SHEET INSTRUCTIONS USE AND MAINTENANCE

SERIES
SMART

®
CONTROLLER R3FC
®

THIS OPERATING INSTRUCTION APPLY

Type Box Colour Dimensions Code


R3FC Circuit 80 x 95 x 35 PV R3FCX A2 STD
R3FC Fire-retardant plastic RAL 7035 100 x 100 x 50 PV R3FCX Z2 STD
R3FC Aluminum RAL 7035 100 x 100 x 50 PV R3FCX Z2 STM
R3FC/DIN Circuit 115 x 185 x 50 PV R3FCX D2 STD
R3FC+PRX92 Circuit+circuit for sensor NPN/PNP RAL 7035 100 x 100 x 50 PV R3P92 Z2 STD

GUARANTEE

1) The controller is guaranteed for a period of 1 year from the date shown on the inside.
2) The guarantee covers the free replacement or repair of components parts that are defective
at origin for manufacturing errors.
3) The guarantee is not valid for damage caused accidentally due to improper use or negligence
and in case of alterations or repair carried out by unauthorized persons.
Design and specifications could be subjected to change without notice.

DECLARATION OF CONFORMITY

This equipment conforms with ecc directive 2014/30/UE


(EMC- Electromagnetic Compatibility)
and directive 2014/35/UE (LVD - Low Voltage Directive)

REPLACEMENT POLICY

Please fill out a form for Technical a Assistance in “Service” section www.mpelettronica.com

Code: MUMR3FC Rev..: 00 Edit: E. Pedrazzi Date: 02/14 Sheet : 2


®

SAFETY INSTRUCTIONS

DANGER Indicates an immediate threatening danger.

Non-compliance with this information can result in death or serious personal


injuries (invalidity).

WARNING Indicates a possibly dangerous situation.

Non-compliance with this information can result in death or serious personal


injuries (invalidity).

CAUTION Indicates a possibly dangerous situation.

Non-compliance with this information can result in damage to property or .light


to medium personal injuries.

NOTE Indicates general notes, useful operator tips and operating recommendations
which don’t affect safety and health of the personnel.

Code: MUMR3FC Rev..: 00 Edit: E. Pedrazzi Date: 02/14 Sheet : 3


®

NOTE Before using the appliance it is necessary to read attentively the instructions included in this
technical sheet which provides you information about safety installation, use and maintenance.
keep this sheet safely for further information.

GENERAL INSTRUCTIONS

DANGER Before connect the equipment to the mains socket, make sure that the nameplate data match
those of the mains power supply.
Only use this equipment in accordance with the porpouse for which it is designed; i.e. for
regolation of the amplitude of an electromagnetic vibrator feeder. Any other use is to considered
improper, therefore hazardous.

The Manufacturer cannot be held liable for any improper, incorrect or unreasonable use of
the equipment, switch it off and do not tamper with it. If repair is needed, please contact the
Manufacturer’s Technical.

Service Centre only, as they use original spare parts.


Failure to observe the above the recommendations could impair the safety of the equipment.

All operations regarding adjustement, measurement and testing when required, must only be
carried out by authorized and qualified personnel.

The Manufacturer shall accept no liability for damage to persons, animals or objects caused by
work on the equipment carried out by unauthorized and unqualifield personnel.

Before switching on the equipment, connect the mains voltage, conforming to the current
regulation, and the vibratory feeder.

WARNING Verifying that the installation has an appropriate ground wiring system.

TURN OFF THE POWER BEFORE OPENING.

NOTE
NOTE : Don’t use the apparatus in proximity of subject zones to vibrations, or in acid and humid
working environment

WARNING If vibratory feeder works bad or doesn’t work:


Check electric wires, to check regolation MIN/MAX.
Swicht OFF voltage and to check the fuses and, this case, to check current MAX (ampere)
in the vibrator.

Code: MUMR3FC Rev..: 00 Edit: E. Pedrazzi Date: 02/14 Sheet : 4


®

TECHNICAL CHARACTERISTICS

Circuit Type: R3FC Degree Of Protection: Ip55in Box (Only Circuit Ip00)

Supply Voltage: 115 Or 230V ± 10% 50/60Hz Position Of Assemblage: Horizontal Or Vertical.

