Professional Documents
Culture Documents
100
300mm Polystyrene EPS 300 ( λ = 0.043W/m.K.)
500
Ground Level
30mm - 50mm of 6mm grade 30mm - 50mm of 6mm grade 300mm wide Polystyrene EPS 300
dust free stone dust free stone (λ = 0.035W/m.K.)
Rev. Description Date
Radonbarrier RAC800 Molarflex
Radonbarrier RAC800 Molarflex 515 extended 1m past foundation Floor Areas
20mm Sand blinding, T3 Blind to SR 21 Annex E Ground Floor Area = 122.4m² (1317ft²)
extended 1m past foundation
150mm - 300mm (subject to site inspection and testing) First Floor Area = 88.4m² (951ft²)
20mm Sand blinding, T3 Blind to SR 21 Annex E 150mm - 300mm (subject to site inspection and testing)
well compacted 18-35mm angular stone, (Not Clause 804) well compacted 18-35mm angular stone (Not Clause 804) Total Floor Area = 211.0m² (2268ft²)
100mm Preimeter Land Drain
T.2 Permeable: Gas Permeable layer (Radon) to SR 21 Annex T.2 Permeable: Gas Permeable layer (Radon) to SR 21 Annex
150x90x10UA Support fixed to Blockwork which is to be chemically anchored Project Name and Address Job No.
using Hilti HIT injectable adhesive anchor to specialist's design and H. Dunne & S. Supple B 522
manufacturers instructions. Angle to be made water tight with Pro clima
Oldgraigue, Maynooth, Sheet No. Rev.
Extoseal Encors available from Ecological Building Systems
Co. Meath Sheet 7 of 9 -
Drawing Title
Date Drawn By
21st March 2020 CS
Scale Checked By
1:20 on A1 Sheet CS
This drawing is COPYRIGHT ©. It may not be used, copied or reproduced in any form or for any purpose
without express written permission. This drawing is for private and confidential use of the purchaser and
should not be reproduced in whole or part or relied upon by third parties for any use without written authority.