Technical Data Sheet ap Werk Sel
YD-R2433/1
ation: 2019-09-25
Package:
200kg/drum (galvanized iron bucket).
Storage: _
Containers should be stored tightly sealed in a dry place and be kept away from foods, animal
feeds, acids and oxidant. The temperature recommended for storage is 10~25°G;
Shelf life under appropriate storage is 6 months.
Waste Disposal:
Please refer to the ‘material safety data sheet” or follow local laws and regulations.
HANDLING PRECAUTIONS
. YD-R2433/1 is a polyol-based product containing, among other substances, a small
percentage of tertiary aliphatic amines.
. Due to its alkaline nature, YD-R2433/1 can cause slight to moderate irritation on direct
contact with the skin, eyes and mucous membranes, particularly if contact is prolonged.
. Safety goggles and impermeable protective gloves should always be worn if there is a risk of
direct exposure when handling this product.
. Splashes in the eyes should be removed immediately by careful flushing with copious
amounis of water. If irritation persists, medical attention should be obtained.
. Splashes on the skin should be wiped off immediately, after which the contaminated areas
should be thoroughly washed with soap and water. A good barrier cream should then be
applied.
. Contaminated clothing should be removed immediately to prevent further skin contact and
thoroughly cleaned before reuse. The product should be kept away from food, drink and
tobacco.
- Further technical information relating to safety can be found in the Safety Data Sheet.Technical Data Sheet
ae URES
YD-R2433/1/1
Eaton: 2019-08-25
Application:
YD-R2433/1 /1 is Cyclopentane blown system, a mixture of polyols, silicone,
flame retardants etc. Reaction with blowing agent and isocyanate can get ri
catalyst and
id polyurethane
foam, particularly used for the discontinuous insulation panels. pallets. The thickness of the
foam layer range can be from 40 to 200mm depending on different requirements.
Processing Data:
YD-R2433/1 system is recommended to be processed by high pressure machine. It is
essential to make the equipment deliver consistently accurate ratio of polyol and isocyanate
for the high quality of foam.
YD-R2433/1 100
Isocyanate 125 -130
Mold temperature 40-45°C
Component temperature 23°C
Cup test: cee
tem Data__Unit__ Standards
Material temperature 23 c
Stirring time 10 sec.
Cream time 2042 sec. _ Internal test standards
Gel time 140£5 sec.
Free rise cup density 291 kgim®
Remarks: stirring speed 1800rpm, diameter of stirring head 60mm, cup volume 500mL.