Knowledge of your process is valuable, but without measurement there is no


knowledge. Companies are increasingly forced to measure process variables that
are difficult to reach and expensive to support. Distance, harsh environments and
absence of power are just a few of the hurdles faced. With operational efficiency
as the primary goal, the deployment of self-powered wireless instrumentation
provides the knowledge you need at a price you can handle.

With a wide range of available instruments for Accutech field instruments are easy to install
temperature, pressure, flow, level, and more, being self-contained with power, radio, and sensor.
Accutech instrumentation is suited to many
TM
The high-performance, license-free radio and
industrial applications, including upstream long-lasting battery reduce support costs while
Oil & Gas and remote plant applications in delivering your valuable data.
Waster and Wastewater.

Sensor network #1
Sensor network #2

Field radio
Field radio
Modbus over serial
connection to RTU BR20
or direct to host BR20

Up to 30 miles (48 kM) Trio long-haul radio

Trio K-series
TM

Cost-effective solutions for


challenging applications
2 3

Knowledge of your process is valuable, but without measurement there is no


knowledge. Companies are increasingly forced to measure process variables that
are difficult to reach and expensive to support. Distance, harsh environments and
absence of power are just a few of the hurdles faced. With operational efficiency
as the primary goal, the deployment of self-powered wireless instrumentation
provides the knowledge you need at a price you can handle.

With a wide range of available instruments for Accutech field instruments are easy to install
temperature, pressure, flow, level, and more, being self-contained with power, radio, and sensor.
Accutech instrumentation is suited to many
TM
The high-performance, license-free radio and
industrial applications, including upstream long-lasting battery reduce support costs while
Oil & Gas and remote plant applications in delivering your valuable data.
Waster and Wastewater.

Sensor network #1
Sensor network #2

Field radio
Field radio
Modbus over serial
connection to RTU BR20
or direct to host BR20

Up to 30 miles (48 kM) Trio long-haul radio

Trio K-series
TM

Cost-effective solutions for


challenging applications
4 5

Take ownership of your field Maximize ROI, improve efficiency,


instrument network and help ensure safety
Installation of a complete wireless instrument network cannot be easier than Engineered for challenging applications, Accutech networks help to reduce
using Accutech instruments, with push button configuration, integrated link costs and lessen holes in your operational data monitoring.
tests, and rugged compact designs.
• Reducing installation costs: Reduce cabling, trenching, and conduit
Dependable, self-powered, spread-spectrum radios (900 MHz and 2.4 GHz) costs. Self‑powered means no regenerative power systems.
provide effective network connectivity and long-term service. • Increased productivity: Monitor process variables you could not before.
Quick configuration, instant connectivity, and little maintenance.
Tested for use in harsh locations, Accutech field instruments can function
in extreme environments of temperature and humidity and come with a • Help ensure safety: Integrated field units tested for harsh locations
three‑year warranty. enable data point monitoring in tough environments.

Flexible wireless communication Industry standard connectivity


Accutech networks use 900 MHz or 2.4 GHz license-free, frequency-hopping, Accutech instrumentation supports industry-standard modbus protocol,
spread-spectrum radios, offering superior ranges of up to 3,000 ft (~1,000 m) providing interoperability with a wide range of industrial equipment and
using standard integrated antennas. Extended-reach options include external host systems.
directional antennas and an integrated Trio long-haul data radio that offers
256-bit AES encryption. Certified and durable
With NEMA4X packaging, Accutech wireless products are designed
Easily configured, highly scalable deployment
for demanding applications and are certified CSA Class 1, Div 1 and
Each Accutech base radio can support 100 field instruments with up to 1 sec ATEX/IECex (-ai and -d). A push button interface enables configuration
sampling on instruments; 256-base radios can coexist for extended scalability. in harsh environments.
Push button configuration and simple link test features allow entire networks to
be deployed in hours. Configure and monitor from base radio
Accutech manager configuration and management software provides a
Ease of use, low maintenance
user-friendly commissioning interface for Accutech networks, offering remote
Standard Accutech field units include a single D-cell lithium-thionyl battery that configuration and firmware upgrades, enhanced diagnostics, field unit
offers up to 10 years of service, depending on data rates and battery options. authentication to base radio, and trending/data collection.
Advance notification provides indication before a new field-replaceable battery
is required.
4 5

