42" 38.7 29.6 16 8.3 4.5 2.7
4000 K
HIGH 36" 61.7 43.9 21.6 10.5 5.3 3.1
5 W/ft
250 lumens/ft 42" 54.3 42.2 22.6 12 6.4 3.7
5' 4' 3' 2' 1' 0 1' 2' 3' 4' 5'
(X)
VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA
RAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE.
THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS' CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN.
REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.
I
1454 HALSEY WAY, CARROLLTON, TX 75007
Page 4.2 of 5
V
A
P: 972-353-8482 F: 972-353-0013
e: info@vivarailings.com www.vivarailings.com
L
PS
h h: Illuminated Rail Height
PS: Pod Spacing
18" 18"
6'-0"
POD POD
> 2 ft.cl
> 1 ft.cl > 1 ft.cl > 2 ft.cl
> 4 ft.cl
> 4 ft.cl
1'-0"
1'-0"
> 8 ft.cl > 8 ft.cl
> 16 ft.cl
> 16 ft.cl
PLAN VIEW, h=36", PS=18", SYMMETRIC PODS PLAN VIEW, h=42", PS=18", SYMMETRIC PODS
FC: MAX=19.8, MIN=0.2, AVE.=6.1 FC: MAX=16.9, MIN=0.3, AVE.=6.0
18" 18"
> 2 ft.cl
> 1 ft.cl
> 1 ft.cl > 2 ft.cl
1'-0"
1'-0"
> 4 ft.cl
> 4 ft.cl
PLANDISPERSION
ISO FOOT CANDLE VIEW, h=36", PS=18",
PLAN VIEW, ASYMMETRIC
h (iRAIL HEIGHT)= 3'-0", ASYM. w/PODS
FC: MAX= 16.0, MIN= 0.1, AVE.= 5.1
1'-6" POD SPACING
POD PLANDISPERSION
ISO FOOT CANDLE VIEW, h=42", PS=18",
PLAN VIEW, ASYMMETRIC
h (iRAIL HEIGHT)= 3'-6", ASYM. w/PODS
FC: MAX= 13.5, MIN= 0.1, AVE.= 5.0
1'-6" POD SPACING
POD
FC: MAX=16.0, MIN=0.1, AVE.=5.1 FC: MAX=13.5, MIN=0.1, AVE.=5.0
POD
VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA
RAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE.
THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS' CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN.
REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.
I
1454 HALSEY WAY, CARROLLTON, TX 75007
Page 4.3 of 5
V
A
P: 972-353-8482 F: 972-353-0013
e: info@vivarailings.com www.vivarailings.com
L
PS
h h: Illuminated Rail Height
PS: Pod Spacing
24" 24"
6'-0"
POD POD
> 2 ft.cl
> 2 ft.cl
> 1 ft.cl > 1 ft.cl
1'-0"
1'-0"
> 4 ft.cl
> 4 ft.cl
PLAN VIEW, h=36", PS=24", SYMMETRIC PODS PLAN VIEW, h=42", PS=24", SYMMETRIC PODS
FC: MAX=14.9, MIN=0.1, AVE.=4.6 FC: MAX=12.7, MIN=0.2, AVE.=4.5
24" 24"
> 1 ft.cl
> 1 ft.cl
> 2 ft.cl
1'-0"
1'-0"
> 2 ft.cl
> 4 ft.cl
> 4 ft.cl
POD PLANDISPERSION
ISO FOOT CANDLE VIEW, h=36", PS=24",
PLAN VIEW, ASYMMETRIC
h (iRAIL HEIGHT)= 3'-0", ASYM. w/PODS
FC: MAX= 11.9, MIN= 0.1, AVE.= 3.8
2'-0" POD SPACING
POD POD PLANDISPERSION
ISO FOOT CANDLE VIEW, h=42", PS=24",
PLAN VIEW, ASYMMETRIC
h (iRAIL HEIGHT)= 3'-6", ASYM. w/PODS
FC: MAX= 10.1, MIN= 0.1, AVE.= 3.7
2'-0" POD SPACING
POD
FC: MAX=11.9, MIN=0.1, AVE.=3.8 FC: MAX=10.1, MIN=0.1, AVE.=3.7
POD
VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA
RAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE.
THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS' CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN.
REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.
I
1454 HALSEY WAY, CARROLLTON, TX 75007
Page 4.4 of 5
V
A
P: 972-353-8482 F: 972-353-0013
e: info@vivarailings.com www.vivarailings.com
L
PS
h h: Illuminated Rail Height
PS: Pod Spacing
36" 36"
6'-0"
POD POD
> 1 ft.cl
> 1 ft.cl > 2 ft.cl
> 2 ft.cl
1'-0"
1'-0"
> 4 ft.cl > 4 ft.cl
> 8 ft.cl
> 8 ft.cl
PLAN VIEW, h=36", PS=36", SYMMETRIC PODS PLAN VIEW, h=42", PS=36", SYMMETRIC PODS
FC: MAX=10.9, MIN=0.1, AVE.=3.0 FC: MAX=8.6, MIN=0.1, AVE.=3.0
36" 36"
> 1 ft.cl
> 1 ft.cl
1'-0"
1'-0"
> 2 ft.cl
> 2 ft.cl
> 8 ft.cl
PLANDISPERSION
ISO FOOT CANDLE VIEW, h=36", PS=36",
PLAN VIEW, ASYMMETRIC
h (iRAIL HEIGHT)= 3'-0", ASYM. w/PODS
FC: MAX= 8.9, MIN= 0.0, AVE.= 2.5
3'-0" POD SPACING
POD PLANDISPERSION
ISO FOOT CANDLE VIEW, h=42", PS=36",
PLAN VIEW, ASYMMETRIC
h (iRAIL HEIGHT)= 3'-6", ASYM. w/PODS
FC: MAX= 6.8, MIN= 0.1, AVE.= 2.5
3'-0" POD SPACING
POD
FC: MAX=8.9, MIN=0.0, AVE.=2.5 FC: MAX=6.8, MIN=0.1, AVE.=2.5
POD
VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA
RAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE.
THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS' CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN.
REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.
I
1454 HALSEY WAY, CARROLLTON, TX 75007
Page 5 of 5
V
A
P: 972-353-8482 F: 972-353-0013
e: info@vivarailings.com www.vivarailings.com
L
IR-LIN-1.5-304-30K-M-CL-0° IR-POD-1.5-304-30K-0°
Light color: Warm white 2700k 27K Available Applications: Ø1-1/2" Tube 1.5
Warm white 3000k 30K Ø2" Tube 2
Natural white 3500k 35K
Cool white 4000k 40K iRAIL Pod POD
VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA
RAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE.
THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS' CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN.
REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.
PRODUCT: IRAIL™
GRANDSCAPE BOARDWALK
THE COLONY, TX
Project Details:
Location: The Colony, TX
General Contractor: LMG Ventures
Architect: O'Brien Architects
Finish: #6 Satin Stainless Steel
Project Scope: 824 Linear Feet of Railings
Infill: Picket Panels & iRAIL LED Railing
Design & Installation Hours: 199
PRODUCT: IRAIL™
Project Details:
Location: Austin, TX
General Contractor: Flintco, LLC - Austin
Architect: Lawrence Group
Finish: #6 Satin Stainless Steel
LED Illuminated iRail
4000K High Output
Project Scope: 600 Linear Feet of Railings
Infill: 3/16” Stainless Steel Cable
Design & Installation Hours: 820
PRODUCT: IRAIL™
Project Details:
Location: Greensboro, NC
General Contractor: Blum Construction
Architect: CJMW Architecture, Inc.
Finish: Matte Black Powder Coat
LED Illuminated iRail
3000K High Output
Project Scope: 1,809 Linear Feet of Railings
Infill: 3/16” Stainless Steel Cable
Design & Installation Hours: 621
PRODUCT: IRAIL™
Project Details:
Location: Dallas, TX
General Contractor: Balfour Beatty Contractors
Architect: Mithun INC
FINISH: #6 Satin Stainless Steel
LED Illuminated iRAIL
Infill: 3/16" Cable
Design & Installation Hours: 750