059-2. txt *RRRRER® SYNPOL-D PARAMETERS 1. . 613 *####### Name of vesse owner Diesel-No. Maker Name Building yard Yard-No. Order-No. Date society Comments. GENSET NO.2 INCAT TASMANIA 059 MA131 Time Delay pe 0,6 Opaetats rs MA131 Short Circuit - IN/Ki x2: - IN/Ki x3: ~ IN/Ki x4: IN/K: (MA135 Broken Wire Alarm ~ MA135 Broken Wire Outp. (MA135 Pick Up Selection SYNPOL D SERIAL NUMBER : 1434 1.ACTUAL TIME - [Hours] : Oh : - [MINUTES] : Om 3. ACTUAL DATE [YEAR] : Oy 4 - [WonTH]: 1 5. - [DAY]: 1 6.NUMBER OF DIESEL: > fp 7.COUNTER - UNIT 1:MWh / O:kwh: 0 8. - k/Mwh SET 0 9. - temp. k/Mwh SET QO 10. - k/Mvar SET 0 11. - WORKING HOURS Oh 12. ~ START COUNTER : o 13.GENERATOR RATED - CURRENT : 417A 14. - VOLTAGE : 415 Vv 15. - ACT.POWER: 240kW 16. ~ FREQUENCY: —_50HZ 17. TRANSFORMER RATIO CURRENT : 500 18. ~ RATIO VOLTAGE [*10]: 10 19.TERMINAL BOARD: 100/450v_: 450 v 20-MAINS PROTECTION VIA FUN.INP! 0 Page 1 059-2. txt -limit for rapid phase jump: 20dg -current inc.after phasejmp: 20 % -limit for overfrequency 101 % 24. -delaytime f.overfrequency : 100ms : -limit for underfrequency : 99 % 6. -delaytime f.underfrequency: 100ms imit for overvoltage : 110 elaytine for overvoltage : 100ns . ~limit for undervoltage : 10 % -delaytime for undervoltage: 100ms 31. [NOT IN USE] 0 32. [NOT IN USE] 33. [NOT IN USE] 0 34. [NOT IN USE] 5 0 35.BATT.SUPPLY MIN. LIMIT 0 36.ANAL.OUTPUT1 POWER 20mA/10V = 117 % 37. -OUTPUT2 current 20mA = 110 % 38. -OUTPUT3 function value : ae 39. -OUTPUT3 full scale = 110 % 40. -OUTPUT4 function value : 2 Al. -OUTPUT4 full scale = 110 % 42.SYNCHR.speed adj.break time : Aas 43. -speed adj.pulse time : 30s 44. ~speed push after 10s : 50ms 45. -synchr. window [deg] : 10dg 46. -max.diff.freq. [mHz] : 150 47. 60 88.CONSUMER1 REQUEST ON FUN.INP: 0. 89.LOADREQUEST OF CONSUMER [18]: Okw 90.CONSUMER2 REQUEST ON FUN. INP: 0 91.LOADREQUEST OF CONSUMER 91) 2 92. NOMINAL LOAD OF -DIESEL -DIESEL ba. DIESEL DIESEL 96. NOMINAL LOAD OF -DIESEL -DIESEL 38. -DIESEL 99. -DIESEL NO. -100.SHORT CIRCUIT fe T: 500ms } 102.SHORT CIRCUIT&REV.L: T: 100ms 104. PREL.SHRT CIRCUIT L: T: 200ms 106-OVERCURRENT 1.ST. L: Tze BES 108 -OVERCURRENT 2.ST. Li THs 3.8 110: OVERCURRENT 3.ST. L: T: 120s 112.N.C.CURRENT 1.ST. L ice We tsi 114.N.C CURRENT 2:ST. L ae BIDes: 116.N.C.CURRENT 3.ST. L ile Bes: 118.REV. ACTIV POWER Serer ans S 120.HIGH ACTIV POWER ey els 122.OVERVOLTAGE 1.ST. ot 2s 124.0VERVOLTAGE 2.5: T 2s 126. UNDERVOLTAGE oT Sus 128. UNDERVOLTAGE Te. 53S 130. OVERFREQEN. Te. 425 132. OVERFREQEN. F Ts! Sez ss 134: UNDERFREQEN. 1.ST. T: ans 136.UNDERFREQEN. 