You are on page 1of 2

Siemens PLM Software

NX FE Model Updating
Improve analysis model accuracy

Benefits Summary Core functionality


• Improves accuracy and NX™ Finite Element (FE) Updating is an NX FE Model Updating provides the follow-
increases confidence in advanced correlation tool designed to auto- ing core functionality.
your FE models matically update FE models to match real
Interactive design variable definition
life test data as closely as possible. NX FE
• Saves time as changes You can choose from a large number of
Model Updating is fully integrated with NX
made in the working FE design variables of different types, includ-
Advanced Simulation, making the updating
model automatically ing material properties (isotropic, ortho-
process easier and more productive than
propagate to the correlation tropic, anisotropic) and element properties
ever before. It is an add-on to NX FE Model
and model updating that affect system mass and stiffness.
Correlation, enabling you to leverage the
calculations Laminate ply thickness and angle can be
power and ease of use of the NX environ-
used as design variables and may be
• Avoids rework as model ment, including all correlation capabilities.
defined from the ply definition in the NX
update automatically
Engineers often rely on previous experi- Laminate Composites module.
propagates results back to
ence and best practices for modeling
the FE model Dedicated DESOPT 200 –
components, physical properties and mate-
Model Update solution
• Lowers training costs and rials of a complex nature. Validation proce-
Support is provided for static (Guyan) or
increases productivity by dures, which typically include finite
modal reduction, design variables and
enabling you to perform element model correlation, help to confirm
A-Set or U-Set DOF to generate OP2 output
model updating within a that the right assumptions have been made
including reduced model matrices and
familiar environment that and sound modeling methodologies have
sensitivities. No manual editing of Nastran
your engineers already use been applied.
input decks is required. You do not need to
for analysis
Once engineers establish sufficient fidelity separately purchase a DMAP or SOL 200
of a model, NX FE Model Updating provides license.
them with the tools to further improve the
Design variable sensitivities
model by finding the best values for
You can compute and plot the sensitivity
selected parameters to match the test
matrix for all design variables and targets.
results (or another baseline analysis result)
even more closely.

www.siemens.com/nx
NX

NX FE Model Updating

Embedded eigenvalue solver


NX FE Model Updating rarely requires the
normal mode solution to be re-solved for
the full FE model. Instead, it performs a
sensitivity calculation at every iteration
according to new eigenvalue solutions
allowing larger (nonlinear) design variable
changes by piece-wise linear updating of
the sensitivities. This approach achieves
accurate updating results in only a few
iterations.
Multiple optimization algorithms
Side-by-side mode shape animation. Side-by-side mode shapes test/
You have a choice of least squares, steep-
analysis and MAC after model update.
est descent, and genetic optimization
algorithms.
Filtering of design variables
You can effectively manage a large number Accommodation of FEM changes
of design variables during the optimization NX FE Model Updating handles any
process using filtering based on user- changes you make to the underlying FEM
defined criteria or automatic criteria. (model geometry, meshing, material or
physical properties). After re-solving, NX
Frequency and mode shape targets
automatically re-performs spatial correla-
You can choose the frequencies and/or
tion (node matching); the entire updating
mode shapes that you want to include in
configuration is retained so you can imme-
the optimization target function with any
diately continue the updating process.
combination of weights. This capability
includes support for mode shape correla- Complete FEM and SIM update capability
tion based on modal assurance criteria You can update either the design variable
(MAC) or cross-orthogonality. modeling objects or the FE model. After
Contact
updating the FEM, all other solutions
Siemens PLM Software
contained in the SIM (e.g., structural static, Americas +1 314 264 8499
dynamic) are immediately ready to be Europe +44 (0) 1276 413200
solved using the updated parameters. Asia-Pacific +852 2230 3308

Ability to leverage all NX FE Model www.siemens.com/plm


Correlation’s capabilities
NX FE Model Updating leverages imported © 2015 Siemens Product Lifecycle
test data, geometry mapping, sensors and Management Software Inc. Siemens
degree-of-freedom sets. It also provides and the Siemens logo are registered
access to correlation metrics (e.g., MAC, trademarks of Siemens AG. D-Cubed,
Femap, Fibersim, Geolus, GO PLM,
COMAC) and side-by-side mode shape
I-deas, JT, NX, Parasolid, Solid Edge,
animation, just as in the correlation solu- Syncrofit, Teamcenter and Tecnomatix
tion process. are trademarks or registered trade-
Optimization with detailed error reporting. marks of Siemens Product Lifecycle
Management Software Inc. or its
subsidiaries in the United States and in
other countries. Nastran is a regis-
tered trademark of the National
Aeronautics and Space Administration.
All other logos, trademarks, registered
trademarks or service marks belong to
their respective holders.
21241-Y1 1/15 C