An extensive range of 48, 72, 96 and 144mm DIN style panel meters offering
measurement of all electrical and electronic parameters. Meters are shock resistant
and vibration proof and supplied with terminal covers. A selection of slide in dials
and customised options are available.
Movements
In Crompton Instruments’ world-patented ‘Hi-Q’ taut band suspension, all the
delicate parts of the traditional instruments are eliminated. There are no pivots, no
jewel bearings, no hair-springs and no air damping vane. Instead, a tough platinum
ribbon suspends the moving element between front and rear tension springs.
Specially contoured pads are fitted to the ends of the spindle, and the working gap at
each end is filled with a high quality silicon fluid. The pads, together with the fluid
reservoir, form a system which acts as a resilient built-in shock absorber. This
provides both rotational and longitudinal damping as the moving element floats on
oil with no bearing friction and is effectively cushioned against shock and vibration.
360° Synchroscopes and power factor meters have robust pivot and jewel bearings
Features with oil damping.
An extensive range of specialist
measuring meters in 4 case sizes Dials, Scales and Pointers
Standard dials are matt white with black printed scales and bar knife-edge pointers.
Shock resistant taut band suspension
Black dials with white or yellow scales and pointers are also available.
Vibration-proof Hi-Q damping Interchangeable slide in dials are used on models 242, 243 and 244 90° moving iron,
Slide in dials for 90°current, voltage and moving coil and frequency meters.
frequency on models 242, 243 and 244 General options include red supplementary pointers, red indexes (quadrant scales),
red, green or blue lines, bands or segments, finely spaced divisions, multi-scales,
Terminal covers supplied as standard special scales and captions to customer' requirements.
Benefits Illumination
Low cost Internal illumination is available in the following models:
Local indication • 244 and 246 shortscale moving coil and moving iron vane.
• 243, 244 and 246 longscale moving coil and moving iron vane.
Ease of installation
Through dial (Translucent) illumination on 244 and 246 models.
Minimal training Edge illumination on 243, 244 and 246 models.
Low maintenance Replaceable 6, 12 or 24V lamps are used on all models except 243 longscale meters,
Customised options and features where the lamps are internal.
Applications Specification
Performance BSEN60051
Switchgear
Measuring Ranges DIN 43701
Distribution systems Accuracy Overload BSEN60051
Generator sets Dimensions DIN 43700
Scale Marking Generally DIN43802
Control panels
Magnetic Influence BSEN60051
Energy management Safety IEC414
Building management Terminals Clamp strap M4 up to 25A. Clamp strap M8 over 25A
Humidity Range Up to 95% RH (non condensing)
Utility power monitoring
Test Voltage @50Hz 2kV RMS for 1 minute
Process control Overload AC Current x 1.2 continuous x 10 for 5 seconds
Motor control Overload AC Voltage x 1.2 continuous x 2 for 5 seconds
Frequency See main pages for other instruments
Approvals Damping Time Less than 3 seconds is standard. More heavily damped
movements are available on request.
LRS and BV Approvals.
Standard Calibration 23°C
Operating Temperature -20°C to +60°C
Enclosure Code IP54 as standard (to BSEN60529). IP55 consult factory
Terminals IP20B with terminal cover or terminal
boots fitted
Case Grade UL94V0
Base Grade UL94V1
8
240 Series DIN Panel Meters
Dimensions
Model 242 243 244 246
Bezel ‘A’ 48 x 48 72 x 72 96 x 96 144 x 144
Panel cut-out ‘B’ 45 x 45 68 x 68 92 x 92 138 x 138
Scale Length: 90° 42 65 94 145
Scale Length: 240° 72 112 150 230
Maximum overall depth ‘C’:
Ammeters and Voltmeters A.C. & D.C.* 64 64 64 60
Ammeters and Voltmeters with switch* – – 64 –
Dual Meters* – – 64 –
C Elapsed Time Meter/Hours Run* 64 64 64 –
Maximum Demand Indicator* – 64 64 60
Combined MDI & MI Indicator* – – 64 60
Maximum Demand Indicator with relay* – – 90 –
Frequency Meter 90°* 64 64 64 60
A Frequency Meter 240°* § § 120 125
Phase Angle, Power Factor Meter 90°* § § 107 §
240°* § § 107 §
M.C. Indicator with separate transducer* 64 64 64 60
Dynamometer 360° Synchroscope* – – 120 125
Dynamometer 360° Power Factor Meter* – – 120 –
A Phase Sequence Indicator* – 64 64 –
Position Indicator* § § 120 125
Speed Indicator* 64 64 64 60
Temperature Indicators* – – 120 125
Quadra Meters* – – 64 –
Panel cut-out Impulse Counters* 64 64 64 –
Wattmeter, Varmeter 90° § § 107 125
Maximum Panel B
Wattmeter, Varmeter 240° § § 107 125
thickness 10mm Model 244-21Y & 244-21Z – – 142 –
LED Synchroscope & Synchro Check Relay – – 80 –
LED 360° Synchroscope – – 80 –
§ Indicator Only
B * If separate terminal cover is used add 20 mm to dimension C
– Not available
9
240 Series DIN Panel Meters
10
240 Series DIN Panel Meters
Specification
Accuracy: Class 3
Options: 5A for use with separate C.T.