Consumption: 1,5 W Max Degree Of Pollution: 2

Current Max: 3/4A (Rms) Temperature Of Storage: -15 °C / + 80 °C

Load Min.: 50Ma Rms Temperature Of Operation: -5 °C / + 55 °C

Potentiometer Of Reg.: 100K Ohm Linear Range Of Relative Humidity: 80% Till to 31°C

Freq. Of Vibration: 3000/6000V/M (50Hz) Installation Class: Ii

Time Ramp: 0,2 Sec. Or 2 Sec. (Selectable) Altitude: Till to 2000 Meters

Regulation Min.: 80V ± 30% European Norms: EMC CE

Input On/Off: Free Contact - Signal Voltage 0/24V Warranty: 1 Year (from date on circuit)

WAVE FORMS
Fig. 1

Fig. 2
Fig. 3

WAVE FORMS
Supply controller (yellow)
Output vibrator (blue)
Frequency 50 Hz - 3000 V/m (Vibrator)
Fig. 1 : Output V/max 216V
Fig. 2 : Output V/medio 160V
Fig. 3 : Output V/min 52V

Code: MUMR3FC Rev..: 00 Edit: E. Pedrazzi Date: 02/14 Sheet : 5


®

PARTICULAR INSTRUCTIONS

CAUTION Before give voltage to the controller connect the supply voltage (clamps 2-3 CONN1), verifying
that the installation has an appropriate ground wiring system and the vibrator (clamps
VIBRATOR - CONN 2) of the connector (1-4 ground).
According European Norms EMC the controller have a line-filter with leakage current to ground
less 1 mA.
To adjust intensity of vibration of the vibratory feeder, turn the adjustement knob (potentiometer
100K) on the box.

NOTE Regolation MIN/MAX


To adjust the Min./Max voltage of the vibratory feeder, proceed as follows :
MIN REG.: Turn the potentiometer to minimum, then set the minimum vibration by means of
relative trimmer TR1.
MAX REG. : Turn the potentiometer to maximum, then set the maximum vibration by means of
relative trimmer TR2.
N.B. : Use a small bladed screw driver in order not to damage the trimmer. Turn it in vertical
direction respect to the PC board.

CAUTION ON- OFF


The vibratory feeder can be switched off by contact without voltage, using the auxiliary ON/
OFF input.
Start Ramp
Is possible to change the time of the start ramp (slow 1 sec or fast 0,1 sec) by Y3.
3000/6000 V/m
Is possible to change the frequency of vibration 3000V/m-50Hz (3600V/m-60Hz) or 6000V/m-
100Hz (7200V/m-120Hz) by Y1-Y2; before switch off the voltage.

NOTE Green Led


Green Led indicates Voltage ON- Fuses intact and signals damages to the entry stage of the
stabilizing module.
Double Speedy
Is possible (on request) to have nr.2 speed (hight and slow speed ) with 2 potentiometers (see
catalogue’s sheet DTCV2V).

Code: MUMR3FC Rev..: 00 Edit: E. Pedrazzi Date: 02/14 Sheet : 6


®

SHEET

1/1

Sheet : 7
INPUT ON/OFF

DESIGN AND SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE


1 2 3

Description: CONTROL CIRCUIT R3FC (STABILIZED)


1 2 3

DRAFTSMAN
E. PEDRAZZI
FAST RAMP SLOW RAMP
Y1

Date: 02/14
COMPENSATION
Y2
CONN.X

MODULE
Y3
LED "ON"
GREEN
CLOSED
115V

115V
OPEN
230V

CE type

DATE
02/03
CONN.2

Edit: E. Pedrazzi
3,5mm (hole fixing)
VIBRATOR

REV
00
CONN.1
Fuse 5x20 3A F

Rev..: 00
LINE

DTR3FC
CODE
NOTE:
If you use only the electronic circuit (IP00) insert and cable it in a box that