2.ST. Te 2s 138. ASYMMET. CURRENT Tr 10s 140. ASYMMET . VOLTAGE NTE 105 142.DIFF.PROTEC.MB OP % 7: 500ms 144.DIFF.PROTEC.MB CL 5]% T: 500ms 146.EARTH FAULT MB OP 51% T: 2s 148.EARTH FAULT MB CL 50]%T: 10s 150.GROUND 0' CURRENT 01% T: Oms 152.GENVOLT.OPERATION 85)% T: 1s: 154.C.T. WIRE BROKEN 15]%T: 10s 156.EXCITATION FAULT 01% T: 0 5 158 NEGATIVE SEQUENCE 00]% T: 160.FUN. 4 A 7:608/ aay “Op 0/ 0/ a Page 3 wm bess Hs only 059-2. txt « 5 A 8:114/120/134/518/ O/ 0/ 172.FUN. on AQ: g/t see 0/ 0/ oe] 190.FUN.10 a2! 196.FUN.11 2 202. FUN 0/ Of Of Of O/ 208.FUN.13 A29:126/ 0/ 0/ O/ O0/ 0/ 214. FUN.14 0/ 0/ 0/ Of O/ 220. FUN. 15 O/ Of 0/ O/ O/ 226.FUN.16 Of Of Of Of OF 232.FUN.17 O/ Of OF Of Of 238. FUN. 18 O/ Of 0/ O/ 0/ 260. SYNPOL : GENSET NO.2 276. : PORT LOWER 292. DIESEL : LOW OTL PRESSURE 308. : HIGH WATER TEMP. 324. EMERGENCY STOP 340. CO2_ SHUTDOWN 356. OVERVOLTS 372. 2 LOW WATER FLOW 388. : DIESEL ALARM 7 404. DIESEL : C.B. SUPERVISION 420. : INPUT WIREFAULT 436. : OUTPUT WIREFAULT 452. - ALARM11: OVERSPEED 468. = ALARMI12: TACHO FAILURE 484.DIESEL CONTROL OFF/ON: 1 485.RPM-SIGNAL ANAL.INPUT OFF/ON: _ 0 486. -FULLSCALE FOR ANAL.INPUT: 140 % 487. -SIGNAL PICKUP] — OFF/ON 1 488. -PICKUP1 NUMBER OF REVOL.: 113 489. | -SIGNAL_PICKUP2 OFF/ON 0 490. | -PICKUP2 NUMBER OF REVOL.: 10 491. -MAX.SPEED DIFFERENCE 120 % 492.RPM VALUES- IGNITION SPEED 20 % 493. - NOMINAL SPEED 1500rm 494. - RUNNING UP SPEED: 90 % 495. ~ OVERSPEED : 115 % 496.STARTPHASE NO.OF START ATTEM. 3 497. -O:PREGLOW /1:BOOSTERVALVE: 0 498. -PREGLOW / PRELUB.TIME : oO 499. -SHORTEN PREGLOW V.FUN. INP. oO 500. -START TIME 5 501. -START AT [0]RPM OFF/ON: - : 0 502. -BREAK TIME 10 s 503. -RUNNING UP SUPERVISION T. 7s 504. -READY TO TAKE LOAD TIME 5s 505. -SYNCHR. SUPERVISION TIME : 120 s 506. -RELEASE ALARMBLOCKING T. 7s 507. -START NEXT AFTER 1.ATTEM: 0 508. -PROTECTED START IN MANUAL: 0 509.PRELUBRICATING - PULSETIME : 20 s 510. ~ BREAKTIME : 120 s 511.STOPPHASE ALARM2 DELAY TIME : 60 § Page 4 059-2. txt 512. - COOLING DOWN TIME 513. | - RUNNING DOWN TIME 514. - STOP DELAY FIXED TIME 515. - O:STOPVALVE/1: FUELVALV! 516. | - BREAKER OFF(A20) TO AL. 517.MODE FOR M.B.TRIP. IN AUTOM 518.BLACKOUT: -START NEXT/ALL D 519. - DELAYTIME FOR BLACKOUT 520. - STOP AFTER BLACKOUT OFF/ON 521. - DELAYTIME F.BLACKOUT STOP: 522. — BLACKOUT VIA MAINS MONITOR 523. FUNCTION OUTPUT SPEED > = VOLTAGE > oe - POWER > 526. = CURRENT > 527. - REL.TOT.POWER > 528. - POWERFACTOR CAP.< : 329- - POWERFACTOR IND.