Take ownership of your field Maximize ROI, improve efficiency,


instrument network and help ensure safety
Installation of a complete wireless instrument network cannot be easier than Engineered for challenging applications, Accutech networks help to reduce
using Accutech instruments, with push button configuration, integrated link costs and lessen holes in your operational data monitoring.
tests, and rugged compact designs.
• Reducing installation costs: Reduce cabling, trenching, and conduit
Dependable, self-powered, spread-spectrum radios (900 MHz and 2.4 GHz) costs. Self‑powered means no regenerative power systems.
provide effective network connectivity and long-term service. • Increased productivity: Monitor process variables you could not before.
Quick configuration, instant connectivity, and little maintenance.
Tested for use in harsh locations, Accutech field instruments can function
in extreme environments of temperature and humidity and come with a • Help ensure safety: Integrated field units tested for harsh locations
three‑year warranty. enable data point monitoring in tough environments.

Flexible wireless communication Industry standard connectivity


Accutech networks use 900 MHz or 2.4 GHz license-free, frequency-hopping, Accutech instrumentation supports industry-standard modbus protocol,
spread-spectrum radios, offering superior ranges of up to 3,000 ft (~1,000 m) providing interoperability with a wide range of industrial equipment and
using standard integrated antennas. Extended-reach options include external host systems.
directional antennas and an integrated Trio long-haul data radio that offers
256-bit AES encryption. Certified and durable
With NEMA4X packaging, Accutech wireless products are designed
Easily configured, highly scalable deployment
for demanding applications and are certified CSA Class 1, Div 1 and
Each Accutech base radio can support 100 field instruments with up to 1 sec ATEX/IECex (-ai and -d). A push button interface enables configuration
sampling on instruments; 256-base radios can coexist for extended scalability. in harsh environments.
Push button configuration and simple link test features allow entire networks to
be deployed in hours. Configure and monitor from base radio
Accutech manager configuration and management software provides a
Ease of use, low maintenance
user-friendly commissioning interface for Accutech networks, offering remote
Standard Accutech field units include a single D-cell lithium-thionyl battery that configuration and firmware upgrades, enhanced diagnostics, field unit
offers up to 10 years of service, depending on data rates and battery options. authentication to base radio, and trending/data collection.
Advance notification provides indication before a new field-replaceable battery
is required.
6 7

Where traditional instruments struggle with


operational and budget goals, Accutech
wireless instrumentation provides the solution.

7
6 7

Where traditional instruments struggle with


operational and budget goals, Accutech
wireless instrumentation provides the solution.

7
8 9

A toolset for challenging applications Product overview


Accutech instrumentation offers a versatile selection of instruments and base radios with performance- Base radio Level I/O Pressure Temperature
enhancing options that can satisfy any application. Optional external sensor configurations allow
installation in below-ground areas or on process equipment that is hard to reach. External hi-gain antennas
are available for complex environments where considerable obstructions and ultralong reach are required.

With this kind of flexibility Accutech field instruments becomes a key element in any challenging application:

• Wireless wellhead monitoring and control (including plunger arrival)


• Tank level measurement (with dual float liquid interface option)
• Environmental monitoring (storm water, irrigation, reservoirs, etc.) BR10 GL10 AI10 | AV10 AP10 RT10
• Pressure measurement in any process, from 5 psi to 15,000 psi Div I, Zone 1 Gauge level Analog input Absolute pressure RTD temperature
• Monitoring remote sites with discrete input switches Base radio
• Delivering 4 – 20 mA signals from third-party instruments
• More … limited only by imagination

BR20 SL10 SI10 GP10 TC10


Div 2, Zone 2 Submersible level Switch input/output Gauge pressure Thermocouple temperature
Base radio

VC10 DP20

Valve control Differential pressure Flow


FL10
Float level

4AO, 8SW,
4AO-8SW TM10
Output modules Turbine meter totalizer

8
8 9

A toolset for challenging applications Product overview


Accutech instrumentation offers a versatile selection of instruments and base radios with performance- Base radio Level I/O Pressure Temperature
enhancing options that can satisfy any application. Optional external sensor configurations allow
installation in below-ground areas or on process equipment that is hard to reach. External hi-gain antennas
are available for complex environments where considerable obstructions and ultralong reach are required.

