Non-sewered sanitation systems –
Prefabricated integrated treatment
units – General safety and
performance requirements for
design and testing.
20-08-21
TÜV SÜD LEGAL ENTITY | INTRODUCTION TO ISO 30500 2
ISO 30500 Certification Classes & Test Duration
▪ Class 1 System Class
A. Document Checks Class 1: Non-biological treatment processes
one frontend – backend
B. Controlled Laboratory Testing ≥ 32 days
C. Field Testing for ≥ 30 days Class 2: Biological treatment processes
one frontend – multiple backends
Loading Patterns
ISO 30500
Mechanical Requirements
Controlled
Laboratory Environmental Parameters
Acoustics Parameters
Odour Requirements
Electrical Requirements
Electrical Requirements
Design Serviceable life of
Field Testing Guidelines Lifetime (4.5) 10 years
Field Verification
of Performance Environmental Parameters
Human Health Parameters
TÜV SÜD LEGAL ENTITY | INTRODUCTION TO ISO 30500 20-08-21 5
Secure
design (4.7) Theft deterrence
General Safety General Technical Information
General Safety Temp = 5 - 50 °C
Operating
Humidity = 20 – 100%
Process Design Safety conditions (4.8)
Pressure = 76 – 101 kPa
Documentation Material Safety
Acoustics Parameters
corrosion.
Mechanical Requirements
Controlled
Laboratory Environmental Parameters Fire
Resistance Materials should be fire resistant
Testing Human Health Parameters
(4.10.2) and conform to ISO 10295
Air Emissions Parameters
Acoustics Parameters
Connections &
Odour Requirements Joints (4.11)
Electrical Requirements
Electrical Safety General Safety Pipes, Hoses Pipes & Hoses to be fixed in place
Process Design Safety &Tanks (5.4.2) Tanks to withstand stresses
Capacity,
Process Design Safety Information & Common items not to be added
Material Safety Warning (4.13.1) Service & Contact information
Documentation
Mech. & Elec. Safety Output reuse information (if any)
Checks
User Interface Experience Manufacturer, model, serial, date of
Marking &
Maintenance Design manufacture, operational weight,
Labelling (4.13.2)
electrical details
Sustainability
Mechanical Requirements
Tools &
Controlled
Environmental Parameters Devices
Laboratory (4.14.4) Language
Testing Human Health Parameters System general information
Drawings
Air Emissions Parameters User Manual
Contact details
(4.14.5)
Acoustics Parameters Installation and operating instructions
Maintenance
Odour Requirements etc.
Electrical Requirements
Handling &
Lifting gears
Field Verification Field Testing Guidelines Transportation
Fixation points
(4.14.6 )
of Performance Environmental Parameters
Human Health Parameters
TÜV SÜD LEGAL ENTITY | INTRODUCTION TO ISO 30500 20-08-21 11
Eg. Phosphorus,
Sustainability General Technical Information
General Safety
Nutrient
Recovery (8.2)
Nitrogen,
Potassium.
Process Design Safety
Mechanical Requirements
Controlled Life Cycle ISO 14040 & 14044
Laboratory Environmental Parameters ‘Includes end-of-life
Assessment (8.5)
Testing Human Health Parameters
considerations
Mechanical Requirements
Controlled Stress
Laboratory Environmental Parameters (7.2.8.2)
Testing Human Health Parameters
Odour Requirements
Electrical Requirements
➢ Normal Loading
Normal Loading
Pattern
Example
Diarrhoea
(12 pax design) ISO30500 (7.2.8) Faeces (g) Faeces (g) Water (l)
Total 1500 1500 3
6am to 9am 35% 525 525 1.1
11am to 2pm 25% 375 375 0.7
5pm to 8pm 40% 600 600 1.2
Requirements
General Safety
Visibility of
Process Design Safety
Faeces (6.3)
Documentation Material Safety
Mechanical Requirements
Controlled Slip, trip and falling
Laboratory Environmental Parameters (6.6)
Testing Human Health Parameters
Tightness Test
Air Emissions Parameters
(A3.1)
Acoustics Parameters
Evacuation
Odour Requirements Mechanism (A3.3)
Electrical Requirements
Nitrogen
Mechanical Requirements
Controlled
Environmental Parameters Total
Laboratory Phosphorus
Testing Human Health Parameters
Odour Requirements
Electrical Requirements
Loading Patterns
Helminth
ISO 30500
Mechanical Requirements
Controlled
Laboratory Environmental Parameters Protozoa
Testing Human Health Parameters
Acoustics Parameters
Odour Requirements
Electrical Requirements
Control
Parameters
Spiking
Input Output
2 S1 3 S2
NSSS
Loading Patterns
ISO 30500
Mechanical Requirements
Controlled
Laboratory Environmental Parameters
Odour Requirements
Electrical Requirements
Odour Requirements
Electrical Requirements
1.5m
Points to note
Indoor testing
1. About 1 to 1.5 m from the ground above the squat or seat pan Ambient air particulate comprehensive sampler
2. Superstructure door to remain closed during entire sampling
3. Threshold values in ppm are based on ideal conditions (1 atm
& 0°C)
Indoor testing
Atmospheric air
sampling pump
PM2.5
Mechanical Requirements
Controlled NH3
Laboratory Environmental Parameters
SO2
Testing Human Health Parameters
Indoor PAH
Air Emissions Parameters
O2
Stack
Acoustics Parameters
Vol. Flow
Odour Requirements
Moisture
Electrical Requirements Content
10D
2D 8D 8D
Sampling
Velocity and Point
Temp.