5/5A saturating C.T.
1/5A saturating C.T.
Burden at 50 Hz: MDI - 2.5VA, C.T. - 2VA
Overload withstand: Standard: 5 x FL for 5 seconds, 10 x FL for 1 second
Connections With Saturating C.T.: 10 x FL for 3 seconds,
20 x FL for 1 second
Frequency: 50/60Hz
Product Codes
Bezel Size mm 72 96 144
Scale length mm* 65 94 145
Product Codes
8 Minute Time Lag
Without limiting C.T. for use with 5A C.T. 243-16B 244-16B –
With self-contained 5/5A limiting C.T. – 244-16R –
15 Minute Time Lag
Without limiting C.T. for use with 5A C.T. 243-16A 244-16A 246-16A
With self-contained 5/5A limiting C.T. – 244-16E –
20 Minute Time Lag
Without limiting C.T. for use with 5A C.T. 243-16J 244-16J 246-16J
With self-contained 5/5A limiting C.T. – 244-16K –
* Scaled 0/100/120% of C.T. primary value.
Specification
Accuracy: Moving Iron Ammeter: Class 1.5, MDI: Class 3
Burden at 50Hz: MI - 0.5VA, MDI - 2.5VA, Saturating C.T. - 2VA
Product Codes
Bezel Size mm 72 96 144
Scale length mm* 65 94 145
Product Codes
8 Minute Time Lag
Without limiting C.T. for use with 5A C.T. 3VA – 244-16Q –
With self-contained 5/5A limiting C.T. 5VA – 244-16T –
15 Minute Time Lag
Without limiting C.T. for use with 5A C.T. 3VA – 244-16C 246-16C
With self-contained 5/5A limiting C.T. 5VA – 244-16F 246-16F
20 Minute Time Lag
Without limiting C.T. for use with 5A C.T. 3VA – 244-16H –
With self-contained 5/5A limiting C.T. 5VA – 244-16L –
* Scaled 0/100/120% of C.T. primary value.
11
240 Series DIN Panel Meters
Frequency Meters
These Frequency meters use an integral electronic converter and a moving coil
indicator. This meter is easy to read with an accuracy Class 0.5.
Specification
Accuracy: Class 0.5
Ratings: 100V-125V A.C
200V-250V A.C.
380V-440V A.C.*
500V A.C.*
*For voltages above 380V use 242-013 with a 253-THZ,
in place of 242-41S
Models available for use with V.T.s
Frequency 0.5%: 45/55Hz,
55/65Hz,
Connections 45/65Hz,
360/440Hz
Other scalings available on request
Burden: 4VA Maximum
Product Code
Bezel Size mm 48 48 72 72 96 96 144 144
Scale length mm 42 72 65 112 94 145
Product Code 242-41S 242-053 243-41S 243-053 244-41S 244-41L 246-41S 246-41L
+253-THZ +253-THZ
Specification
Accuracy: Class 0.5
Ratings: 100V-125V A.C
200V-250V A.C.
380V-440V A.C.
500V A.C.
Models available for use with V.T.s
Frequency 0.5%: 45/55Hz,
55/65Hz,
45/65Hz,
Connections 360/440Hz
Burden: 4VA Maximum
Product Code
Bezel Size mm 96
Scale length mm 65
Product Code 244-41D
12
240 Series DIN Panel Meters
Specification
Accuracy: 1.5% ES
Ratings: Ammeter: 250µA to 10A A.C.
Voltmeter: 15 to 600V direct connected
Frequency: 50/60Hz (single frequencies 25Hz to 3kHz on request)
Product Codes
Bezel Size mm 96
Scale length mm 65
Product Codes
Ammeters 244-80F
Voltmeters 244-80L
Dual A.C. Ammeter Dual A.C. Voltmeter
Direct Connected
13
240 Series DIN Panel Meters
14
240 Series DIN Panel Meters
Specification
Display: 99999.99
Voltage: 100-125V A.C.