With this kind of flexibility Accutech field instruments becomes a key element in any challenging application:

• Wireless wellhead monitoring and control (including plunger arrival)


• Tank level measurement (with dual float liquid interface option)
• Environmental monitoring (storm water, irrigation, reservoirs, etc.) BR10 GL10 AI10 | AV10 AP10 RT10
• Pressure measurement in any process, from 5 psi to 15,000 psi Div I, Zone 1 Gauge level Analog input Absolute pressure RTD temperature
• Monitoring remote sites with discrete input switches Base radio
• Delivering 4 – 20 mA signals from third-party instruments
• More … limited only by imagination

BR20 SL10 SI10 GP10 TC10


Div 2, Zone 2 Submersible level Switch input/output Gauge pressure Thermocouple temperature
Base radio

VC10 DP20

Valve control Differential pressure Flow


FL10
Float level

4AO, 8SW,
4AO-8SW TM10
Output modules Turbine meter totalizer

8
10 11

Specifications

BR10 BR20 AI10 | AV10 AP10 RT10 SI10 SL10 TC10


Base radio Base radio Current | voltage Absolute pressure RTD temperature Switch input field unit Submersible level Thermocouple
multi-input field unit field unit field unit field unit temperature field unit
• Supports 100 field • DIN rail mount • Dual contact closure
units with 915 MHz • Supports 100 field • Accuracy: ± 0.1% of full- • Accuracy: • Electronics accuracy: switch input with counter • Submersible hydrostatic • types B, C, E, J, K, L, N,
or 2.4 GHz radio units with 915 MHz scale reading at reference ± 0.1% of reading function pressure sensor S, T, U
–– ± 0.25% of full-scale
• Serial modbus via RS-485 or 2.4 GHz radio conditions at 20 °C (68 °F) • 4 wire 100 or 1000 ohm • Counter frequency up • Accuracy: ± 0.5% of URL • Electronics accuracy:
• Remote antenna option • Optional Trio data radio • Dual current (4 – 20 mA) DIN RTD to 5 Hz ± 0.1% of full-
–– ± 0.5% of URL • Pressure ratings up to
• 10 – 30 VDC input power for long-haul connectivity or voltage (0 – 10 V) • Integrated RTD or junction • Optional dual switch dry 30 psi (2 Bar), lengths scale reading
• 30 psia and 250 psia max
with host analog inputs box option for customer contact outputs capable of to 75’ (15 m) • Integrated single T/C or
• CSA Class 1, Div1 (xp) pressure options
• Serial modbus via RS-485 • Includes dual contact supplied RTD switching 1A @ 30 V junction box option that
• ATEX/IECEx –d • NEMA 4X housing • Vent to atmosphere
• 11 – 30 VDC input power closure inputs • NEMA 4X housing • Remote antenna option or to tank supports dual customer
• Remote antenna and supplied T/Cs
• CSA Class 1, Div2 • Remote antenna option • Remote antenna and • NEMA 4X housing • Remote antenna option
remote sensor option
• NEMA 4X enclosure remote sensor option • CSA Class 1, Div1 (IS) • NEMA 4X housing
• ATEX/IECEx –n • CSA Class 1, Div1 (IS) • NEMA 4X housing
• CSA Class 1, Div1 (IS) • CSA Class 1, Div1 (IS) for models without outputs; • Remote antenna option
• ATEX/IECEx –ia • CSA Class 1, Div1 (IS)
Div2 with outputs • CSA Class 1, Div1 (IS)
• ATEX/IECEx –ia • ATEX/IECEx –ia • ATEX/IECEx –ia
• ATEX/IECEx –ia for models • ATEX/IECEx –ia
without outputs; IECEX-d
for models with outputs