< : -_REVERSE POWER > 330" REACTIVE POWER IND 532.ALARM ACKNOWLEDGE ON FUN. INP: 533. ALARM1-LOGIC F 534. PRIORITY GROUP [1..4]: 535. ALARM DELAY TIME : 536. -ALARM BLOCKING OFF/ON: oe ALARM2 -LOGIC : 538. PRIORITY GROUP [1..4]: 539. “ALARM DELAY TIME : 540. ~ALARM BLOCKING OFF/OI 541. ALARM3-LOGIC 542. -PRIORITY GROUP [1..4]: fo ALARM DELAY TIME : 544 ~ALARM BLOCKING OFF/ON: 43. TALARM4-LOGIC ~PRIORITY GROUP [1..4] Bay. ~ALARM DELAY TIME : 548. ~ALARM BLOCKING OFF/ON: 343. ALARMS-LOGIC 7 is -PRIORITY GROUP [1..4]: Bu. ~ALARM DELAY TIME : ~ALARM BLOCKING OFF/ON: 333. TALARM6-LOGIC ' ~PRIORITY GROUP [1..4]: 335. ~ALARM DELAY TIME : ALARM BLOCKING OFF/ON: ay" ALARM7-LOGIC : 558. -PRIORITY GROUP [1..4] 959. ~ALARM DELAY TIME -ALARM BLOCKING OFF/ON: Sel: ALARMB-LOGIC 3 62. PRIORITY GROUP [1.. 363. ~ALARM DELAY TIME : 564. ~ALARM BLOCKING OFF/ON 365 -ALARMQ-PRIORITY GROUP [1..4]: ALARM DELAY TIME f Page 5 12 louKe 0 50 2 oS co00 2 s BE2R BC 2H DLD DIL w oo SRONHOONS OHM UHOCOHOC OHO OCOHCOOHOHOHOS wou w 059-2. txt 567. ~ALARM BLOCKING OFF/ON: 568.ALARMLO-PRIORITY GROUP[1. . 4. 569. ALARM DELAY TIME 570. -ALARM BLOCKING OFF/O! 571.ALARML1-PRIORITY GROUP[1. .4. 572. “ALARM DELAY TIME 573. ~ALARM BLOCKING OFF/O! 574.ALARM12-PRIORITY GROUP[1. . 4. 575. “ALARM DELAY TIME 576. -ALARM BLOCKING OFF/O! 577.SET EMERGENCY DIESEL FUN. IN 578.CAN BAD DATA FLOW MESSAGE N 579.SEPARATE LOADSH. & FREQ.CTR' 580. FUNCTION FOR ANALOG.OUTPUT 581.MAINS PARAL.OPERATION OFF/Ot 582.ANAL.INPUT2 [CMA135] ADJUSTM 583.ANAL.INPUT3 [CMA137] ADJUSTM 584.SACE LOW VOLTAGE COIL FREQ2 585.POWERFACTOR CAP.< SPECIAL 586.POWERFACTOR IND.< SPECIAL 587.M.B. TRIPPING BY OVERVOLTAGE 588.ASYMMETRIC CONTROLLER OFF/O! 589. -CONTROL.ON-SWITCH FUN. IN 590: -MIN. LOAD TO SWITCH OVER 591. -TIME DELAY F.SWITCH OVER 592.VOLTAGE REGULATOR -SET POIN 593. -BREAKTIME 594. -PULSETIME 595. -SENSITIVITY OF CONTROLLE! 596.POWERFACTOR CTRL.- BREAKTIMI $97. -PULSETIME 598. -SENSITIVITY OF CONTROLLE! 599. LCD-CONTRAST AUTO-ADJ .OFF/O! 600.RS422/485 - COM PORT ADDRES: 601. = PROTOCOL NO. 602. > BAUDRATE [1-3] 603.ALARM SUPERVISION LOCAL OFF 604.SPECIAL APPLICATION KEY 605.REM.CONTROL IN MANUAL MODE 606.ANAL.FILTER FOR CMA124[1-99] : 607.ALARM2-STOP WITH COOLING DOWN 608.DISABLE BLACKOUT-INTERLOCK : 609.ALARM SETTING OF Al0 & A26_: 610.DELAYTIME FOR SPECTAL EVENT! 611.SPECIAL APPLICATION KEY No. 612. [NOT IN USE] 613. [NOT IN USE] Wiehieiicick FUNCTION INPUT PARAMETERS *####### 20.MAINS PROTECTION VIA FUN. INP: 58. ~ ASYM.ON-SWITCH FUN. INP: 64. FREQ.CTRL.OFF-SWITCH FUN. INP: 70.POWERMAN. OFF-SWITCH FUN. INP: 82.START ONE DIESEL ON FUN.INP : 84. BLOCKING OF STOP ON FUN.INP : Page 6 » w CooRCONHORHOSRO 2 Be $ So 208s BocournrpnaanSuScocccoe 1 locoKoCe Boooc] RUB an

You might also like