200-250V A.C.
380-440V A.C.
Frequency: 50 or 60Hz
Burden: 2.5VA for D.C. input models
Voltage: 10/27V (12, 24V) D.C.
Connections 38/58V (48V) D.C.
Elapsed Time/Hours Run Meters A.C. 90/132V (110V) D.C.
Product Codes
Bezel Size mm 48 72 96
Scale length 99999.99h 99999.99h 99999.99h
Product Code
50Hz 242-158 243-155 244-155
60Hz 242-159 243-156 244-156
D.C. Input 242-157 243-151 244-151
Impulse Counters
Impulse counters can be used to measure any parameter where a pulse can be
applied that is directly proportional to the parameter being measured. For example.
the number of motor starts or by using a combination of Paladin Transducers, kW.h.,
Ampere hour, VA hour etc., can be recorded. The Impulse counter counts one digit
every time an on/off voltage pulse is applied to the input terminals, and is non
resettable to prevent accidental resetting.
Specification
Accuracy: Pulse for Pulse
Display: 6 Digit 999999
Ratings: 110V,120V, 220V, 230V, 240V, or 415V A.C.±10%
50/60Hz
12V or 24V D.C. ±10%
Burden: 0.75VA (110V A.C.)
2.70VA (415V A.C.)
80mW (12V D.C.)
Pulse width: 50ms Minimum
Mark/Space Ratio: 1:1
Product Codes
Bezel Size mm 48 72 96
Scale length 999999 999999 999999
Product Codes
D.C. Input
12V 242-259G-MU 243-259G-MU 244-259G-MU
24V 242-259G-BD 243-259G-BD 244-259G-BD
A.C. Input
110V 242-259G-PM 243-259G-PM 244-259G-PM
120V 242-259G-PQ 243-259G-PQ 244-259G-PQ
220V 242-259G-R4 243-259G-R4 244-259G-R4
230V 242-259G-RQ 243-259G-RQ 244-259G-RQ
240V 242-259G-RR 243-259G-RR 244-259G-RR
380V 242-259G-RU 243-259G-RU 244-259G-RU
415V 242-259G-SB 243-259G-SB 244-259G-SB
15
240 Series DIN Panel Meters
Quadra 3 in 1 and 4 in 1
A range of 96mm2 DIN style 3 in 1 and 4 in 1 meters offering reduced stock holding
and savings on space, installation and commissioning. Ideally suited for generator
set applications, the range offers measurement of A.C. and D.C., current and voltage,
frequency or elapsed time. Options include customer logo on dial, coloured dial,
panel mounting gasket and heavily dampened movements.
Specification
Voltmeter: 110, 120, 200, 230, 240, 380, 400, 415, 440, 480V A.C.
nominal. Maximum end scale 600 volts.
Frequency Meter Inputs: 45/55Hz, 55/65Hz, 45/65Hz, 360/440Hz
Voltage inputs: As voltmeter inputs above
Ammeter inputs: 10mA A.C. 1 or 5A input (internal C.T.)
Hours Run: 110, 120, 220, 230, 240, 380, 400, 415, 440 Volts
50 or 60Hz
Hour Run Counting Range: 99999.99 hours
D.C. Current: 250µA to 1 Amp D.C. including 1, 5, 10, 20 and 4-20mA
D.C. for transducer inputs
D.C. Volts: 50mV to 600 Volts D.C. including 50, 60, 75 and 150mV
for shunt inputs
Burden: Current: 0.75VA per phase
Hours Run: 2.5VA
LCD Hours Run: 0.5VA
Voltage: 0.5VA
Frequency: 4VA
When ordering please specify the inputs for each parameter and the scaling required.