DP20 FL10 GL10 GP10 TM10 VC10 4AO, 8SW, 4AO-8SW


Differential pressure Float level field unit Gauge level field unit Gauge pressure Turbine meter totalizer Valve controller Output modules
field unit field unit field unit field unit
• For use with Siemens 2000 • Accuracy: • Direct connection
• Accuracy: ± 0.2% of URL series probes –– ± 0.25% of full scale • Accuracy: • Interfaces many 2-wire • Accuracy: ± 0.25% between Accutech base
• ¼” and ½” resolution at 20 °C (68 °F) magnetic pickups of full‑scale reading radios and DCS or process
• Available in five different –– ± 0.25% of full scale
options control systems
pressure ranges: –– ± 0.5% of URL at 20 °C (68 °F) • Instantaneous flow • Sales valve actuation
• Lengths up to 30’ & totalized values and control • Provides analog and
–– +/- 100in H2O • 15 psig and 30 psig max –– ± 0.25% of URL
discreet outputs from
–– +/- 300in H2O • Single float or dual float for pressure options (15,000 psig) • Frequency 1 Hz to 10 KHz • Control and monitoring
associated field units
liquids interface • Specific gravity correction –– ± 0.3% of URL • NEMA 4X housing of plunger lift systems
–– +/- 25 psi • DIN rail mounted.
• NEMA 4X housing and multiple units of (2,500 & 5,000 psig) • Remote antenna option • Start-up and default
–– -25 psi to + 100 psi • Stackable
• Remote antenna option measure selection –– ± 0.5% of URL configuration options
–– -25 psi to + 300 psi • CSA Class 1, Div1 (IS) (25 max, 100 AO, 200 DO)
• CSA Class 1, Div1 (IS) • NEMA 4X housing (5, 15, 30, 100, 250, • Integrated pressure
• Overload limit: • ATEX/IECEx –ia • Three models available:
• Remote antenna and 1,000 & 10,000 psig) sensor for active control
• Available in North
–– 3000 psi remote sensor option • 5, 15, 30, 100, 250, 1,000, of solenoid pulse width –– 4 channel
America only
• NEMA 4X housing 2,500, 5,000, 10,000, • Two digital inputs, for analog output
• CSA Class 1, Div1 (IS)
• Remote antenna option 15,000 psig plunger arrival and discrete –– 8 point contact closure
• ATEX/IECEx –ia
• CSA Class 1, Div1 (IS) • NEMA 4X housing input applications –– Combination of 4 ch
• Remote antenna and • CSA Class 1 Div 1, harsh analog/8 contact
• ATEX/IECEx –ia
remote sensor option location certified
• CSA Class 1, Div1 (IS)
• ATEX/IECEx –ia
10 11

Specifications

BR10 BR20 AI10 | AV10 AP10 RT10 SI10 SL10 TC10


Base radio Base radio Current | voltage Absolute pressure RTD temperature Switch input field unit Submersible level Thermocouple
multi-input field unit field unit field unit field unit temperature field unit
• Supports 100 field • DIN rail mount • Dual contact closure
units with 915 MHz • Supports 100 field • Accuracy: ± 0.1% of full- • Accuracy: • Electronics accuracy: switch input with counter • Submersible hydrostatic • types B, C, E, J, K, L, N,
or 2.4 GHz radio units with 915 MHz scale reading at reference ± 0.1% of reading function pressure sensor S, T, U
–– ± 0.25% of full-scale
• Serial modbus via RS-485 or 2.4 GHz radio conditions at 20 °C (68 °F) • 4 wire 100 or 1000 ohm • Counter frequency up • Accuracy: ± 0.5% of URL • Electronics accuracy:
• Remote antenna option • Optional Trio data radio • Dual current (4 – 20 mA) DIN RTD to 5 Hz ± 0.1% of full-
–– ± 0.5% of URL • Pressure ratings up to
• 10 – 30 VDC input power for long-haul connectivity or voltage (0 – 10 V) • Integrated RTD or junction • Optional dual switch dry 30 psi (2 Bar), lengths scale reading
• 30 psia and 250 psia max
with host analog inputs box option for customer contact outputs capable of to 75’ (15 m) • Integrated single T/C or
• CSA Class 1, Div1 (xp) pressure options
• Serial modbus via RS-485 • Includes dual contact supplied RTD switching 1A @ 30 V junction box option that
• ATEX/IECEx –d • NEMA 4X housing • Vent to atmosphere
• 11 – 30 VDC input power closure inputs • NEMA 4X housing • Remote antenna option or to tank supports dual customer
• Remote antenna and supplied T/Cs
• CSA Class 1, Div2 • Remote antenna option • Remote antenna and • NEMA 4X housing • Remote antenna option
remote sensor option
• NEMA 4X enclosure remote sensor option • CSA Class 1, Div1 (IS) • NEMA 4X housing
• ATEX/IECEx –n • CSA Class 1, Div1 (IS) • NEMA 4X housing
• CSA Class 1, Div1 (IS) • CSA Class 1, Div1 (IS) for models without outputs; • Remote antenna option
• ATEX/IECEx –ia • CSA Class 1, Div1 (IS)
Div2 with outputs • CSA Class 1, Div1 (IS)
• ATEX/IECEx –ia • ATEX/IECEx –ia • ATEX/IECEx –ia
• ATEX/IECEx –ia for models • ATEX/IECEx –ia
without outputs; IECEX-d
for models with outputs