Code: MUMR3FC
could guarantee an excellent safety degree respecting the European
regulation in force and isolate the terminals of the potentiometer with the
rubbers provided.
Decline all responsability for damage caused by improper use of the circuit
Cross Reference: SMART Controllers Series - ISO Series

IP



CE
Box

EMC

Code
Code

Sensor

Amps
0/10V
Photo

Overload

ON/OFF
50/100
60/120

NPN/PNP

ON/OFF
0/20 mA
Slow/Fast
Reg. Volt

50/60 Hz
Min/Max

VoltageV
Time Ramp

Amplitude
Regulation

Free Voltage

Code: MUMR3FC
Dimensions

Signal Voltage
Freq Output Hz
3000-6000 100 x 100 x 50 1
R3FC 115 / 230 3 Man.Pot. 3600-7200 65 2 R3FC

3000-6000 100 x 100 x 50 1


R3FC-ISO 115 / 230 3/4 Man.Pot. 3600-7200 65 R3FC-ISO

3000-6000 100 x 150 x 80 3

Rev..: 00
R3FSC 115 / 230 4 Man.Pot. 3600-7200 65 115 x 140 x 60 6 R3FSC

3000-6000 100 x 150 x 80 3


R3FSC-ISO 115 / 230 4/5 Man.Pot. 3600-7200 65 115 x 140 x 60 6 R3FSC-ISO

3000-6000 4
R5FC 115 / 230 6 Man.Pot. 65 130 x 165 x 70 5 R5FC
3600-7200 140 x 165 x 65

115 / 230 3000-6000 4


R5FC-ISO 6/8 Man.Pot. 65 130 x 165 x 70 R5FC-ISO
400 3600-7200 5
140 x 165 x 65

3000-6000

Edit: E. Pedrazzi
RS96C 6 Man.Pot. 65 115 x 140 x 60 6 RS96C
115 / 230 Autom. 3600-7200

Man.Pot. 3000-6000 100 x 200 x 80 7


CV99 115 / 230 6 3600-7200 65 CV99
Autom.

115 / 230/ Man.Pot. 3000-6000 130 x 130 x 90 8


RV6 400 6 3600-7200 65 RV6
Autom.

Date: 02/14
1 2 3 4 5 6 7 8

Sheet : 8
1 All controllers are stabilized 3 With circuit PRX92-PRX99 inside
2 Other voltage on request 4 With circuit PRX07 inside

M.P. Elettronica srl - Via Torino 62 - 20099 Sesto san Giovanni (Mi) - Italy - Tel: +39 02 2403864 - Fax: +39 02 2400643
®
DIMENSIONS

METALLIC BOX
CIRCUIT
PV R3FCX Z2 STM
PV R3FCX A2 STD
100x100x50

METALLIC BOX
PV R3FCX Z2 SM1
100x100x50

PLASTIC BOX
PV R3FCX Z2 STD
100x100x50
HEADQUARTERS
MP Elettronica srl
via Torino 62
20099 Sesto San Giovanni -MI - ITALY
tel.: +39 (02) 24 03 864
Fax: +39 (02) 24 00 643
www.mpelettronica.com
mp@mpelettronica.com

PRODUCTION UNIT 1 - WAREHOUSE


MP Elettronica srl
via Campagna 10
21041 Albizzate (VA) - ITALY
tel.: +39 (0331) 98 52 10
Fax: +39 (0331) 98 52 10
www.mpelettronica.com
mp1@mpelettronica.com

PRODUCTION UNIT2
MP Elettronica srl
via Torino 80
20099 Sesto San Giovanni -MI - ITALY
tel.: +39 (02) 39 66 23 68
Fax: +39 (02) 24 00 643
www.mpelettronica.com
laboratorio@mpelettronica.com

CUSTOMER SERVICE 24/24


HOT LINE : VOICE - WHATSAPP
mp1@mpelettronica.com
ENGLISH +39 393 925 6076

export@mpelettronica.com
GERMAN +39 339 449 4940

export@mpelettronica.com
FRENCH +39 339 449 4940

mp@mpelettronica.com
ITALIAN +39 393 958 2535