Measurement
EPA Method 1A
Inlet = min 8D
Points to note Outlet = min 8D
1. Most significant sources of air pollutants within the NSSS
2. External gas vent/Stack as outlined in EPA Method 1A
3. The guideline generally helps to remove inaccurate readings and best practices
Loading Patterns
ISO 30500
Mechanical Requirements
Controlled Within
Laboratory Environmental Parameters Superstructure
Testing Human Health Parameters
Odour Requirements
Electrical Requirements
A✓ B
TÜV SÜD PSB SINGAPORE| OVERVIEW TO ISO 30500 20-08-21 30
Acoustics Parameters (External)
External / Backend Measurement
External / Backend
▪ The external measurement points shall be determined
relative to a reference parallelepiped, which shall be
determined as the smallest imaginary rectangular
parallelepiped that could spatially enclose the system
Loading Patterns
ISO 30500
Mechanical Requirements
Controlled
Laboratory Environmental Parameters
Within
Testing Human Health Parameters Superstructure
(Frontend)
Air Emissions Parameters
Acoustics Parameters
Electrical Requirements
Olfactometer
2. Threshold
3. Sample size
Unpleasant
Unacceptable
TÜV SÜD PSB SINGAPORE| OVERVIEW TO ISO 30500 20-08-21 35
Electrical Requirements General Technical Information
General Safety
Process Design Safety
Loading Patterns
ISO 30500
Legends
B = Inlet Baseline study (daily). Total N & P only
D = Daily sampling
W = Weekly sampling
M = Monthly sampling
C = Complete
(Field)
General Safety
Process Design Safety
Loading Patterns
ISO 30500
Mechanical Requirements
Controlled
Laboratory Environmental Parameters
Acoustics Parameters
Odour Requirements
Electrical Requirements
Loading Patterns
ISO 30500
Mechanical Requirements
Controlled TSS
Laboratory Environmental Parameters
Acoustics Parameters
Total
Odour Requirements Phosphorus
Electrical Requirements
Loading Patterns
ISO 30500
Mechanical Requirements
Controlled
Laboratory Environmental Parameters
Acoustics Parameters
100% Pass
Odour Requirements
Requirement
Electrical Requirements
Acoustics Parameters
Protozoa
Odour Requirements
100% Pass
Requirement
Electrical Requirements
Virus
Field Testing Guidelines
Field Verification
of Performance Environmental Parameters
Human Health Parameters
TÜV SÜD LEGAL ENTITY | INTRODUCTION TO ISO 30500 20-08-21 42
Thank You
Notes
• NOx molecular weight was based on NO2 (46 g/mol)
• VOC was using a conventionally set conversion factor of (1.608) which is using the carbon content or propane. Propane is also used
as the test gas for adjustment of the FID analyser
• PAH is using Benzo-a-pyrene as lead component for PAHs in Germany. The limit values for benzo-a-pyrene is 0.05 mg/m3 in
Germany, which is used for the sum of PAH in the threshold value.
ii. Error
➢ For consistency and easy pass/fail criteria comparison,
threshold values should be revised as well.
TÜV SÜD WATER SERVICES | VALIDATION TESTS FOR ISO 30500 – CHALLENGES & CORRECTIONS 20-08-21 46
Normalisation of Concentrations (A.3.6.5.1)
▪ For Combustion/Incineration Processes
1 21 − 7 101.3 273.15 + 𝑇
𝐶𝑁 = 𝐶 × × × ×
1 − 𝐻2 𝑂 21 − 𝑂2 𝑚𝑒𝑎𝑠𝑢𝑟𝑒𝑑 𝑝 273.15
where
𝐶𝑁 is the normalised concentration in ppmv, ppbv, g/m3 or mg/m3
𝐶 is the measured concentration, in the same units as 𝐶𝑁
𝑚3 𝐻2𝑂
𝐻2𝑂 is the humidity measured in volume fraction of water vapour
𝑚3 𝑔𝑎𝑠
𝑚3 𝑂2
O2 measured is the O2 concentration fo the exhaust gas measured in x 100
𝑚3 𝑒𝑥ℎ𝑎𝑢𝑠𝑡 𝑔𝑎𝑠