DP20 FL10 GL10 GP10 TM10 VC10 4AO, 8SW, 4AO-8SW


Differential pressure Float level field unit Gauge level field unit Gauge pressure Turbine meter totalizer Valve controller Output modules
field unit field unit field unit field unit
• For use with Siemens 2000 • Accuracy: • Direct connection
• Accuracy: ± 0.2% of URL series probes –– ± 0.25% of full scale • Accuracy: • Interfaces many 2-wire • Accuracy: ± 0.25% between Accutech base
• ¼” and ½” resolution at 20 °C (68 °F) magnetic pickups of full‑scale reading radios and DCS or process
• Available in five different –– ± 0.25% of full scale
options control systems
pressure ranges: –– ± 0.5% of URL at 20 °C (68 °F) • Instantaneous flow • Sales valve actuation
• Lengths up to 30’ & totalized values and control • Provides analog and
–– +/- 100in H2O • 15 psig and 30 psig max –– ± 0.25% of URL
discreet outputs from
–– +/- 300in H2O • Single float or dual float for pressure options (15,000 psig) • Frequency 1 Hz to 10 KHz • Control and monitoring
associated field units
liquids interface • Specific gravity correction –– ± 0.3% of URL • NEMA 4X housing of plunger lift systems
–– +/- 25 psi • DIN rail mounted.
• NEMA 4X housing and multiple units of (2,500 & 5,000 psig) • Remote antenna option • Start-up and default
–– -25 psi to + 100 psi • Stackable
• Remote antenna option measure selection –– ± 0.5% of URL configuration options
–– -25 psi to + 300 psi • CSA Class 1, Div1 (IS) (25 max, 100 AO, 200 DO)
• CSA Class 1, Div1 (IS) • NEMA 4X housing (5, 15, 30, 100, 250, • Integrated pressure
• Overload limit: • ATEX/IECEx –ia • Three models available:
• Remote antenna and 1,000 & 10,000 psig) sensor for active control
• Available in North
–– 3000 psi remote sensor option • 5, 15, 30, 100, 250, 1,000, of solenoid pulse width –– 4 channel
America only
• NEMA 4X housing 2,500, 5,000, 10,000, • Two digital inputs, for analog output
• CSA Class 1, Div1 (IS)
• Remote antenna option 15,000 psig plunger arrival and discrete –– 8 point contact closure
• ATEX/IECEx –ia
• CSA Class 1, Div1 (IS) • NEMA 4X housing input applications –– Combination of 4 ch
• Remote antenna and • CSA Class 1 Div 1, harsh analog/8 contact
• ATEX/IECEx –ia
remote sensor option location certified
• CSA Class 1, Div1 (IS)
• ATEX/IECEx –ia
Foxboro by Schneider Electric
38 Neponset Avenue
Foxboro, Massachusetts 02035 USA
Direct worldwide: +1-508-549-2424
Toll free within North America: 1-866-746-6477
Email: systems.support@schneider-electric.com
www.schneider-electric.com

June 2016

©2016 Schneider Electric. All Rights Reserved.


Schneider Electric | Life Is On is a trademark and the property of
Schneider Electric SE, its subsidiaries, and affiliated companies.
Images and illustrations in this document are not contractual.
998-19592430_GMA-US v2

You might also like