You are on page 1of 4

MH 3069 HT 3~ 250

Semi-open multi-channel impellers with integral grinder cutter in single


volute casing for liquids containing solids and fibres.

Technical specification
Curves according to: Wastewater [100%],25 °C,0.997 kg/dm³,0.886 mm²/s
[m] Head
36
35
34
33
32
31
30
29
28
27
26
25
24
23 Eff.
22 37.7%
21
20
19
18
17 34.5%
16 34.1%
15
14 32.4%
13 32.7%
12
11
10
9
8
7
6
5 250 160mm
4
3 258 127mm
2
1
0
0 40 80 120 160 200 240 [l/min]
Curve: ISO 9906

Configuration
Motor number Installation type
M3069.170 13-10-2BB-W H - Semi permanent, Wet
2.4KW
Impeller diameter Discharge diameter
160 mm 40 m m

Pump information Materials


Impeller diameter Impeller
160 mm Grey cast iron

Discharge diameter Stator housing material


40 mm Grey cast iron

Inlet diameter
40 mm

Maximum operating speed


2740 1/min

Number of blades
5

Max. fluid temperature


40 °C

Project Xylect-20275283 Created by Gaurav Mishra


Block 0 Created on 3/13/2023 Last update 3/13/2023

Program version Data version User group(s)


67.0 - 02/02/2023 (Build 105) 06/03/2023 15:51 Xylem: India - INT
MH 3069 HT 3~ 250
Technical specification
Motor - General
Motor number Phases Rated speed Rated power
M3069.170 13-10-2BB-W 3~ 2740 1/min 2.4 kW
2.4KW
Approval Number of poles Rated current Stator variant
No 2 4.7 A 3

Frequency Rated voltage Insulation class Type of Duty


50 Hz 415 V F S1
Version code
170

Motor - Technical
Power factor - 1/1 Load Motor efficiency - 1/1 Load Total moment of inertia Starts per hour max.
0.90 78.6 % 0.0042 kg m² 15

Power factor - 3/4 Load Motor efficiency - 3/4 Load Starting current, direct starting
0.86 82.8 % 23 A

Power factor - 1/2 Load Motor efficiency - 1/2 Load Starting current, star-delta
0.78 85.2 % 7.66 A

Project Xylect-20275283 Created by Gaurav Mishra


Block 0 Created on 3/13/2023 Last update 3/13/2023

Program version Data version User group(s)


67.0 - 02/02/2023 (Build 105) 06/03/2023 15:51 Xylem: India - INT
MH 3069 HT 3~ 250
Performance curve
Duty point
Flow Head
153 l/min 26.1 m

Curves according to: Wastewater [100%],25 °C,0.997 kg/dm³,0.886 mm²/s


[m] Head
37.0
36.5
36.0
35.5
35.0
34.5
34.0
33.5
33.0
32.5
32.0
31.5
31.0
30.5
30.0
29.5
29.0
28.5
28.0
27.5
27.0
26.5
26.0 26.1 m
25.5
25.0
24.5
24.0
23.5
23.0 Eff.
22.5 37.7%
22.0
21.5
21.0
20.5
20.0
19.5
19.0
18.5
18.0
17.5 34.5%
17.0
16.5
16.0 34.1%
15.5
15.0
14.5
14.0 32.4%
13.5
13.0 32.7%
12.5
12.0
11.5
11.0
10.5
10.0
9.5
9.0
8.5
8.0
7.5
7.0
6.5
6.0
5.5
5.0
4.5 250 160mm
4.0
3.5 258 127mm
3.0
2.5
2.0
1.5
1.0
0.5 153 l/min
0.0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 [l/min]
Curve: ISO 9906
Project Xylect-20275283 Created by Gaurav Mishra
Block 0 Created on 3/13/2023 Last update 3/13/2023

Program version Data version User group(s)


67.0 - 02/02/2023 (Build 105) 06/03/2023 15:51 Xylem: India - INT
MH 3069 HT 3~ 250
Dimensional drawing

188
150 124

Threaded, internal
ISO228/1 G1 1/2
321
96

100
119

Ø315

Weight total
Discharge
kg 47
S cale Date
MH 3069 HT outlet
Pump outlet
ISO-G 1-1/2

DN 40 1:5 220927
Pump inlet Drawing number Revision
Suction
inlet
8000400 6

Project Xylect-20275283 Created by Gaurav Mishra


Block 0 Created on 3/13/2023 Last update 3/13/2023

Program version Data version User group(s)


67.0 - 02/02/2023 (Build 105) 06/03/2023 15:51 Xylem: India - INT

You might also like