ii.

Shear

Slab Bridges designed for moments in conformance with AASHTO may be considered
satisfactory in resisting shear force

iii. Distribution reinforcement (transverse reinforcement)


As percentage of main reinforcements

a. Interior strip:

Use ⁄
b. edge strip:

Use ⁄ ,

For ease of placement Use ⁄ across the entire width of the bridge

iv. Shrinkage and temperature reinforcement


in each direction both faces

a. Interior strip


Top layer

Use ⁄