Product Codes
Code Description
244-80C ACV + DCI + ACA + DCA
244-80D 3 x DCI + D.C. ETM (LCD)
244-80G 3 x ACA
244-80H 3 x ACV + FRQ
244-80I 3 x ACA + ETM
244-80J 3 x ACA + ETM (LCD)
244-80K FRQ + ACV +DCI
244-80N ACA + ACV + FRQ + ETM
244-80P 3 x ACV
244-80Q ACV // FRQ // ETM + ACA
244-80R ACV // ETM + 2 x ACV
244-80S 2 x ACV + 2 x ACA
244-80T FRQ // ETM + ACV
244-80U 3 x ACA + ACV
244-80W ETM // FRQ + DCI + ACV
244-80X 4 x DCI
244-80Y ETM // FRQ + DCI
244-80Z ACV + ACA + FRQ // ETM
244-802 2 x ACV + ACA + ETM
244-803 ACV + FRQ + 2 x ACA
244-804 3 x ACA + DCI
244-806 3 x ACV + ACA
244-807 V, Hz, ETM + SWITCH
Description
ACV = Rectified A.C. voltmeter
ACA = Rectified A.C. ammeter
DCA = D.C. ammeter
DCI = D.C. indicator
ETM = Elapsed time meter
ETM(LCD) = LCD elapsed time meter
FRQ = Frequency Meter
// = In parallel with
16
240 Series DIN Panel Meters
Quadra 3 in 1 and 4 in 1
Connections
244-80H
Terminals
1 Volt Neutral L3
3 Volt Live L3
5 Frequency Neutral
6 Volt Live L2
7 Frequency Live
8 Volt Neutral L1
9 Volt Live L1
11 Volt Neutral L2
244-80I
Terminals
1 Neutral Hours Run
3 Live Hours Run
5 Current Start Red L1
10 Current Finish Black L1
11 Current Start Red L3
7 Current Finish Black L3
9 Current Start Red L2
8 Current Finish Black L2
244-80J
Terminals
1 Current Start Red L1
3 Current Finish Black L1
2 Live Hours Run
4 Neutral Hours Run
6 Current Start Red L2
8 Current Finish Black L2
9 Current Start Red L3
7 Current Finish Black L3
244-80Q
Terminals
1 Live Hours Run
5 Live Volts and Frequency
7 Neutral
8 Current Start Red
9 Current Finish Black
244-80T
Terminals
1 Voltmeter Input
3 Voltmeter Input
5 Hours Run & Frequency Meter Input
6 Hours Run & Frequency Meter Input
244-80X
Terminals
2 Positive DC 2
3 Positive DC 3
4 Negative DC 2
5 Negative DC 3
6 Positive DC 1
7 Positive DC 4
8 Negative DC 1
11 Negative DC 4
17
240 Series DIN Panel Meters
Specification
Accuracy: Class 1.5
Ratings: Ammeters: 100µA to 25A, (200µA for 05 model)
4/20mA suppressed zero
40A for model 243/244-01A
Voltmeters: 50mV to 600V
1/5V suppressed zero
50, 60, 75, 100, 150mV for use with shunts
Impedance: Ammeters: 75mV internal shunt above 60mA
Connections Voltmeters: 1000Ω/V above 1V
D.C. Ammeter
Further details on our T-Sheet T118 available on request.
Specification
Accuracy: Class 1.5
Ratings: D.C. Current: 100µA to 25A direct connected
Connections 4/20mA suppressed zero.
Dual D.C. Ammeter D.C. Volts: 50mV to 600V
1/5 volt suppressed zero
50, 60, 75, 150mV for use with shunts.
Product Codes
Bezel Size mm 96
Scale length mm 94
Product Code
Dual D.C. Voltmeter
Ammeters 244-80M
Voltmeters 244-80E
18
240 Series DIN Panel Meters
Temperature Indicators
Longscale Indicators to read temperature values, usually remotely with RTD or
thermocouple sensors supplied by the customer. RTD (Resistance Temperature
Detector) indicators measure the change in resistance of the sensor. A 2 or 3 wire
system may be used. Thermocouple indicators accept standard millivolt input
signals. Cold junction compensation is provided and thermocouple break indication
is incorporated.
Specification
Accuracy: Class 1.5 - Indicator only. RTD indicator suitable for
10Ω copper 100Ω platinum, 100 & 120Ω nickel sensors
Power in RTD is 100µW approximately. Thermocouple
indicator suitable for J (0-700°C), K (0-1200°C)
50Ω maximum Circuit Resistance.
Auxiliary Supply: Model 45R: from 63.5V to 480V A.C. at 50/60Hz
Connections Model 45T: 110, 115, 220, 240, 380, 400, 480V A.C.
Thermocouple Indicators -45TG and 12, 24, 48, 110, 125V D.C.
Burden: -45R 2VA, -45T 3VA
Product Codes
Bezel Size mm 96 144
Scale length mm 150 230
Product Codes
RTD 244-45R 246-45R
Thermocouple 244-45T 246-45T
Specification
Accuracy: Class 1.5
Ratings: 1, 2, 5, 10 & 20mA. 4/20mA suppressed zero.
Burden: See our technical data sheet T118.
