You are on page 1of 4

ESD Control Checksheet

Date
Subject:-

Auditor Project Location :-

S. No. Verification points

Where ESD Protective flooring is using for personnel grounding , are floor grounding devices or
1
conductive footwear properly worn or not ?

2 Are personnel wearing grounded wrist straps at the esd protective workstations.

3 Do ESD wrist straps and every metal objects foot grounders fit correctly?

Resistance to ground which in contact with ESD objects (Work Bench) are in between (10^6 Ω
4
<R< 10^9 Ω)

5 ESD Protective garments are correctly worn or not ?

6 Are non essential personal items kept out of ESD controlled areas ?

7 Are personnel working in the ESD Controlled area are ESD certified or not?

All Non esd objects must be kept at distance of 30cm from electronic materials.
8

9 All Electronic Material kept online at workbench must be placed inside esd bin/poly.

10 All ESD related material and process must be performed on shopfloor inside EPA Area.

Work Bench in contact with Electronic items or closer them 15cm must have electrostatic
11
volatge V<50 volts.

Relative humidity & Temperature for workshop floor must rely in between (16 °C ~ 24 °C) &
12
(45% to 75%)
All ESD material during movement must have grounding and resitance to ground must lie
12 below R< 10^6 Ω

Auditor Signature :-
cksheet Qarmatek

Version 00

Yes No Remarks

ding , are floor grounding devices or

tective workstations.

fit correctly?

rk Bench) are in between (10^6 Ω

areas ?

ertified or not?

electronic materials.

aced inside esd bin/poly.

shopfloor inside EPA Area.

15cm must have electrostatic

ely in between (16 °C ~ 24 °C) &


d resitance to ground must lie

Verifier :-