19
240 Series DIN Panel Meters
Specification
Accuracy: Class 1.5
Auxiliary Supply: A.C.: 50, 110, 220, 240V 50/60Hz
D.C.: 50, 110, 125, 220V ±15%
Burden: 2VA
Product Code
Connections Bezel size mm 96 144
Tap position indicator with self Scale length mm 150 230
contained power source Product Code
Position Indicator 244-45P 246-45P
Specification
Voltage: 151/300V, 301/500V
100/150V (Model 244-12P only)
Frequency: 50/60Hz
Burden: 2.5VA/phase
Product Code
Bezel size mm 72 96
Product Code
Connections
Phase Sequence Indicator 243-12P 244-12P
Phase Sequence Indicators
20
240 Series DIN Panel Meters
Specification
Accuracy: Class 2.5 (2° electrical)
Ratings: Current: 1A or 5A for C.T.s
Voltage: 100/130V, 200-250V & 380-450V
100 - 110 for V.T. use.
Frequency: 50Hz, 60Hz, 400Hz.
Burden at 50Hz: Current: 1VA
Voltage: 4VA per Phase
Connections Current range: 20% to 125%
Single Phase Systems
Product Code - Short Scale Models
Bezel Size mm 72 96 144
Scale length mm 65 94 145
Product Code
Single Phase 243-014G-FA+ 244-42B 246-425
256-TPS
3 Phase 3/4 wire 243-014G-FA+ 244-42A 246-42A
Balanced Load 256-TPT
21
240 Series DIN Panel Meters
Specification
Accuracy: Class 2.5 (2° electrical)
Ratings: Current: -/1A or -/5A for C.T.’s
Voltage: 60 to 600V, 100/110 for V.T. use.
Frequency: 50Hz or 60Hz
Burden: Current: 2VA per coil @ 50Hz
Voltage: 4VA per coil @ 50hz (7.5VA above 250V)
Product Codes
Bezel size mm 96 144
Scale length 360° 360°
Product Codes
Single Phase 244-137 246-137
3 Phase 3 or 4 Wire 3 Currents + 1 Voltage 244-131 246-131
3 Phase 3 or 4 Wire 1 Current + 3 Voltages 244-132 246-132
3 Phase 3 or 4 Wire Unbalanced Load 244-136 246-136
Connections
Single Phase
22
240 Series DIN Panel Meters
Specification
Accuracy: Class 2.5 (2° electrical)
Ratings Voltage: 100-125V, 200-250V, 380-450V*
* Use transformer box 855-954 100-110V for V.T. use
Frequency: 50Hz,60Hz, 50/60Hz, 400Hz
Burden at 50Hz: 5VA maximum.
Product Codes
Connections Bezel size mm 96 144
Scale length 360° 360°
Product Codes
50Hz 244-145 246-145
60Hz 244-146 246-146
50/60Hz 244-147 246-147
400Hz 244-144 246-144
23
240 Series DIN Panel Meters
Specification
Ratings Voltage: 63.5, 110, 120, 220, 230, 240, 380, 400, 415, 440, 480V
110/120V (115V Nominal)
220/240V (230V nominal)
Connections 380/480V (430V nominal)
360° LED Synchroscope Volts A.C. or via V.T.
Frequency: 40/65Hz
Burden at 50Hz: 4VA maximum
Suitable for single or three phase systems
Safety: IEC1010-1 (300V A.C. rms installation degree 2)
Dielectric: 4kV rms for 1 minute
Isolation: BUS/GEN/RELAY
Vibration: To Lloyds shipping specification
*Phase difference: +0 to 20°. +/-1°
*Voltage difference: +0 to 20% +/-2%
0 to 10% for models G & H
*Time Delay: 0 to 2.5 seconds +10%
*Accuracy: Synchronisation at T.D.C. is +1˚
*360° LED Synchroscope and Synchro Check Relay Only.
24
240 Series DIN Panel Meters
Specification
Accuracy: Shortscale Class 2.5 Longscale Class 1.5
Measuring Ranges: Voltage 94-106%
Current 0-120%
Frequency Influence: 0.4% / Hz
Rating: Current: 0.2A to 5A direct connected 1A or 5A for C.T.’s.
Voltages: From 57.7 to 480V
Overload: 120% of nominal continuous voltage up to 600V maximum
Maximum Input: 600V
Frequency: 50Hz or 60Hz
Power factor: Unity Power Factor assumed range 0.5/1/0.5
Burden: Current: 1VA per phase
Voltage: 1VA per phase
Warm-up-Time: <15 minutes